Neutron source in the MCNPX shielding calculating for electron accelerator driven facility

Argonne National Laboratory (ANL) of USA and Kharkov Inst. of Physics and Technology (KIPT) of Ukraine have been collaborating on the design development of an experimental neutron source facility. It is an accelerator driven system (ADS) utilizing a subcritical assembly driven by electron accelerator. The facility will be utilized for performing basic and applied nuclear researches, producing medical isotopes, and training young nuclear specialists. Monte Carlo code MCNPX has been utilized as a design tool due to its capability to transport electrons, photons, and neutrons at high energies. However the facility shielding calculations with MCNPX need enormous computational resources and the small neutron yield per electron makes sampling difficulty for the Monte Carlo calculations. A method, based on generating and utilizing neutron source file, was proposed and tested. This method reduces significantly the required computer resources and improves the statistics of the calculated neutron dose outside the shield boundary. However the statistical errors introduced by generating the neutron source were not directly represented in the results, questioning the validity of this methodology, because an insufficiently sampled neutron source can cause error on the calculated neutron dose. This paper presents a procedure for the validation of the generated neutron source file. The impact of neutron source statistic on the neutron dose is examined by calculating the neutron dose as a function of the number of electron particles used for generating the neutron source files. When the value of the calculated neutron dose converges, it means the neutron source has scored sufficient records and statistic does not have apparent impact on the calculated neutron dose. In this way, the validity of neutron source and the shield analyses could be verified. (authors)

43 PARTICLE ACCELERATORS↗

TRANSIENT THERMAL MODELING OF THE HIGH BURNUP DEMONSTRATION RESEARCH PROJECT CASK USING STAR-CCM+ AND COBRA-SFS

The Department of Energy in collaboration with the Electric Power Research Institute is in the process of conducting the High Burnup Demonstration Project. Where the objective is to characterize the performance of high-burnup fuel in long term storage. As part of this demonstration, a TN-32B dry storage cask was instrumented and loaded with spent nuclear fuel at North Anna Nuclear Generating Station in November 2017. The project cask provides a unique opportunity to gain information on spent fuel and cask performance from an in-service operational system. The cask was instrumented with thermocouples inside of the fuel assemblies, then loaded and dried using normal procedures. After the drying process a thermal soak period where the cask was left indoors was used to obtain steady temperatures for model comparison along with surface temperatures. This paper details thermal modeling validation work that was done to model both the steady state and transient cases. Two modeling tools were used to predict temperatures in the cask. The general purpose CFD and heat transfer code STAR-CCM+ was used with both a detailed pin-by-pin model was used along with a more efficient k-effective simplification. The other code is COBRA-SFS, a purpose-built detailed thermal modeling tool developed and maintained at PNNL. Results from all the modeling tools were compared blind to the test data. Each model utilized general design information and compared reasonably well to the blind steady state data using convection and surface temperature boundary conditions. Post-test adjustments were later made to better reflect the “as built” conditions of the cask. Based on lessons learned from the steady state analysis the vacuum drying process was modeled in both codes. Utilizing the measured loading conditions the transient models were able to compare very well with the measured data. Overall the project showed an ability to model spent fuel storage conditions very well and future work is planned to generalize the methodology used for vacuum drying.

Thermal Analysis, Spent Fuel, Dry Storage↗

Alabama Residential Energy Code Field Study: Baseline Report

A research project in the state of Alabama identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in March 2014 and continued through May 2014. During this period, research teams visited 134 homes during various stages of construction, resulting in a substantial data set based on observations made directly in the field. Analysis of the data has led to a better understanding of the energy features present in homes, and indicates nearly $1.3 million in potential savings to Alabama homeowners that could result from increased code compliance. Public and private entities within the state can use this information to justify and catalyze future investments in energy code training and related energy-efficiency programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Montana Residential Energy Code Field Study

A research project in the state of Montana identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in May 2018; data collection began in June 2018 and continued through September 2018. Analysis of the data has led to a better understanding of the energy features present in homes and identified nearly $192,000 in potential annual savings to Montana homeowners that could result from increased compliance with the Montana Residential Energy Code.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Energy Code Field Study (Final Report)

What is the dollar value of increasing compliance with the energy code? Ultimately, this is the question that policy makers, funders, and program implementers care about. With this in mind, Pacific Northwest National Laboratory (PNNL) developed a new methodology capable of determining how much energy cost savings could potentially be gained through better compliance with the code (Rosenberg et al. 2016). On March 2, 2016 DOE issued Funding Opportunity Announcement (FOA) Number DE-FOA-0001532, requesting proposals to develop and test a methodology for identifying the commercial energy code requirements that can provide the maximum cost-effective energy and cost savings through increased compliance. Awarded to the Institute for Market Transformation, this report summarizes the development and testing of a commercial code compliance methodology, including a summary of results, statistical analysis of sample, and best practices for others implementing a commercial energy code compliance field study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transforming Markets for Energy-Efficient Buildings in China: Final Report on Activity Conducted by the Institute for Market Transformation (IMT) Under Cooperative Agreement DE-FC01-00EE10672 with the U.S. Department of Energy (DOE)

This report summarizes activity conducted by the Institute for Market Transformation and a team of American and Chinese partners in development of a new building energy-efficiency code for the transitional climate zone in the People's Republic of China.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Impacts from Adopting the 2006 International Energy Conservation Code for Residential Buildings in Wyoming

The state of Wyoming currently does not have a statewide building energy efficiency code for residential buildings. The U.S. Department of Energy has requested Pacific Northwest National Laboratory (PNNL) to estimate the energy savings, economic impacts, and pollution reduction from adopting the 2006 International Energy Conservation Code (IECC). This report addresses the impacts for low-rise residential buildings only.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Standard 90.1-2007 and the 2009 IECC with Respect to Commercial Buildings

The U.S. Department of Energy’s (DOE’s) Building Energy Codes Program (BECP) has been asked by some states and energy code stakeholders to address the comparability of the 2009 International Energy Conservation Code® (IECC) as applied to commercial buildings and ANSI/ASHRAE/IESNA Standard 90.1-2007 (hereinafter referred to as Standard 90.1-07). An assessment of comparability will help states respond to and implement conditions specified in the State Energy Program (SEP) Formula Grants American Recovery and Reinvestment Act Funding Opportunity, Number DE-FOA-0000052, and eliminate the need for the states individually or collectively to perform comparative studies of the 2009 IECC and Standard 90.1-07. The funding opportunity announcement contains the following conditions: (2) The State, or the applicable units of local government that have authority to adopt building codes, will implement the following: (A) A residential building energy code (or codes) that meets or exceeds the most recent International Energy Conservation Code, or achieves equivalent or greater energy savings. (B) A commercial building energy code (or codes) throughout the State that meets or exceeds the ANSI/ASHRAE/IESNA Standard 90.1-2007, or achieves equivalent or greater energy savings . (C) A plan to achieve 90 percent compliance with the above energy codes within eight years. This plan will include active training and enforcement programs and annual measurement of the rate of compliance. With respect to item (B) above, many more states, regardless of the edition date, directly adopt the IECC than Standard 90.1-07. This is predominately because the IECC is a model code and part of a coordinated set of model building codes that state and local government have historically adopted to regulate building design and construction. This report compares the 2009 IECC to Standard 90.1-07 with the intent of helping states address whether the adoption and application of the 2009 IECC for commercial buildings can be considered equivalent to the adoption and application of Standard 90.1-07. Based on this document, states adopting the 2009 IECC, which is the document cited in (A), above, for residential construction, can also determine if they are in compliance with the above provisions for commercial buildings in (B) above and if their code meets or exceeds the ANSI/ASHRAE/IESNA Standard 90.1-07.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of the Performance of Various Correlated Fission Multiplicity Monte Carlo Codes

When measuring special nuclear material for a large array of national security needs, it is often important to accurately predict outcomes of the physical experiment using Monte Carlo radiation transport codes. Historically, radiation transport codes have uncorrelated fission emissions. In reality, both spontaneous and induced fissions release particles that are correlated in time, energy, and multiplicity. This work investigates the performance of various current Monte Carlo codes that take into account the correlated physics of fission neutrons. Only fission neutrons are of interest and the physics of gamma production in fission is ignored. Because of their large impact on correlated neutron results, underlying fission neutron multiplicity distributions utilized by the different codes are also compared. The codes currently being compared include MCNP{sup R}6, MCNP{sup R}6/FREYA, and MCNPX-PoliMi. By default, MCNP{sup R}6 uses a bounded integer treatment to sample the number of neutrons emitted from each fission event. The FMULT card, an optional input in MCNP that allows for user definition of spontaneous and induced fission parameters, can be utilized to call either built-in or user-specified multiplicities to replace the bounded integer treatment. Similarly, MCNPX-PoliMi utilizes one of a few different built-in multiplicity sets. MCNPX-PoliMi also models the multiplicity dependence of emitted neutron energy in spontaneous fission. It is possible to use an anisotropic model for emitted fission neutrons in MCNPXPoliMi, but this option was not used. For MCNP{sup R}6/FREYA, the FREYA fission event generator determines the number of particles emitted for each fission event and gives the results to MCNP{sup R}6 for transport. The fission event generator uses fission fragment mass and kinetic energy distributions, unbounded statistical evaporation models, and conservation of energy and momentum to generate the number, energy, and direction of neutrons released by each fission event. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Summary of Code Barriers: Summary of Code and Standard Barriers to the Implementation of High Performance Home Systems Designs

Building codes serve to ensure minimum requirements for safety, durability, and energy efficiency of homes. To enable innovation and to support continual improvement, building codes are updated on a 2-3 year basis to (1) include new methods of and/or materials for construction and (2), where needed, revise the current methods of construction to better meet the intent of the code. This report discusses issues of wind pressure resistance in walls with exterior rigid foam sheathing installed directly over framing members.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Country Report on Building Energy Codes in Japan

This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America (U.S.). This reports gives an overview of the development of building energy codes in Japan, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, and lighting) for commercial and residential buildings in Japan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ASME Code Case Development Strategy for Ferritic/Martensitic HT-9 Steel

The US Department of Energy (DOE), Office of Nuclear Energy (NE), is supporting the development of an ASME Code Case for adoption of 12Cr-1Mo-VW ferritic/martensitic (F/M) steel, commonly known as HT-9, primarily for use in design of liquid-metal fast reactors (LMFR) and components. In 2011, Los Alamos National Laboratory (LANL) nuclear engineering staff began assisting in the development of a small modular reactor (SMR) design concept, previously known as the Hyperion Module, now called the Gen4 Module, being developed by Gen4 Energy, Inc. located in Denver, Colorado. LANL engineering staff had initially proposed either T91 (9Cr-1Mo-VNb) or HT-9 for the reactor vessel and components, as well as fuel clad and ducting. Although T91 is currently an approved/authorized material for elevated temperature design in the ASME Code, the preference is utilization of HT-9 due to its extensive irradiation database and similar creep resistance as T91. In addition, HT-9 has relatively good corrosion properties for fast reactor environment, such as liquid lead bismuth eutectic coolant. Although the ASME material Code Case, for adoption of HT-9 as an approved elevated temperature material for LMFR service, is the ultimate goal of this project, several key deliverables have been accomplished in FY2012 to provide assurance to DOE/NE of the viability and feasibility of pursuing this goal. An important key deliverable was the recently completed, Gap Analysis of Material Properties Data for Ferritic/Martensitic HT-9 (1). This report provided a cursory research, accumulation, and documentation of specific material parameters; physical, mechanical, and environmental, which are necessary for ensuring a successful ASME Code Case. Time-independent tensile and ductility data and time-dependent creep and creep-rupture behavior are some of the material properties required for a successful ASME Code case. Unfortunately, results of the Gap Analysis report show that many of the material properties have limited data availability in open-source documentation, or are contained in Applied Technology documents, or there is insufficient data to support the ASME requirement from 3-separate heats of material.

36 MATERIALS SCIENCE↗