Search NASA⌕ Search

SEARCH · Search NASA

Results for “Utility Regulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Load Power Agnostic 6.6 kW Wireless EV Charger with LCL Tuned Primary and Secondary Side Regulation

Wireless charging of electric vehicles (EVs) is going to play a major role in electrification of transportation. This paper proposes to utilize an LCL tuned primary and series tuned secondary with a secondary buck regulator to achieve power transfer control by secondary side control only. Analytical expressions for base (primary) coil current and transformer turns ratio N required to transfer the required power at a certain input voltage is calculated for a given coil set. The required parameters are calculated for a 6.6 kW wireless charging system with a matched circular coil set. The proposed control scheme and analysis were validated through Saber Sketch simulations and by a 6.6 kW laboratory prototype. Experimental results for different load power settings at voltages of 290 V, 340 V, and 370 V are presented.

Galigekere, Veda Prakash N.↗

Molecular Regulatory Mechanisms Drive Emergent Pathogenetic Properties of Neisseria gonorrhoeae

Neisseria gonorrhoeae is the causative agent of the sexually transmitted infection (STI) gonorrhea, with an estimated 87 million annual cases worldwide. N. gonorrhoeae predominantly colonizes the male and female genital tract (FGT). In the FGT, N. gonorrhoeae confronts fluctuating levels of nutrients and oxidative and non-oxidative antimicrobial defenses of the immune system, as well as the resident microbiome. One mechanism utilized by N. gonorrhoeae to adapt to this dynamic FGT niche is to modulate gene expression primarily through DNA-binding transcriptional regulators. Here, we describe the major N. gonorrhoeae transcriptional regulators, genes under their control, and how these regulatory processes lead to pathogenic properties of N. gonorrhoeae during natural infection. We also discuss the current knowledge of the structure, function, and diversity of the FGT microbiome and its influence on gonococcal survival and transcriptional responses orchestrated by its DNA-binding regulators. We conclude with recent multi-omics data and modeling tools and their application to FGT microbiome dynamics. Understanding the strategies utilized by N. gonorrhoeae to regulate gene expression and their impact on the emergent characteristics of this pathogen during infection has the potential to identify new effective strategies to both treat and prevent gonorrhea.

59 BASIC BIOLOGICAL SCIENCES↗

A study of power conditioning and power distribution and components

A comprehensive simulation and analysis performed on the operation of the regulator part of the Charger/Battery/Regulator Module (CBRM) are detailed. The CBRM is utilized as an integral component of the Skylab/Apollo Telescope Mount (ATM) electrical power system and contains a switching mode electronic regulator. Implementing circuit analysis techniques, pertinent voltages and currents are calculated; these, in turn, are incorporated into the regulator system study. Investigation of the turn-on and turn-off times associated with the switching circuitry is performed and an examination is made on these calculations. A simulation model computer program is utilized to generate graphs that relate various CBRM parameters to one another.

Horton, H. M.↗

Aging Effect Analysis of PV Inverter Semiconductors for Ancillary Services Support

PV inverters can provide reactive power while generating active power. An ongoing microgrid implementation at Duke Energy actively engages non-utility PVs to generate/absorb reactive power in support of ancillary services to increase microgrid resiliency during extreme events. PV systems are requested to provide reactive power support: 1) in response to grid voltage variation to better regulate the local voltage; or 2) in response to utility incentives, such as following Transactive Energy System (TES) incentives. However, providing ancillary services might shorten the lifetime expectation of PV inverter semiconductors. This paper summarizes the potential impacts on a PV inverter semiconductor's lifetime when providing ancillary services. The analysis presented in this research work shows that providing reactive power support will increase the mean junction temperature and the junction temperature variation of the inverter diodes. This increased junction temperature will eventually lead to shorter diode lifetime. The lifetime estimation of semiconductors is briefly reviewed. The power losses of PV inverter semiconductors are derived as a support analysis to the junction temperature calculation. In addition, the impact of the filtering inductor on the semiconductor current distribution is discussed. The theoretical analysis presented in this research work is supported by simulation results.

14 SOLAR ENERGY↗

Voltage Regulation Performance Evaluation of Distributed Energy Resource Management via Advanced Hardware-in-the-Loop Simulation

This paper evaluates the performance of coordinated control across advanced distribution management systems (ADMS), distributed energy resources (DERs), and distributed energy resource management systems (DERMS) using an advanced hardware-in-the-loop (HIL) platform. This platform provides a realistic laboratory testing environment, including accurate dynamic modeling of a real-world distribution system from a utility partner, real controllers (ADMS and DERMS), physical power hardware (DERs), and standard communications protocols. One grid service—voltage regulation—is evaluated to show the performance of the coordinated grid automation system. The testing results demonstrate that the coordinated DERMS and ADMS system can effectively regulate system voltages within target operation limits using DERs. The realistic laboratory HIL testing results give utilities confidence in adopting the grid automation systems to manage DERs to achieve system-level control and operation objectives (e.g., voltage regulation). This helps utilities mitigate potential risks (e.g., instability) prior to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Kölliker's Organ Functions as a Developmental Hub in Mouse Cochlea Regulating Spiral Limbus and Tectorial Membrane Development

Kölliker's organ is a transient developmental structure in the mouse cochlea that undergoes significant remodeling postnatally. Utilizing an epithelial-specific conditional deletion mouse model of Prdm16 (marker and regulator of Kölliker's organ), we show that Prdm16 is required for interdental cell development, and thereby the development of the limbal domain of the tectorial membrane and its medial anchorage to the spiral limbus. Additionally, we show that Kölliker's organ is involved in normal tectorial membrane collagen fibril development and maturation. Interestingly, mesenchymal cells of the spiral limbus underneath Prdm16 -deficient Kölliker's organ failed to produce interstitial matrix proteins, resulting in a hypoplastic and truncated spiral limbus, indicating a non-cell autonomous role of Prdm16 in regulating spiral mesenchymal matrix development. Single-cell RNA sequencing identified differentially expressed genes in Prdm16 -deficient Kölliker's organ suggesting a role for connective tissue growth factor (CTGF) downstream Prdm16 in epithelial-mesenchymal signaling involved in spiral limbus matrix deposition. Prdm16 -deficient mice showed a hearing deficit, as indicated by elevated auditory brainstem response thresholds at most frequencies, consistent with the cochlear structural defects. Both sexes were studied. This work establishes Prdm16 as a deafness gene in mice through its role in regulating Kölliker's organ development. Such understanding recognizes Kölliker's organ as a developmental hub regulating multiple surrounding cochlear structures.

Zhang, Hongji↗

State Indicators for Advancing Demand Flexibility and Energy Efficiency in Buildings - Part I [Slides]

This slide deck report identifies objectives and key indicators for state activities that advance demand flexibility in buildings — legislation, utility regulatory proceedings, executive orders and programs. It also illustrates progress to date and identifies trends, gaps, and opportunities. Part I of the report focuses on (1) demand response and (2) energy efficiency targeted to reduce peak demand or integrate with demand response. This section covers building energy codes, appliance and equipment standards, resource standards, utility planning, utility programs, advanced metering infrastructure and meter data, rate design, state programs, state energy planning, and related state policies and regulations. Part II of the report addresses traditional energy efficiency indicators, including utility and state programs, codes, and standards that support annual energy savings. See the additional links for an infographic, library of cited state documents on demand flexibility, and presentation to the NASEO-NARUC Grid-Interactive Efficient Buildings Working Group.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the Optimality of LinDist3Flow for Optimal Tap Selection of Step Voltage Regulators in Unbalanced Distribution Networks

The adoption of distributed energy resources such as photovoltaics (PVs) has increased dramatically during the previous decade. The increased penetration of PVs into distribution networks (DNs) can cause voltage fluctuations that have to be mitigated. One of the key utility assets employed to this end are step-voltage regulators (SVRs). It is desirable to include tap selection of SVRs in optimal power flow (OPF) routines, a task that turns out to be challenging because the resultant OPF problem is nonconvex with added complexities stemming from accurate SVR modeling. While several convex relaxations based on semi-definite programming (SDP) have been presented in the literature for optimal tap selection, SDP based schemes do not scale well and are challenging to implement in large-scale planning or operational frameworks. This paper deals with the optimal tap selection (OPTS) problem for wye-connected SVRs using linear approximations of power flow equations. Specifically, the LinDist3Flow model is adopted and the effective SVR ratio is assumed to be continuous- enabling the formulation of a problem called LinDist3Flow-OPTS, which amounts to a linear program. The scalability and optimality gap of LinDist3Flow-OPTS are evaluated with respect to existing SDP-based and nonlinear programming techniques for optimal tap selection in three standard feeders, namely, the IEEE 13-bus, 123-bus, and 8500-node DNs. For all DNs considered, LinDist3Flow-OPTS achieves an optimality gap of approximately 1% or less while significantly lowering the computational burden.

linear approximations↗

Assessing the Optimality of LinDist3Flow for Optimal Tap Selection of Step Voltage Regulators in Unbalanced Distribution Networks: Preprint

The adoption of distributed energy resources such as photovoltaics (PVs) has increased dramatically during the previous decade. The increased penetration of PVs into distribution networks (DNs) can cause voltage fluctuations that have to be mitigated. One of the key utility assets employed to this end are step-voltage regulators (SVRs). It is desirable to include tap selection of SVRs in optimal power flow (OPF) routines, a task that turns out to be challenging because the resultant OPF problem is nonconvex with added complexities stemming from accurate SVR modeling. While several convex relaxations based on semi-definite programming (SDP) have been presented in the literature for optimal tap selection, SDP based schemes do not scale well and are challenging to implement in large-scale planning or operational frameworks. This paper deals with the optimal tap selection (OPTS) problem for wye-connected SVRs using linear approximations of power flow equations. Specifically, the LinDist3Flow model is adopted and the effective SVR ratio is assumed to be continuous–enabling the formulation of a problem called LinDist3Flow-OPTS, which amounts to a linear program. The scalability and optimality gap of LinDist3Flow-OPTS are evaluated with respect to existing SDP-based and nonlinear programming techniques for optimal tap selection in three standard feeders, namely, the IEEE 13-bus, 123-bus, and 8500-node DNs. For all DNs considered, LinDist3Flow-OPTS achieves an optimality gap of approximately 1% or less while significantly lowering the computational burden.

linear approximations↗

Assessment of Commercial Building Lighting as a Frequency Regulation Resource

This paper evaluates the potential for automated lighting control as a resource for frequency regulation of the electric grid system in the context of current energy policies, economic incentives, and technological trends. The growing prevalence of renewable energy has increased the need for ancillary services to maintain grid frequency and stability. While demand side resources like heating, ventilating, and air-conditioning systems, as well as water treatment plants are already evaluated as regulation service providers, the potential application to electrical lighting systems has largely been ignored. Yet, aggregations of lighting systems that are retrofitted with intelligent controls could conceivably contribute to frequency regulation services with little impact on user comfort. To further explore the feasibility of lighting potential, this paper explores (1) how lighting control systems are limited by visual comfort perception and acceptability, (2) how such limitations impact the performance of the lighting system as an frequency regulation resource, and (3) how the market potential of lighting systems as demand side resources compares in different regional transmission organizations. Finally, the impact of developing technologies on the application of lighting systems for frequency regulation is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Validation of a 40kW, 480V Point-to-Point DC Interlinks for Controller-Agnostic, Interoperable Networked Microgrids

This paper presents the experimental validation of point-to-point dc-interlinks for interconnecting two solar-based, laboratory-scale AC microgrids. DC interlinks provide a solution to numerous technical and operational challenges encountered in networked microgrids, including precise power flow control, stable and fast synchronization, enhanced stability, and improved voltage and frequency regulation. By decoupling microgrids through power converters, dc-interlinks enable power exchange among microgrids that can be owned by different entities (such as communities, utilities, or universities) and managed by diverse microgrid controller vendors. This characteristic makes this dc-interlinks a promising solution for networking real-world microgrids. The presented point-to-point dc interlink utilizes two four-quadrant converters: a 40kW 3-phase ac/dc regulating the dc-link voltage to 800V, and a 3-phase dc/ac controlling power flow. These converters, connected via a 20-foot dc cable, interconnect two ac microgrids operating at 480V, each featuring energy storage, photovoltaic generation, and load emulation. Experimental validation employs commercially available off-the-shelf (COTS) converters and real-world data from solar-powered microgrids in Adjuntas, Puerto Rico. To the authors’ knowledge, this work provides the first at-scale experimental validation of dc-interlinks for networked ac microgrids using COTS inverters, demonstrating their practicality and effectiveness in addressing real-world operational challenges.

Ferrari Maglia, Max [ORNL]↗

De novo transcriptome sequencing of Capsicum frutescens . L and comprehensive analysis of salt stress alleviating mechanism by Bacillus atrophaeus WU ‐9

Abstract Salt stress, as one of the most severe environmental stresses, can cause a series of changes in plants. However, the explanation of plant salt stress alleviating mechanism of plant growth–promoting rhizobacteria (PGPR) was hindered by the limited availability of transcriptomic information for salt stress‐treated plants grown in a microorganism‐controlled environment. Our previous reports have selected Bacillus atrophaeus WU‐9 as PGPR significantly alleviating pepper ( Capsicum frutescens . L) salt stress. In this work, the RNA‐seq analysis of salt stress‐treated and untreated plants, grown with and without WU‐9 in a microorganism‐controlled environment, was used to reveal the plant salt stress alleviating mechanisms of WU‐9. Twelve sequencing libraries, prepared by treating with WU‐9 and salt (150 mM NaCl for 36 h), were constructed by RNA‐Seq technique. Non‐inoculated seedlings mainly respond to salt stress through regulation of signal transduction, such as ethylene‐activated signaling pathway, signaling and cell communication, etc. And ethylene signal participated in salt stress response in pepper through regulating defense responses, fruit ripening and senescence. WU‐9 inoculation under salt stress mainly improves salt tolerance and plant growth by regulating salt stress‐responding ethylene and auxin signal transduction, utilization of proline, photosynthesis, antioxidant enzyme activities and cell enlargement. Furthermore, 86 differentially expressed genes and 20 transcription factors were identified as associated with salt stress response and tolerance. Thus, this innovative transcriptomic study identified the salt stress response and alleviation in C. frutescens . L with PGPR inoculation. This result provided novel insights into the salinity alleviation in pepper regulated by PGPR.

Wang, Wenfei↗

Leveraging Pre-Built Catalogs and Object-Level Scheduling to Eliminate I/O Bottlenecks in HPC Environments

Modern High-Performance Computing (HPC) environments face mounting challenges due to the shift from large to small file datasets, along with an increasing number of users and parallelized applications. As HPC systems rely on Parallel File Systems (PFS), such as Lustre for data processing, performance bottlenecks stemming from Object Storage Target (OST) contention have become a significant concern. Existing solutions, such as LADS with its object-level scheduling approach, fall short in large-scale HPC environments due to their inability to effectively address metadata I/O bottlenecks and the growing number of I/O processes. This study highlights the pressing need for a comprehensive solution that tackles both OST contention and metadata I/O challenges in diverse HPC workloads. To address these challenges, we propose SwiftLoad, an object-level I/O scheduling framework that leverages a metadata catalog to enhance the performance and efficiency of parallel HPC utilities. The adoption of the metadata catalog mitigates the metadata I/O bottlenecks that commonly occur in HPC utilities, a challenge that is particularly pronounced in object-level I/O scheduling. SwiftLoad addresses OST contention and the uneven distribution of I/O processes across different OSTs through mathematical modeling and incorporates a Loader Configuration Module to regulate the number of I/O processes. Evaluated with two representative utilities—data deduplication profiling and data augmentation—SwiftLoad achieved performance improvements of up to 5.63x and 11.0x, respectively, on a production supercomputer.

HPC↗

A Review of Classical Swine Fever Virus and Routes of Introduction into the United States and the Potential for Virus Establishment

Classical swine fever (CSF) is caused by CSF virus (CSFV) which can be the source of substantial morbidity and mortality events in affected swine. The disease can take one of several forms (acute, chronic, or prenatal) and depending on the virulence of the inoculating strain may result in a lethal infection irrespective of the form acquired. Because of the disease-free status of the United States and the high cost of a viral incursion, a summary of US vulnerabilities for viral introduction and persistence is provided. The legal importation of live animals as well as animal products, byproducts, and animal feed serve as a potential route of viral introduction. Current import regulations are described as are mitigation strategies that are commonly utilized to prevent pathogens, including CSFV, from entering the US. The illegal movement of suids and their products as well as an event of bioterrorism are both feasible routes of viral introduction but are difficult to restrict or regulate. Ultimately, recommendations are made for data that would be useful in the event of a viral incursion. Population and density mapping for feral swine across the United States would be valuable in the event of a viral introduction or spillover; density data could further contribute to understanding the risk of infection in domestic swine. Additionally, ecological and behavioral studies, including those that evaluate the effects of anthropogenic food sources that support feral swine densities far above the carrying capacity would provide invaluable insight to our understanding of how human interventions affect feral swine populations. Further analyses to determine the sampling strategies necessary to detect low levels of antibody prevalence in feral swine would also be valuable.

Veterinary Sciences↗

Grid Integration of Small-Scale Photovoltaic Systems in Secondary Distribution Network—A Review

The relative share of renewable energy, specifically the solar photovoltaic (PV), is increasing exponentially in the world electric energy sector. This is a cumulative result of reduction in the cost of solar panels, improvement in the panel efficiency, and advancement in the associated power electronics. Among different types of PV plants, installation of small-scale rooftop PV is growing rapidly due to direct end-user benefits and lucrative governmental incentives. There are various standards developed in regards to grid integration of PVs and other distributed generations (DGs). Different power converter topologies are developed to interface the PV panel with the utility grid. To keep up with the stringent regulations imposed by the standards, various control strategies and grid synchronization methods have been developed. This review article amalgamates and summarizes all of the aforementioned aspects of a grid-integrated PV system including various standards, power stage architectures, grid synchronization methods, operation under extreme events, and control methodologies, pertaining to small-scale PV plants. This article will help freshman researchers to gain some familiarity with the topic and introduce them to some of the key issues encountered in this field.

14 SOLAR ENERGY↗

Transcriptome architecture of the three main lineages of agrobacteria

ABSTRACT Agrobacteria are a diverse, polyphyletic group of prokaryotes with multipartite genomes capable of transferring DNA into the genomes of host plants, making them an essential tool in plant biotechnology. Despite their utility in plant transformation, genome-wide transcriptional regulation is not well understood across the three main lineages of agrobacteria. Transcription start sites (TSSs) are a necessary component of gene expression and regulation. In this study, we used differential RNA-seq and a TSS identification algorithm optimized on manually annotated TSS, then validated with existing TSS to identify thousands of TSS with nucleotide resolution for representatives of each lineage. We extend upon the 356 TSSs previously reported in Agrobacterium fabrum C58 by identifying 1,916 TSSs. In addition, we completed genomes and phenotyping of Rhizobium rhizogenes C16/80 and Allorhizobium vitis T60/94, identifying 2,650 and 2,432 TSSs, respectively. Parameter optimization was crucial for an accurate, high-resolution view of genome and transcriptional dynamics, highlighting the importance of algorithm optimization in genome-wide TSS identification and genomics at large. The optimized algorithm reduced the number of TSSs identified internal and antisense to the coding sequence on average by 90.5% and 91.9%, respectively. Comparison of TSS conservation between orthologs of the three lineages revealed differences in cell cycle regulation of ctrA as well as divergence of transcriptional regulation of chemotaxis-related genes when grown in conditions that simulate the plant environment. These results provide a framework to elucidate the mechanistic basis and evolution of pathology across the three main lineages of agrobacteria. IMPORTANCE Transcription start sites (TSSs) are fundamental for understanding gene expression and regulation. Agrobacteria, a group of prokaryotes with the ability to transfer DNA into the genomes of host plants, are widely used in plant biotechnology. However, the genome-wide transcriptional regulation of agrobacteria is not well understood, especially in less-studied lineages. Differential RNA-seq and an optimized algorithm enabled identification of thousands of TSSs with nucleotide resolution for representatives of each lineage. The results of this study provide a framework for elucidating the mechanistic basis and evolution of pathology across the three main lineages of agrobacteria. The optimized algorithm also highlights the importance of parameter optimization in genome-wide TSS identification and genomics at large.

59 BASIC BIOLOGICAL SCIENCES↗

Elucidating Arsenic and Selenium Speciation in Coal Fly Ashes

Coal fly ash (CFA) is produced during the coal combustion process and contains trace elements (<100 ppm) including selenium (Se) and arsenic (As), both detrimental for environmental and human health. Existing management strategies for CFAs involve disposal in landfills and ash ponds, as well as beneficial usage in other applications such as in concrete. Both the direct disposal and beneficial usage of CFA raise concerns for environmental hazards due to the potential leaching of Se and As. CFAs were classified as reusable material by the U.S. Environmental Protection Agency (EPA) with the first federal regulation (Disposal of Coal Combustion Residuals from Electric Utilities, CCR) for its disposal established six years ago. During coal combustion process, parameters such as furnace firing type, emissions controls, coal rank, use of additives, and particulate matter controls, could contribute to significant variability in As/Se concentrations and their speciation. Although there have been a handful of studies on As/Se speciation on small sets of samples, they do not fully represent the current state of coal-fired electrical generating units. Little information exists on the detailed speciation (e.g. oxidation state, complexation state) of As/Se in large set of fly ash samples. To better investigate the role of the potential contributing parameters, a large-scale survey study with representative samples of typical coal source and combustion conditions is highly desired. The overall goal of this research is to systematically characterize As and Se speciation of representative coal fly ash samples using state-of-the-art synchrotron based spectroscopic and microscopic techniques, in order to develop a correlation between coal source/type, operation condition, As/Se speciation, and As/Se mobility. A detailed survey study was conducted documenting the current state-of-knowledge on fossil power generating units as a function of coal type/source, operating conditions, environmental control systems, additive use, and fly ash handling methods. Based on this survey, a matrix of fly ash samples representing a range of conditions were chosen and collected. The collected ash samples were analyzed for bulk characteristics such as elemental composition, microstructure, chemical and mineralogical composition, surface area, and particle size distribution. State-of-the-art synchrotron X-ray microscopy and spectroscopy techniques were applied to reveal the molecular scale speciation information of As and Se, such as oxidation state, association with other elements/minerals, and complexation states.

01 COAL, LIGNITE, AND PEAT↗

Integration of SPS with utility system networks

The integration of Satellite Power System (SPS) power in electric utility power systems is discussed. Specifically, the nature of the power output variations from the spacecraft to the rectenna, the operational characteristics of the rectenna power, and the impacts on the electric utility system from utilizing SPS power to serve part of the system load are treated. It is concluded that if RF beam control is an acceptable method for power control, and that the site distribution of SPS rectennas do not cause a very high local penetration (40 to 50%), SPS may be integrated into electric utility system with a few negative impacts. Increased regulating duty on the conventional generation, and a potential impact on system reliability for SPS penetration in excess of about 25% appear to be two areas of concern.