Search NASA⌕ Search

SEARCH · Search NASA

Results for “VALVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Novel Active Combustion Control Valve

This project presents an innovative solution for active combustion control. Relative to the state of the art, this concept provides frequency modulation (greater than 1,000 Hz) in combination with high-amplitude modulation (in excess of 30 percent flow) and can be adapted to a large range of fuel injector sizes. Existing valves often have low flow modulation strength. To achieve higher flow modulation requires excessively large valves or too much electrical power to be practical. This active combustion control valve (ACCV) has high-frequency and -amplitude modulation, consumes low electrical power, is closely coupled with the fuel injector for modulation strength, and is practical in size and weight. By mitigating combustion instabilities at higher frequencies than have been previously achieved (approximately 1,000 Hz), this new technology enables gas turbines to run at operating points that produce lower emissions and higher performance.

Caspermeyer, Matt↗

Normally-Closed Zero-Leak Valve with Magnetostrictive Actuator

A non-pyrotechnic, normally-closed, zero-leak valve is a replacement for the pyrovalve used for both in-space and launch vehicle applications. The valve utilizes a magnetostrictive alloy for actuation, rather than pyrotechnic charges. The alloy, such as Terfenol-D, experiences magnetostriction, i.e. a gross elongation, when exposed to a magnetic field. This elongation fractures a parent metal seal, allowing fluid flow through the valve. The required magnetic field is generated by redundant coils that are isolated from the working fluid.

Ramspacher, Daniel J.↗

Development Specification for RV-346/348 Positive Pressure Relief Valves (PPRV)

This specification establishes the requirements for design, performance, safety, testing, and manufacture of the RV-346 and RV-348, Positive Pressure Relief Valve (PPRV) as part of the Advanced Extravehicular Mobility Unit (EMU)(AEMU) Portable Life Support System (PLSS). The RV-346 serves as the Positive Pressure Relief Valve (PPRV), and the RV-348 serves as the Secondary Positive Pressure Relief Valve (SPPRV).

PPR↗

Survival after aortic valve replacement for severe aortic stenosis with low transvalvular gradients and severe left ventricular dysfunction

OBJECTIVE: We sought to assess whether aortic valve replacement (AVR) among patients with severe aortic stenosis (AS), severe left ventricular (LV) dysfunction and a low transvalvular gradient (TVG) is associated with improved survival. BACKGROUND: The optimal management of patients with severe AS with severe LV dysfunction and a low TVG remains controversial. METHODS: Between 1990 and 1998, we evaluated 68 patients who underwent AVR at our institution (AVR group) and 89 patients who did not undergo AVR (control group), with an aortic valve area < or = 0.75 cm(2), LV ejection fraction < or = 35% and mean gradient < or = 30 mm Hg. Using propensity analysis, survival was compared between a cohort of 39 patients in the AVR group and 56 patients in the control group. RESULTS: Despite well-matched baseline characteristics among propensity-matched patients, the one- and four-year survival rates were markedly improved in patients in the AVR group (82% and 78%), as compared with patients in the control group (41% and 15%; p < 0.0001). By multivariable analysis, the main predictor of improved survival was AVR (adjusted risk ratio 0.19, 95% confidence interval 0.09 to 0.39; p < 0.0001). The only other predictors of mortality were age and the serum creatinine level. CONCLUSIONS: Among select patients with severe AS, severe LV dysfunction and a low TVG, AVR was associated with significantly improved survival.

NASA Discipline Cardiopulmonary↗

Percutaneous transluminal alcohol septal myocardial ablation after aortic valve replacement

When left ventricular outflow tract obstruction develops after aortic valve replacement, few treatment choices have been available until now. We present a patient with prior aortic valve replacement who developed left ventricle outflow tract obstruction that was successfully treated with a percutaneous transcoronary myocardial septal alcohol ablation. This technique is a useful tool for the treatment of obstructive hypertrophic cardiomyopathy, especially in those patients with prior heart surgery. Copyright 2001 Wiley-Liss, Inc.

Non-NASA Center↗

Finite Element Analysis of the Microisolation Valve

Agenda: Design and Use of the Microisolation Valve; Geometry of the Microisolation Valve; FEA Model Objectives; Results of the 10 and 50 microns Thick Wall Models; Results of the Thermally-Induced Stresses.

Microisolation Valve Finite Element Thermally-Indu↗

Phosphoribosylpyrophosphate synthetase as a metabolic valve advances Methylobacterium/Methylorubrum phyllosphere colonization and plant growth

The proficiency of phyllosphere microbiomes in efficiently utilizing plant-provided nutrients is pivotal for their successful colonization of plants. The methylotrophic capabilities of Methylobacterium/Methylorubrum play a crucial role in this process. However, the precise mechanisms facilitating efficient colonization remain elusive. In the present study, we investigate the significance of methanol assimilation in shaping the success of mutualistic relationships between methylotrophs and plants. A set of strains originating from Methylorubrum extorquens AM1 are subjected to evolutionary pressures to thrive under low methanol conditions. A mutation in the phosphoribosylpyrophosphate synthetase gene is identified, which converts it into a metabolic valve. This valve redirects limited C1-carbon resources towards the synthesis of biomass by up-regulating a non-essential phosphoketolase pathway. These newly acquired bacterial traits demonstrate superior colonization capabilities, even at low abundance, leading to increased growth of inoculated plants. This function is prevalent in Methylobacterium/Methylorubrum strains. In summary, our findings offer insights that could guide the selection of Methylobacterium/Methylorubrum strains for advantageous agricultural applications.

59 BASIC BIOLOGICAL SCIENCES↗

Development of Engine Valve Materials for Next Generation Higher Efficiency Engines

The growing demand to increase the performance and efficiency of light-, medium-, and heavy-duty engines continues to drive increases in combustion intensities and cylinder pressures, which result in higher exhaust gas temperatures. Thus, there is a critical need for new materials that can meet the performance and cost targets for components such as exhaust valves which are exposed to these higher exhaust gas temperatures. Oak Ridge National Laboratory (ORNL) has developed several lower-cost, high-strength alloys that have the potential to be adopted into intake and/or exhaust valves in the next generation, high-efficiency engines and other high temperature applications. These alloys are covered by two issued patents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Two-part valve acts as quick coupling

A two-part valve simplifies the problem of filling large tanks from smaller ones. One part acts as a check valve and remains integral to the recipient system, while the other part is integral to the donor system.

Source record↗

Valve designed with elastic seat

Absolute valve closure is accomplished by a machined valve with an axially annular channel which changes the outlet passage into a thin tubular elastic seat member with a retainer backup ring. The elasticity of the seat provides tight conformity to ball irregularity.

Mac Glashan, W. F., Jr.↗

Flow control valve is independent of pressure drop

Remote control of fluid flow in a low-power system is established by a flow control valve with a flapper and nozzle flow control. Constant rates are maintained despite fluctuating pressure across the valve.

Source record↗

Ring valve responds to differential pressure changes

Pressure valve has a moving annular ring seal that automatically reacts to differential pressure changes across the seat. This valve has good potential for the petroleum and chemical industries.

Source record↗

Cryogenic trap valve has no moving parts

Aluminum-body trap valve with an invar stem keeps cryogenic materials in the liquid state while entering the final component of a system. The valve has no moving parts and is self-actuated and self-monitoring.

Branum, L. W.↗

Soft-seal valve holds hazardous fluids safely

Valve assembly allows transfer of hazardous or reactive fluids such as liquid fluorine without corrosion of valve face and seat material. The assembly consists of a plug to block bulk flow and a soft-seal outer seat to effect zero-leak stoppage.

Source record↗

Quick-closing valve is actuated by explosive discharge

Remotely controlled plug-type valve shuts off a high-pressure, high-temperature gas flow in a few milliseconds. The valve is actuated by a commercially available electrically initiated squib of low explosive power. More rapid closure is attainable with squibs containing heavier explosive changes.

Majeski, S. J.↗

Gas-injection valve operates at high speed

Fast acting gas valve is used for injecting a short pulse of gas into a vacuum chamber during plasma acceleration experiments. It contains a lightweight closure disk that is forced away from the valve seat when an electromagnetic coil is momentarily energized and immediately rebounds from a stop back onto the seat.

Hoh, F. C.↗