Search NASA⌕ Search

SEARCH · Search NASA

Results for “VIIRS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Harnessing CPF Hyperspectral Radiances to Homogenize Earth Observing Systems

Homogenization across Earth observing systems is essential for ensuring consistency in geophysical retrievals over time and enabling the construction of long-term climate records. As the first SI Traceable Satellite (SITSat) for the reflected solar, the CLARREO Pathfinder (CPF) will provide high-accuracy spectrally resolved benchmark measurements of Earth-reflected solar radiation, serving as a standardized in-orbit reference for other reflected solar (RS) instruments. The CPF intercalibration team has developed a state-of-the-art method to intercalibrate the RS channels of the VIIRS instrument onboard the NOAA-20 satellite using CPF benchmark measurements, aiming for a methodology uncertainty of 0.3-0.6% (1-sigma). To achieve this stringent accuracy, the CPF team has devised strategies to mitigate the effects of spatial, spectral, polarization, and angular disparities between the intercalibration footprints of CPF and VIIRS. Despite nearly identical instrument designs, the three VIIRS instruments currently in operation onboard SNPP, NOAA-20, and NOAA-21 platforms exhibit systematic radiometric biases up to 8%. Although each VIIRS sensor’s calibration is independent and traceable to standards maintained by NIST, there is significant concern within the community about which VIIRS sensor most accurately represents the absolute radiometric scale. The precise intercalibration between CPF and NOAA-20 VIIRS will reveal the absolute radiometric accuracy of VIIRS. This accuracy can then be extended to other RS sensors, including MODIS and other VIIRS sensors, via vicarious methods. The 3-nm spectral sampling of CPF measurements will enable users to quantify scene-dependent spectral biases between sensors, thereby aiding in establishing both spectral and radiometric homogenization across these platforms. The CPF mission overview, along with details of its intercalibration capabilities and homogenization approaches, will be discussed at the meeting.

Raj Bhatt↗

Early On-Orbit Performance of the Visible Infrared Imaging Radiometer Suite Onboard the Suomi National Polar-Orbiting Partnership (S-NPP) Satellite

The Visible Infrared Imaging Radiometer Suite (VIIRS) is one of the key environmental remote-sensing instruments onboard the Suomi National Polar-Orbiting Partnership spacecraft, which was successfully launched on October 28, 2011 from the Vandenberg Air Force Base, California. Following a series of spacecraft and sensor activation operations, the VIIRS nadir door was opened on November 21, 2011. The first VIIRS image acquired signifies a new generation of operational moderate resolution-imaging capabilities following the legacy of the advanced very high-resolution radiometer series on NOAA satellites and Terra and Aqua Moderate-Resolution Imaging Spectroradiometer for NASA's Earth Observing system. VIIRS provides significant enhancements to the operational environmental monitoring and numerical weather forecasting, with 22 imaging and radiometric bands covering wavelengths from 0.41 to 12.5 microns, providing the sensor data records for 23 environmental data records including aerosol, cloud properties, fire, albedo, snow and ice, vegetation, sea surface temperature, ocean color, and nigh-time visible-light-related applications. Preliminary results from the on-orbit verification in the postlaunch check-out and intensive calibration and validation have shown that VIIRS is performing well and producing high-quality images. This paper provides an overview of the onorbit performance of VIIRS, the calibration/validation (cal/val) activities and methodologies used. It presents an assessment of the sensor initial on-orbit calibration and performance based on the efforts from the VIIRS-SDR team. Known anomalies, issues, and future calibration efforts, including the long-term monitoring, and intercalibration are also discussed.

viirs↗

Evaluation of Spectral Band Adjustment Factors for Cross-Calibration of Visible Imagers

The CERES EBAF dataset provides TOA SW and LW fluxes for long-term monitoring of the Earth’s energy balance and to validate climate models. The EBAF products, based on the Terra and Aqua CERES instrument observed radiances, rely on coincident measurements from the onboard MODIS imagers to determine cloud properties that are used in the angular distribution model scene selection required to convert the CERES observed radiances into flux values. Once the Terra and Aqua orbits start drifting outside of their 15-minute window, the CERES project will rely solely on the NOAA-20 CERES observations. A seamless transition of fluxes and clouds can only occur if the analogous MODIS and VIIRS channels are properly inter-calibrated. The visible band (0.65 µm) in MODIS (band 1) and VIIRS (M5 or I1) is critical for retrieving the cloud mask and optical depth. The spectral response functions (SRF) of these bands differ noticeably and will require scene dependent spectral band adjustment factors (SBAF) for proper radiometric scaling between them. Fortunately, the VIIRS I1 and M5 bands are calibrated using the same solar diffuser as a reference, which implies that band reflectance differences must be due to the spectral disparity. The coincident I1 and M5 TOA reflectance measurements provide the optimal opportunity to validate SBAFs over many surface and cloud conditions. The CERES project maintains SCIAMACHY, GOME-2, Hyperion, and radiative transfer model-based scene-stratified hyper-spectral reflectance measurements that can be convolved with sensor pair SRFs to compute the corresponding SBAF. This study will evaluate the SCIAMACHY, GOME-2, Hyperion, and RTM based SBAFs over tropical ocean targets used in SNO inter-calibration of MODIS and VIIRS, including clear-sky ocean, deep convective clouds (DCC), and liquid cloud targets in terms of their applicability to absolute intercomparison of visible imagers. The large SCIAMACHY and GOME-2 footprints and the lack of Hyperion cloudy scenes will impact the resulting SBAFs and necessitates the need for future CLARREO hyper-spectral reflectances to decrease SBAF uncertainties Preliminary results indicate that the SCIAMACHY and GOME-2 based SBAFs for the VIIRS I1 and M5 band pairs may differ by 1.5% for some ATO scene types. Because most of the modern GEOs visible band SRFs encompass the VIIRS I1 band SRF, these evaluations are critical to ensure that the MODIS, VIIRS, and GEO clouds and fluxes are consistent. SBAFs for Libya-4, Dome-C and other Earth invariant target will also be evaluated.

D. R. Doelling↗

Prelaunch and On-Orbit Electronic Calibration for Earth Observing Instruments

"The Electronic Calibration (Ecal) tests are performed during various stages of instrument development to examinethe linearity of the instrument electronics. During this process, charges with stepwise increments are injected inthe analog electronics circuitry to generate a ramp signal that can be used to characterize any nonlinearities in theelectronics. The prelaunch characterization of MODIS (on the Terra and Aqua platforms) and VIIRS (on SNPP,JPSS-1 and JPSS-2) involved a regular evaluation of the electronics linearity using the Ecal tests. On orbit,the Ecal tests have been regularly performed over the mission for both the MODIS instruments to derive theelectronics gain and linearity. Unlike MODIS, the Ecal tests on the VIIRS instruments are performed on an as-needed basis. To date, no Ecal tests were performed for S-NPP VIIRS on orbit. The VIIRS instrument on JPSS-1(now NOAA 20) was launched on November 18, 2017. An Ecal test was performed to support the instrumentsinitial post-launch performance assessment. Shortly after the first on-orbit emissive band calibration, degradationin the instrument gain was observed for the LWIR bands (M15, M16 and I5). As a part of the investigationrelated to this anomaly, a second Ecal test was performed and results were compared with the prelaunch results.In this paper, we discuss the prelaunch Ecal tests and representative results from MODIS and VIIRS prelaunchcharacterization. Also, discussed are the on-orbit results from the two MODIS instruments as well as from therecently launched VIIRS instrument."

ECAL↗

TPSAS-NF1676L-27483-DND

scene to retrieve their microphysical properties. The Clouds and the Earth's Radiant Energy System (CERES) Project uses the infrared channels (6.72 Âμm, 7.33 Âμm, 13.3 Âμm,13.6 Âμm, 13.9 Âμm, and 14.2 Âμm) available on the Terra and Aqua Moderate Resolution Imaging Spectroradiometers (MODIS) to build its algorithms to retrieval cloud properties. Unfortunately, The Visible Infrared Imaging Radiometer Suite (VIIRS) on board Suomi-NPP (National Polar-Orbiting Partnership) lacks these particular measurements. While conducting research using VIIRS data, it is desirable to bring these data into the VIIRS resolution. The Cross-track Infrared Sounder (CrIS), which is also on board Suomi-NPP, has these infrared channels. This paper describes a method to map the CrIS spectral radiances of CO2 and water vapor to VIIRS, with the mapping software in ATOVS and AVHRR Pre-processing (AAPP) package provided by Satellite Application Facilities for Numerical Weather Prediction (NWP SAF). This method is validated comparing mapped10.763 Âμm from CrIS with M15 from VIIRS. The mapped CO2 and water vapor channels were then created and combined with the conventional VIIRS product, as well as compared against corresponding channels of Aqua MODIS instrument.

Yan Chen↗

Seasonal Surface Spectral Emissivity Derived From MODIS Data

Surface emissivity is essential for many remote-sensing applications including the retrieval of surface skin temperature from satellite-based infrared measurements, the determination of cloud detection thresholds, and the estimation of the surface longwave radiation emission, an important component of the energy budget of the surface-atmosphere interface. The CERES (Clouds and the Earth’s Radiant Energy System) Project is measuring broadband shortwave and longwave radiances and deriving cloud properties from the MODIS on Terra and Aqua and from the VIIRS on NOAA-19 and NOAA-20 orbiters to produce combined global radiation and cloud property data sets. Zhou et al. (IEEE Trans. Geosci. Remote Sens., 49, 2011) used Infrared Atmospheric Sounding Interferometer (IASI) data to create a high spectral resolution surface emissivity atlas for remote sensing and modeling applications. The IASI measures spectral radiances between 3.62 and 15.5 μm. The VIIRS I4 channel width is from 3.55 to 3.93 μm, while MODIS Band 20 is from 3.66 to 3.84 m. Comparisons of top-of-atmosphere (TOA) radiance calculations with MODIS and VIIRS observations for these bands relative to bands in the mid-infrared suggest that the IASI emissivity atlas near 3.7 µm may not be suitable for CERES cloud retrievals. In this paper, the IASI emissivities for the VIIRS and MODIS bands centered near 11m are used to derive surface skin temperature from nighttime MODIS/VIIRS data. The Goddard Earth Observing System for Instrument Teams (GEOS-IT) numerical weather analyses provide temperature and water vapor profiles fused to correct the observed radiances for atmospheric absorption and emission. Global seasonal emissivity maps are then derived for the VIIRS and MODIS 3.7-m bands that are consistent with the derived skin temperatures and the observed TOA radiances. These seasonal climatology maps are validated and will be used in CERES Edition 5 and other CERES-related cloud retrieval algorithms to provide improved clear-sky radiances and derived cloud properties.

Surface Emissivity↗

Correcting for Trace Gas Absorption When Retrieving Aerosol Optical Depth from Satellite Observations of Reflected Shortwave Radiation

Retrieving aerosol optical depth (AOD) from top-of-atmosphere (TOA) satellite measured radiance requires separating the aerosol signal from the total observed signal. Total TOA radiance includes signal from underlying surface and from atmospheric constituents such as aerosols, clouds and gases. Multispectral retrieval algorithms, such as the dark-target (DT) algorithm that operates upon Moderate Resolution Imaging Spectroradiometer (MODIS, onboard Terra and Aqua satellites) and Visible Infrared Imaging Radiometer Suite (VIIRS, onboard Suomi-NPP) sensors, use wavelength bands in "window" regions. However, while small, the gas absorptions in these bands are non-negligible and require correction. In this paper we use High-resolution TRANsmission (HITRAN) database and Line-by-Line Radiative Transfer Model (LBLRTM) to derive consistent gas corrections for both MODIS and VIIRS wavelength bands. Absorptions from H2O, CO2 and O3 are considered, as well as other trace gases. Even though MODIS and VIIRS bands are "similar", they are different enough that applying MODIS specific gas corrections to VIIRS observations results in an underestimate of global mean AOD (by 0.01), but with much larger regional AOD biases up to 0.07. As recent studies are attempting to create a long-term data record by joining multiple satellite datasets, including MODIS and VIIRS, the consistency of gas correction becomes even more crucial.

Satellite Remote Sensing↗

GEO-LEO Reflective Band Inter-Comparison with BRDF and Atmospheric Scattering Corrections

The inter-comparison of the reflective solar bands (RSB) between the instruments onboard a geostationary orbit satellite and a low Earth orbit satellite is very helpful in assessing their calibration consistency. Himawari-8 was launched 7 October 2014 and GOES-R was launched on 19 November 2016. Unlike previous GOES instruments, the Advanced Himawari Imager (AHI) on Himawari-8 and the Advanced Baseline Imager (ABI) on GOES-R have onboard calibrators for the RSB. Independent assessment of calibration is nonetheless important to enhance their product quality. MODIS (Moderate Resolution Imaging Spectroradiometer) and VIIRS (Visible Infrared Imaging Radiometer Suite) can provide good references for sensor calibration. In this work, the inter-comparison between AHI and VIIRS is performed over a pseudo-invariant target. The use of stable and uniform calibration sites provides comparison with accurate adjustment for band spectral difference, reduction of impact from pixel mismatching, and consistency of BRDF (Bidirectional Reflectance Distribution Function) and atmospheric correction. The site used is the Strzelecki Desert in Australia. Due to the difference in solar and view angles, two corrections must be applied in order to compare the measurements. The first is the atmospheric scattering correction applied to the top of atmosphere reflectance measurements. The second correction is applied to correct the BRDF effect. The atmospheric correction is performed using a vector version of the Second Simulation of a Satellite Signal in the Solar Spectrum (6SV) model and the BRDF correction is performed using a semi-empirical model. Our results show that AHI band 1 (0.47 microns) has a good agreement with VIIRS band M3 within 0.15 percent. AHI band 5 (1.61 microns) shows the largest difference (5.09 percent) with VIIRS band M10, while AHI band 5 shows the least difference (1.87 percent) in comparison with VIIRS band I3. The methods developed in this work can also be directly applied to assess GOES-16/ABI (Geostationary Operational Environment Satellite16 / Advanced Baseline Imager) calibration consistency, a topic we will address in the future.

The inter-comparison of the reflective solar bands↗

A Fast Visible-Infrared Imaging Radiometer Suite Simulator for Cloudy Atmopheres

A fast instrument simulator is developed to simulate the observations made in cloudy atmospheres by the Visible Infrared Imaging Radiometer Suite (VIIRS). The correlated k-distribution (CKD) technique is used to compute the transmissivity of absorbing atmospheric gases. The bulk scattering properties of ice clouds used in this study are based on the ice model used for the MODIS Collection 6 ice cloud products. Two fast radiative transfer models based on pre-computed ice cloud look-up-tables are used for the VIIRS solar and infrared channels. The accuracy and efficiency of the fast simulator are quantify in comparison with a combination of the rigorous line-by-line (LBLRTM) and discrete ordinate radiative transfer (DISORT) models. Relative errors are less than 2 for simulated TOA reflectances for the solar channels and the brightness temperature differences for the infrared channels are less than 0.2 K. The simulator is over three orders of magnitude faster than the benchmark LBLRTM+DISORT model. Furthermore, the cloudy atmosphere reflectances and brightness temperatures from the fast VIIRS simulator compare favorably with those from VIIRS observations.

VIIRS Instrument Simulator↗

Assessment of the Impact of Discontinuity in Satellite Instruments and Retrievals on Global PM2.5

Exposure to fine particulate matter (PM2.5) is the leading environmental risk factor for mortality globally. Satellite-derived estimates of surface PM2.5 developed from a combination of satellites, simulations, and ground monitor data are relied upon for health impact studies. The ability to develop satellite-derived PM2.5 estimates requires the continued availability of aerosol optical depth (AOD) sources. This work examines the impact of the addition or loss of satellite AOD data sources on global PM2.5 estimation and the impact of continuing the longterm record with AOD from the Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi-National Polar orbiting Partnership (S-NPP) satellite after the loss of the MODIS (MODerate resolution Imaging Spectroradiometer) and MISR (Multi-angle Imaging Spectroradiometer) instruments on board the Terra and Aqua satellites. We find that the addition of VIIRS S-NPP AOD products to geophysical PM2.5 estimates from satellites and simulations causes regional differences that correspond to differences in the VIIRS and MODIS Deep Blue AOD algorithms and sampling. Changes in long-term trends and timeseries due to the addition or loss of AOD data sources are generally within their uncertainties. Statistical fusion with ground monitor data partially corrects for changes due to sampling differences when introducing the VIIRS AOD products, but uncertainty remains over desert regions where ground monitor coverage is sparse. This work provides promise for the sustained development of global satellite-derived PM2.5 estimates, despite discontinuities in instruments and retrieval methods.

Remote sensing↗

A harmonized global nighttime light dataset 1992–2018

Nighttime light (NTL) data from the Defense Meteorological Satellite Program (DMSP)/Operational Linescan System (OLS) and the Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite provide a great opportunity for monitoring human activities from regional to global scales. Despite the valuable records of nightscape from DMSP (1992–2013) and VIIRS (2012–2018), the potential of the historical archive of NTL observations has not been fully explored because of the severe inconsistency between DMSP and VIIRS. In this study, we generated an integrated and consistent NTL dataset at the global scale by harmonizing the inter-calibrated NTL observations from the DMSP data and the simulated DMSP-like NTL observations from the VIIRS data. The generated global DMSP NTL time-series data (1992–2018) show consistent temporal trends. This temporally extended DMSP NTL dataset provides valuable support for various studies related to human activities such as electricity consumption and urban extent dynamics.

54 ENVIRONMENTAL SCIENCES↗

Suomi National Polar-Orbiting Partnership Visible Infrared Imaging Radiometer Suite Polarization Sensitivity Analysis

The Visible Infrared Imaging Radiometer Suite (VIIRS) is one of five instruments onboard the Suomi National Polar-Orbiting Partnership (SNPP) satellite that launched from Vandenberg Air Force Base, California, on October 28, 2011. It is a whiskbroom radiometer that provides +/-56.28deg scans of the Earth view. It has 22 bands, among which 14 are reflective solar bands (RSBs). The RSBs cover a wavelength range from 410 to 2250 nm. The RSBs of a remote sensor are usually sensitive to the polarization of incident light. For VIIRS, it is specified that the polarization factor should be smaller than 3% for 410 and 862 nm bands and 2.5% for other RSBs for the scan angle within +/-45deg. Several polarization sensitivity tests were performed prelaunch for SNPP VIIRS. The first few tests either had large uncertainty or were less reliable, while the last one was believed to provide the more accurate information about the polarization property of the instrument. In this paper, the measured data in the last polarization sensitivity test are analyzed, and the polarization factors and phase angles are derived from the measurements for all the RSBs. The derived polarization factors and phase angles are band, detector, and scan angle dependent. For near-infrared bands, they also depend on the half-angle mirror side. Nevertheless, the derived polarization factors are all within the specification, although the strong detector dependence of the polarization parameters was not expected. Compared to the Moderate Resolution Imaging Spectroradiometer on both Aqua and Terra satellites, the polarization effect on VIIRS RSB is much smaller.

Polar-Orbiting↗

NASA's Land, Atmosphere Near Real-Time Capability for EOS (LANCE): Delivering Data and Imagery to Meet the Needs of Near Real-Time Applications

NASA's Land, Atmosphere Near real-time Capability for EOS (LANCE) is a virtual system that provides near real-time EOS data and imagery from the AIRS, AMSR2, LIS (ISS), MISR, MLS, MODIS, MOPITT, OMI, OMPS, and VIIRS instruments, to meet the needs of scientists and application users interested in monitoring a wide variety of natural and man-made phenomena. NRT imagery from LANCE are available through NASA's Global Imagery Browse Services (GIBS), Worldview, FIRMS and most recently through Worldview Snapshots – a low band width application that has replaced the Rapid Response Subsets. Over the past year: data and imagery from the Lightning Imaging Sensor (LIS) on board the International Space Station (ISS), OMPS and VIIRS-Land have been added to LANCE. In the coming year LANCE will integrate the MODIS NRT Global Flood product, VIIRS Black Marble nighttime lights and Cloud Mask and Aerosol Dark Target from VIIRS Atmosphere. Here we provide a brief overview of LANCE, focusing on what's new and describing how these new data sets have been used to monitor lightning flashes, hurricanes and fires. For more information on LANCE visit: https://earthdata.nasa.gov/lance.

Davies, Diane↗

Determination of Response Versus Scan Angle for the NOAA-20 Visible Infrared Imaging Radiometer Suite Thermal Emissive Bands from Emissive Radiation Measurements During the Pitch Maneuver

The visible infrared imaging radiometer suite (VIIRS) is a key sensor onboard the newly launched (November 18, 2017) NOAA-20 satellite and the early launched Suomi National Polar-orbiting Partnership (SNPP) satellite. The two VIIRS sensors are nearly identical in design. Its onboard calibration components include a solar diffuser (SD) and a SD stability monitor for the reflective solar bands, a V-grooved blackbody for the thermal emissive bands (TEBs),and a space view port for background subtraction. These onboard calibrators are located at fixed scan angles. The response versus scan angle (RVS) of the VIIRS scan mirror was characterized prelaunch in lab-ambient conditions and is currently used to calibrate the on-orbit response for all scan angles relative to the calibrator's scan angle. A spacecraft-level pitch maneuver was scheduled during the initial intensive calibration and validation testing for both the NOAA-20 and SNPP. The pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of the scan angle, which can be used to characterize the TEBRVS. We analyze the NOAA-20 pitch maneuver data and assess the derived TEB RVS. A comparison between the RVS determined by the pitch maneuver observations and prelaunch lab measurements is conducted for each band, detector, and mirror side of the half-angle mirror.

Wu, Aisheng↗

A Machine Learning-Based Cloud Detection and Thermodynamic Phase Classification Algorithm using Passive Spectral Observations

We trained two Random Forest (RF) machine-learning models for cloud mask and cloud thermodynamic phase detection using spectral observations from VIIRS on Suomi NPP (SNPP). Observations from CALIOP were carefully selected to provide reference labels. The two RF models were trained for all-day and daytime-only conditions using a 4-year collocated VIIRS/CALIOP dataset from 2013 to 2016. Due to the orbit difference, the collocated CALIOP and SNPP VIIRS training samples cover a broad viewing zenith angle range, which is a great benefit to overall model performance. The all-day model uses 3 VIIRS infrared (IR) bands (8.6,11, and 12 μm) and the daytime model uses 5 Near-IR (NIR) and Shortwave-IR (SWIR) bands (0.86, 1.24, 1.38, 1.64 and 2.25 μm) together with the 3 IR bands to detect clear, liquid water, and ice cloud pixels. Up to 7 surface types, namely, ocean/water, forest, cropland, grassland, snow/ice, barren/desert, and shrubland, were considered separately to enhance performance for both models. Detection of cloudy pixels and thermodynamic phase with the two RF models were compared against collocated CALIOP products from 2017. It is shown that, with a conservative screening process that excludes the most challenging cloudy pixels for passive remote sensing, the two RF models have high accuracy rates in comparison with the CALIOP reference for both cloud detection and thermodynamic phase. Other existing SNPP VIIRS and Aqua MODIS cloud mask and phase products are also evaluated, with results showing that the two RF models and the MODIS MYD06 optical property phase product are the top 3 algorithms with respect to lidar observations during the daytime. During the nighttime, the RF all-day model works best for both cloud detection and phase, in particular for pixels over snow/ice surfaces. The present RF models can be extended to other similar passive instruments if training samples can be collected from CALIOP or other lidars. However, the quality of reference labels and potential sampling issues that may impact model performance would need further attention.

cloud detection↗

JPSS-1 ATMS Post-launch Active Geolocation Analysis

A NOAA-20 (N20) ATMS active geolocation test was performed around Jan. 2018 with 24 pre-selected coastline crossing scenes. After comprehensive analysis of ATMS stare data and the corresponding VIIRS data, the ATMS pitch, roll and yaw pointing angle errors are found from the nadir perpendicular, the nadir oblique shallow angle, and the off-nadir perpendicular coastline crossing data, respectively. In this study, we first determine the ATMS radiometric coastline crossing time by using the ATMS radiometric count data. Since the coastline can be located anywhere within one ATMS FOV from the passive (regular scanning) geolocation data, depending on the scan starting time, it is not a valid assumption for the inflection point being the same as the coastline location. Consequently, using the passive geolocation data to validate the sensor’s on-orbit pointing angle performance is limited. After finding the ATMS radiometric coastline crossing time from the ATMS data, we compare it with the VIIRS effective time stamp (see main text). Specifically the VIIRS M3, M4 & M5 (true color) & M15 and M16 bands (thermal) data have a much smaller footprint size. Using the differences of the ATMS and VIIRS (effective) coastlines crossing times, the N20 ATMS pitch, roll and yaw pointing angle errors are found to be -0.09o, -0.24o and 0.28o, respectively. To determine ATMS geolocation properly, these on-orbit pointing errors need to be corrected, adding to the ATMS SDR Processing Coefficient Table, and passed on to the operational geolocation processing code.

Active Geolocation↗

On the use of DSCOVR EPIC to monitor the visible calibration stability of polar orbiting imagers to improve the next edition of the CERES climate data record.

The NASA CERES project has provided the climate quality observed TOA and computed surface fluxes to the scientific community. CERES instruments are onboard the Terra, Aqua, NPP, and NOAA-20 spacecraft. CERES uses MODIS and VIIRS imagers to retrieve cloud properties needed to convert CERES footprint radiance observations into fluxes using empirically derived angular directional models obtained during early CERES record. CERES utilizes geostationary sensors to infer the regional diurnal fluxes in between Terra and Aqua CERES observations. The imagers are also used to radiometrically scale the geostationary sensors (GEO) radiances to the imager calibration reference to ensure that the GEO derived cloud properties and broadband TOA fluxes are consistent in both space and time. Both the imager and GEO retrieved cloud properties are used to compute the surface fluxes. The Aqua-MODIS, SNPP-VIIRS, and NOAA-20 VIIRS afternoon imagers will also need to be radiometrically scaled to the same common calibration reference. Although all three imagers employ onboard solar diffusers, the calibration is not consistent over time due to instrument anomalies and ageing of the onboard calibrators. The CERES imager and GEO calibration group (IGCG) has been tasked to remove the imager channel calibration drifts for the next CERES reprocessing effort. The team will rely primarily on deep convective clouds, desert, and polar ice invariant targets to monitor the imager channel stability. The team uses ray-matched radiance pairs to radiometrically scale the SNPP and NOAA-20 VIIRS sensors to Aqua-MODIS. The radiometric scaling is further validated using geostationary imagers as transfer radiometers. The DSCOVR satellite was launched on February 25, 2015 and orbits around the L1 Lagrange point directly between the Earth and the sun. The EPIC instrument onboard DSCOVR employs a CCD array to image the Earth approximately every 2-hours. The EPIC sensor contains no onboard calibration systems. However, multiple inter-calibration studies have shown that the EPIC imager is very stable in time. This is likely due to the DSCOVR satellite being located about a 1.5M km from the Earth, where very little Earth reflected solar radiation degrades the optics. The excellent radiometric stability of EPIC allows the CERES IGCG to utilize the EPIC observations as a stable reference for monitoring the calibration stability of the three afternoon imagers, as well as to validate the radiometric scaling factors between them. Examples of the imager relative calibration using EPIC before and after radiometric scaling will be shown along with the results from the use of invariant targets to remove imager calibration drifts.

DSCOVR-EPIC↗

Additional characterization of Libya-4 in support of post-launch vicarious calibration of satellite imagers

Libya-4 (28.55° N and 23.39° E) is one of the most characterized and utilized Pseudo Invariant Calibration Site (PICS) for post-launch radiometer drift monitoring and sensor pair radiometric scaling. Libya-4 is one of the driest and most reflective PICS located in an extensive sand dune region void of any vegetation with an elevation of 118 m. It is positioned near the northeast border with Egypt. With minimal cloud cover and the monthly mean precipitation of ~ 1mm, Libya-4 is one of the temporally, spectrally, and spatially stable CEOS recommended PICS and Cosnefroy et al. 1996 identified sites. The Libya-4 PICS has been extensively used for post-launch radiometric calibration and validation of high-, medium, and low-resolution satellite imagers, including Landsat, MODIS, VIIRS, and Meteosats. The CERES Imager and Geostationary Calibration Group (IGCG) at NASA LaRC utilizes Libya-4 to perform an independent assessment of the radiometric stability of the MODIS and VIIRS L1B products. The site is also used for absolute radiometric scaling between MODIS, VIIRS, and geostationary imagers to ensure consistent cloud and radiative flux retrievals. Multi-year Terra-MODIS, Aqua-MODIS , NPP-VIIRS and Metoesat-7 observations over Libya-4 show very similar TOA reflectance temporal variability. Although, the surface reflectance and atmospheric column varies seasonally, the inter-annual variability of the seasonal cycle should be small. Especially during 2013, the Libya-4 TOA reflectance was found to be greater than usual in all 4 satellite records. Preliminary comparisons with mean wind speed and aerosol optical depth (AOD) indicate that the year 2013 is marked by elevated levels of both conditions. The goal of this study is to tie the Libya-4 visible reflectance inter-annual variability with corresponding meteorological measurements to further improve the characterization of the site.

David R. Doelling↗