Search NASA⌕ Search

SEARCH · Search NASA

Results for “Variable Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Oscillatory Spreading and Inertia in Power Grids

The increase in variable renewable generators (VRGs) in power systems has altered the dynamics from a historical experience. VRGs introduce new sources of power oscillations, and the stabilizing response provided by synchronous generators (SGs, e.g., natural gas, coal, etc.), which help avoid some power fluctuations, will lessen as VRGs replace SGs. These changes have led to the need for new methods and metrics to quickly assess the likely oscillatory behavior for a particular network without performing computationally expensive simulations. This work studies the impact of a critical dynamical parameter - the inertia value - on the rest of a power system's oscillatory response to representative VRG perturbations. We use a known localization metric in a novel way to quantify the number of nodes responding to a perturbation and the magnitude of those responses. This metric allows us to relate the spread and severity of a system's power oscillations with inertia. We find that as inertia increases, the system response to node perturbations transitions from localized (only a few close nodes respond) to delocalized (many nodes across the network respond). We introduce a heuristic computed from the network Laplacian to relate this oscillatory transition to the network structure. We show that our heuristic accurately describes the spread of oscillations for a realistic power-system test case. Using a heuristic to determine the likely oscillatory behavior of a system given a set of parameters has wide applicability in power systems, and it could decrease the computational workload of planning and operation.

dynamical systems↗

Energy storage emerging: A perspective from the Joint Center for Energy Storage Research

Energy storage is an integral part of modern society. A contemporary example is the lithium (Li)-ion battery, which enabled the launch of the personal electronics revolution in 1991 and the first commercial electric vehicles in 2010. Most recently, Li-ion batteries have expanded into the electricity grid to firm variable renewable generation, increasing the efficiency and effectiveness of transmission and distribution. Important applications continue to emerge including decarbonization of heavy-duty vehicles, rail, maritime shipping, and aviation and the growth of renewable electricity and storage on the grid. This perspective compares energy storage needs and priorities in 2010 with those now and those emerging over the next few decades. The diversity of demands for energy storage requires a diversity of purpose-built batteries designed to meet disparate applications. Advances in the frontier of battery research to achieve transformative performance spanning energy and power density, capacity, charge/discharge times, cost, lifetime, and safety are highlighted, along with strategic research refinements made by the Joint Center for Energy Storage Research (JCESR) and the broader community to accommodate the changing storage needs and priorities. Innovative experimental tools with higher spatial and temporal resolution, in situ and operando characterization, first-principles simulation, high throughput computation, machine learning, and artificial intelligence work collectively to reveal the origins of the electrochemical phenomena that enable new means of energy storage. This knowledge allows a constructionist approach to materials, chemistries, and architectures, where each atom or molecule plays a prescribed role in realizing batteries with unique performance profiles suitable for emergent demands.

Trahey, Lynn↗

SUPERFLARES ON SOLAR-TYPE STARS OBSERVED WITH KEPLER II. PHOTOMETRIC VARIABILITY OF SUPERFLARE-GENERATING STARS: A SIGNATURE OF STELLAR ROTATION AND STARSPOTS

We performed simple spot-model calculations for quasi-periodic brightness variations of solar-type stars showing superflares using Kepler photometric data. Most of the superflare stars show quasi-periodic brightness modulations with a typical period of one to a few tens of days. Our results indicate that these brightness variations can be explained by the rotation of a star with fairly large starspots. Using the results of the period analysis, we investigated the relation between the energy and frequency of superflares and the rotation period. Stars with relatively slower rotation rates can still produce flares that are as energetic as those of more rapidly rotating stars although the average flare frequency is lower for more slowly rotating stars. We found that the energy of superflares is related to the total coverage of the starspot. The correlation between the spot coverage and the flare energy in superflares is similar to that in solar flares. These results suggest that the energy of superflares can be explained by the magnetic energy stored around the starspots.

79 ASTRONOMY AND ASTROPHYSICS↗

Long-pulse-width variable-wavelength chirped pulse generator and method

A device for creating an optic pulse with different wavelengths separated by time. A pump laser is configured to output energy to a dye cell which, responsive to the energy, outputs an optic pulse. Mirrors direct the optic pulse away from the dye cell towards a spectrograph. The spectrograph has an input and two or more outputs. The spectrograph receives and converts the optic pulse to a wavelength separated optic signal presented on the two or more outputs. A first optic cable has an input end and an output end. The input end receives a first output from the spectrograph. A second optic cable has an input end and an output end. The input end receives a second output from the spectrograph. The second optic cable is a different length than the first optic cable to establish a time shift between the signals exiting the first and second cable.

42 ENGINEERING↗

Demand Response and Energy Storage Integration Study

Demand response and energy storage resources present potentially important sources of bulk power system services that can aid in integrating variable renewable generation. While renewable integration studies have evaluated many of the challenges associated with deploying large amounts of variable wind and solar generation technologies, integration analyses have not yet fully incorporated demand response and energy storage resources. This report represents an initial effort in analyzing the potential integration value of demand response and energy storage, focusing on the western United States. It evaluates two major aspects of increased deployment of demand response and energy storage: (1) Their operational value in providing bulk power system services and (2) Market and regulatory issues, including potential barriers to deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demand Response and Energy Storage Integration Study

Demand response and energy storage resources present potentially important sources of bulk power system services that can aid in integrating variable renewable generation. While renewable integration studies have evaluated many of the challenges associated with deploying large amounts of variable wind and solar generation technologies, integration analyses have not yet fully incorporated demand response and energy storage resources. This report represents an initial effort in analyzing the potential integration value of demand response and energy storage, focusing on the western United States. It evaluates two major aspects of increased deployment of demand response and energy storage: (1) Their operational value in providing bulk power system services and (2) Market and regulatory issues, including potential barriers to deployment.

25 ENERGY STORAGE↗

Enabling Greater Penetration of Solar Power via the Use of CSP with Thermal Energy Storage

At high penetration of solar generation there are a number of challenges to economically integrating this variable and uncertain resource. These include the limited coincidence between the solar resource and normal demand patterns and limited flexibility of conventional generators to accommodate variable generation resources. Of the large number of technologies that can be used to enable greaterpenetration of variable generators, concentrating solar power (CSP) with thermal energy storage (TES) presents a number of advantages. The use of storage enables this technology to shift energy production to periods of high demand or reduced solar output. In addition, CSP can provide substantial grid flexibility by rapidly changing output in response to the highly variable net load created byhigh penetration of solar (and wind) generation. In this work we examine the degree to which CSP may be complementary to PV by performing a set of simulations in the U.S. Southwest to demonstrate the general potential of CSP with TES to enable greater use of solar generation, including additional PV.

14 SOLAR ENERGY↗

Alternative Energy Carriers: Unique Interfaces for Electrochemical Hydrogenic Transformations

Abstract The shift toward renewable energy generation sources, characterized by their non‐carbon emitting but variable nature, has spurred significant innovation in energy storage technologies. Advancements in foundational understanding from investments in basic science and clever engineering solutions, coupled with increasing industrial adoption, have resulted in a notable reduction in the cost of storing electricity from variable energy generation sources. These developments have paved the way for the exploration of new and innovative forms of energy storage that deviate from traditional technologies. In this perspective, it is posited that the progress made in energy storage research over recent years has opened the door to the development of energy carriers for technologies that are yet to be realized. To illustrate this concept, examples of alternative energy carriers are provided within the context of unique electrochemical interfaces for electrochemical hydrogenic transformations. The unique properties of these interfaces and electrochemical systems can be leveraged in ways not yet imagined, creating new possibilities for energy storage. A perspective on the progress and challenges for each interface as well as a general outlook for the advancement of energy carrier systems are provided.

25 ENERGY STORAGE↗

Potential impacts of climate change on wind and solar electricity generation in Texas

Wind and solar energy sources are climate and weather dependent, therefore susceptible to a changing climate. in this paper, we quantify the impacts of climate change on wind and solar electricity generation under high concentrations of greenhouse gases in Texas. We employ mid-twenty-first century climate projections and a high-resolution numerical weather prediction model to generate weather variables in the future and produce wind and solar generation time series. We find that mid-twenty-first century projections based on five global climate models agree on the multiyear average increases across Texas in direct normal irradiance, global horizontal irradiance, surface air temperature, and 100-m wind speed of up to 5%, 4%, 10%, and 1%, respectively. These changes lead to multiyear average relative changes across Texas of -0.6 to + 2.5% and of + 1.3 to + 3.5% in solar and wind capacity factors, respectively, with significant regional, seasonal, and diurnal differences. Areas with low solar resource show an increase in solar capacity factors but reductions in wind capacity factors. Areas with high solar resource show reductions in solar capacity factors. The spatial and temporal differences in our results highlight the importance of using high-resolution data sets to study the potential impacts of climate change on wind and solar power.

14 SOLAR ENERGY↗

NV Energy Large-Scale Photovoltaic Integration Study: Intra-Hour Dispatch and AGC Simulation

The uncertainty and variability with photovoltaic (PV) generation make it very challenging to balance power system generation and load, especially under high penetration cases. Higher reserve requirements and more cycling of conventional generators are generally anticipated for large-scale PV integration. However, whether the existing generation fleet is flexible enough to handle the variations and how well the system can maintain its control performance are difficult to predict. The goal of this project is to develop a software program that can perform intra-hour dispatch and automatic generation control (AGC) simulation, by which the balancing operations of a system can be simulated to answer the questions posed above. The simulator, named Electric System Intra-Hour Operation Simulator (ESIOS), uses the NV Energy southern system as a study case, and models the system’s generator configurations, AGC functions, and operator actions to balance system generation and load. Actual dispatch of AGC generators and control performance under various PV penetration levels can be predicted by running ESIOS. With data about the load, generation, and generator characteristics, ESIOS can perform similar simulations and assess variable generation integration impacts for other systems as well. This report describes the design of the simulator and presents the study results showing the PV impacts on NV Energy real-time operations.

Energy↗

Internally Generated and Externally Forced Multidecadal Oceanic Modes and Their Influence on the Summer Rainfall over East Asia

Abstract Interdecadal oceanic variabilities can be generated from both internal and external processes, and these variabilities can significantly modulate climate on global and regional scales, including the warming slowdown in the early twenty-first century and rainfall in East Asia. By analyzing simulations from a unique Community Earth System Model (CESM) Large Ensemble (CESM-LE) project, it is shown that the interdecadal Pacific oscillation (IPO) is primarily an internally generated oceanic variability, while the Atlantic multidecadal oscillation (AMO) may be an oceanic variability generated by internal oceanic processes and modulated by external forcing in the twentieth century. Although the observed relationship between IPO and the Yangtze–Huaihe River valley (YHRV) summer rainfall in China is well simulated in both the preindustrial control and the twentieth-century ensemble simulation, none of the twentieth-century ensemble members can reproduce the observed time evolution of both the IPO and YHRV rainfall because of the unpredictable nature of IPO on multidecadal time scales. On the other hand, although CESM-LE cannot reproduce the observed relationship between the AMO and Huanghe River valley (HRV) summer rainfall of China in the preindustrial control simulation, this relationship in the twentieth-century simulations is well reproduced, and the chance of reproducing the observed time evolution of both AMO and HRV rainfall is about 30%, indicating the important role of the interaction between the internal processes and the external forcing to realistically simulate the AMO and HRV rainfall.

54 ENVIRONMENTAL SCIENCES↗

Characterizing Current THD’s Dependency on Solar Irradiance and Supraharmonics Profiling for a Grid-Tied Photovoltaic Power Plant

The rapidly increasing distributed energy resources (DERs) in power systems are now getting interconnected to set community grid structures, where power quality will be a major concern. The grid-to-grid (G2G) bidirectional power transfer among the distribution microgrid will not be considered commercially feasible unless the upstream harmonics are under the limits. The aggregation of such harmonics, measured as total harmonic distortion (THD), is feared to be beyond tolerable limits with the progression of rooftop grid-tied PV-like installations. Hence, this THD needs to be characterized with DER generation end variables. In this work, the photovoltaic (PV) DERs’ dependency on environment variables such as irradiance was profiled in the context of generating and injecting harmonics into the grid. A mathematical model of a grid-tied three-phase PV DER was developed as part of this correlation characterization, matching the fundamental unit structure of a 1.4 MW solar canopy located on the Florida International University (FIU) Miami campus. To determine the qualitative association with produced THD patterns, the model was evaluated with various irradiance settings. A real-time digital simulation (RTDS) platform was used to verify it. Following this confirmation, sets of data from power quality meters at the point of common coupling and FIU field sensors were utilized to validate further the correlation model. The results showed that the grid current’s THD exhibited a high correlation with the irradiance profile and its variation over time. The early morning and late afternoon periods of the day, associated with a low irradiance, constantly had higher harmonics generated from the PV DER. The midday THD was rather rational with partial shadings, hence a geolocation-dependent factor. These findings were verified by an RTDS and validated by real field data. In quantifying the THD injected by a single DER at a high-frequency (2–150 kHz) supraharmonics (SH) level, a 3% peak increment in magnitude was observed from the high-fixed to the low-fixed irradiance profile. The correlation characteristics depicted that the hybrid microgrid suffered from a daytime-dependent harmonic insertion from the grid-tied DER. This is a global problem unless specific measures are taken to mitigate the harmonics. The electrically notorious higher-frequency SH was found to increase proportionally. The G2G power transfer can be limited because of the higher THD in the early morning and late afternoon, which will also worsen because the numbers of grid-tied PV DERs (i.e., rooftop solar and industrial solar) are likely to increase rapidly soon. The community grid structure can thus have a controlled harmonics filtration setup purposefully designed to address the findings of this work, which also fall within the scope of our future research.

14 SOLAR ENERGY↗

PV Ramping in a Distributed Generation Environment: A Study Using Solar Measurements; Preprint

Variability in Photovoltaic (PV) generation resulting from variability in the solar radiation over the PV arrays is a topic of continuing concern for those involved with integrating renewables onto existing electrical grids. The island of Lanai, Hawaii is an extreme example of the challenges that integrators will face due to the fact that it is a small standalone grid. One way to study thisproblem is to take high-resolution solar measurements in multiple locations and model simultaneous PV production for various sizes at those locations. The National Renewable Energy Laboratory (NREL) collected high-resolution solar data at four locations on the island where proposed PV plants will be deployed in the near future. This data set provides unique insight into how the solar radiationmay vary between points that are proximal in distance, but diverse in weather, due to the formation of orographic clouds in the center of the island. Using information about each proposed PV plant size, power output was created at high resolution. The team analyzed this output to understand power production ramps at individual locations and the effects of aggregating the production from all fourlocations. Hawaii is a unique environment, with extremely variable events occurring on a daily basis. This study provided an excellent opportunity for understanding potential worst-case scenarios for PV ramping. This paper provides an introduction to the datasets that NREL collected over a year and a comprehensive analysis of PV variability in a distributed generation scenario.

14 SOLAR ENERGY↗

Impact of Market Behavior, Fleet Composition, and Ancillary Services on Revenue Sufficiency

Revenue insufficiency, or the missing money problem, occurs when the revenues that generators earn from the market are not sufficient to cover both fixed and variable costs to remain in the market and/or justify investments in new capacity, which may be needed for reliability. The near-zero marginal cost of variable renewable generators further exacerbates these revenue challenges. Estimating the extent of the missing money problem in current electricity markets is an important, nontrivial task that requires representing both how the power system operates and how market participants behave. This paper explores the missing money problem using a production cost model that represented a simplified version of the Electric Reliability Council of Texas (ERCOT) energy-only market for the years 2012-2014. We evaluate how various market structures -- including market behavior, ancillary services, and changing fleet compositions -- affect net revenues in this ERCOT-like system. In most production cost modeling exercises, resources are assumed to offer their marginal capabilities at marginal costs. Although this assumption is reasonable for feasibility studies and long-term planning, it does not adequately consider the market behaviors that impact revenue sufficiency. In this work, we simulate a limited set of market participant strategic bidding behaviors by means of different sets of markups; these markups are applied to the true production costs of all gas generators, which are the most prominent generators in ERCOT. Results show that markups can help generators increase their net revenues overall, although net revenues may increase or decrease depending on the technology and the year under study. Results also confirm that conventional, variable-cost-based production cost simulations do not capture prices accurately, and this particular feature calls for proxies for strategic behaviors (e.g., markups) and more accurate representations of how electricity markets work. The analysis also shows that generators face revenue sufficiency challenges in this ERCOT-like energy-only market model; net revenues provided by the market in all base markup cases and sensitivity scenarios (except when a large fraction of the existing coal fleet is retired) are not sufficient to justify investments in new capacity for thermal and nuclear power units. Overall, the work described in this paper points to the need for improved behavioral models of electricity markets to more accurately study current and potential market design issues that could arise in systems with high penetrations of renewable generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Distributed Wind on Bulk Power System Operations in ISO-NE: Preprint

The work presented in this paper aims to study the impact of a range of penetration levels of distributed wind on the operation of the electric power system at the transmission level. This paper presents a case study on the power system in Independent System Operator New England. It is analyzed using PLEXOS, a commercial power system simulation tool. The results show that increasing the integration of distributed wind reduces total variable electricity generation costs, coal- and gas-fired electricity generation, electricity imports, and CO2 emissions, and increases wind curtailment. The variability and uncertainty of wind power also increases the start-up and shutdown costs and ramping of most conventional power plants.

17 WIND ENERGY↗