Search NASA⌕ Search

SEARCH · Search NASA

Results for “Visual Examination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Sustainable Immersive Visualization: A Tale of Two Visualization Labs

For large-scale immersive installations, sustainability is a challenge. This talk presents a comparative analysis of two immersive visualization laboratories, each following distinct trajectories. At the core of this discussion lies the question of what has made the NREL ESIF Insight Center a sustainable success for the last decade. Our examination encompasses three pivotal ingredients: the right funding model, the right usage model, and demonstrating added value.

funding model↗

Nanostructure and Composition of Tribo-Boundary Films Formed in Ionic Liquid Lubrication

Since the idea of using ionic liquids (ILs) as lubricants was raised in 2001, many studies have been conducted in this area and results have demonstrated superior lubricating performance for a variety of ionic liquids. It is widely believed that tribochemical reactions occur between the metal surface and the IL during the wear process to form a protective tribo-boundary film on the contact area that reduces friction and wear. However, the study of this critical boundary film has been limited to top surface two-dimensional topography examination and chemical analysis in the literature. A more comprehensive characterization is needed to help understand the film formation process and the lubricating mechanism. This study demonstrated a multi-technique three-dimensional approach to characterize the IL-formed boundary films, including top surface morphology examination, cross section nanostructure characterization, and layered chemical analysis. Characterization was carried out on both ferrous and aluminum surfaces lubricated by an ammonium IL. The focused-ion-beam (FIB) technique enabled TEM/EDS examination on the cross section of the boundary film to provide direct measurement of the film thickness, visualization of the nanostructure, and analysis of composition. In addition, composition-depth profiles were generated using XPS aided by ion-sputtering to reveal the composition change at different levels of the boundary film to investigate the film formation process.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Combining Deep Learning With Physics Based Features in Explosion-Earthquake Discrimination

This paper combines the power of deep-learning with the generalizability of physics-based features, to present an advanced method for seismic discrimination between earthquakes and explosions. The proposed method contains two branches: a deep learning branch operating directly on seismic waveforms or spectrograms, and a second branch operating on physics-based parametric features. These features are high-frequency P/S amplitude ratios and the difference between local magnitude (ML) and coda duration magnitude (MC). The combination achieves better generalization performance when applied to new regions than models that are developed solely with deep learning. Further, we also examined which parts of the waveform data dominate deep learning decisions (i.e., via Grad-CAM). Such visualization provides a window into the black-box nature of the machine-learning models and offers new insight into how the deep learning derived models use data to make decisions.

58 GEOSCIENCES↗

Diagnostics and Impulse Performance of Laser-Ablative Propulsion

Pressure time variations and associated flows induced by pulsed laser ablation were experimentally studied using the Velocity Interferometer System for Any Reflector (VISAR) and framing Schlieren visualization. The combination of either aluminum or polyacetal target and TEA CO{sub 2} laser pulse were examined. The VISAR measurement resolved that the pressure modulated from the laser power variation in the impulse generation processes. Integrated impulse induced by repetative CO{sub 2} laser pulses was measured using a torsion-type impulse balance. The effect of the ambient pressure was significant. The measured impulse characteristics were closely associated with target surface morphology and fluid dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Galaxy morphological classification catalogue of the Dark Energy Survey Year 3 data with convolutional neural networks

ABSTRACT We present in this paper one of the largest galaxy morphological classification catalogues to date, including over 20 million galaxies, using the Dark Energy Survey (DES) Year 3 data based on convolutional neural networks (CNNs). Monochromatic i-band DES images with linear, logarithmic, and gradient scales, matched with debiased visual classifications from the Galaxy Zoo 1 (GZ1) catalogue, are used to train our CNN models. With a training set including bright galaxies (16 ≤ i < 18) at low redshift (z < 0.25), we furthermore investigate the limit of the accuracy of our predictions applied to galaxies at fainter magnitude and at higher redshifts. Our final catalogue covers magnitudes 16 ≤ i < 21, and redshifts z < 1.0, and provides predicted probabilities to two galaxy types – ellipticals and spirals (disc galaxies). Our CNN classifications reveal an accuracy of over 99 per cent for bright galaxies when comparing with the GZ1 classifications (i < 18). For fainter galaxies, the visual classification carried out by three of the co-authors shows that the CNN classifier correctly categorizes discy galaxies with rounder and blurred features, which humans often incorrectly visually classify as ellipticals. As a part of the validation, we carry out one of the largest examinations of non-parametric methods, including ∼100 ,000 galaxies with the same coverage of magnitude and redshift as the training set from our catalogue. We find that the Gini coefficient is the best single parameter discriminator between ellipticals and spirals for this data set.

79 ASTRONOMY AND ASTROPHYSICS↗

XtalCAMP: a comprehensive program for the analysis and visualization of scanning Laue X-ray micro-/nanodiffraction data

XtalCAMP is a software package based on the MATLAB platform, which is suitable for, but not limited to, the analysis and visualization of scanning Laue X-ray micro-/nanodiffraction data. The main objective of the software is to provide complementary functionalities to the Laue indexing software packages used at several synchrotron beamlines. Here, the graphical user interfaces allow the easy analysis of characteristic microstructure features, including real-time intensity mapping for a quick examination of phase, grain and defect distribution, 2D color-coded mapping of microstructural properties from the output of other Laue indexing software, crystal orientation visualization, grain boundary characterization based on orientation/misorientation calculation, principal strain/stress analysis, and strain ellipsoid representation, as well as a series of additional toolkits. As an example, XtalCAMP is applied to the microstructural investigation of a solution-heat-treated Ni-based superalloy manufactured using a laser 3D-printing technique, and a deformed natural quartzite from Val Bregaglia in the Central Alps.

36 MATERIALS SCIENCE↗

Core Characterization of Bakken Shale from the Bedwell 33-52-1-1H Well, Sheridan County, Montana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core of the Bedwell 33-52-1-1H well (API 25-091-21920), a wildcat field in Sheridan County, Montana. The primary impetus of this work is to provide a unique dataset to researchers at universities, national laboratories, geological surveys, and other locations for additional analyses. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/bedwell-33-52-1-1h-well. The equipment and techniques used to characterize the full core were non-destructive, enabling future examinations and analyses to be performed on these cores. However, none of the equipment used was suitable for direct visualization of the pore space in fine-grained structures such as those found in shales; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. A selection of samples (Table 1) were cored, sliced, and powdered for additional characterization analyses. These analyses did involve destructive subsampling of the full core at discrete sections, and the results are presented here in the context of the larger core description. Selected sections of the core were removed from the full core for detailed analyses using the following destructive techniques: bulk inductively coupled plasma-optical emission spectroscopy (ICP-OES), isolation of carbon and sulfur, Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), and higher resolution CT scan with NETL’s micro-CT scanning systems. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

04 OIL SHALES AND TAR SANDS↗

Patient Satisfaction After Femoral Arterial Access Site Closure Using the ExoSeal{sup ®} Vascular Closure Device Compared to Manual Compression: A Prospective Intra-individual Comparative Study

PurposeTo intra-individually compare discomfort levels and patient satisfaction after arterial access closure using the ExoSeal{sup ®} vascular closure device (VCD) and manual compression (MC) in a prospective study design.MethodsPatients undergoing two planned interventions from 07/2013 to 09/2014 could participate in the study. Access closure was performed with an ExoSeal{sup ®}-VCD in one and MC in the other intervention. Patients were clinically and sonographically examined and were given questionnaires 1 day after intervention [groin- and back-pain during bedrest (100-point visual analog scale; 0: no pain); comfortability of bedrest (10-point Likert scale, 1: comfortable), satisfaction with closure (10-point Likert scale, 1: very satisfied)]. Results were analyzed in a cross-over design.Results48 patients (29 male, median age 62.5 (32–88) years) were included. An ExoSeal{sup ®}-VCD was used first in 25 cases. As four of these subsequently refused MC as second intervention, data from 44 patients could be analyzed. All closures were technically successful (successful device deployment) without major complications. Groin- and back-pain after VCD-use/MC was 0 (0–15) vs. 10 (0–80) and 0 (0–75) vs. 25 (0–90), respectively (p < 0.0001). Bedrest after VCD-use was more comfortable than after MC [1 (range 1–7) vs. 6 (2–10); p < 0.0001]. Satisfaction with the closure procedure and with the intervention in general was higher after VCD-use compared to MC [1 (1–3) vs. 5 (2–10) and 1 (1–2) vs. 2 (1–4), respectively; p < 0.0001].ConclusionIntra-individual comparison showed pain levels and discomfort to be significantly lower after ExoSeal{sup ®} use compared to MC. VCD closure was associated with higher satisfaction both with the closure itself and with the intervention in general.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atomic force microscopy of silica nanoparticles and carbon nanohorns in macrophages and red blood cells

The emerging interest in understanding the interactions of nanomaterial with biological systems necessitates imaging tools that capture the spatial and temporal distributions and attributes of the resulting nano-bil amalgam. Studies targeting organ specific response and/ot nanoparticle-specific system toxicity would be profoundly benefited from tools that would allow imaging and tracking of in-vivo or in-vitro processes and particle-fate studies. Recently we demonstrated that mode systhesizing atomic force microscopy (MSAFM) can provide subsurface nanoscale informations on the mechanical properties of materials at the nanoscale. However, the underlying mechanism of this imaging methodology is currently subject to theoretical and experimental investigation. In this paper we present further analysis by investigating tip-sample excitation forces associated with nanomechanical image formation. Images and force curves acquired under various operational frequencies and amplitudes are presented. We examine samples of mouse cells, where buried distributions of single-walled carbon nanohorns and silica nanoparticles are visualized.

Atomic force microscopy↗

Extreme Scale Visual Analytics

Extreme-scale visual analytics (VA) is about applying VA to extreme-scale data. The articles in this special issue examine advances related to extreme-scale VA problems, their analytical and computational challenges, and their real-world applications.

99 GENERAL AND MISCELLANEOUS↗

SU-D-204-05: Quantitative Comparison of a High Resolution Micro-Angiographic Fluoroscopic (MAF) Detector with a Standard Flat Panel Detector (FPD) Using the New Metric of Generalized Measured Relative Object Detectability (GM-ROD)

Purpose: In endovascular image-guided neuro-interventions, visualization of fine detail is paramount. For example, the ability of the interventionist to visualize the stent struts depends heavily on the x-ray imaging detector performance. Methods: A study to examine the relative performance of the high resolution MAF-CMOS (pixel size 75µm, Nyquist frequency 6.6 cycles/mm) and a standard Flat Panel Detector (pixel size 194µm, Nyquist frequency 2.5 cycles/mm) detectors in imaging a neuro stent was done using the Generalized Measured Relative Object Detectability (GM-ROD) metric. Low quantum noise images of a deployed stent were obtained by averaging 95 frames obtained by both detectors without changing other exposure or geometric parameters. The square of the Fourier transform of each image is taken and divided by the generalized normalized noise power spectrum to give an effective measured task-specific signal-to-noise ratio. This expression is then integrated from 0 to each of the detector’s Nyquist frequencies, and the GM-ROD value is determined by taking a ratio of the integrals for the MAF-CMOS to that of the FPD. The lower bound of integration can be varied to emphasize high frequencies in the detector comparisons. Results: The MAF-CMOS detector exhibits vastly superior performance over the FPD when integrating over all frequencies, yielding a GM-ROD value of 63.1. The lower bound of integration was stepped up in increments of 0.5 cycles/mm for higher frequency comparisons. As the lower bound increased, the GM-ROD value was augmented, reflecting the superior performance of the MAF-CMOS in the high frequency regime. Conclusion: GM-ROD is a versatile metric that can provide quantitative detector and task dependent comparisons that can be used as a basis for detector selection. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification and Preservation of Arm Lymphatic System in Axillary Dissection for Breast Cancer to Reduce Arm Lymphedema Events: A Randomized Clinical Trial

Background: Controversy in axillary reverse mapping in axillary lymph node dissection (ALND) possibly results from incomplete recognition of the arm lymphatic system (ALS) and its compromise to oncological safety. The iDEntification and Preservation of ARm lymphaTic system (DEPART) technique facilitates complete identification of ALS; therefore, its use may decrease the occurrence of arm lymphedema. This study aimed to examine the arm lymphedema rate, locoregional recurrence, and feasibility to perform DEPART in ALND. Methods: Patients from February 2013 to October 2017 from two tertiary referral centers were randomly assigned to two groups. In the study group, indocyanine green and methylene blue (MB) were utilized to identify arm sentinel nodes, and 0.1 ml MB was injected into the arm sentinel nodes to reveal the subsequent-echelon nodes and lymphatics. Gross arm lymph nodes were examined by intraoperative partial frozen section and were removed if positive. Arm lymphedema, local recurrence, regional recurrence, and distant metastasis were recorded at different follow-up examinations. Results: Arm sentinel nodes were identified in 573 (83.2%) patients. Subsequent-echelon nodes and lymphatics were visualized in 558 (97.4%) patients. Metastatic arm nodes were identified in 38 (6.8%) patients. The arm lymphedema rate was 3.3% (18/543) in the study group versus 15.3% (99/648) in the control group (p < 0.001) after 37-month median follow-up. Regional recurrence showed no difference between the two groups (1.4% and 1.2%, respectively) (p = 0.392). Conclusions: DEPART can benefit breast cancer patients who undergo ALND, reducing the arm lymphedema rate without adversely affecting the morbidity of regional recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemical clocks: using otolith geochemistry to enhance estimation of age and growth of white hake (Urophycis tenuis)

The white hake (Urophycis tenuis) is a groundfish distributed throughout the Gulf of Maine. Catch advice is based on stock assessments done with age-based population dynamics models; however, otolith aging is challenging because of unclear growth increments. To address this concern, we compared the consistency of aging with counts of visual annuli to that of aging with cycles of elemental concentrations measured by using laser ablation inductively coupled plasma mass spectrometry. We tested the hypothesis that oscillations in both environmental conditions and internal physiology through time influence uptake of elements during otolith mineralization. Concentrations of manganese, in comparison with those of the other investigated trace elements (magnesium, strontium, and barium), had the most promising correlation with visual growth increments (~100% age agreement, ±1 year), offering an additional tool to enhance increment identification. In our examination of 550 otoliths collected during 2007–2021, we found that white hake lived a maximum of 10.3 years and exhibited sexual dimorphism in maximum length and age. By using generated von Bertalanffy growth functions, L(t)=110(1–e–0.113(t+0.45)) for males and L(t)=140(1–e–0.113(t–0.30)) for females (where L(t) is length at time t), size and age at maturity were calculated for males (37.4 cm in total length (TL), 3.3 years) and females (47.4 cm TL, 4.2 years). These results demonstrate that otolith geochemistry can be used to improve the accuracy and precision of the estimation of fish age and maturity, even for challenging species.

59 BASIC BIOLOGICAL SCIENCES↗

Examining phase separation and crystallization in glasses with X-ray nano-computed tomography

X-ray nano-computed tomography (nano-CT) is a powerful technique to characterize and visualize 3 dimensional (3D) phenomena in complex glasses at the nanoscale. This technique can offer a unique opportunity to explore the intricate morphology of multicomponent glass and glass-ceramic samples, due to its low X-ray energy and high spatial resolution (down to 50 nm). In the current demonstration paper, nano-CT provided insight into crystallization and phase separation, as well as a variety of other phenomena, including corrosion, fracture, and porosity. At scales ranging from 100 to 20 μm, the microstructures of phase separation in borosilicate, complex silicate, and chalcogenide glass compositions were examined. In addition, crystallites present in simulant nuclear waste glasses, volcanic glasses, and other related samples were explored. Nano-CT analysis can add to the understanding of (1) the formation processes, (2) distributions, interactions, and compositions of phases, and (3) the mechanisms, structures, and growth of crystallization and phase separation. Nano-CT offers wide potential in the field of glass science, especially when (1) common characterization methods are insufficient, (2) simple sample preparation is required, (3) 3D rendering is needed, or (4) compelling images of small, complex features are desired.

36 MATERIALS SCIENCE↗

Verification of Compartmental Epidemiological Models using Metamorphic Testing, Model Checking and Visual Analytics

Compartmental models in epidemiology are widely used as a means to model disease spread mechanisms and understand how one can best control the disease in case an outbreak of a widespread epidemic occurs. However, a significant challenge within the community is in the development of approaches that can be used to rigorously verify and validate these models. In this paper, we present an approach to rigorously examine and verify the behavioral properties of compartmen- tal epidemiological models under several common modeling scenarios including birth/death rates and multi-host/pathogen species. Using metamorphic testing, a novel visualization tool and model checking, we build a workflow that provides insights into the functionality of compartmental epidemiological models. Our initial results indicate that metamorphic testing can be used to verify the implementation of these models and provide insights into special conditions where these mathematical models may fail. The visualization front-end allows the end-user to scan through a variety of parameters commonly used in these models to elucidate the conditions under which an epidemic can occur. Further, specifying these models using a process algebra allows one to automatically construct behavioral properties that can be rigorously verified using model checking. Taken together, our approach allows for detecting implementation errors as well as handling conditions under which compartmental epidemiological models may fail to provide insights into disease spread dynamics.

Ramanathan, Arvind↗

View-Dependent Streamline Deformation and Exploration

Occlusion presents a major challenge in visualizing 3D flow and tensor fields using streamlines. Displaying too many streamlines creates a dense visualization filled with occluded structures, but displaying too few streams risks losing important features. We propose a new streamline exploration approach by visually manipulating the cluttered streamlines by pulling visible layers apart and revealing the hidden structures underneath. Here this paper presents a customized view-dependent deformation algorithm and an interactive visualization tool to minimize visual cluttering for visualizing 3D vector and tensor fields. The algorithm is able to maintain the overall integrity of the fields and expose previously hidden structures. Our system supports both mouse and direct-touch interactions to manipulate the viewing perspectives and visualize the streamlines in depth. By using a lens metaphor of different shapes to select the transition zone of the targeted area interactively, the users can move their focus and examine the vector or tensor field freely.

97 MATHEMATICS AND COMPUTING↗

Shewanella knowledgebase: integration of the experimental data and computational predictions suggests a biological role for transcription of intergenic regions

Shewanellae are facultative gamma-proteobacteria whose remarkable respiratory versatility has resulted in interest in their utility for bioremediation of heavy metals and radionuclides and for energy generation in microbial fuel cells. Extensive experimental efforts over the last several years and the availability of 21 sequenced Shewanella genomes made it possible to collect and integrate a wealth of information on the genus into one public resource providing new avenues for making biological discoveries and for developing a system level understanding of the cellular processes. The Shewanella knowledgebase was established in 2005 to provide a framework for integrated genome-based studies on Shewanella ecophysiology. The present version of the knowledgebase provides access to a diverse set of experimental and genomic data along with tools for curation of genome annotations and visualization and integration of genomic data with experimental data. As a demonstration of the utility of this resource, we examined a single microarray data set from Shewanella oneidensis MR-1 for new insights into regulatory processes. The integrated analysis of the data predicted a new type of bacterial transcriptional regulation involving co-transcription of the intergenic region with the downstream gene and suggested a biological role for co-transcription that likely prevents the binding of a regulator of the upstream gene to the regulator binding site located in the intergenic region. Database URL: http://shewanella-knowledgebase.org:8080/Shewanella/ or http://spruce.ornl.gov:8080/Shewanella/

30 DIRECT ENERGY CONVERSION↗

Results and Analysis of the Infrastructure Request for Information (DE-SOL-0008318)

The Department of Energy (DOE) Office of Nuclear Energy (NE) released a request for information (RFI) (DE-SOL-0008318) for “University, National Laboratory, Industry and International Input on Potential Office of Nuclear Energy Infrastructure Investments” on April 13, 2015. DOE-NE solicited information on five specific types of capabilities as well as any others suggested by the community. The RFI proposal period closed on June 19, 2015. From the 26 responses, 34 individual proposals were extracted. Eighteen were associated with a DOE national laboratory, including Argonne National Laboratory (ANL), Brookhaven National Laboratory (BNL), Idaho National Laboratory (INL), Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratory (SNL). Oak Ridge National Laboratory (ORNL) was referenced in a proposal as a proposed capability location, although the proposal did not originate with ORNL. Five US universities submitted proposals (Massachusetts Institute of Technology, Pennsylvania State University, Rensselaer Polytechnic Institute, University of Houston and the University of Michigan). Three industrial/commercial institutions submitted proposals (AREVA NP, Babcock and Wilcox (B&W) and the Electric Power Research Institute (EPRI)). Eight major themes emerged from the submissions as areas needing additional capability or support for existing capabilities. Two submissions supported multiple areas. The major themes are: Advanced Manufacturing (AM), High Performance Computing (HPC), Ion Irradiation with X-Ray Diagnostics (IIX), Ion Irradiation with TEM Visualization (IIT), Radiochemistry Laboratories (RCL), Test Reactors, Neutron Sources and Critical Facilities (RX) , Sample Preparation and Post-Irradiation Examination (PIE) and Thermal-Hydraulics Test Facilities (THF).

99 GENERAL AND MISCELLANEOUS↗