Search NASA⌕ Search

SEARCH · Search NASA

Results for “WATER VAPOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Remote Sensing of Water Vapor and Thin Cirrus Clouds using MODIS Near-IR Channels

The Moderate Resolution Imaging Spectroradiometer (MODIS), a major facility instrument on board the Terra Spacecraft, was successfully launched into space in December of 1999. MODIS has several near-IR channels within and around the 0.94 micrometer water vapor bands for remote sensing of integrated atmospheric water vapor over land and above clouds. MODIS also has a special near-IR channel centered at 1.375-micron with a width of 30 nm for remote sensing of cirrus clouds. In this paper, we describe briefly the physical principles on remote sensing of water vapor and cirrus clouds using these channels. We also present sample water vapor images and cirrus cloud images obtained from MODIS data.

Gao, Bo-Cai↗

The Dependence of Mean Climate State on Shortwave Absorption by Water Vapor

Abstract State-of-the-art climate models exhibit significant spread in the climatological value of atmospheric shortwave absorption (SWA). This study investigates both the possible causes and climatic impacts of this SWA intermodel spread. The intermodel spread of global-mean SWA largely originates from the intermodel difference in water vapor shortwave absorptivity. Hence, we alter the water vapor shortwave absorptivity in the Community Earth System Model, version 1, with the Community Atmosphere Model, version 4 (CESM1-CAM4). Increasing the water vapor shortwave absorptivity leads to a reduction in global-mean precipitation and a La Niña–like cooling over the tropical Pacific. The global-mean atmospheric energy budget suggests that the precipitation is suppressed as a way to compensate for the increased SWA. The precipitation reduction is driven by the weakened surface winds, stabilized planetary boundary layer, and surface cooling. The La Niña–like cooling over the tropical Pacific is attributed to the zonal asymmetry of climatological evaporative damping efficiency and the low cloud enhancement over the eastern basin. Complementary fixed SSTs simulations suggest that the latter is more fundamental and that it primarily arises from atmospheric processes. Consistent with our experiments, the CMIP5/6 models with a higher global-mean SWA tend to produce tropical Pacific toward a more La Niña–like mean state, highlighting the possible role of water vapor shortwave absorptivity for shaping the mean-state climate patterns.

Kim, Hanjun↗

Profiling atmospheric water vapor by microwave radiometry

High-altitude microwave radiometric observations at frequencies near 92 and 183.3 GHz were used to study the potential of retrieving atmospheric water vapor profiles over both land and water. An algorithm based on an extended kalman-Bucy filter was implemented and applied for the water vapor retrieval. The results show great promise in atmospheric water vapor profiling by microwave radiometry heretofore not attainable at lower frequencies.

Wang, J. R.↗

The seasonal variation of water vapor and ozone in the upper mesosphere - Implications for vertical transport and ozone photochemistry

This paper reviews the data base supplied by ground-based microwave measurements of water vapor in the mesosphere obtained in three separate experiments over an eight-year period. These measurements indicate that the seasonal variation of water vapor in the mesosphere is dominated by an annual component with low values in winter and high values in summer, suggesting that the seasonal variation of water vapor in the mesosphere (below 80 km) is controlled by advective rather than diffusive processes. Both the seasonal variation and the absolute magnitude of the water vapor mixing ratios obtained in microwave measurements were corroborated by measurements obtained in the Spacelab GRILLE and ATMOS experiments, and were found to be consistent with several recent mesospheric dynamics studies.

Bevilacqua, Richard M.↗

Water Vapor Isotopic Composition from the ARM ENA Site, March 2018-March 2019

Humidity and water vapor δD and δ18O measurements were collected for a period of one year (March 1, 2018 to February 28, 2019) at the Department of Energy Atmospheric Radiation Measurement facility on Graciosa Island, Azores. Continuous in-situ measurements were collected in the boundary layer using a Los Gatos Research Triple Water Vapor Isotope Analyzer. Stable Isotope measurements were corrected for humidity-induced bias, calibrated to international standards, accounted for time-drift, and are presented as 3-hour averages.

54 ENVIRONMENTAL SCIENCES↗

The Apollo lunar surface water vapor event revisited

On March 7, 1971, the first sunrise following the Apollo 14 mission, the Suprathermal Ion Detector Experiment (SIDE) deployed at the Apollo 14 site reported an intense flux of ions whose mass per charge was consistent with water vapor. The amount of water is examined, and the various acceleration processes, responsible for accelerating ions into the SIDE, are discussed. It is concluded that during most of the event the observed water vapor ions were accelerated by the negative lunar surface electric potential and, secondly, that this event was probably the result of mission associated water vapor, either from the LM ascent and descent stage rockets or from residual water in the descent stage tanks.

Freeman, J. W., Jr.↗

Interference of oxygen, carbon dioxide, and water vapor on the analysis for oxides of nitrogen by chemiluminescence

The interference of small concentrations (less than 4 percent by volume) of oxygen, carbon dioxide, and water vapor on the analysis for oxides of nitrogen by chemiluminescence was measured. The sample gas consisted primarily of nitrogen, with less than 100 parts per million concentration of nitric oxide, and with small concentrations of oxygen, carbon dioxide, and water vapor added. Results obtained under these conditions indicate that although oxygen does not measurably affect the analysis for nitric oxide, the presence of carbon dioxide and water vapor causes the indicated nitric oxide concentration to be too low. An interference factor - defined as the percentage change in indicated nitric oxide concentration (relative to the true nitric oxide concentration) divided by the percent interfering gas present - was determined for carbon dioxide to be -0.60 + or - 0.04 and for water vapor to be -2.1 + or - 0.3.

Maahs, H. G.↗

Airborne remote sensing of tropospheric water vapor using a near infrared DIAL system

Summarized here are the results of airborne water vapor measurements in the lower middle and upper troposphere using the Differential Absorption Lidar (DIAL) technique in the near infrared. The measurements were performed in July 1990 in Southern Bavaria between Allersberg and Straubing from 20 to 23 UTC taking advantage of night time conditions. The tropospheric H2O profiles were range investigated both horizontally and vertically. With the DIAL system that was used, water vapor measurements in the upper troposphere have been carried out for the first time. To calibrate the H2O-retrievals, effective absorption cross sections of selected H2O lines in terms of altitude around 724 nm were calculated using line parameter data from the literature (B. E. Grossmann et al). The frequency of the on-line measurements was adjusted by the spectra of a Polyacenic Semiconductor (PAS) cell filled with H2O. We found that the calibration error ranged between 0.005 and 0.015 cm(exp -1). The systematic errors of the H2O as a function of altitude were estimated below 7 km and 12 percent accuracy in the upper troposphere. The vertical H2O profile agrees well with in situ measurements in the investigated range between the top of the planetary boundary layer (PBL) up to near the tropopause. Horizontal and vertical H2O profiles are calculated by means of averaging single lidar returns. Typical horizontal resolutions range from 4 km in the lower to 11 km in the upper troposphere with vertical resolutions varying from 0.3 km up to 1 km, respectively, in order to satisfy a 5 - 10 percent accuracy in the statistical error. The measurement sensibility of the water vapor mixing ration in the upper troposphere is 0.01 g/kg.

Ehret, G.↗

In situ measurement of water vapor in the stratosphere with a cryogenically cooled Lyman-alpha hygrometer

In situ measurements of water vapor in the stratosphere with a new instrument are reported. The instrument has been designed to observe daytime water vapor from a multiinstrument balloon gondola that simultaneously measures free radicals such as OH, HO2, and O3 in the stratosphere up to 40 km. Lyman-alpha photofragment fluorescence is used to measure water molecules in a flowing sample of ambient air. A brief description of the instrument is given, followed by the results of the first four balloon flights. The measured mixing ratio for this flight varies from 3.0-5.5 ppmv over the altitude range of 17-34 km. Adjustments in the cooling protocol for the flights of July 6, 1988, July 28, and August 25, 1989, result in a much higher signal-to-noise ratio. Profiles from these three flights are similar to, but somewhat higher, than the 1987 profile. Implications of measurements are discussed, as are the issues of short- and long-term variability of stratospheric water vapor.

Schwab, J. J.↗

Water Vapor in Titan's Stratosphere from Cassini/CIRS Far-infrared Spectra

Since the first detection of water vapor in Titan's stratosphere by disk-average observations from the Infrared Space Observatory (Coustenis et al. 1998) we report here the successful detection of stratospheric water vapor using the Cassini Composite Infrared Spectrometer (CIRS, Flasar et al. 2004). CIRS senses water emissions in the far infrared spectral region near 50 microns, which we have modeled using two independent radiative transfer codes (NEMESIS, Irwin et al 2008 and ART, Coustenis et al. 2007, 2010). From the analysis of nadir spectra we have derived a mixing ratio of (0.14 0.05) ppb at an altitude of 97 kilometers, which corresponds to an integrated (from 0 to 600 kilometers) surface normalized column abundance of (3.7 plus or minus 1.3) x 10(exp 14) molecules per square centimeter. In the latitude range 80 S to 30 N we see no evidence for latitudinal variations in these abundances within the error bars. Using limb observations, we obtained mixing ratios of (0.13 plus or minus 0.04) ppb at an altitude of 115 kilometers and (0.45 plus or minus 0.15) ppb at an altitude of 230 kilometers, confirming that the water abundance has a positive vertical gradient as predicted by photochemical models (e.g. Lara et al. 1996, Wilson and Atreya 2004, Horst et al. 2008); retrieved scaling factors (from approximately 0.1 to approximately 0.6) to the water profile suggested by these models show that water vapor is present in Titan stratosphere with less abundance than predicted.

Cottini, V.↗

Measurements of lower stratospheric/upper tropospheric water vapor by the SAGE II instrument

Preliminary, unvalidated data are discussed from early measurements of water vapor profiles in the upper troposphere/lower stratosphere by means of SAGE II satellite sensors. Zonal means for April 1985 are discussed and compared with previous, separate data sets for water vapor profiles for the 100 mbar and 300 mbar levels determined from space-based IR and rawinsonde data. Techniques employed to correct for noisy measurements due to the presence of clouds in the SAGE II scenes are described, noting the slant path transmission methods applied to generate the water vapor profiles.

Larsen, J. C.↗

Multi-model analysis of the impact of water vapor on the radiative forcing of volcanic aerosols after the 2022 Hunga Eruption

On 15 January 2022, the Hunga volcano eruption released unprecedented amounts of water vapor into the atmosphere alongside a modest amount of SO 2 . In this work we analyse results from multiple Earth system models as part of the Hunga Tonga-Hunga Ha'apai Volcano Impact Model Observation Comparison Project. Our results show a good model agreement over the climatic outcomes of the eruption, overall indicating a significant negative radiative forcing from the Hunga eruption. The multi-model mean of global instantaneous radiative forcing averaged over 2022–2023 is estimated at −0.19 ± 0.06 W m −2 at the top-of-atmosphere (TOA), and −0.16 ± 0.06 W m −2 at the surface. Simulations with free-running meteorology and climatological sea surface temperatures and sea ice yield a global mean TOA forcing of −0.14 ± 0.10 W m −2 across two models for the first 2 years, decreasing to −0.09 ± 0.10 W m −2 on average between 2022 and 2027. However, these global values may be underestimated by about 50 %, considering that recent SO 2 injection retrievals suggest nearly twice the amount than the 0.5 Tg-SO 2 used in the protocol. We also find that the contribution from added stratospheric water vapor is minimal and that the injected SO 2 and the resulting formation of stratospheric sulfate dominate the radiative forcing. However, water vapor played a key role in the initial aerosol growth, leading to a stronger negative radiative forcing during the first 6 months after the eruption compared to simulations without water vapor co-injection.

Geosciences↗

GPS meteorology - Remote sensing of atmospheric water vapor using the Global Positioning System

We present a new approach to remote sensing of water vapor based on the Global Positioning System (GPS). Geodesists and geophysicists have devised methods for estimating the extent to which signals propagating from GPS satellites to ground-based GPS receivers are delayed by atmospheric water vapor. This delay is parameterized in terms of a time-varying zenith wet delay (ZWD) which is retrieved by stochastic filtering of the GPS data. Given surface temperature and pressure readings at the GPS receiver, the retrieved ZWD can be transformed with very little additional uncertainty into an estimate of the integrated water vapor (IWV) overlying that receiver. Networks of continuously operating GPS receivers are being constructed by geodesists, geophysicists, and government and military agencies, in order to implement a wide range of positioning capabilities. These emerging GPS networks offer the possibility of observing the horizontal distribution of IWV or, equivalently, precipitate water with unprecedented coverage and a temporal resolution of the order of 10 min. These measurements could be utilized in operational weather forecasting and in fundamental research into atmospheric storm systems, the hydrologic cycle, atmospheric chemistry, and global climate change.

Bevis, Michael↗

The Relative Importance of Random Error and Observation Frequency in Detecting Trends in Upper Tropospheric Water Vapor

Recent published work assessed the amount of time to detect trends in atmospheric water vapor over the coming century. We address the same question and conclude that under the most optimistic scenarios and assuming perfect data (i.e., observations with no measurement uncertainty) the time to detect trends will be at least 12 years at approximately 200 hPa in the upper troposphere. Our times to detect trends are therefore shorter than those recently reported and this difference is affected by data sources used, method of processing the data, geographic location and pressure level in the atmosphere where the analyses were performed. We then consider the question of how instrumental uncertainty plays into the assessment of time to detect trends. We conclude that due to the high natural variability in atmospheric water vapor, the amount of time to detect trends in the upper troposphere is relatively insensitive to instrumental random uncertainty and that it is much more important to increase the frequency of measurement than to decrease the random error in the measurement. This is put in the context of international networks such as the Global Climate Observing System (GCOS) Reference Upper-Air Network (GRUAN) and the Network for the Detection of Atmospheric Composition Change (NDACC) that are tasked with developing time series of climate quality water vapor data.

Whiteman, David N.↗

Remote sensing of water vapor in the near IR from EOS/MODIS

Consideration is given to the selection of spectral channels in the near-infrared IR which are to be employed for the derivation of total column water vapor using the MODIS instrument on the NASA's Earth Observing System. Data obtained show that the three near-IR water vapor channels on the MODIS instrument enable remote sensing of the total column water vapor with an absolute accuracy of +/- 13 percent. An absolute accuracy of +/-7 percent can be obtained if additional MODIS channels are used to decrease the effect of uncertainty in the spectral reflectance of the surface, subpixel clouds, haze, and temperature profile on the derived water vapor.

Kaufman, Yoram J.↗

Comparison of Columnar Water Vapor Measurements During The Fall 1997 ARM Intensive Observation Period: Optical Methods

In the fall of 1997 the Atmospheric Radiation Measurement (ARM program conducted an intensive Observation Period (IOP) to study water vapor at its Southern Great Plains (SGP) site. Among the large number of instruments, four sun-tracking radiometers were present to measure the columnar water vapor (CWV). All four solar radiometers retrieve CWV by measuring solar transmittance in the 0.94-micrometer water vapor absorption band. As one of the steps in the CWV retrievals the aerosol component is subtracted from the total transmittance, in the 0.94-micrometer band. The aerosol optical depth comparisons among the same four radiometers are presented elsewhere. We have used three different methods to retrieve CWV. Without attempting to standardize on the same radiative transfer model and its underlying water vapor spectroscopy we found the CWV to agree within 0.13 cm (rms) for CWV values ranging from 1 to 5 cm. Preliminary results obtained when using the same updated radiative transfer model with updated spectroscopy for all instruments will also be shown. Comparisons to the microwave radiometer results will be included in the comparisons.

Schmid, Beat↗

Characterization of AIRS temperature and water vapor measurement capability using correlative observations

In this presentation we address several fundamental issues in the measurement of temperature and water vapor by AIRS: accuracy, precision, vertical resolution and biases as a function of cloud amount. We use two correlative data sources. First we compare AIRS total water vapor with that from the Advanced microwave Sounding Radiometer for EOS (AMSR-E) instrument, also onboard the Aqua spacecraft. AMSRE uses a mature methodology with a heritage including the operational Special Sensor Microwave Imager (SSM/I) instruments. AIRS and AMSR-E observations are collocated and simultaneous, providing a very large data set for comparison: about 200,000 over-ocean matches daily. We show small cloud-dependent biases between AIRS and AMSR-E total water vapor for several oceanic regions. Our second correlative data source is several hundred dedicated radiosondes launched during AIRS overpasses.

meteorology↗

Raman Lidar Water Vapor Measurements at the DOE SGP CART Site

The NASA/GSFC Scanning Raman Lidar (SRL) was deployed to the Department of Energy's (DOE) Cloud and Radiation Testbed site in northern Oklahoma September - December, 2000 for two DOE sponsored field campaigns: 1) the Water Vapor Intensive Operations Experiment 2000 and 2) the Atmospheric Radiations Measurement First International Satellite Cloud Climatology Experiment Experiment (AFWEX). WvIOP2000 focussed on water vapor measurements in the lower troposphere while AFWEX focussed on upper tropospheric water vapor. For the first time ever, four water vapor lidars were operated simultaneously: one airborne and three ground-based systems. Intercomparisons of these measurements and others will be presented at the meeting.

Whiteman, David N.↗