Search NASA⌕ Search

SEARCH · Search NASA

Results for “acquisition function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

MDSplus Yesterday, Today and Tomorrow

MDSplus is a data acquisition and analysis system used worldwide predominantly in the fusion research community. Development began 31 years ago by a collaboration of software developers who were charged with providing a data acquisition system for three new fusion experiments under construction: CMOD at MIT, ZTH at LANL and RFX at Padova, Italy. The design of MDSplus combined the functionality of MDS (MIT/Model Data System developed at MIT for the Alcator and Tara fusion experiments) with new features suggested by the developers from the other laboratories. The development of MDSplus used a RAD (rapid application development) approach before RAD became a mainstream methodology. MDSplus was implemented and ready for the initial operation of CMOD in 1991. Since that time, many other fusion facilities started using MDSplus for data acquisition and/or for exporting their data to other sites. Today MDSplus is still used around the world for fusion energy research, space exploration and other fields of science and technology. Work on MDSplus continues to enhance its capabilities, support more platforms, and improve its reliability. It is anticipated that MDSplus will continue to provide valuable tools for the fusion energy research community. This paper describes some of the history of the MDSplus software, the work that is currently underway, and the plans to enable MDSplus to continue to be available and supported long into the future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast X-ray Nanotomography with Sub-10 nm Resolution as a Powerful Imaging Tool for Nanotechnology and Energy Storage Applications

In the last decade, transmission X-ray microscopes (TXMs) have come into operation in most of the synchrotrons worldwide. They have proven to be outstanding tools for non-invasive ex and in situ 3D characterization of materials at the nanoscale across varying range of scientific applications. However, their spatial resolution has not improved in many years, while newly developed functional materials and microdevices with enhanced performances exhibit nanostructures always finer. Here, optomechanical breakthroughs leading to fast 3D tomographic acquisitions (85 min) with sub-10 nm spatial resolution, narrowing the gap between X-ray and electron microscopy, are reported. These new achievements are first validated with 3D characterizations of nanolithography objects corresponding to ultrahigh-aspect-ratio hard X-ray zone plates. Then, this powerful technique is used to investigate the morphology and conformality of nanometer-thick film electrodes synthesized by atomic layer deposition and magnetron sputtering deposition methods on 3D silicon scaffolds for electrochemical energy storage applications.

36 MATERIALS SCIENCE↗

Spectroscopic and computational investigations of organometallic complexation of group 12 transition metals by methanobactins from Methylocystis sp. SB2

Methanotrophic bacteria catalyze the aerobic oxidation of methane to methanol using Cu-containing enzymes, thereby exerting a modulating influence on the global methane cycle. To facilitate the acquisition of Cu ions, some methanotrophic bacteria secrete small modified peptides known as “methanobactins,” which strongly bind Cu and function as an extracellular Cu recruitment relay, analogous to siderophores and Fe. In addition to Cu, methanobactins form complexes with other late transition metals, including the Group 12 transition metals Zn, Cd, and Hg, although the interplay among solution-phase configurations, metal interactions, and the spectroscopic signatures of methanobactin-metal complexes remains ambiguous. In this study, the complexation of Zn, Cd, and Hg by methanobactin from Methylocystis sp. strain SB2 was studied using a combination of absorbance, fluorescence, extended x-ray absorption fine structure (EXAFS) spectroscopy, and time-dependent density functional theory (TD-DFT) calculations. We report changes in sample absorbance and fluorescence spectral dynamics, which occur on a wide range of experimental timescales and characterize a clear stoichiometric complexation dependence. Mercury L3-edge EXAFS and TD-DFT calculations suggest a linear model for Hg--S coordination, and TD-DFT suggests a tetrahedral model for Zn 2+ and Cd 2+ . We observed an enhancement in the fluorescence of methanobactin upon interaction with transition metals and propose a mechanism of complexation-hindered isomerization drawing inspiration from the wild-type Green Fluorescent Protein active site. Collectively, our results represent the first combined computational and experimental spectroscopy study of methanobactins and shed new light on molecular interactions and dynamics that characterize complexes of methanobactins with Group 12 transition metals.

59 BASIC BIOLOGICAL SCIENCES↗

A high-density, high-channel count, multiplexed μECoG array for auditory-cortex recordings

Our understanding of the large-scale population dynamics of neural activity is limited, in part, by our inability to record simultaneously from large regions of the cortex. Here, we validated the use of a large-scale active microelectrode array that simultaneously records 196 multiplexed micro-electrocortigraphical (μECoG) signals from the cortical surface at a very high density (1,600 electrodes/cm 2 ). We compared μECoG measurements in auditory cortex using a custom “active” electrode array to those recorded using a conventional “passive” μECoG array. Both of these array responses were also compared with data recorded via intrinsic optical imaging, which is a standard methodology for recording sound-evoked cortical activity. Custom active μECoG arrays generated more veridical representations of the tonotopic organization of the auditory cortex than current commercially available passive μECoG arrays. Furthermore, the cortical representation could be measured efficiently with the active arrays, requiring as little as 13.5 s of neural data acquisition. Next, we generated spectrotemporal receptive fields from the recorded neural activity on the active μECoG array and identified functional organizational principles comparable to those observed using intrinsic metabolic imaging and single-neuron recordings. Furthermore, this new electrode array technology has the potential for large-scale, temporally precise monitoring and mapping of the cortex, without the use of invasive penetrating electrodes.

60 APPLIED LIFE SCIENCES↗

Self-referenced single-shot THz detection

We demonstrate a self-referencing method to reduce noise in a single-shot terahertz detection scheme. By splitting a single terahertz pulse and using a reflective echelon, both the signal and reference terahertz time-domain waveforms were measured using one laser pulse. Simultaneous acquisition of these waveforms significantly reduces noise originating from shot-to-shot fluctuations. Here, we show that correlation function based referencing, which is not limited to polarization dependent measurements, can achieve a noise floor that is comparable to state-of-the-art polarization-gated balanced detection. Lastly, we extract the DC conductivity of a 30 nm free-standing gold film using a single THz pulse. The measured value of σ 0 = 1.3 ± 0.4 × 10 7 S m -1 is in good agreement with the value measured by four-point probe, indicating the viability of this method for measuring dynamical changes and small signals.

36 MATERIALS SCIENCE↗

First-Principles-Based Computational Study on Nucleation and Growth Mechanisms of U on Mo(110) Surface Solvated in an Eutectic LiCl-KCl Molten Salt

In nuclear engineering and industry electrochemical methods have been intensively employed in pyro-processing technology to recycle used nuclear fuels for substantial alleviation of the concern with the safe treatment of high-level radioactive nuclear wastes. Pyro-processing is based on sequential electrochemical reactions at high temperature (typically above 700 K at ambient pressure) to enhance the efficiency for decoupling nuclear fuels from unfavorable fission fragments. Using a molten salt in electrorefining process, at which actinides can be selectively deposited in solid cathode from ionic states, gives several advantages over an aqueous solution: higher thermal conductivity (it is liquid phase at high temperature, molten salt plays a role as medium at high temperature over 773 K in electrochemical reaction, lower kinetic barrier in ionic diffusion mobility and better stability against undesired side reactions with radioactive materials. Therefore, the volume of high-level nuclear wastes to be, otherwise, disposed into secured sites is dramatically reduced. Most of all it conforms to nuclear non-proliferation treaty. Electrochemical reactions in a molten salt medium are, however, much more complicated than in aqueous solution rendering the accurate understanding of thermodynamic and kinetic properties formidably challenging. It is represented by extensive researches in experiments and computations to identify underlying mechanisms on how U and other fission fragments behave in the electrorefining system. Regardless of the researches there is a general agreement that the initial stage of the nucleation and growth process of the U deposit is critical for determining the properties of final product and the electrorefining efficiency. In spite of the focused studies it still remains unclear. Theoretical and computational researches have been often carried out with various empirical parameter for interatomic potential energy, which are unknown variables until numerical fits to experimental measurements or just assumption is made. Thus, empirical simulations sometimes predicted outcomes are inconsistent depending on materials of interest with experimental measurements. This may be largely because the accuracy of an empirical interatomic potential energy models critically depends on the input parameters and thus, can be limited in transferability of the results. Furthermore, it may be devoid of fundamental physics or chemistry. This situation requires special caution when an electrorefining system is studied to recycle spent nuclear fuels because of the extreme difficulty in reliable acquisition of thermodynamic and kinetic data from direct experimental measurements. In this presentation, we extensively utilized first principles density functional theory (DFT) calculations and ab-initio molecular dynamic (AIMD) simulations to figure out underlying mechanisms of the initial stage of nucleation and growth behaviors of U on Mo(110) surface in a eutectic LiCl-KCl molten salt at T = 773 K. To rigorously investigate the effect of the molten salt electrolyte we compared the results with those calculated under vacuum condition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Data Acquisition System for Kinetic Inductance Detectors: Wide Dynamic Range and High Sampling Rate for Astronomical Observation

Microwave kinetic inductance detectors have a variety of potential applications in astronomical observations. We built a data acquisition system for kinetic inductance detectors combining a dedicated analog board and a commercially available digital board to meet the requirements of astronomical measurements, such as observation of the cosmic microwave background. This paper reports the status of the development of the data acquisition system. We have already achieved simultaneous readout through 120 channels using a direct down-conversion method to decode the signal. A variety of software has been developed and tested using the functionalities of the system and actual detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECON-T and ECON-D: Endcap Concentrator ASICs for the CMS HGCAL

With over 6 million channels, the High Granularity Calorimeter (HGCAL) for the CMS HL-LHC Upgrade presents a unique data challenge. The ECON ASICs provide critical on-detector data reduction for the 40 MHz trigger path (ECON-T) and 750 kHz data acquisition path (ECON-D) of the HGCAL. The ASICs, fabricated in 65 nm CMOS, are rad-tolerant (600 Mrad) with low power consumption (<2.5 mW/channel). This presentation is the first comprehensive description of the ECON designs, first functionality and radiation tests for the ECON-T ASIC, and first results from the full production of 75k ECON-D and ECON-T ASICs.

Bergamin, G. [CERN] (ORCID:0000000285758704)↗

Electronic system for data acquisition to study radiation effects on operating MOSFET transistors

In this work we present the development of an acquisition system for characterizing transistors under X-ray radiation. The system is able to carry out the acquisition and to storage characteristic transistor curves. To test the acquisition system we have submitted polarized P channel MOS transistors under continuous 10-keV X-ray doses up to 1500 krad. The characterization system can operate in the saturation region or in the linear region in order to observe the behavior of the currents or voltages involved during the irradiation process. Initial tests consisted of placing the device under test (DUT) in front of the X-ray beam direction, while its drain current was constantly monitored through the prototype generated in this work, the data are stored continuously and system behavior was monitored during the test. In order to observe the behavior of the DUT during the radiation tests, we used an acquisition system that consists of an ultra-low consumption16-bit Texas Instruments MSP430 microprocessor. Preliminary results indicate linear behavior of the voltage as a function of the exposure time and fast recovery. These features may be favorable to use this device as a radiation dosimeter to monitor low rate X-ray.

36 MATERIALS SCIENCE↗

SHMTools: a general-purpose software tool for SHM applications

This paper describes a new software package for various structural health monitoring (SHM) applications. The software is a set of standardized MATLAB routines covering three main stages of SHM: data acquisition, feature extraction, and feature classification for damage identification. A subset of the software in SHMTools is embeddable, which consists of Matlab functions that can be cross-compiled into generic 'C' programs to be run on a target hardware. The software is also designed to accommodate multiple sensing modalities, including piezoelectric active-sensing, which has been widely used in SHM practice. The software package, including standardized datasets, are publicly available for use by the SHM community. The details of this embeddable software will be discussed, along with several example processes that can be used for guidelines for future use of the software.

42 ENGINEERING↗

Restoration and Modification of Magnetosome Biosynthesis by Internal Gene Acquisition in a Magnetotactic Bacterium

We report that the Integration of a large-sized DNA fragment into a chromosome is an important strategy for characterization of cellular functions in microorganisms. Magnetotactic bacteria synthesize intracellular organelles comprising membrane-bound single crystalline magnetite, also referred to as magnetosomes. Magnetosomes have gained interest in both scientific and engineering sectors as they can be utilized as a material for biomedical and nanotechnological applications. Although genetic engineering of magnetosome biosynthesis mechanism has been investigated, the current method requires cumbersome gene preparation processes. Here, the chromosomal integration of a plasmid containing ≈27 magnetosome genes (≈26 kbp region) in a non-magnetic mutant of Magnetospirillum magneticum AMB-1 using a broad-host-range plasmid is shown. The genome sequencing of gene-complemented strains reveals the chromosomal integration of the plasmid with magnetosome genes at a specific site, most likely by catalysis of an endogenous transposase. Magnetosome production is successfully enhanced by integrating a variation of magnetosome gene operons in the chromosome. This chromosomal integration mechanism will allow the design of functional magnetosomes de novo and M. magneticum AMB-1 may be used as a chassis for the designed magnetosome production.

59 BASIC BIOLOGICAL SCIENCES↗

WE-E-12A-01: Medical Physics 1.0 to 2.0: MRI, Displays, Informatics

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidence-based medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. MRI 2.0: This presentation will look into the future of clinical MR imaging and what the clinical medical physicist will need to be doing as the technology of MR imaging evolves. Many of the measurement techniques used today will need to be expanded to address the advent of higher field imaging systems and dedicated imagers for specialty applications. Included will be the need to address quality assurance and testing metrics for multi-channel MR imagers and hybrid devices such as MR/PET systems. New pulse sequences and acquisition methods, increasing use of MR spectroscopy, and real-time guidance procedures will place the burden on the medical physicist to define and use new tools to properly evaluate these systems, but the clinical applications must be understood so that these tools are use correctly. Finally, new rules, clinical requirements, and regulations will mean that the medical physicist must actively work to keep her/his sites compliant and must work closely with physicians to ensure best performance of these systems. Informatics Display 1.0 to 2.0: Medical displays are an integral part of medical imaging operation. The DICOM and AAPM (TG18) efforts have led to clear definitions of performance requirements of monochrome medical displays that can be followed by medical physicists to ensure proper performance. However, effective implementation of that oversight has been challenging due to the number and extend of medical displays in use at a facility. The advent of color display and mobile displays has added additional challenges to the task of the medical physicist. This informatics display lecture first addresses the current display guidelines (the 1.0 paradigm) and further outlines the initiatives and prospects for color and mobile displays (the 2.0 paradigm). Informatics Management 1.0 to 2.0: Imaging informatics is part of every radiology practice today. Imaging informatics covers everything from the ordering of a study, through the data acquisition and processing, display and archiving, reporting of findings and the billing for the services performed. The standardization of the processes used to manage the information and methodologies to integrate these standards is being developed and advanced continuously. These developments are done in an open forum and imaging organizations and professionals all have a part in the process. In the Informatics Management presentation, the flow of information and the integration of the standards used in the processes will be reviewed. The role of radiologists and physicists in the process will be discussed. Current methods (the 1.0 paradigm) and evolving methods (the 2.0 paradigm) for validation of informatics systems function will also be discussed. Learning Objectives: Identify requirements for improving quality assurance and compliance tools for advanced and hybrid MRI systems. Identify the need for new quality assurance metrics and testing procedures for advanced systems. Identify new hardware systems and new procedures needed to evaluate MRI systems. Understand the components of current medical physics expectation for medical displays. Understand the role and prospect fo medical physics for color and mobile display devices. Understand different areas of imaging informatics and the methodology for developing informatics standards. Understand the current status of informatics standards and the role of physicists and radiologists in the process, and the current technology for validating the function of these systems.

07 ISOTOPE AND RADIATION SOURCES↗

BSSD 2019 Performance Metric Q4

The LANL SFA in Terrestrial Microbial Carbon Cycling aims to inform climate modeling and enable carbon management in terrestrial ecosystems by discovering widespread biological processes that control carbon storage and release in temperate biome soils. To achieve these goals, computational approaches are essential to analyze increasingly complex ‘omics’ data from microbial communities in environmental samples. The SFA continues to leverage advances in ‘omics' measurement technology and computation tools to decipher microbial community function in environmental samples. The computational approach is aligned with the recent shift in the SFA’s research approach. When the SFA began 10 years ago, computational approaches principally addressed “who is there” with extremely limited insight into function. Accessible ‘omics' data for complex soil communities were primarily amplicon DNA sequences of taxonomic or functional marker genes obtained by PCR, cloning, and Sanger sequencing. Computational tools for community analysis were nascent. Over the past decade, genome resources (DOE-Integrated Microbial Genomics database) and data acquisition increased 1000-fold, common computational pipelines for many analysis tasks have arisen, and the variety of ‘omics’ measurements has expanded to routinely include shotgun metagenomics, metatranscriptomics, and versions of metabolomics. The SFA is capitalizing on these advances while also developing new computational techniques to decipher how communities with different patterns of carbon cycling function from the species to ecosystem level.

54 ENVIRONMENTAL SCIENCES↗

SU-E-I-08: Investigation of Deconvolution Methods for Blocker-Based CBCT Scatter Estimation

Purpose: To investigate whether deconvolution methods can improve the scatter estimation under different blurring and noise conditions for blocker-based scatter correction methods for cone-beam X-ray computed tomography (CBCT). Methods: An “ideal” projection image with scatter was first simulated for blocker-based CBCT data acquisition by assuming no blurring effect and no noise. The ideal image was then convolved with long-tail point spread functions (PSF) with different widths to mimic the blurring effect from the finite focal spot and detector response. Different levels of noise were also added. Three deconvolution Methods: 1) inverse filtering; 2) Wiener; and 3) Richardson-Lucy, were used to recover the scatter signal in the blocked region. The root mean square error (RMSE) of estimated scatter serves as a quantitative measure for the performance of different methods under different blurring and noise conditions. Results: Due to the blurring effect, the scatter signal in the blocked region is contaminated by the primary signal in the unblocked region. The direct use of the signal in the blocked region to estimate scatter (“direct method”) leads to large RMSE values, which increase with the increased width of PSF and increased noise. The inverse filtering is very sensitive to noise and practically useless. The Wiener and Richardson-Lucy deconvolution methods significantly improve scatter estimation compared to the direct method. For a typical medium PSF and medium noise condition, both methods (∼20 RMSE) can achieve 4-fold improvement over the direct method (∼80 RMSE). The Wiener method deals better with large noise and Richardson-Lucy works better on wide PSF. Conclusion: We investigated several deconvolution methods to recover the scatter signal in the blocked region for blocker-based scatter correction for CBCT. Our simulation results demonstrate that Wiener and Richardson-Lucy deconvolution can significantly improve the scatter estimation compared to the direct method.

60 APPLIED LIFE SCIENCES↗

Dynamic functional imaging of brain glucose utilization using fPET-FDG

We report that glucose is the principal source of energy for the brain and yet the dynamic response of glucose utilization to changes in brain activity is still not fully understood. Positron emission tomography (PET) allows quantitative measurement of glucose metabolism using 2-[18F]-fluorodeoxyglucose (FDG). However, FDG PET in its current form provides an integral (or average) of glucose consumption over tens of minutes and lacks the temporal information to capture physiological alterations associated with changes in brain activity induced by tasks or drug challenges. Traditionally, changes in glucose utilization are inferred by comparing two separate scans, which significantly limits the utility of the method. We report a novel method to track changes in FDG metabolism dynamically, with higher temporal resolution than exists to date and within a single session. Using a constant infusion of FDG, we demonstrate that our technique (termed fPET-FDG) can be used in an analysis pipeline similar to fMRI to define within-session differential metabolic responses. We use visual stimulation to demonstrate the feasibility of this method. Ultimately, this new method has a great potential to be used in research protocols and clinical settings since fPET-FDG imaging can be performed with most PET scanners and data acquisition and analysis are straightforward. fPET-FDG is a highly complementary technique to MRI and provides a rich new way to observe functional changes in brain metabolism.

2-[18F]-fluorodeoxyglucose (FDG)↗

Detection of phosphate transporter genes from arbuscular mycorrhizal fungi in mature tree roots under experimental soil pH manipulation

We present the majority of terrestrial plant roots are colonized by arbuscular mycorrhizal (AM) fungi that, in exchange for carbon, provide plants with enhanced nutrient uptake — most notably inorganic phosphate (P i ). To mediate the uptake of Pi from the soil, AM fungi possess high affinity inorganic phosphate transporters (PTs). Under laboratory conditions, P i concentrations have been shown to regulate AM fungal-specific PT gene expression. The relationship between PT expression and P i in the field remains unexplored. Here we quantify AM fungal-specific PTs from maple tree roots in situ. In an effort to limit edaphic parameters, root samples were collected from manipulated forested plots that had elevated soil P i availability, either through direct P i application or elevating pH to lower exchangeable aluminum. The aim of the study was to examine AM fungal-specific PT gene expression both prior to and following soil P i amendment; however, a direct correlation between soil P i concentration and PT gene expression was not observed. PT transcripts were detected to a greater extent under elevated pH and, while our results are confounded by an overall low detection of PT genes (23 % of all samples collected), our findings raise interesting questions regarding the role of soil pH on PT function. In conclusion, our study is a first step in understanding how edaphic properties influence PT expression and plant P acquisition in mature tree roots.

54 ENVIRONMENTAL SCIENCES↗

Identification and correction of temporal and spatial distortions in scanning transmission electron microscopy

Scanning transmission electron microscopy (STEM) has become the technique of choice for quantitative characterization of atomic structure of materials, where the minute displacements of atomic columns from high-symmetry positions can be used to map strain, polarization, octahedra tilts, and other physical and chemical order parameter fields. The latter can be used as inputs into mesoscopic and atomistic models, providing insight into the correlative relationships and generative physics of materials on the atomic level. However, these quantitative applications of STEM necessitate understanding the microscope induced image distortions and developing the pathways to compensate them both as part of a rapid calibration procedure for in situ imaging, and the post-experimental data analysis stage. Here, we explore the spatiotemporal structure of the microscopic distortions in STEM using multivariate analysis of the atomic trajectories in the image stacks. Based on the behavior of principal component analysis (PCA), we develop the Gaussian process (GP)-based regression method for quantification of the distortion function. The limitations of such an approach and possible strategies for implementation as a part of in-line data acquisition in STEM are discussed. Here, the analysis workflow is summarized in a Jupyter notebook that can be used to retrace the analysis and analyze the reader's data.

36 MATERIALS SCIENCE↗

A Preprocessing Tool for Enhanced Ion Mobility–Mass Spectrometry-Based Omics Workflows

The ability to improve the data quality of ion mobility–mass spectrometry (IM-MS) measurements is of great importance for enabling modular and efficient computational workflows and gaining better qualitative and quantitative insights from complex biological and environmental samples. We developed the PNNL PreProcessor, a standalone and user-friendly software housing various algorithmic implementations to generate new MS-files with enhanced signal quality and in the same instrument format. Different experimental approaches are supported for IM-MS based on Drift-Tube (DT) and Structures for Lossless Ion Manipulations (SLIM), including liquid chromatography (LC) and infusion analyses. The algorithms extend the dynamic range of the detection system, while reducing file sizes for faster and memory-efficient downstream processing. Specifically, multidimensional smoothing improves peak shapes of poorly defined low-abundance signals, and saturation repair reconstructs the intensity profile of high-abundance peaks from various analyte types. Further, other functionalities are data compression and interpolation, IM demultiplexing, noise filtering by low intensity threshold and spike removal, and exporting of acquisition metadata. Several advantages of the tool are illustrated, including an increase of 19.4% in lipid annotations and a two-times faster processing of LC-DT IM-MS data-independent acquisition spectra from a complex lipid extract of a standard human plasma sample. The software is freely available at https://omics.pnl.gov/software/pnnl-preprocessor.

59 BASIC BIOLOGICAL SCIENCES↗