Search NASA⌕ Search

SEARCH · Search NASA

Results for “activation volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Active Control of Fan Noise-Feasibility Study. Volume 2: Canceling Noise Source-Design of an Acoustic Plate Radiator Using Piezoceramic Actuators

The feasibility of using acoustic plate radiators powered by piezoceramic thin sheets as canceling sources for active control of aircraft engine fan noise is demonstrated. Analytical and numerical models of actuated beams and plates are developed and validated. An optimization study is performed to identify the optimum combination of design parameters that maximizes the plate volume velocity for a given resonance frequency. Fifteen plates with various plate and actuator sizes, thicknesses, and bonding layers were fabricated and tested using results from the optimization study. A maximum equivalent piston displacement of 0.39 mm was achieved with the optimized plate samples tested with only one actuator powered, corresponding to a plate deflection at the center of over 1 millimeter. This is very close to the deflection required for a full size engine application and represents a 160-fold improvement over previous work. Experimental results further show that performance is limited by the critical stress of the piezoceramic actuator and bonding layer rather than by the maximum moment available from the actuator. Design enhancements are described in detail that will lead to a flight-worthy acoustic plate radiator by minimizing actuator tensile stresses and reducing nonlinear effects. Finally, several adaptive tuning methods designed to increase the bandwidth of acoustic plate radiators are analyzed including passive, active, and semi-active approaches. The back chamber pressurization and volume variation methods are investigated experimentally and shown to be simple and effective ways to obtain substantial control over the resonance frequency of a plate radiator. This study shows that piezoceramic-based plate radiators can be a viable acoustic source for active control of aircraft engine fan noise.

Pla, F. G.↗

Active Fluids Form System-Spanning Filamentary Networks

Recent experimental realizations of liquid-liquid phase separation of active liquid crystals have offered an insight into the interaction between phase separation, ubiquitous in soft matter and biology, and chaotic active flows. Here, in this Letter, we use continuum theory to examine phase separation of an active liquid crystal and a passive fluid and report two new results. First, we provide an analytical derivation of the activity-induced suppression of the phase boundary of the coexistence region—a result first reported in simulations and experiments. We show that the shift in the critical point is a result of the balance between self-stirring active flows and phase-separating diffusive fluxes. Second, we show that this same balance is responsible for dramatically changing the morphology of the phase separated state, resulting in the emergence of a new mixed active phase consisting of a dynamical filamentous active network that invades the entire system area, trapping droplets of passive material. This structure exists even for very low volume fractions of active material. Our work provides an important step towards the goal of understanding how to use activity as a new handle for sculpting interfaces.

active nematics↗

Generic and robust method for automatic segmentation of PET images using an active contour model

Purpose: Although positron emission tomography (PET) images have shown potential to improve the accuracy of targeting in radiation therapy planning and assessment of response to treatment, the boundaries of tumors are not easily distinguishable from surrounding normal tissue owing to the low spatial resolution and inherent noisy characteristics of PET images. The objective of this study is to develop a generic and robust method for automatic delineation of tumor volumes using an active contour model and to evaluate its performance using phantom and clinical studies. Methods: MASAC, a method for automatic segmentation using an active contour model, incorporates the histogram fuzzy C-means clustering, and localized and textural information to constrain the active contour to detect boundaries in an accurate and robust manner. Moreover, the lattice Boltzmann method is used as an alternative approach for solving the level set equation to make it faster and suitable for parallel programming. Twenty simulated phantom studies and 16 clinical studies, including six cases of pharyngolaryngeal squamous cell carcinoma and ten cases of nonsmall cell lung cancer, were included to evaluate its performance. Besides, the proposed method was also compared with the contourlet-based active contour algorithm (CAC) and Schaefer’s thresholding method (ST). The relative volume error (RE), Dice similarity coefficient (DSC), and classification error (CE) metrics were used to analyze the results quantitatively. Results: For the simulated phantom studies (PSs), MASAC and CAC provide similar segmentations of the different lesions, while ST fails to achieve reliable results. For the clinical datasets (2 cases with connected high-uptake regions excluded) (CSs), CAC provides for the lowest mean RE (−8.38% ± 27.49%), while MASAC achieves the best mean DSC (0.71 ± 0.09) and mean CE (53.92% ± 12.65%), respectively. MASAC could reliably quantify different types of lesions assessed in this work with good accuracy, resulting in a mean RE of −13.35% ± 11.87% and −11.15% ± 23.66%, a mean DSC of 0.89 ± 0.05 and 0.71 ± 0.09, and a mean CE of 19.19% ± 7.89% and 53.92% ± 12.65%, for PSs and CSs, respectively. Conclusions: The authors’ results demonstrate that the developed novel PET segmentation algorithm is applicable to various types of lesions in the authors’ study and is capable of producing accurate and consistent target volume delineations, potentially resulting in reduced intraobserver and interobserver variabilities observed when using manual delineation and improved accuracy in treatment planning and outcome evaluation.

60 APPLIED LIFE SCIENCES↗

Investigating the impact of micropore volume of aminosilica functionalized SBA-15 on catalytic activity for amine-catalyzed reactions

Mesoporous materials such as SBA-15 are used in many applications since the materials are robust and have tunable properties. Whereas these materials are thought to be ideal, the materials are complex with the common synthesis methods producing materials that contain micropores. This work will investigate the impact of micropores on catalytic activity of aminosilica materials. For comparison, materials are formed using a standard method that produces materials with micropores (REG-SBA-15) and using a modified method that produces materials with negligible micropore volume (NMP-SBA-15). After grafting the calcined support with an aminosilane (either (N-methyl amino propyl) trimethoxy silane (denoted as 2°Am) or (N,N-diethyl-3-amino propyl) trimethoxy silane (3°Am)), catalytic testing experiments reveal that NMP-SBA-15 functionalized materials are more active than REG-SBA-15 functionalized materials for a range of reactions. The reactions include (a) glucose isomerization where amines interacting with surface silanols limit catalytic activity and (b) aldol and Knoevenagel chemistry where amine-silanol interactions increase the reaction rate. For aldol chemistry, the observed difference in rate is further investigated using site quantification experiments. Interestingly, the results reveal that three types of sites exist for each material, including sites that are (1) highly active, (2) intermediate active, and (3) inactive. Additionally, NMR experiments indicate that amines immobilized on REG-SBA-15 supports are less mobile than amines on NMP-SBA-15. For REG-SBA-15, the materials are found to have aminosilanes that have limited mobility and the largest fraction of inactive sites, which suggests that the inactive catalytic sites are in the micropores. Overall, the design of highly active catalytic materials can be achieved using materials that have limited micropore volumes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transport of trace contaminants through porous media

Research accomplishments in the following areas are discussed: (1) the calibration of the gas chromatograph for acetaldehyde and ethanol; (2) the development of data reduction and analysis methods; (3) the generation and analysis of experimental data for the transport of 100 ppm acetaldehyde through a cylindrical bed packed with activated carbon granules; (4) the generation and analysis of experimental data for the transport of 100 ppm ethanol through a cylindrical bed packed with activated carbon granules; and (5) a comparison of the volume adsorption capacity of activated carbon for 100 ppm concentrations of acetaldehyde, ethanol, and acetone. Activities in progress and planned activities are reviewed.

Madey, R.↗

Systems and methods for assaying a radioactive gas, and related scintillation cells

A radioactive gas assay system comprises a scintillation cell production assembly, a detector assembly, a computer assembly, and a scintillation cell destruction assembly. The scintillation cell production assembly is configured to produce a scintillation cell comprising a glass scintillator shell containing a volume of radioactive gas. The detector assembly is configured to receive the scintillation cell and to detect photons emitted thereby. The computer assembly is configured to receive data from the detector assembly to automatically calculate an absolute activity of the volume of radioactive gas of the scintillation cell and radiation detection efficiencies of the detector assembly. The scintillation cell destruction assembly is configured to receive the scintillation cell and to rupture the substantially non-porous glass scintillator shell to release the volume of radioactive gas. A method of assaying a radioactive gas, and a scintillation cell are also described.

Robinson, Troy A.↗

Ways of increasing muscular activity by means of isometric muscular exertion

The effect of isometric muscular exertion on the human body was investigated by having subjects perform basic movements in a sitting position in the conventional manner with additional muscle tension at 50% maximum force and at maximum force. The pulse, arterial pressure, skin temperature, respiratory rate, minute respiratory volume and electrical activity of the muscles involved were all measured. Performance of the exercises with maximum muscular exertion for 20 sec and without movement resulted in the greatest shifts in these indices; in the conventional manner substantial changes did not occur; and with isometric muscular exertion with 50% maximum force with and without movement, optimal functional shifts resulted. The latter is recommended for use in industrial exercises for the prevention of hypodynamia. Ten exercises are suggested.

Kovalik, A. V.↗

West coast RFI survey, volume 1, volume 2 appendix E, volume 3 appendix F, volume 4 appendix G, and volume 5 appendix H

Activities and data reported cover experimental design, mechanization onboard the aircraft, survey operations, quick look and automated data reduction, and a qualitative comparison of survey data with predicted values for the radio frequency survey. The survey was designed to measure amplitude, frequency and time of occurrence of terrestrial emissions in the VHF band during overflights of heavily populated metropolitan areas located on the Pacific Coast of the Continental United States by sensing and recording equipment installed in jet aircraft.

Deutsch, W. F.↗

Study of roles of remote manipulator systems and EVA for shuttle mission support, volume 1

Alternate extravehicular activity (EVA) and remote manipulator system (RMS) configurations were examined for their relative effectiveness in performing an array of representative shuttle and payload support tasks. Initially a comprehensive analysis was performed of payload and shuttle support missions required to be conducted exterior to a pressurized inclosure. A set of task selection criteria was established, and study tasks were identified. The EVA and RMS modes were evaluated according to their applicability for each task and task condition. The results are summarized in tabular form, showing the modes which are chosen as most effective or as feasible for each task/condition. Conclusions concerning the requirements and recommendations for each mode are presented.

Malone, T. B.↗

Phase 1 of the near term hybrid passenger vehicle development program. Appendix B: Trade-off studies, volume 1

Tradeoff study activities and the analysis process used are described with emphasis on (1) review of the alternatives; (2) vehicle architecture; and (3) evaluation of the propulsion system alternatives; interim results are presented for the basic hybrid vehicle characterization; vehicle scheme development; propulsion system power and transmission ratios; vehicle weight; energy consumption and emissions; performance; production costs; reliability, availability and maintainability; life cycle costs, and operational quality. The final vehicle conceptual design is examined.

Traversi, M.↗

Advanced composite elevator for Boeing 727 aircraft, volume 2

Preliminary design activity consisted of developing and analyzing alternate design concepts and selecting the optimum elevator configuration. This included trade studies in which durability, inspectability, producibility, repairability, and customer acceptance were evaluated. Preliminary development efforts consisted of evaluating and selecting material, identifying ancillary structural development test requirements, and defining full scale ground and flight test requirements necessary to obtain Federal Aviation Administration (FAA) certification. After selection of the optimum elevator configuration, detail design was begun and included basic configuration design improvements resulting from manufacturing verification hardware, the ancillary test program, weight analysis, and structural analysis. Detail and assembly tools were designed and fabricated to support a full-scope production program, rather than a limited run. The producibility development programs were used to verify tooling approaches, fabrication processes, and inspection methods for the production mode. Quality parts were readily fabricated and assembled with a minimum rejection rate, using prior inspection methods.

Chovil, D. V.↗

Distribution Development for Residual Inventory at the New York West Valley Site - 20400

The New York State Energy Research and Development Authority (NYSERDA) is the owner of the Western New York Nuclear Service Center (WNYNSC), a 1,351 ha site located approximately 48 km south of Buffalo, New York. In 1962, Nuclear Fuel Services, Inc. (NFS) entered into Agreements with the Atomic Energy Commission and New York State to construct the first commercial reprocessing plant of nuclear fuel in the United States. NFS, a private company, built and operated the spent fuel reprocessing plant and waste disposal facilities, processing 640 Mg of spent nuclear fuel from 1966 to 1972 under an Atomic Energy Commission license. Nuclear fuel reprocessing operations ended in 1972 and never reopened, leaving behind radioactive and chemical wastes. Operations led to contamination in a number of facilities and locations. Some of that contamination has migrated from waste disposal zones to other layers, formations, and features on and off the WNYNSC. Phase I decommissioning activities are ongoing and involve the removal of a number of areas and structures that have been associated with contamination. The purpose of this work is to outline the approach for characterizing contamination not associated with disposed wastes, contaminated structures, or specific releases. In this work, the term, residual radiological activity, is used to describe environmental contamination that exists subsequent to the completion of Phase I decommissioning activities, that is not associated with disposed wastes, contaminated structures, or specific releases. Contamination from the Site was quantified relative to data that characterize the concentrations of radionuclides that exist in background. Background concentrations are those present in the area but having no influence from Site related activities. The existence of residual radiological activity that is elevated relative to background has the potential to contribute to future risks to human health and the environment. As a consequence, the residual inventory information is used to inform the West Valley Probabilistic Performance Assessment (PPA) model to characterize potential future risks to human health and the environment. The centralized West Valley Data Management System (DMS) was the source of information for the data assembled in this analysis. The DMS is a fairly large compilation consisting of thousands of records from investigation studies, with sample dates ranging from 1990 to present. Samples from monitoring wells, boreholes, geoprobe studies, surface water, surface soils, storm water outfalls, ventilation stack filters, plant and animal tissues, and more are included in the DMS. Results are typically reported in units of activity per unit volume. For the purpose of the analyses presented here, all results were converted into consistent units of pCi per unit volume. Since 1990, data have been collected from various locations across the WNYNSC at different times with varying frequency over the course of several decades. As a consequence, a number of potential issues can arise with respect to the assembly of a dataset that is deemed adequate for the characterization of residual radiological activity. These issues were assessed and resolved to the extent possible through careful consideration of the properties of the distributions. The intent was to use data which characterize the current state of the Site. Radionuclides can be designated to one of several groups depending on their origin. In this work the groups considered were 1) Naturally Occurring Radioactive Material (NORM), 2) fallout, and 3) Other (including power plant, medical research, etc). This grouping is a useful construct with respect to the interpretation of fixed laboratory results. For example, NORM radionuclides that exist within a decay chain should have approximately equivalent distributions of concentrations if they are representative of background conditions. Insights such as these can be used as a check to identify sample results that need to be further investigated or omitted due to issues associated with reported results from fixed laboratory analyses. This type of analysis provided a foundation for the assessment of the adequacy of sample results for use in subsequent components of an assessment. The general process for the assessment of residual radiological contamination at the Site consists of a sequence of several steps. First, for each analyte, several statistical tests were performed to assess the weight of evidence against the null hypothesis that the mean of the distribution of concentrations was equal to zero. If the mean of the distribution of concentrations for a given radionuclide was not found to be greater than zero, then it was removed from consideration as a component of the residual radiological contamination. If there was significant evidence to reject the hypothesis of the mean being equal to zero, the second step was to compare the distribution of the data from the Site to that of the corresponding background. A suite of tests was used to compare the distributions of the site and background data. The results of these tests were collectively used to determine if site data are elevated relative to background. The third step was to develop distributions using a Bayesian framework to characterize the distribution of mean of the increment present above background for each of the radionuclides. The Bayesian model implemented allowed for the comparison of site-specific records to background concentrations to better approximate contamination attributed to the Site. A final screening step was employed for radionuclides that exceed background. This screening step compared 95% upper confidence limits (UCLs) from the increment distribution developed in the previous step to the risk screening levels. This approach yields a list of analytes that were determined to be elevated relative to background.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toward a model for leveed lava flows

Many lava flows have two distinct volumetric components during emplacement. First, there is a component actively flowing in accordance with Newtonian or other constitutive relations. Second, there may be an inactive, stationary component that is no longer participating in the forward movement of the flow. Such passive components may take the form of flow-confining levees, solidified lateral margins, overspilling, plating, small ponds and sidestreams, or a lava tube. To describe the conservation of flow volume for the active component, governing equations are given and discussed.

Baloga, Stephen↗

Cardiovascular Deconditioning in Humans: Alteration in Cardiovascular Regulation and Function During Simulated Microgravity

Alterations in cardiovascular regulation and function that occur during and after space flight have been reported. These alterations are manifested, for example, by reduced orthostatic tolerance upon reentry to the earth's gravity from space. However, the precise physiologic mechanisms responsible for these alterations remain to be fully elucidated. Perhaps, as a result, effective countermeasures have yet to be developed. In this project we apply a powerful, new method - cardiovascular system identification (CSI) - for the study of the effects of space flight on the cardiovascular system so that effective countermeasures can be developed. CSI involves the mathematical analysis of second-to-second fluctuations in non-invasively measured heart rate, arterial blood pressure (ABP), and instantaneous lung volume (ILV - respiratory activity) in order to characterize quantitatively the physiologic mechanisms responsible for the couplings between these signals. Through the characterization of all the physiologic mechanisms coupling these signals, CSI provides a model of the closed-loop cardiovascular regulatory state in an individual subject. The model includes quantitative descriptions of the heart rate baroreflex, autonomic function, as well as other important physiologic mechanisms. We are in the process of incorporating beat-to-beat fluctuations of stroke volume into the CSI technique in order to quantify additional physiologic mechanisms such as those involved in control of peripheral vascular resistance and alterations in cardiac contractility. We apply CSI in conjunction with the two general protocols of the Human Studies Core project. The first protocol involves ground-based, human head down tilt bed rest to simulate microgravity and acute stressors - upright tilt, standing and bicycle exercise - to provide orthostatic and exercise challenges. The second protocol is intended to be the same as the first but with the addition of sleep deprivation to determine whether this contributes to cardiovascular alterations. In these studies, we focus on the basic physiologic mechanisms responsible for the alterations in cardiovascular regulation and function during the simulated microgravity in order to formulate hypotheses regarding what countermeasures are likely to be most effective. Compared to our original proposal, the protocol we are using has been slightly modified to lengthen the bed rest period to 16 days and streamline the data collection. These modifications provide us data on a longer bed rest period and have enabled us to increase our subject throughput. Based on review of our preliminary data we have decided to test a countermeasure which is applied the very end of the bed rest period. We will use the same bed rest protocol to test this countermeasure. We anticipate completing the baseline data collection in our first protocol plus testing of the countermeasure in an additional eight subjects, at which time we plan to initiate the second protocol which includes sleep deprivation. In future studies, we plan to apply CSI to test other potential countermeasures in conjunction with the same bed rest, sleep deprivation and acute stressor models. We also anticipate applying CSI for studying astronauts before and after space flight and ultimately, during space flight. The application of CSI is providing information relevant to the development and evaluation of effective countermeasures allowing humans to adapt appropriately upon re-exposure to a gravity field, and to live and work for longer periods of time in microgravity.

Cohen, Richard↗

Physical conditions in the solar atmosphere above an active region

From a series of EUV spectra obtained at several heights above the limb in a solar active region, the volume emission measure is derived as a function of the electron temperature in the temperature range 70,000-1,500,000 K and the electron density at two locations. The emission measure from the coronal material (temperature greater than 700,000 K) is nearly the same everywhere and represents most of the material in the line of sight, while the emission measure from the transition region material (temperature between 70,000 and 250,000 K) fluctuates by two orders of magnitude from position to position above the active region. This is in agreement with the picture of this active region as consisting of a number of well-defined loops or lower portions of loops at transition region temperatures that are inhomogeneously distributed in much larger and more diffuse loop structures at coronal temperatures. The coronal data are in reasonable agreement with simple coronal models. Emission measures near 1,000,000 K evaluated using different ions differ by a factor of 4, suggesting difficulties with the atomic physics data.

Mariska, J. T.↗

Determinants and Expansion of Specificity in a Trichothecene UDP-Glucosyltransferase from Oryza sativa

Family 1 UDP-glycosyltransferases (UGTs) in plants primarily form glucose conjugates of small molecules and, besides other functions, play a role in detoxification of xenobiotics. Indeed, overexpression of a barley UGT in wheat has been shown to control Fusarium head blight, which is a plant disease of global significance that leads to reduced crop yields and contamination with trichothecene mycotoxins such as deoxynivalenol (DON), T-2 toxin, and many other structural variants. The UGT Os79 from rice has emerged as a promising candidate for inactivation of mycotoxins because of its ability to glycosylate DON, nivalenol, and hydrolyzed T-2 toxin (HT-2). However, Os79 is unable to modify T-2 toxin (T-2), produced by pathogens such as Fusarium sporotrichioides and Fusarium langsethii. Activity toward T-2 is desirable because it would allow a single UGT to inactivate co-occurring mycotoxins. Here, the structure of Os79 in complex with the products UDP and deoxynivalenol 3-O-glucoside is reported together with a kinetic analysis of a broad range of trichothecene mycotoxins. Residues associated with the trichothecene binding pocket were examined by site-directed mutagenesis that revealed that trichothecenes substituted at the C4 position, which are not glycosylated by wild-type Os79, can be accommodated in the binding pocket by increasing its volume. The H122A/L123A/Q202L triple mutation, which increases the volume of the active site and attenuates polar contacts, led to strong and equivalent activity toward trichothecenes with C4 acetyl groups. Lastly, this mutant enzyme provides the broad specificity required to control multiple toxins produced by different Fusarium species and chemotypes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Air Exchange Rate Impact on Activity Equilibrium Factors and Inhalation Fractional Equilibrium Factors for Rn, Xe, Kr, Ar, Ne, and Their Progeny in Vapor Intrusion, Risk, and Dose Models

Exposure to the radioactive noble gasses, especially radon, is of high concern and poses a significant risk to humans in an indoor air environment as the second leading cause of lung cancer in the United States. To evaluate and minimize the risks posed by these gasses, it is important to understand their radiological and physical properties. The EPA’s Radon Vapor Intrusion Screening Level (RVISL) calculator calculates indoor air RVISLs based on target working levels (WLs), target excess lifetime cancer risk (ELCR), and annual dose limits for the actinon (Rn-219), thoron (Rn-220), and radon (Rn-222) decay series. The RVISLs are based on inhalation and submersion in gas cloud exposure routes for residential and commercial settings. The RVISLs are analogous to preliminary remediation goals (PRGs) and dose compliance concentrations (DCCs), where the isotope-specific values are in units of activity concentration (activity per unit volume). If the concentration of a parent isotope of radon or its progeny is found to exceed the RVISL, then further action to ensure cleanup of the contaminant may be necessary. In residential and commercial settings, the RVISLs will vary based on the air exchange rate present. The EPA’s Radionuclide PRG and DCC Calculators also assess the risk/dose from noble gases in the air due to household use of water like showering. In this study, a computational method in MATLAB was developed to determine the impact of the air exchange rate on the activity equilibrium factor (A eq ) and the inhalation fractional equilibrium factor (F eq ). Both factors are values that reflect the equilibrium concentrations of progeny to their parent in the air. These factors have a direct impact on the RVISL, PRG, and DCC calculations of WL, ELCR, and annual dose, respectively. This study builds on a previous report that only focused on actinon, thoron, and radon by revisiting the original A eq and F eq calculation methods, as well as including the values for the Rn-207, Rn-209, Rn-210, Rn-211, Rn-215, Rn-216, Rn-217, Rn-218, Rn-223, Ne-24, Ar-42, Ar-43, Ar-44, Kr-74, Kr-75, Kr-76, Kr-77, Kr-88, Kr-89, Xe-120, Xe-121, Xe-122, Xe-123, Xe-135m, and Xe-138 decay chains, which are not currently available in literature. The EPA’s RVISL calculator will be updated to include the new A eq and F eq values for the actinon, thoron, and radon decay chains, while the rest of the calculators will incorporate all the new A eq and F eq values as appropriate.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗