Adhesive evaluation of water-soluble LARC-TPI

The water-soluble polyimide, identified as TPI(MTC)/H2O, was evaluated as a high temperature thermoplastic adhesive for bonding Ti-6Al-4V and comparing those results primarily with results reported in earlier work with the polyamic-acid/diglyme material. The lap shear strength test was the primary test performed to evaluate the adhesive before (controls) and after thermal exposure in air at 204 C for up to 5000 hours and after a 72 hour water-boil exposure. Lap shear strengths were determined at RT, 177, 204, and 232 C. The adhesive was also characterized after fracture by determining the glass transition temperature as well as defining the mode of failure by visual observation. In general, the results indicate that the TPI(MTC)/H2O retains high lap shear strengths after thermal exposure but had reduced strengths after the water-boil exposure. All failures were cohesive. The TPI(MTC)/H2O compared very well with previous data reported for the standard polyamic-acid/diglyme LARC-TPI results, and therefore, shows promise as a water-soluble adhesive for use in various applications.

Progar, D. J.↗

A fundamental approach to adhesion: Synthesis, surface analysis, thermodynamics and mechanics

The effects of composites as adherends was studied. Several other variables were studied by fractography: aluminum powder adhesive filler, fiber glass cloth scrim or adhesive carrier, new adhesives PPQ-413 and LARC-13, and strength-test temperature. When the new results were juxtaposed with previous work, it appeared that complex interactions between adhesive, adherend, bonding, and testing conditions govern the observed strength and fracture-surface features. The design parameters likely to have a significant effect upon strength-test results are listed.

Dwight, D. W.↗

Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10-8 Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust stimulant processing capabilities: heating and cooling while stirring in order to degas and remove absorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions, and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples

Gaier, James R.↗

Evaluation of non-specular reflecting silvered Teflon and filled adhesives

A non-specular silver-Teflon tape thermal control coating was tested to provide the data necessary to qualify it for use on the Space Shuttle Orbiter radiators. Effects of cure cycle temperature and pressure on optical and mechanical properties on the silver-Teflon tape were evaluated. The baseline Permacel P-223 adhesive, used with the specular silver-Teflon tape initially qualified for the Orbiter radiators, and four alternate metal-filled and unfilled adhesives were evaluated. Tests showed the cure process has no effect on the silver-Teflon optical properties, and that the baseline adhesive cure cycle gives best results. In addition the P-223 adhesive bond is more reproducible than the alternates, and the non-specular tape meets both the mechanical and the optical requirements of the Orbiter radiator coating specification. Existing Orbiter coating techniques were demonstrated to be effective in aplying the non-specular tape to a curved panel simulating the radiators. Author

Bourland, G.↗

Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.

Gaier, James R.↗

Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.

Gaier, James R.↗

Force instrumentation for cryogenic wind tunnels using one-piece strain-gage balances

The use of cryogenic temperatures in wind tunnels to achieve high Reynolds numbers has imposed a harsh operating environment on the force balance. Laboratory tests were conducted to study the effect cryogenic temperatures have on balance materials, gages, wiring, solder, adhesives, and moisture proofing. Wind tunnel tests were conducted using a one piece three component balance to verify laboratory results. These initial studies indicate that satisfactory force data can be obtained under steady state conditions.

Ferris, A. T.↗

Lunar Dust Simulant Particle Adhesion on Copolyimide Alkyl Ethers

Mitigation of lunar dust contamination is one of the greatest challenges to be overcome to realize a sustained lunar presence. Likely solutions will integrate active mitigation strategies, requiring the input of external energy, and passive materials, exhibiting an intrinsic resistance to lunar dust adhesion. In this work, a series of copolyimide alkyl ethers containing per fluorinated side-chains were generated to evaluate the influence surface modification agents have on surface chemical, topographical, and mechanical properties. An expanded testing protocol to characterize the adhesion interaction between lunar dust simulant and the copolyimide substrate was carried out. The interfacial adhesion strength was in-situ measured by a custom-built particulate adhesion instrument, utilizing a sonic wand. Surface mechanical properties were characterized by nanoindentation, utilizing the continuous stiffness measurement approach. A nominal presence of surface modifying agents, 1 wt%, resulted in a six-fold reduction in adhesion strength of the interface. A strong inverse correlation between the adhesion strength and Young’s modulus of the substrate was identified. The reduction was attributed to a synergistic interaction between the surface energy, surface roughness, and modulus of the copolyimide alkyl ethers film.

Lunar Dust, Particulate Adhesion, Surface Migratio↗

High-Temperature Adhesive Strain Gage Developed

Researchers at the NASA Lewis Research Center have developed a unique strain gage and adhesive system for measuring the mechanical properties of polymers and polymer composites at elevated temperatures. This system overcomes some of the problems encountered in using commercial strain gages and adhesives. For example, typical commercial strain gage adhesives require a postcure at temperatures substantially higher than the maximum test temperature. The exposure of the specimen to this temperature may affect subsequent results, and in some cases may be higher than the glass-transition temperature of the polymer. In addition, although typical commercial strain gages can be used for short times at temperatures up to 370 C, their long-term use is limited to 230 C. This precludes their use for testing some high-temperature polyimides near their maximum temperature capability. Lewis' strain gage and adhesive system consists of a nonencapsulated, unbacked gage grid that is bonded directly to the polymer after the specimen has been cured but prior to the normal postcure cycle. The gage is applied with an adhesive specially formulated to cure under the specimen postcure conditions. Special handling, mounting, and electrical connection procedures were developed, and a fixture was designed to calibrate each strain gage after it was applied to a specimen. A variety of tests was conducted to determine the performance characteristics of the gages at elevated temperatures on PMR-15 neat resin and titanium specimens. For these tests, which included static tension, thermal exposure, and creep tests, the gage and adhesive system performed within normal strain gage specifications at 315 C. An example of the performance characteristics of the gage can be seen in the figure, which compares the strain gage measurement on a polyimide specimen at 315 C with an extensometer measurement.

Pereira, J. Michael↗

Study of payload sensor contamination

Epoxy/glass test specimens representing Scout fourth and fifth stage motor casings were prepared and studied in a test program designed to determine the relative contamination contributed to payload sensors located near the motor casings. The relative contamination detected in the test program was dependent on several factors, including: (1) distance of test specimen to sensor, (2) sensor temperature, (3) geometric position of the sensor (relative to test specimen), (4)test specimen temperature, (5) chemical composition of the test specimen, (6) sensor function, and (7) additional materials (such as adhesive-backed aluminum tape) added to the test specimens. The thermal characteristics and the decomposition and outgassing products were determined. These data were used to better understand the relative contamination data from the remote sensor testing.

Smith, F. J.↗

Development of low cost, high reliability sealing techniques for hybrid microcircuit packages, phase 2

Adhesives were evaluated to determine if they qualify for application to hybrid microcircuit packages. The effort consisted of the following: (1) seal gold-plated Kovar packages with selective adhesives and determine seal integrity after exposure to temperature humidity environments; (2) seal both gold-plated Kovar and ceramic packages with the four best adhesives identified in (1) and determine seal integrity after exposure to MIL-STD-883A test environments; and (3) subject the best adhesive identified in (2) to a 60 C/98% RH environment and determine susceptibility to moisture permeation. Test results are provided.

Perkins, K. L.↗

BSM Delta Qualification 2, volume 3, book 2

This report, presented in three volumes, provides the results of a two-motor Delta Qualification 2 program conducted in 1993 to certify the following enhancements for incorporation into booster separation motor (BSM0 flight hardware: vulcanized-in-place nozzle aft closure insulation; new iso-static ATJ bulk graphite throat insert material, adhesive EA9394 for bonding the nozzle throat, igniter grain rod/centering insert/igniter case; deletion of the igniter adapter insulator ring; deletion of the igniter adapter/igniter case interface RTV; and deletion of loctite from igniter retainer plate threads. The enhancements above directly resulted from (1) the BSM total quality management (TQM) team initiatives to enhance the BSM producibility, and (2) the necessity to qualify new throat insert and adhesive systems to replace existing materials that will not be available. Testing was completed at both the component and motor levels. Component testing was accomplished to screen candidate materials (e.g., throat materials, adhesive systems) and to optimize processes (e.g., aft closure insulator vulcanization approach) prior to their incorporation into the test motors. Motor testing--consisting of two motors, randomly selected by USBI's on-site quality personnel from production lot AAY, which were modified to accept the enhancements -- was completed to provide the final qualification of the enhancements for incorporation into flight hardware. Volume 3, Book 2 provides various supporting documentation to the previous volumes with regards to the testing of the two Delta qualification units: data acceptance records, thermal conditioning analysis, igniter adapter thermal flake analysis, laboratory adhesive (EA-9394) qualification report, throat insert thermal/structural analysis, Delta Qualification Nonconformance Reports (NCR's), O-ring seating tests, and interim test report for vulcanization process qualification.

Source record↗

Development of acceptance criteria for batches of silane primer for external tank thermal protection system bonding applications

Fourier transform infrared spectroscopy is currently the best technique for observing hydrolytic changes in DC 1200 silane the primers caused by moisture in the atmosphere. To further prove that FTIR can be used as a criterion test for acceptance of silane primer lots, intensities of the FTIR OH- band are being compared with primer adhesive bond strength using a mechanical test suggested by NASA. Results of tests for shear strength and Oh-absorption are tabulated and compared with FTIR absorption intensities in the OH-region.

Mikes, F.↗

Investigation of low cost, high reliability sealing techniques for hybrid microcircuits, phase 1

A preliminary investigation was made to determine the feasibility of using adhesive package sealing for hybrid microcircuits. Major effort consisted of: (1) surveying representative hybrid manufacturers to assess the current use of adhesives for package sealing; (2) making a cost comparison of metallurgical versus adhesive package sealing; (3) determining the seal integrity of gold plated flatpack type packages sealed with selected adhesives, thermal shock, temperature cycling, mechanical shock, and constant acceleration test environments; and (4) defining a more comprehensive study to continue the evaluation of adhesives for package sealing. Results showed that 1.27 cm square gold plated flatpack type packages sealed with the film adhesives and the paste adhesive retained their seal integrity after all tests, and that similarly prepared 2.54 cm square packages retained their seal integrity after all tests except the 10,000 g's constant acceleration test. It is concluded that these results are encouraging, but by no means sufficient to establish the suitability of adhesives for sealing high reliability hybrid microcircuits.

Perkins, K. L.↗

When SLIPS meets TIPS: An endogenous lubricant-infused surface by taking the diluent as the lubricant

Slippery lubricant-infused porous surfaces (SLIPSs) hold great promise in fields requiring adhesion resistance such as self-cleaning, anti-fouling, anti-icing, and anti-scaling. However, their road to practical application is still blocked by the complicated fabrication process and the restricted coating area. To address these challenges, we propose a new concept of endogenous SLIPS in which the porous structure grows from the solution coating of polypropylene/caprylyl methicone undergoing a thermally induced phase separation (TIPS) process. Caprylyl methicone serves as the diluent during TIPS as well as the lubricant in the SLIPS so that the coating can be fabricated in one step and unrestrictedly. Furthermore, the dissolution and phase separation mechanisms have been revealed by molecular dynamic simulation and in situ microscopic observation. Such SLIPSs exhibits impressive sliding property even for sticky and viscous liquids and exhibit extremely low ice adhesion in anti-icing tests.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Test Plan to Investigate the Optimal Cure Schedule of an Epoxy Resin for Its Application as an Adhesive in Optocouplers

Epoxy resins are polymeric materials that are known for their versatility, low cost, and strong thermal and mechanical properties. They can be used as coatings, adhesives, automotive primers, and have become staples in electronics, aerospace composites and semiconductor encapsulates. Recently, LANL has experienced a decline in the quality of a specialized electronic device, called an optocoupler, which is normally acquired from commercial suppliers. Because of this, a group at LANL is exploring the feasibility of in-house manufacturing of an optocoupler that is better suited for their application. The current prototype has resulted in adhesive failure after being exposed to several thermal cycles. There is a need to investigate the possible reasons for this failure, particularly how the cure schedule of the epoxy might affect its adhesive strength over time and in cycled temperatures. To assist in this investigation, a test plan has been developed involving multiple experiments using thermomechanical analysis (TMA), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC).

36 MATERIALS SCIENCE↗

LARC-13 adhesive development

The paper reports the results of a program whose objective was to modify physically and chemically LARC-13 resin in order to obtain an improved adhesive for 589 K applications. The project was directed, in particular, toward Space Shuttle applications such as the body flap in which the designers could take the advantage of the excellent strength-to-weight ratio of advanced composites. Improved resins were obtained by substitution of m, m-prime-diaminodiphenylmethane with metaphenylene diamine in the original LARC-13 chemistry. Test results for the new adhesives are presented.

Hill, S. G.↗