Search NASA⌕ Search

SEARCH · Search NASA

Results for “agile,”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

In-flight testing of onboard UHF equipment

This paper proposes a plan to allow future flight projects to accomplish in-flight testing of on-board UHF equipment which the spacecraft carries for local relay link use at planet Mars only. This plan relies on onboard self-testing to verify receiver functional capabilities at various data rates, and on RF testing with narrow band CW signals transmitted at selected frequencies from an Earth station, non-interfering to existing UHF users, to verify the RF performance of antenna and microwave equipment. The Mars mission planners at JPL have accepted this concept as reasonable. The plan will be practical to implement with a frequency agile local link transceiver, like the next generation UHF transceiver being developed at JPL. The user can test it at one frequency and operate it at a different frequency within the operating range. Possible frequencies for uplink testing are identified. Further effort is needed to select specific test frequencies that will be agreeable to the users to which these bands are allocated.

UHF in-flight testing↗

On-wafer vector network analyzer measurements in the 220-325 Ghz frequency band

We report on a full two-port on-wafer vector network analyzer test set for the 220-325 GHz (WR3) frequency band. The test set utilizes Oleson Microwave Labs frequency extenders with the Agilent 8510C network analyzer. Two port on-wafer measurements are made with GGB Industries coplanar waveguide (CPW) probes. With this test set we have measured the WR3 band S-parameters of amplifiers on-wafer, and the characteristics of the CPW wafer probes. Results for a three stage InP HEMT amplifier show 10 dB gain at 235 GHz [1], and that of a single stage amplifier, 2.9 dB gain at 231 GHz. The approximate upper limit of loss per CPW probe range from 3.0 to 4.8 dB across the WR3 frequency band.

coplanar waveguides↗

Future Gamma-Ray Observations of Pulsars and their Environments

Pulsars and pulsar wind nebulae seen at gamma-ray energies offer insight into particle acceleration to very high energies under extreme conditions. Pulsed emission provides information about the geometry and interaction processes in the magnetospheres of these rotating neutron stars, while the pulsar wind nebulae yield information about high-energy particles interacting with their surroundings. During the next decade, a number of new and expanded gamma-ray facilities will become available for pulsar studies, including Astro-rivelatore Gamma a Immagini LEggero (AGILE) and Gamma-ray Large Area Space Telescope (GLAST) in space and a number of higher-energy ground-based systems. This review describes the capabilities of such observatories to answer some of the open questions about the highest-energy processes involving neutron stars.

Thompson, David J.↗

From Zero to Integration in Eight Months, the Dawn Ground Data System Engineering Challenge

The Dawn GDS Team met the SC Sim integration challenge in eight months. The GDS System Engineering approach in response to the SC Simintegration challenge, focused on a set of key practices: decomposition of project request into manageable requirements; integration of multiple ground disciplines and experts into a focused team effort; risk management thru management of expectations; and aggregation of intermediate products into a final product. By maintaining a a system-level focus, the overall systems engineering process unified team GDS Team members with a common goal: the success of the ground system as a whole and not just the success of their individual expert contributions. Incorporation of Agile-type development efforts were aligned with a risk strategy based on team-oriented principles and expectations management, thus achieving a more stable baseline solution without compromising the integrity of the GDS design.

Dawn Mission↗

A Compact 600 GHz Electronically Tunable Vector Measurement System for Submillimeter Wave Imaging

A compact submillimeter wave transmission / reflection measurement system has been demonstrated at 560-635 GHz, with electronic tuning over the entire band. Maximum dynamic range measured at a single frequency is 90 dB (60 dB typical), and phase noise is less than +/- 2(deg). By using a frequency steerable lens at the source output and mixer input, the frequency agility of the system can be used to scan the source and receive beams, resulting in near real-time imaging capability using only a single pixel.

submillimeter wave imaging↗

Determination of Scopolamine in Human Saliva Using Solid Phase Extraction and LC/MS/MS

Purpose: Scopolamine is the preferred treatment for motion sickness during space flight because of its quick onset of action, short half-life and favorable side-effect profile. The dose administered depends on the mode of administration and usually ranges between 0.1 and 0.8 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids by using conventional HPLC methods. To measure scopolamine in saliva and thereby to evaluate the pharmacokinetics of scopolamine, we developed an LC/MS/MS method using off-line solid phase extraction. Method: Samples (0.5mL) were loaded onto Waters Oasis HLB co-polymer cartridges (10 mg, 1 mL) and eluted with 0.5 mL methanol without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 4 minutes. The mobile phase for separation was 90:10 (v/v) methanol: ammonium acetate (2 mM) in water, pH 5.0 +/- 0.1. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 yields 138.1 and internal standard (IS) hyoscyamine m/z = 290.2 yields 124.1. Results: The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at 1.7 and 3.2 min respectively. The linear range is 50-5000 pg/mL for scopolamine in saliva with correlation coefficients > 0.99 with a CV < 0.5 %. The intra-day and inter-day CVs are < 15 % for quality control samples with concentrations of 75, 300, 750 and 3000 pg/mL of scopolamine in human saliva. Conclusion: Solid phase extraction allows more rapid sample preparation and greater precision than liquid extraction. Furthermore, we increased the sensitivity and specificity by adjusting the LC mobile phase and using an MS/MS detector.

Wang, Zuwei↗

CFD to Flight: Some Recent Success Stories of X-plane Design to Flight Test at the NASA Dryden Flight Research Center

Several examples from the past decade of success stories involving the design and ight test of three true X-planes will be described: in particular, X-plane design techniques that relied heavily upon computational fluid dynamics (CFD). Three specific examples chosen from the authors personal experience are presented: the X-36 Tailless Fighter Agility Research Aircraft, the X-45A Unmanned Combat Air Vehicle, and, most recently, the X-48B Blended Wing Body Demonstrator Aircraft. An overview will be presented of the uses of CFD analysis, comparisons and contrasts with wind tunnel testing, and information derived from the CFD analysis that directly related to successful flight test. Some lessons learned on the proper application, and misapplication, of CFD are illustrated. Finally, some highlights of the flight-test results of the three example X-planes will be presented. This overview paper will discuss some of the authors experience with taking an aircraft shape from early concept and three-dimensional modeling through CFD analysis, wind tunnel testing, further re ned CFD analysis, and, finally, flight. An overview of the key roles in which CFD plays well during this process, and some other roles in which it does not, are discussed. How wind tunnel testing complements, calibrates, and verifies CFD analysis is also covered. Lessons learned on where CFD results can be misleading are also given. Strengths and weaknesses of the various types of ow solvers, including panel methods, Euler, and Navier-Stokes techniques, are discussed. The paper concludes with the three specific examples, including some flight test video footage of the X-36, the X-45A, and the X-48B.

Cosentino, Gary B.↗

A Sequential Shifting Algorithm for Variable Rotor Speed Control

A proof of concept of a continuously variable rotor speed control methodology for rotorcraft is described. Variable rotor speed is desirable for several reasons including improved maneuverability, agility, and noise reduction. However, it has been difficult to implement because turboshaft engines are designed to operate within a narrow speed band, and a reliable drive train that can provide continuous power over a wide speed range does not exist. The new methodology proposed here is a sequential shifting control for twin-engine rotorcraft that coordinates the disengagement and engagement of the two turboshaft engines in such a way that the rotor speed may vary over a wide range, but the engines remain within their prescribed speed bands and provide continuous torque to the rotor; two multi-speed gearboxes facilitate the wide rotor speed variation. The shifting process begins when one engine slows down and disengages from the transmission by way of a standard freewheeling clutch mechanism; the other engine continues to apply torque to the rotor. Once one engine disengages, its gear shifts, the multi-speed gearbox output shaft speed resynchronizes and it re-engages. This process is then repeated with the other engine. By tailoring the sequential shifting, the rotor may perform large, rapid speed changes smoothly, as demonstrated in several examples. The emphasis of this effort is on the coordination and control aspects for proof of concept. The engines, rotor, and transmission are all simplified linear models, integrated to capture the basic dynamics of the problem.

Litt, Jonathan S.↗

CMG-Augmented Control of a Hovering VTOL Platform

This paper describes how Control Moment Gyroscopes (CMGs) can be used for stability augmentation to a thrust vectoring system for a generic Vertical Take-Off and Landing platform. The response characteristics of the platform which uses only thrust vectoring and a second configuration which includes a single-gimbal CMG array are simulated and compared for hovering flight while subject to severe air turbulence. Simulation results demonstrate the effectiveness of a CMG array in its ability to significantly reduce the agility requirement on the thrust vectoring system. Albeit simplifying physical assumptions on a generic CMG configuration, the numerical results also suggest that reasonably sized CMGs will likely be sufficient for a small hovering vehicle.

Lim, K. B.↗

High-Energy Emission from Rotation-Powered Pulsars

Thirty-five years after the discovery of rotation-powered pulsars, we still do not understand their pulsed emission at any wavelength. In the last few years there have been some fundamental developments in acceleration and emission models. I will review both the basic physics of the models as well as the latest developments in understanding the high-energy emission of rotation-powered pulsars. Special and general relativistic effects play important roles in pulsar emission, from inertial frame-dragging near the stellar surface to aberration, time-of-flight and retardation of the magnetic field near the light cylinder. Understanding how these effects determine what we observe at different wavelengths is critical to unraveling the emission physics. Fortunately two new gamma-ray telescopes, AGILE and GLAST, with launches expected this year will detect many new gamma-ray pulsars and test the predictions of these models with unprecedented sensitivity and energy resolution for gamma-rays in the range of 30 MeV to 300 GeV.

Harding, Alice K.↗

Science Archives in the 21st Century: A NASA LAMBDA Report

Lambda is a thematic data center that focuses on serving the cosmic microwave background (CMB) research community. LAMBDA is an active archive for NASA's Cosmic Background Explorer (COBE) and Wilkinson Microwave Anisotropy Probe (WMAP) mission data sets. In addition, LAMBDA provides analysis software, on-line tools, relevant ancillary data and important web links. LAMBDA also tries to preserve the most important ground-based and suborbital CMB data sets. CMB data is unlike other astrophysical data, consisting of intrinsically diffuse surface brightness photometry with a signal contrast of the order 1 part in 100,000 relative to the uniform background. Because of the extremely faint signal levels, the signal-to-noise ratio is relatively low and detailed instrument-specific knowledge of the data is essential. While the number of data sets being produced is not especially large, those data sets are becoming large and complex. That tendency will increase when the many polarization experiments currently being deployed begin producing data. The LAMBDA experience supports many aspects of the NASA data archive model developed informally over the last ten years-that small focused data centers are often more effective than larger more ambitious collections, for example; that data centers are usually best run by active scientists; that it can be particularly advantageous if those scientists are leaders in the use of the archived data sets; etc. LAMBDA has done some things so well that they might provide lessons for other archives. A lot of effort has been devoted to developing a simple and consistent interface to data sets, for example; and serving all the documentation required via simple 'more' pages and longer explanatory supplements. Many of the problems faced by LAMBDA will also not surprise anyone trying to manage other space science data. These range from persuading mission scientists to provide their data as quickly as possible, to dealing with a high volume of nuisance (spam) messages. Because so many data center problems and solutions are common across individual data centers and disciplines it would be very valuable to establish some new systems of communication - such as informal email lists for administrators and developers. But resources are very limited, so new timeconsuming and inefficient mechanisms - like too-frequent and too-structured meetingsshould be avoided. Although there are great advantages to being small, agile and independent, there are also some areas where science data centers within and without NASA could be better coordinated - for the assignment of persistent identifiers; to encourage the early adoption of useful standards and technologies; etc. Some super-structure to facilitate such coordination might be beneficial as long as it doesn't begin to control the other work of the archives, and become a "methodology police". In this respect the CCSDS "Reference Model for an Open Archive Information System" is a little worrying. It may be that the closer a data center gets to following such a detailed prescription, the less effective it will become. It is much better to have an informal coordination process than a bureaucratic straight-jacket.

Butterworth, P.↗

Gamma-Ray Pulsar Studies with GLAST

This viewgraph presentation reviews the prospects of extending the understanding of gamma ray pulsars, and answering the open questions left from the limited observations that are available from current observatories. There are 2 new gamma ray observatories that are either on orbit or will be shortly launched: (1) Astro-rivelatore Gamma a Immagini LEggero (AGILE), and Gamma-ray Large Area Space Telescope (GLAST). On board GLAST there will be two instruments Large Area Telescope (LAT), and GLAST Burst Monitor (GBM).

Thompson, David J.↗

Concepts and Technologies for Synthetic Aperture Radar from MEO and Geosynchronous orbits

The area accessible from a spaceborne imaging radar, e.g. a synthetic aperture radar (SAR), generally increases with the elevation of the satellite while the map coverage rate is a more complicated function of platform velocity and beam agility. The coverage of a low Earth orbit (LEO) satellite is basically given by the fast ground velocity times the relatively narrow swath width. The instantaneously accessible area will be limited to some hundreds of kilometers away from the sub-satellite point. In the other extreme, the sub-satellite point of a SAR in geosynchronous orbit will move relatively slowly, while the area which can be accessed at any given time is very large, reaching thousands of kilometers from the subsatellite point. To effective1y use the accessibility provided by a high vantage point, very large antennas with electronically steered beams are required.

spaceborne interferometric SAR (InSAR) ,↗

An Integrated Approach to Risk Assessment for Concurrent Design

This paper describes an approach to risk assessment and analysis suited to the early phase, concurrent design of a space mission. The approach integrates an agile, multi-user risk collection tool, a more in-depth risk analysis tool, and repositories of risk information. A JPL developed tool, named RAP, is used for collecting expert opinions about risk from designers involved in the concurrent design of a space mission. Another in-house developed risk assessment tool, named DDP, is used for the analysis.

defect detection and prevention (DDP)↗

Advances in Scanning Reflectarray Antennas Based on Ferroelectric Thin Film Phase Shifters for Deep Space Communications

Though there are a few examples of scanning phased array antennas that have flown successfully in space, the quest for low-cost, high-efficiency, large aperture microwave phased arrays continues. Fixed and mobile applications that may be part of a heterogeneous exploration communication architecture will benefit from the agile (rapid) beam steering and graceful degradation afforded by phased array antennas. The reflectarray promises greater efficiency and economy compared to directly-radiating varieties. Implementing a practical scanning version has proven elusive. The ferroelectric reflectarray, under development and described herein, involves phase shifters based on coupled microstrip patterned on Ba(x)Sr(1-x)TiO3 films, that were laser ablated onto LaAlO3 substrates. These devices outperform their semiconductor counterparts from X- through and K-band frequencies. There are special issues associated with the implementation of a scanning reflectarray antenna, especially one realized with thin film ferroelectric phase shifters. This paper will discuss these issues which include: relevance of phase shifter loss; modulo 2(pi) effects and phase shifter transient effects on bit error rate; scattering from the ground plane; presentation of a novel hybrid ferroelectric-semiconductor phase shifter; and the effect of mild radiation exposure on phase shifter performance.

Romanofsky, Robert R.↗

CFD to Flight: Some Recent Success Stories of X-Plane Design to Flight Test at the NASA Dryden Flight Research Center

Several examples from the past decade of success stories involving the design and flight test of three true X-planes will be described: in particular, X-plane design techniques that relied heavily upon computational fluid dynamics (CFD). Three specific examples chosen from the author s personal experience are presented: the X-36 Tailless Fighter Agility Research Aircraft, the X-45A Unmanned Combat Air Vehicle, and, most recently, the X-48B Blended Wing Body Demonstrator Aircraft. An overview will be presented of the uses of CFD analysis, comparisons and contrasts with wind tunnel testing, and information derived from the CFD analysis that directly related to successful flight test. Some lessons learned on the proper application, and misapplication, of CFD are illustrated. Finally, some highlights of the flight-test results of the three example X-planes will be presented. This overview paper will discuss some of the author s experience with taking an aircraft shape from early concept and three-dimensional modeling through CFD analysis, wind tunnel testing, further refined CFD analysis, and, finally, flight. An overview of the key roles in which CFD plays well during this process, and some other roles in which it does not, are discussed. How wind tunnel testing complements, calibrates, and verifies CFD analysis is also covered. Lessons learned on where CFD results can be misleading are also given. Strengths and weaknesses of the various types of flow solvers, including panel methods, Euler, and Navier-Stokes techniques, are discussed. The paper concludes with the three specific examples, including some flight test video footage of the X-36, the X-45A, and the X-48B.

Cosentino, Gary B.↗

A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.

Wang, Zuwei↗