Search NASA⌕ Search

SEARCH · Search NASA

Results for “alternating current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Unexpected Giant Microwave Conductivity in a Nominally Silent BiFeO 3 Domain Wall

Nanoelectronic devices based on ferroelectric domain walls (DWs), such as memories, transistors, and rectifiers, have been shown in recent years. Practical high-speed electronics, on the other hand, usually demand operation frequencies in the gigahertz (GHz) regime, where the effect of dipolar oscillation is important. Herein, an unexpected giant GHz conductivity on the order of 10 3 S m -1 is observed in certain BiFeO 3 DWs, which is about 100 000 times greater than the carrier-induced direct current (dc) conductivity of the same walls. Surprisingly, the nominal configuration of the DWs precludes the alternating current (ac) conduction under an excitation electric field perpendicular to the surface. Theoretical analysis reflects that the inclined DWs are stressed asymmetrically near the film surface, whereas the vertical walls in a control sample are not. The resultant imbalanced polarization profile can then couple to the out-of-plane microwave fields and induce power dissipation, which is confirmed by the phase-field modeling. Since the contributions from mobile-carrier conduction and bound-charge oscillation to the ac conductivity are equivalent in a microwave circuit, the research on local structural dynamics may open a new avenue to implement DW nano-devices for radio-frequency applications.

36 MATERIALS SCIENCE↗

Power converter circuitry for photovoltaic devices

Power converter circuitry includes a direct current (DC) input comprising a first DC input node and a second DC input node, an alternating current (AC) output comprising a first AC output node coupled to the first DC input node and a second AC output node, a first boost switch coupled between the second DC input node and a boost intermediate node, a second boost switch coupled between the boost intermediate node and a common node, a boost inductor coupled between the boost intermediate node and the first DC input node, a link capacitor coupled between the second DC input node and the common node, a first half-bridge switch coupled between the second DC input node and a half-bridge intermediate node, a second half-bridge switch coupled between the half-bridge intermediate node and the common node, and a half-bridge inductor coupled between the half-bridge intermediate node and the second AC output node.

Ayyanar, Rajapandian↗

Generation of electric-field stabilized zirconium monoxide secondary phase within cubic zirconia

Flash sintering of cubic yttria-stabilized zirconia has been studied via in situ energy dispersive diffraction. A secondary rocksalt-phase zirconium monoxide was observed emerging from the primary fluorite-phase zirconium dioxide, previously only observed as a thin interlayer at metal-oxide interfaces, upon application of a direct current electric field. The average secondary phase intensity rose over extended flow of direct current through the ceramic, faded upon removal of the field and disappeared entirely upon application of an alternating current electric field. The results indicate that the sustained application of a direct current electric field can result in significant electrochemical reduction of zirconia under high current density conditions. Poor sinterability and cracking under direct current is apparent and potential mechanisms discussed therein.

36 MATERIALS SCIENCE↗

Status of Analysis and Manufacturability of Superconducting Wires with Low AC Losses

Superconductors can carry an order-of-magnitude higher current than room temperature copper wires and can do so with two orders-of-magnitude lower alternating current (AC) electrical losses. These advantages underlie our estimates that turboelectric propulsion of large aircraft can be enabled by superconducting machines. However, even the much smaller losses of superconductors pose thermal management issues at the low temperatures required for superconductivity, and predicting those losses and validating the predictions has been a developing process at NASA Glenn Research Center over the last decade. Since Glenn’s earliest assessments of the feasibility of fully superconducting machines for turboelectric propulsion, the available models of AC losses in superconductors have changed significantly, as well as the state of development of superconducting wire for the coils of electric machines. While the models available to us have improved significantly, the value of the AC losses predicted by these models have only increased as more fidelity was developed. The fabrication of medium temperature superconducting wires (Tc near 40 K) has advanced, and wires can be produced with finer filaments and tighter twisting than a decade ago. However, the ideal wire configurations, developed decades ago for low temperature superconductors (Tc < 25 K), still elude manufacturers of medium and high temperature (Tc > 77 K) superconductors. This report discusses the developments, the current limitations, and the expectations that future configurations of superconducting wire can yet be produced that will provide suitably low AC losses for the aircraft propulsion application. The report presents a basic discussion of the types of AC losses in superconductors, followed by a discussion of the evolution of our understanding of the practical consequences of those AC losses. Next, there is a discussion of the superconducting wire configurations that have been developed, which were partially guided by that understanding. A brief discussion of the modes of removing the heat produced by the losses is presented. Lastly, a comparison is presented between losses in currently available MgB2 wire and other important cases, including copper at room temperature, copper at liquid hydrogen temperature, and expected future MgB2 wire. Room temperature copper has 100 times the loss of today’s MgB2 and 300 times the expected loss of future MgB2. That implies we can expect much higher efficiency from fully superconducting machines than from machines with copper stators, and high efficiency targets remain the driver behind investment in MgB2 development and medium temperature superconductor research.

superconducting motors↗

Simulation and power quality analysis of a Loose-Coupled bipolar DC microgrid in an office building

With distributed generation and battery storage technologies thriving in microgrids, the use of direct current (DC) microgrids in the building sector offers multiple advantages in energy efficiency and power quality compared with alternating current (AC) systems. This study developed a new concept of a loose-coupled bipolar DC building power system. In this work, the concept was used to design a real-world office building in Shenzhen, China. A power system model was developed to study the stability and control of the DC power system and to verify DC power quality. The design and modeling of the DC power control system is discussed in detail. The study developed a few common fault scenarios in DC building microgrids that were simulated in the MATLAB-Simulink environment to validate the design of a loose-coupled bipolar DC system. The results indicate that the proposed loose-coupled bipolar DC system schema, when implemented with proper control algorithms, can achieve good fault-tolerant performance with reliable power quality, even during disruptive system events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Condition monitoring of permanent magnet AC machines for all-electric transportation systems: State of the art

The current state of the art on emerging and efficient techniques for condition monitoring of permanent magnet (PM) alternating-current (AC) machines deployed in electric vehicle (EV) applications is presented. The discussion includes the most common and specific types of faults in PM motors, such as rotor demagnetisation and stator inter-turn faults, respectively. Fault indicators, such as voltage (v s ) and current (i s ) signals and machine signatures based on motor back electromotive force (EMF) (E B ) and magnetic flux (φ), are taken into account as a measuring quantity in diagnosing motor faults. Other signatures, including thermal analysis, acoustic noise, and vibrations, are also illustrated as some of the emerging techniques in estimating the performance of EV motors while under operations. In addition, various fault modelling methods, condition monitoring techniques, and comprehensive approaches applied in diagnosing the effect of machine faults during its incipient stages are illustrated. Since most of the fault diagnostic techniques discussed here include only machine-based quantities as fault indices/indicators, the provided solutions are therefore found to be more reliable and accurate for diagnosing the motor faults. This comprehensive review study is inclusive of the existing fault diagnostic techniques, which are currently employed in industrial and commercial practices, in addition to the new methodologies proposed by the authors. All the given condition monitoring schemes therefore seem significantly vital in estimating the state of health of PM AC machines while under operation in all-electric transportation systems.

33 ADVANCED PROPULSION SYSTEMS↗

Techno-economic analysis of DC power distribution in commercial buildings

Improvements in building end-use efficiency have significantly reduced the energy intensity of new buildings, but diminishing returns make it a challenge to build very-low energy buildings cost-effectively. A largely untapped efficiency strategy is to improve the efficiency of power distribution within buildings. Direct current (DC) distribution with modern power electronics has the potential to eliminate much of the power conversion loss in alternating current (AC) building distribution networks that include photovoltaics and DC end uses. Previous literature suggests up to 15% energy savings from DC power distribution in very energy efficient buildings with onsite generation and battery storage. This paper extends prior energy modeling of DC versus AC distribution in buildings, to consider the cost of implementing DC systems on a life-cycle basis. A techno-economic analysis framework based on commercially available products that evaluates the cost-effectiveness of DC systems is presented. The analysis is conducted for three commercial building types in two California climate zones and for various PV and battery storage capacities. Monte Carlo simulation is used to compute the payback period and lifecycle cost savings of DC versus AC distribution systems. A future-market scenario is also examined, which evaluates how future efficiency improvements in power converters and changes in electricity tariffs may affect cost savings. This analysis shows that DC systems can be cost-effective in all scenarios that include large capacities of battery storage and onsite solar, whereas for systems without storage, DC distribution is generally not cost-effective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

Plasma confinement by a picket-fence

It is shown that a current-produced line cusp field in a 'picket fence' configuration will confine both primary ionizing electrons and plasma. The 'picket fence' consists of a planar array of equally spaced water-cooled copper tubing with the current alternating in direction. The loss rates of both plasma and primary electrons are shown to be inversely proportional to the fence current. Plasma confinement is found to be much weaker than electron confinement.

Leung, K. N.↗

Uranium-Loaded Water Treatment Resins: 'Equivalent Feed' at NRC and Agreement State-Licensed Uranium Recovery Facilities - 12094

Community Water Systems (CWSs) are required to remove uranium from drinking water to meet EPA standards. Similarly, mining operations are required to remove uranium from their dewatering discharges to meet permitted surface water discharge limits. Ion exchange (IX) is the primary treatment strategy used by these operations, which loads uranium onto resin beads. Presently, uranium-loaded resin from CWSs and mining operations can be disposed as a waste product or processed by NRC- or Agreement State-licensed uranium recovery facilities if that licensed facility has applied for and received permission to process 'alternate feed'. The disposal of uranium-loaded resin is costly and the cost to amend a uranium recovery license to accept alternate feed can be a strong disincentive to commercial uranium recovery facilities. In response to this issue, the NRC issued a Regulatory Issue Summary (RIS) to clarify the agency's policy that uranium-loaded resin from CWSs and mining operations can be processed by NRC- or Agreement State-licensed uranium recovery facilities without the need for an alternate feed license amendment when these resins are essentially the same, chemically and physically, to resins that licensed uranium recovery facilities currently use (i.e., equivalent feed). NRC staff is clarifying its current alternate feed policy to declare IX resins as equivalent feed. This clarification is necessary to alleviate a regulatory and financial burden on facilities that filter uranium using IX resin, such as CWSs and mine dewatering operations. Disposing of those resins in a licensed facility could be 40 to 50 percent of the total operations and maintenance (O and M) cost for a CWS. Allowing uranium recovery facilities to treat these resins without requiring a license amendment lowers O and M costs and captures a valuable natural resource. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plasma Sanitization of Radish Seeds for International Space Station Growth Experiments

Plant growth in space has long been a topic of key interest to enable sustained human presence. Seeds are common sources for microbial growth and must be sanitized before being sent to space. Current disinfection methods use toxic chemicals that require careful handling and dosing or are ineffective against certain seed types. Low temperature plasma provides an alternative to traditional methods. Plasma produces reactive species and ultraviolet light that reduce contaminants on seeds. NASA’s Kennedy Space Center has explored the treatment of radish seeds with plasma for sanitization and germination. Radio Frequency (RF) and Alternating Current (AC) plasma sources provided continuous treatment of radish seeds in a low-pressure and atmospheric environment, respectively. The seeds were analyzed to compare the presence of bacteria, fungi, and the germination rate. Comparisons between direct and indirect treatments, power supplies, treatment times, and treatment pressures showed the importance of proper dosing of reactive species. Higher powers and longer treatment times have shown larger reductions in microbial contaminants. However, extended direct exposure to high powered plasma can sometimes lead to a reduction in germination rates. Overall, plasma has shown promise as a viable alternative to chemical disinfection techniques. *Work supported by NASA's Kennedy Space Center Engineering and Safety Operations Independent Research and Technology Development.

K W Engeling↗

Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings

An increasing number of energy efficient appliances operate on direct current (DC) internally, offering the potential to use DC from renewable energy systems directly and avoiding the losses inherent in converting power to alternating current (AC) and back. This paper investigates that potential for net-metered residences with on-site photovoltaics (PV) by modeling the net power draw of the ‘direct-DC house’ with respect to today’s typical configuration, assuming identical DC-internal loads. Power draws were modeled for houses in 14 U.S. cities, using hourly, simulated PV-system output and residential loads. The latter were adjusted to reflect a 33% load reduction, representative of the most efficient DC-internal technology, based on an analysis of 32 electricity end-uses. The model tested the effect of climate, electric vehicle (EV) loads, electricity storage, and load shifting on electricity savings; a sensitivity analysis was conducted to determine how future changes in the efficiencies of power system components might affect savings potential. Based on this work, we estimate that net-metered PV residences could save 5% of their total electricity load for houses without storage and 14% for houses with storage. Based on residential PV penetration projections for year 2035 obtained from the National Energy Modeling System (2.7% for the reference case and 11.2% for the extended policy case), direct-DC could save the nation 10 trillion Btu (without storage) or 40 trillion Btu (with storage). Shifting the cooling load by two hours earlier in the day (pre-cooling) has negligible benefits for energy savings. Direct-DC provides no energy savings benefits for EV charging, to the extent that charging occurs at night. However, if charging occurred during the day, for example with employees charging while at work, the benefits would be large. Direct-DC energy savings are sensitive to power system and appliance conversion efficiencies but are not significantly influenced by climate. While direct-DC for residential applications will most likely arise as a spin-off of developments in the commercial sector—because of lower barriers to market entry and larger energy benefits resulting from the higher coincidence between load and insolation—this paper demonstrates that there are substantial benefits in the residential sector as well. Among residential applications, space cooling derives the largest energy savings from being delivered by a direct-DC system. It is the largest load for the average residence on a national basis and is particularly so in high-load regions. It is also the load with highest solar coincidence.

14 SOLAR ENERGY↗

Eddy Current Model of a Coil Over An Infinite Perfectly Electrical Conductor (PEC) Half-Plane

Eddy current sensors measure the lift-off or distance between the sensor and a conducting surface. They operate on the principle of an alternating current in a conduction coil inducing a magnetic field within the surface. An eddy current is set up in the surface to counter the incident magnetic field which, in turn, sets up a magnetic field which counters that of the coil. This changes the coil impedance which is a function of the lift-off. As the lift-off increases, the effect of the eddy current magnetic field on the coil magnetic field weakens, resulting in a higher inductance and lower resistance. Thus, the lift-off may be derived from an impedance measurement. Dodd and Deeds developed an analytic model for an eddy current sensor coil impedance with an air core which has been implemented in MATLAB. LLNL assembled an eddy current sensor with a mu-metal core for which there is no analytic model. Rather than derive an analytic model which includes the mu-metal core, analytic empirically based functions are derived to map the Dodd and Deeds model to measured inductance and resistance.

42 ENGINEERING↗

Investigation of Lunar Regolith Reduction via Hydrogen Plasma in Different Plasma Environments

The team at NASA KSC explored the use of hydrogen plasma as a reducing agent for Lunar regolith simulant in order to prove the viability of oxygen extraction from oxides. The focus of this work was to investigate the hydrogen ion production of different plasma power sources. An optimization trade study was completed by maximizing the production of the hydrogen ion and comparing the amount produced to the energy consumed. Hydrogen ion production was determined via residual gas analysis and a rough calibration using injected water. The hydrogen ions reduce the oxides present in the Lunar regolith, forming an OH molecule, which can further react with the hydrogen environment to form water vapor. This water vapor can then be measured through a residual gas analysis. Through this study, it was found that a direct current (DC) glow discharge operating at approximately 1 torr in a hydrogen environment produced the largest amount of reduced regolith when compared with a nanosecond pulsed system and alternating current (AC) source. Radiofrequency devices beyond AC were not studied in this work. Although the DC source performed the best here, limitations in design and experiment setup/scalability may lead to the selection of an alternative plasma power source in the future.

Kenneth Engeling↗

Interface-driven spin-torque ferromagnetic resonance by Rashba coupling at the interface between nonmagnetic materials

The Rashba-Edelstein effect stems from the interaction between the electron's spin and its momentum induced by spin-orbit interaction at an interface or a surface. It was shown that the inverse Rashba-Edelstein effect can be used to convert a spin current into a charge current. Here, we demonstrate the reverse process of a charge-to spin-current conversion at a Bi/Ag Rashba interface. We show that this interface-driven spin current can drive an adjacent ferromagnet to resonance. We employ a spin-torque ferromagnetic resonance excitation/detection scheme which was developed originally for a bulk spin-orbital effect, the spin Hall effect. In our experiment, the direct Rashba-Edelstein effect generates an oscillating spin current from an alternating charge current driving the magnetization precession in a neighboring permalloy (Py, Ni 80 Fe 20 ) layer. As a result, electrical detection of the magnetization dynamics is achieved by a rectificationmechanism of the time dependent multilayer resistance arising from the anisotropic magnetoresistance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrical properties of sample 70215 - Low-frequency corrections

Dielectric permittivity, loss tangent, and direct current conductivity of solid sample 70215,14 were measured at temperatures ranging from 100 to 373 K and vacuums of .01 to .1 microtorr; alternating current measurements were made in the 30 Hz to 100 kHz frequency range. It is concluded that dc conductivity undergoes a three order-of-magnitude change between lunar day and lunar night. The assumption is made that strong k' increments at the lower frequencies are partially induced by electrode and dc conductivity effects. Corrections were applied to the experimental data; corrected results suggest relaxation processes occurring at frequencies below 1 kHz.

Alvarez, R.↗

Exploring the Promotion of Synthons of Choice: Halogen Bonding in Molecular Lanthanide Complexes Characterized via X-ray Diffraction, Luminescence Spectroscopy, and Magnetic Measurements

Promotion of a synthon of choice for the non-covalent assembly of lanthanide tectons represents both a noteworthy challenge and opportunity within Ln(III) hybrid materials. We have developed a system wherein some control can be exercised over supramolecular assembly and, as part of continued efforts to improve this process we have generated a family of ten new lanthanide (Ln = Sm 3+ -Lu 3+ )-2,4,6-trichlorobenzoic acid-1,10- phenanthroline molecular complexes. Delineation of criteria for promoting assembly via halogen based interactions was introduced previously and is refined herein based on the characterization of complexes 1-10 via single crystal X-ray diffraction. Direct comparison of means of supramolecular assembly for 1-10 with isostructural Ln-pchlorobenzoic acid-1,10-phenathroline analogues verifies that increasing the number of halogens at the periphery of a tecton is one route that increases the frequency of halogen bonding interactions. Additionally, solid-state visible and near-IR photoluminescence and luminescent lifetime data were collected for complexes 1 (Sm 3+ ), 2 (Eu 3+ ), 4 (Tb 3+ ), 5 (Dy 3+ ), 6 (Ho 3+ ), 7 (Er 3+ ), and 9 (Yb 3+ ) and characteristic emission was observed for all complexes except 6. Further, direct current magnetic susceptibility measurements were carried out for complexes 5 (Dy 3+ ) and 7 (Er 3+ ), and two slow magnetic relaxation processes were characterized using alternating current magnetic susceptibility measurements for 5.

36 MATERIALS SCIENCE↗

Comparative Study of DC and AC Microgrids in Commercial Buildings Across Different Climates and Operating Profiles

Bosch has developed and demonstrated a novel direct current (DC) microgrid system that maximizes the efficiency of locally generated photovoltaic energy while offering high reliability, safety, redundancy, and reduced cost compared to equivalent alternating current (AC) systems. Several demonstration projects validating the system feasibility and expected efficiency gains have been completed and additional ones are in progress. This paper gives an overview of the Bosch DC microgrid system and presents key results from a large simulation study done to estimate the energy savings of the Bosch DC microgrid over conventional AC systems. The study examined the system performance in locations across the United States for several commercial building types and operating profiles. It found that the Bosch DC microgrid uses generated PV energy 6%-8% more efficiently than traditional AC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗