Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Analysis techniques for the evaluation of the neutrinoless double- β decay lifetime in Te 130 with the CUORE-0 detector

We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ( 0 ν β β ) decay in 130 Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques developed for CUORE, a next-generation experiment scheduled to come online in 2016. CUORE-0 is also a competitive 0 ν β β decay search in its own right and functions as a platform to further develop the analysis tools and procedures to be used in CUORE. These include data collection, event selection and processing, as well as an evaluation of signal efficiency. In particular, we describe the amplitude evaluation, thermal gain stabilization, energy calibration methods, and the analysis event selection used to create our final 0 ν β β search spectrum. We define our high level analysis procedures, with emphasis on the new insights gained and challenges encountered. We outline in detail our fitting methods near the hypothesized 0 ν β β decay peak and catalog the main sources of systematic uncertainty. Finally, we derive the 0 ν β β decay half-life limits previously reported for CUORE-0, T 0 ν 1 / 2 > 2.7 × 10 24 yr , and in combination with the Cuoricino limit, T 0 ν 1 / 2 > 4.0 × 10 24 yr .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiation-induced refraction artifacts in the optical CT readout of polymer gel dosimeters

Purpose: The objective of this work is to demonstrate imaging artifacts that can occur during the optical computed tomography (CT) scanning of polymer gel dosimeters due to radiation-induced refractive index (RI) changes in polyacrylamide gels. Methods: A 1 L cylindrical polyacrylamide gel dosimeter was irradiated with 3 × 3 cm{sup 2} square beams of 6 MV photons. A prototype fan-beam optical CT scanner was used to image the dosimeter. Investigative optical CT scans were performed to examine two types of rayline bending: (i) bending within the plane of the fan-beam and (ii) bending out the plane of the fan-beam. To address structured errors, an iterative Savitzky–Golay (ISG) filtering routine was designed to filter 2D projections in sinogram space. For comparison, 2D projections were alternatively filtered using an adaptive-mean (AM) filter. Results: In-plane rayline bending was most notably observed in optical CT projections where rays of the fan-beam confronted a sustained dose gradient that was perpendicular to their trajectory but within the fan-beam plane. These errors caused distinct streaking artifacts in image reconstructions due to the refraction of higher intensity rays toward more opaque regions of the dosimeter. Out-of-plane rayline bending was observed in slices of the dosimeter that featured dose gradients perpendicular to the plane of the fan-beam. These errors caused widespread, severe overestimations of dose in image reconstructions due to the higher-than-actual opacity that is perceived by the scanner when light is bent off of the detector array. The ISG filtering routine outperformed AM filtering for both in-plane and out-of-plane rayline errors caused by radiation-induced RI changes. For in-plane rayline errors, streaks in an irradiated region (>7 Gy) were as high as 49% for unfiltered data, 14% for AM, and 6% for ISG. For out-of-plane rayline errors, overestimations of dose in a low-dose region (∼50 cGy) were as high as 13 Gy for unfiltered data, 10 Gy for AM, and 3.1 Gy for ISG. The ISG routine also addressed unrelated artifacts that previously needed to be manually removed in sinogram space. However, the ISG routine blurred reconstructions, causing losses in spatial resolution of ∼5 mm in the plane of the fan-beam and ∼8 mm perpendicular to the fan-beam. Conclusions: This paper reveals a new category of imaging artifacts that can affect the optical CT readout of polyacrylamide gel dosimeters. Investigative scans show that radiation-induced RI changes can cause significant rayline errors when rays confront a prolonged dose gradient that runs perpendicular to their trajectory. In fan-beam optical CT, these errors manifested in two ways: (1) distinct streaking artifacts caused by in-plane rayline bending and (2) severe overestimations of opacity caused by rays bending out of the fan-beam plane and missing the detector array. Although the ISG filtering routine mitigated these errors better than an adaptive-mean filtering routine, it caused unacceptable losses in spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron Area X-ray Detectors, Present and Future

X-ray experiments are very frequently detector limited at today's storage ring synchrotron radiation (SR) sources, and will be even more so at future Energy Recovery Linac and X-ray Free Electron Laser sources. Image plate and phosphor-coupled CCD detectors that predominate at present-day sources were outgrowths of technologies initially developed for the medical and astronomical communities, respectively, with resultant limitations for SR. These limitations are enumerated. The growth of commercial silicon foundries and design tools enabling the production of large, customized integrated circuits is beginning to have a profound impact on SR detectors and is ushering in the age of 'designer detectors'. Novel area Pixel Array Detectors (PADs) are starting to appear in which each pixel has dedicated, complex circuitry capable of high speed and, in some cases, significant data processing power for specific applications. PADs now at, or near the horizon will be described. Integrated circuit methods continue to develop at a rapid pace. Implications for future x-ray detectors will be discussed.

43 PARTICLE ACCELERATORS↗

Recent experimental results of two-proton correlated emission from the excited states of {sup 17,18}Ne and {sup 28,29}S

Two-proton emissions from the excited states of {sup 17,18}Ne and {sup 28,29}S were investigated by the radioactive beams bombarding on the {sup 197}Au target via the Coulomb excitation. The complete-kinematics measurements were actualized by the stacks of silicon-strip detectors and CsI+PIN array detectors. The invariant mass of final systems as well as the relative momentum, opening angle, and relative energy of the two emitted protons were reconstructed under the framework of relativistic kinematics. The mechanisms of two-proton emission were analyzed in a simple schematic model. With the help of Monte-Carlo simulations, the two protons emitted from the 6.15 MeV excited state of {sup 18}Ne and the excited states around 10 MeV of {sup 29}S, respectively, exhibit prominent features of {sup 2}He decay. While for the other states, no obvious diproton emissions were observed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated photonic Galton board and its application for photon counting

The Galton board is a desktop probability machine traditionally used to visualize the principles of statistical physics from classical particles. Here, we demonstrate a photonic Galton board that enables on-chip observation of statistics from single-photon interference. The photonic Galton board consists of a directional coupler matrix terminated by an array of superconducting nanowire detectors to provide spatiotemporal resolution. This design also allows for photon-number-resolving capability, making it suitable for high-speed photon counting. Our results demonstrate the compatibility between single-photon detector array and photonic integrated circuits, paving the way for implementing on-chip large-scale quantum optics experiments and photonic quantum computing.

Qin, Hezheng (ORCID:0009000139348800)↗

Deformations and magnetic rotations in the {sup 60}Ni nucleus

Data from three experiments using the heavy-ion fusion evaporation-reaction {sup 36}Ar+{sup 28}Si have been combined to study high-spin states in the residual nucleus {sup 60}Ni, which is populated via the evaporation of four protons from the compound nucleus {sup 64}Ge. The GAMMASPHERE array was used for all the experiments in conjunction with a 4{pi} charged-particle detector arrays (MICROBALL, LUWUSIA) and neutron detectors (NEUTRON SHELL) to allow for the detection of {gamma} rays in coincidence with the evaporated particles. An extended {sup 60}Ni level scheme is presented, comprising more than 270{gamma}-ray transitions and 110 excited states. Their spins and parities have been assigned via directional correlations of {gamma} rays emitted from oriented states. Spherical shell-model calculations in the fp-shell characterize some of the low-spin states, while the experimental results of the rotational bands are analyzed with configuration-dependent cranked Nilsson-Strutinsky calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Searching for axion dark matter with array-scalable single magnon detectors

We introduce an array-scalable, magnon-based detector to search for the spin-dependent interactions of electron-coupled axion dark matter with mass in the 1−100 μ⁢eV range. These axions can excite single magnons in magnetic targets, such as yttrium iron garnet (YIG) spheres, which are subsequently sensed by the detector. In our concept, this sensing is implemented by coupling the magnons in the YIG spheres to magnetic-field-resilient single-electron charge-qubits, whose state is then interrogated with a quantum nondemolition measurement. Using standard superconducting fabrication techniques, it is possible to integrate many YIG sphere-qubit sensors, forming a large detector array. We outline the detector design and operation for our concept, and determine its sensitivity to axion dark matter. We find that using available technology can already exceed the sensitivity of previous ferromagnetic haloscopes, and further improvements in performance would search for electron-coupled axion dark matter in unexplored parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic-ray anisotropies in right ascension measured by the Pierre Auger Observatory

We present measurements of the large-scale cosmic-ray anisotropies in right ascension, using data collected by the surface detector array of the Pierre Auger Observatory over more than 14 years. We determine the equatorial dipole component, $\vec{d}_\perp$, through a Fourier analysis in right ascension that includes weights for each event so as to account for the main detector-induced systematic effects. For the energies at which the trigger efficiency of the array is small, the ``East-West'' method is employed. Besides using the data from the array with detectors separated by 1500 m, we also include data from the smaller but denser sub-array of detectors with 750 m separation, which allows us to extend the analysis down to $\sim 0.03$ EeV. The most significant equatorial dipole amplitude obtained is that in the cumulative bin above 8~EeV, $d_\perp=6.0^{+1.0}_{-0.9}$%, which is inconsistent with isotropy at the 6$\sigma$ level. In the bins below 8 EeV, we obtain 99% CL upper-bounds on $d_\perp$ at the level of 1 to 3 percent. At energies below 1 EeV, even though the amplitudes are not significant, the phases determined in most of the bins are not far from the right ascension of the Galactic center, at $\alpha_{\rm GC}=-94^\circ$, suggesting a predominantly Galactic origin for anisotropies at these energies. The reconstructed dipole phases in the energy bins above 4 EeV point instead to right ascensions that are almost opposite to the Galactic center one, indicative of an extragalactic cosmic ray origin.

79 ASTRONOMY AND ASTROPHYSICS↗

Compendium of Instrumentation Whitepapers on Frontier Physics Needs for Snowmass 2013

Contents of collection of whitepapers include: Operation of Collider Experiments at High Luminosity; Level 1 Track Triggers at HL-LHC; Tracking and Vertex Detectors for a Muon Collider; Triggers for hadron colliders at the energy frontier; ATLAS Upgrade Instrumentation; Instrumentation for the Energy Frontier; Particle Flow Calorimetry for CMS; Noble Liquid Calorimeters; Hadronic dual-readout calorimetry for high energy colliders; Another Detector for the International Linear Collider; e+e- Linear Colliders Detector Requirements and Limitations; Electromagnetic Calorimetry in Project X Experiments The Project X Physics Study; Intensity Frontier Instrumentation; Project X Physics Study Calorimetry Report; Project X Physics Study Tracking Report; The LHCb Upgrade; Neutrino Detectors Working Group Summary; Advanced Water Cherenkov R&D for WATCHMAN; Liquid Argon Time Projection Chamber (LArTPC); Liquid Scintillator Instrumentation for Physics Frontiers; A readout architecture for 100,000 pixel Microwave Kinetic In- ductance Detector array; Instrumentation for New Measurements of the Cosmic Microwave Background polarization; Future Atmospheric and Water Cherenkov ?-ray Detectors; Dark Energy; Can Columnar Recombination Provide Directional Sensitivity in WIMP Search?; Instrumentation Needs for Detection of Ultra-high Energy Neu- trinos; Low Background Materials for Direct Detection of Dark Matter; Physics Motivation for WIMP Dark Matter Directional Detection; Solid Xenon R&D at Fermilab; Ultra High Energy Neutrinos; Instrumentation Frontier: Direct Detection of WIMPs; nEXO detector R&D; Large Arrays of Air Cherenkov Detectors; and Applications of Laser Interferometry in Fundamental Physics Experiments.

Lipton, R.↗

Multi-energy x-ray imaging and sensing for diagnostic and control of the burning plasma

New diagnostic and sensor designs are needed for future burning plasma (BP) fusion experiments, having good space and time resolution and capable of prolonged operation in the harsh BP environment. We evaluate the potential of multi-energy x-ray imaging with filtered detector arrays for BP diagnostic and control. Experimental studies show that this simple and robust technique enables measuring with good accuracy, speed, and spatial resolution the T{sub e} profile, impurity content, and MHD activity in a tokamak. Applied to the BP this diagnostic could also serve for non-magnetic sensing of the plasma position, centroid, ELM, and RWM instability. BP compatible x-ray sensors are proposed using 'optical array' or 'bi-cell' detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A gas jet target for radioactive ion beam experiments

New radioactive ion beam (RIB) facilities, like FRIB in the US or FAIR in Europe, will push further away from stability and enable the next generation of nuclear physics experiments. Thus, the need for improved RIB targets is more crucial than ever: developments in exotic beams should coincide with developments in targets for use with those beams, in order for nuclear physics to remain on the cutting edge. Of great importance to the future of RIB physics are scattering, transfer and capture reaction measurements of rare, exotic, and unstable nuclei on light targets such as hydrogen and helium. These measurements require targets that are dense, highly localized, and pure, and conventional targets often suffer too many drawbacks to allow for such experimental designs. Targets must also accommodate the use of large area, highly-segmented silicon detector arrays, high-efficiency gamma arrays, and novel heavy ion detectors to efficiently measure the reaction products. To address this issue, the Jet Experiments in Nuclear Structure and Astrophysics (JENSA) Collaboration led by the Colorado School of Mines (CSM) is in the process of designing, building and testing a supersonic gas jet target for use at existing and future RIB facilities. The gas jet target provides a high density and high purity of target nuclei within a tightly confined region, without the use of windows or backing materials. The design also enables the use of multiple state-of-the-art detection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of LUMINEU program to search for neutrinoless double beta decay of {sup 100}Mo with cryogenic ZnMoO{sub 4} scintillating bolometers

The LUMTNEU program aims at performing a pilot experiment on 0ν2β decay of {sup 100}Mo using radiopure ZnMoO{sub 4} crystals enriched in {sup 100}Mo operated as cryogenic scintillating bolometers. Large volume ZnMoO{sub 4} crystal scintillators (∼ 0.3 kg) were developed and tested showing high performance in terms of radiopurity, energy resolution and α/β particle discrimination capability. Zinc molybdate crystal scintillators enriched in {sup 100}Mo were grown for the first time by the low-thermal-gradient Czochralski technique with a high crystal yield and an acceptable level of enriched molybdenum irrecoverable losses. A background level of ∼ 0.5 counts/(yr keV ton) in the region of interest can be reached in a large detector array thanks to the excellent detectors radiopurity and particle discrimination capability, suppression of randomly coinciding events by pulse-shape analysis, and anticoincidence cut. These results pave the way to future sensitive searches based on the LUMTNEU technology, capable of approachingand exploring the inverted hierarchy region of the neutrino mass pattern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BAYESIAN ANGULAR POWER SPECTRUM ANALYSIS OF INTERFEROMETRIC DATA

We present a Bayesian angular power spectrum and signal map inference engine which can be adapted to interferometric observations of anisotropies in the cosmic microwave background (CMB), 21 cm emission line mapping of galactic brightness fluctuations, or 21 cm absorption line mapping of neutral hydrogen in the dark ages. The method uses Gibbs sampling to generate a sampled representation of the angular power spectrum posterior and the posterior of signal maps given a set of measured visibilities in the uv-plane. We use a mock interferometric CMB observation to demonstrate the validity of this method in the flat-sky approximation when adapted to take into account arbitrary coverage of the uv-plane, mode-mode correlations due to observations on a finite patch, and heteroschedastic visibility errors. The computational requirements scale as O(n{sub p} log n{sub p}) where n{sub p} measures the ratio of the size of the detector array to the inter-detector spacing, meaning that Gibbs sampling is a promising technique for meeting the data analysis requirements of future cosmology missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Results of the MAJORANA DEMONSTRATOR’s Search for Double-Beta Decay of 76 Ge to Excited States of 76 Se

The MAJORANA DEMONSTRATOR is searching for double-beta decay of 76 Ge to excited states (E.S.) in 76Se using a modular array of high purity Germanium detectors. 76 Ge can decay into three E.S.s of 76 Se. The E.S. decays have a clear event signature consisting of a ββ-decay with the prompt emission of one or two γ-rays, resulting in with high probability in a multi-site event. The granularity of the DEMONSTRATOR detector array enables powerful discrimination of this event signature from backgrounds. Using 21.3 kg-y of isotopic exposure, the DEMONSTRATOR has set world leading limits for each E.S. decay, with 90% CL lower half-life limits in the range of (0.56 – 2.1) • 10 24 y. In particular, for the 2v transition to the first 0 + E.S. of 76 Se, a lower half-life limit of 0.68 • 10 24 at 90% CL was achieved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗