Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Telstar 401 Reconditioning Experience

Telstar 401 was launched December 15, 1993. It has two 58 cell 50 AH Nickel Hydrogen batteries of the Comsat design. Reconditioning has traditionally been used as a means of maintaining the performance of normal cells and batteries. This paper describes a situation in which reconditioning was used to improve the performance of nickel-hydrogen batteries in Telstar 40. Reconditioning is carried out with relay selected resistors across the entire battery for rates of approximately C/50 and C/100. There are individual cell voltage monitors and the discharge is carried out until the first cell reaches 0.8 volts.

Maurer, Dean W.↗

Utilization of Machine Learning Techniques for Managing the Tracking and Data Relay Satellite Constellation

National Aeronautics and Space Administration’s (NASA) Goddard Space Flight Center (GSFC) operates a constellation of ten geosynchronous Tracking and Data Relay Satellites (TDRS). The TDRS constellation consists of multiple geosynchronous communication relay satellites located around the equator so they can provide continual coverage of any mission in low earth orbit. The TDRS are located primarily in three oceanic regions around the earth. NASA’s White Sands Complex provides the ground communication support for TDRS located over the Atlantic and Pacific Oceans. Another TDRS ground station in Guam supports the TDRS over the Indian Ocean. With these satellites the TDRS network can provide continuous coverage of satellites in low-earth orbit. The NASA Space Network (SN) project office at GSFC manages the constellation of spacecraft. Major customers of the TDRS constellation include, but are not limited to, the International Space Station and the Hubble Space Telescope. The TDRS constellation has three generations of satellites and has been active for over 30 years providing reliable communication links between customer satellites and corresponding ground stations. However, one of the major concerns for TDRS, and in any space mission, is to ensure the health and safety of the spacecraft. Generally, engineers use telemetry data to monitor and analyze the performance and state of health of the spacecraft. Telemetry data contains hundreds of parameters that monitor each important component in the spacecraft, which can be utilized to recognize and characterize the behavior of the spacecraft. Each parameter contains considerable information to represent time-dependent properties of each spacecraft subsystem and component. During the entire life of a TDRS spacecraft, thousands of gigabytes of telemetry data are transmitted in real-time from the spacecraft to the ground station at the White Sands Complex in Las Cruces, New Mexico, and recorded as historical data sets for engineers to process and analyze the events that occurred on-orbit. These parameters contain the function of multiple spacecraft subsystems, such as the attitude control system (ACS), Thermal, Electrical Power Subsystem (EPS), etc. . The first and second generations have exceeded their required lifetime and NASA is keen to manage these spacecrafts carefully in order to maximize the remaining life using the spacecraft telemetry. The challenge is to know when the risk of losing a spacecraft in geosynchronous orbit exceeds the benefit of continued operations for customer support. In the TDRS fleet, the EPS is the most critical subsystem related to spacecraft operations. Failure of the EPS would strand a spacecraft in geosynchronous orbit. Since EPS provides power to the spacecraft, component failures ultimately lead to the inability to support the spacecraft loads and the communications payload. For instance, TDRS-8 has several anomalies in EPS including the Bus Voltage Limiter (BVL) shunt current, solar array loss of circuits, and failed battery cells. Any of these anomalies can cause critical issues to the spacecraft. Therefore, developing a system to analyze and perform early detection of a potential anomaly is an important issue in telemetry data analysis. In recent years, Telemetry Mining (TM) has been proposed to process telemetry data by using Data Mining (DM) techniques such as classification, clustering, regression and anomaly detection. Anomaly detection, also known as outlier detection, has been widely used in many data mining areas such as remote sensing, medical data processing and digital image processing. The goal of anomaly detection is to detect abnormal data, which contains a relatively low probability of occurrence among the entire data set. Early detection of anomalies is one of the most significant issues in managing the spacecraft configuration. If anomalies can be detected early enough, then the redundant resources can be used to extend the life of the operational spacecraft. We present an unsupervised anomaly detection method to process the EPS data extracted from TDRS-8. This is different from traditional analytical methods, which use telemetry data to illustrate behavior and physical meaning of each spacecraft component. TM connects multiple parameters as a vector and then conducts data analysis on this high dimension telemetry vector. This method is looking at the properties of a high dimensional vector that is able to consider the relationship between different parameters in the anomaly detection problem. This kind of method performs much better than the traditional limit checking method. In addition, we propose a new approach of real-time anomaly detection to process telemetry data in real-time, which can then be applied to spacecraft monitoring with high reliability, low cost and high accuracy.

Machine Learning (ML)↗

Design description of the Schuchuli Village photovoltaic power system

A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV array, 2380 ampere-hours of battery storage, an electrical equipment building, a 120 V (d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, a sewing machine, and lights for each of the homes and communal buildings. A solar hot water heater supplies hot water for the washing machine and communal laundry. Automatic control systems provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority at the expense of low priority loads as the main battery becomes depleted.

Ratajczak, A. F.↗

A Battery Charger and State of Charge Indicator

A battery charger which has a full wave rectifier in series with a transformer isolated 20 kHz dc-dc converter with high frequency switches, which are programmed to actively shape the input dc line current to be a mirror image of the ac line voltage is discussed. The power circuit operates at 2 kW peak and 1 kW average power. The BC/SCI has two major subsystems: (1) the battery charger power electronics with its controls; and (2) a microcomputer subsystem which is used to acquire battery terminal data and exercise the state of charge software programs. The state of charge definition employed is the energy remaining in the battery when extracted at a 10 kW rate divided by the energy capacity of a fully charged new battery. The battery charger circuit is an isolated boost converter operating at an internal frequency of 20 kHz. The switches selected for the battery charger are the single most important item in determining its efficiency. The combination of voltage and current requirements dictate the use of high power NPN Darlington switching transistors. The power circuit topology is a three switch design which utilizes a power FET on the center tap of the isolation transformer and the power Darlingtons on each of the two ends. An analog control system is employed to accomplish active input current waveshaping as well as the necessary regulation.

Latos, T. S.↗

Design of the High Energy Astronomy Observatory /HEAO/ power subsystem

Observatory power is generated by a partially deployable solar array which is modularized to facilitate adaptation to three missions having different power requirements. Three nickel-cadmium batteries are controlled independently from dedicated modular chargers to increase subsystem adaptability and decrease sensitivity to temperature differences between batteries. Battery level redundancy is employed, enabling mission completion with two of three battery/charger combinations operational. Bus voltage limiting is accomplished by a modularized shunt regulator which can survive any single part failure and meet all mission requirements. Relatively low shunt electronics power dissipation internal to the observatory is achieved by sequenced operation of linear shunt segments which are coupled to a large area resistive shunt radiator. Summaries of solar array, battery and subsystem breadboard test results are provided.

Reppucci, G. M.↗

Li-Ion Battery and Supercapacitor Hybrid Design for Long Extravehicular Activities

With the need for long periods of extravehicular activities (EVAs) on the Moon or Mars or a near-asteroid, the need for long-performance batteries has increased significantly. The energy requirements for the EVA suit, as well as surface systems such as rovers, have increased significantly due to the number of applications they need to power at the same time. However, even with the best state-of-the-art Li-ion batteries, it is not possible to power the suit or the rovers for the extended period of performance. Carrying a charging system along with the batteries makes it cumbersome and requires a self-contained power source for the charging system that is usually not possible. An innovative method to charge and use the Li-ion batteries for long periods seems to be necessary and hence, with the advent of the Li-ion supercapacitors, a method has been developed to extend the performance period of the Li-ion power system for future exploration applications. The Li-ion supercapacitors have a working voltage range of 3.8 to 2.5 V, and are different from a traditional supercapacitor that typically has a working voltage of 1 V. The innovation is to use this Li-ion supercapacitor to charge Liion battery systems on an as-needed basis. The supercapacitors are charged using solar arrays and have battery systems of low capacity in parallel to be able to charge any one battery system while they provide power to the application. Supercapacitors can safely take up fast charge since the electrochemical process involved is still based on charge separation rather than the intercalation process seen in Li-ion batteries, thus preventing lithium metal deposition on the anodes. The lack of intercalation and eliminating wear of the supercapacitors allows for them to be charged and discharged safely for a few tens of thousands of cycles. The Li-ion supercapacitors can be charged from the solar cells during the day during an extended EVA. The Liion battery used can be half the capacity required for a nominal EVA. The small Li-ion battery can be divided into two parallel modules with independent charging ports that would allow the supercapacitors to charge one battery while the other is providing power to the rover or suit.

Jeevarajan, Judith↗

Performance Comparison Between NiH2 Dry Sinter and Slurry Electrode Cells

The electrical and thermal performance of dry sinter and slurry process electrode cells manufactured for the Hubble Space Telescope (HST) batteries have been characterized for a matrix of operating conditions over the temperature range from 14 to 86 F at various charge control levels. The dry sinter process electrode cells tested are similar to the onboard HST NiH2 cells. The slurry process electrode cells were developed to be less susceptible to electrode expansion and impedance changes with life. Both cell types were impregnated by the aqueous electrochemical process. Test conditions included standard capacity tests and electrical cycling using 96-minute cycling regimens incorporating gr depth-of-discharge (DOD) cycles. The dry sinter process electrodes have higher operating capacities to 1.20V/cell, but both electrode types have similar heat dissipation for the conditions tested. The results of the testing included cyclic heat generation during a typical 96-minute cycle, operating capacity data vs. cutoff voltage to generate a temperature-compensated voltage curve, and voltage characteristics suitable to develop a voltage prediction model. Analysis of data shows differences in the discharge voltage plateaus operating conditions evaluated. This is the basis for recommended changes in the battery charge control.

Armantrout, J. D.↗

Cell-level battery charge/discharge protection system

The paper describes three design approaches to individual cell monitoring and control for sealed secondary battery cells. One technique involves a modular strap-on single cell protector which contains all the electronics required for monitoring cell voltage, responding to external commands, and forming a bypass circuit for the cell. A second technique, the multiplexed cell protector, uses common circuitry to monitor and control each cell in a battery pack. The third technique, the computerized cell protector, by replacing the hard-wired logic of the multiplexed cell protector with a microprocessor, achieves greatest control flexibility and inherent computational capability with a minimum parts count implementation.

Donovan, R. L.↗

Nickel-cadium batteries for Apollo telescope mount

The operational testing and evaluation program is presented which was conducted on 20-ampere-hour nickel-cadmium (Ni-Cd) batteries for use on the Apollo telescope mount (ATM). The test program was initiated in 1967 to determine if the batteries could meet ATM mission requirements and to determine operating characteristics and methods. The ATM system power and charging power for the Ni-Cd secondary batteries is provided by a solar array during the 58-minute daylight portion of the orbit; during the 36-minute night portion of the orbit, the Ni-Cd secondary batteries will supply ATM system power. The test results reflect battery operating characteristics and parameters relative to simulated ATM orbital test conditions. Maximum voltage, charge requirements, capacity, temperature, and cyclic characteristics are presented.

Kirsch, W. W.↗

Performance of a 14.9-kW laminated-frame dc series motor with chopper controller

Traction motor using two types of excitation: ripple free dc from a motor generator set for baseline data and chopped dc as supplied by a battery and chopper controller was tested. For the same average values of input voltage and current, the power output was independent of the type of excitation. At the same speeds, motor efficiency at low power output (corresponding to low duty cycle of the controller) was 5 to 10 percentage points less on chopped dc than on ripple-free dc. This illustrates that for chopped waveforms, it is incorrect to calculate input power as the product of average voltage and average current. Locked-rotor torque, no load losses, and magnetic saturation data were so determined.

Schwab, J. R.↗

Lightweight Regulated Power Supply

Power-supply circuit regulates output voltage by adjusting frequency of chopper circuit according to variations. Currently installed in battery charger for electric wheelchair, circuit is well suited to other uses in which light weight is important - for example, in portable computers, radios, and test instruments.

Mclyman, C. W.↗

Nickel hydrogen bipolar battery electrode design

The preferred approach of the NASA development effort in nickel hydrogen battery design utilizes a bipolar plate stacking arrangement to obtain the required voltage-capacity configuration. In a bipolar stack, component designs must take into account not only the typical design considerations such as voltage, capacity and gas management, but also conductivity to the bipolar (i.e., intercell) plate. The nickel and hydrogen electrode development specifically relevant to bipolar cell operation is discussed. Nickel oxide electrodes, having variable type grids and in thicknesses up to .085 inch are being fabricated and characterized to provide a data base. A selection will be made based upon a system level tradeoff. Negative (hydrpogen) electrodes are being screened to select a high performance electrode which can function as a bipolar electrode. Present nickel hydrogen negative electrodes are not capable of conducting current through their cross-section. An electrode was tested which exhibits low charge and discharge polarization voltages and at the same time is conductive. Test data is presented.

Puglisi, V. J.↗

Charging/Safety-Interlock Connection For Capacitor Bank

Electrically controlled mechanical interlock apparatus prevents connection of bank of capacitors to battery or other dc power supply until capacitors precharged to nearly full supply voltage. Precharge eliminates excessive inrush current, which damages capacitors, wires, or connectors. Circuit in apparatus also discharges capacitors after power turned off or capacitors disconnected from power supply.

Rippel, Wally E.↗

Nickel-Hydrogen Cell Testing Experience, NASA/Goddard Space Flight Center

The objectives of the project were to test the Nickel-Hydrogen Cell to: (1) verify the Aerospace Cell Flight Worthiness, (2) Elucidate the Aerospace Cell Thermal Behavior, (3) Develop the Aerospace Battery Assembly Design(s) and In-orbit Battery Management plan(s) and (4) Understand the Aerospace Cell Failure Mechanism. The tests included the LEO and GEO Life cycle tests, Calorimetric Analysis, Destructive Physical analysis, and special tests. Charts show the Mission Profile Cycling Data, Stress Cycling Data. The test data complies with the mission requirements, validating the flight worthiness of batteries. The nominal stress and mission profile cycling performance test shows the charge voltage as high as 1.60V and recharge ratio greater than 1.05. It is apparent that the electrochemical signatures alone do not provide conclusive proof for Nickel precharge. The researchers recommend a gas and positive plate analyses for further confirmation.

Rao, Gopalakrishna M.↗

Performance and Safety of Lithium Ion Cells

This report evaluates the performance and safety of Lithium Ion (Li-Ion) cells when used in batteries. Issues discussed include the cycle life, energy efficiency, tolerance to higher charge voltage, tolerance to extended tapered charge voltage, charge on cycling, specific energy, low temperature discharge, low temperature charge, various charge characteristics, storage characteristics, and more of Li-Ion cells.

Ratnakumar, B. V.↗

Method for Predicting the Energy Characteristics of Li-Ion Cells Designed for High Specific Energy

Novel electrode materials with increased specific capacity and voltage performance are critical to the NASA goals for developing Li-ion batteries with increased specific energy and energy density. Although performance metrics of the individual electrodes are critically important, a fundamental understanding of the interactions of electrodes in a full cell is essential to achieving the desired performance, and for establishing meaningful goals for electrode performance in the first place. This paper presents design considerations for matching positive and negative electrodes in a viable design. Methods for predicting cell-level performance, based on laboratory data for individual electrodes, are presented and discussed.

Bennett, William, R.↗

Development of Solid State Electrolytes for Li-Metal Based High Capacity Battery

NASA future missions demand safe, high specific energy (>400 Wh/kg) batteries. Current state-of-the-art (SOA) lithium-ion batteries (LIBs) can only provide ~150-200 Wh/kg in energy capacity, which is unable to meet NASA's future energy goals, and also pose safety issues due to the use of liquid flammable electrolyte. There are intense on-going development activities to increase battery energy density. The use of Li metal as an anode material has emerged as one highly attractive option for achieving high-energy, next generation batteries. This is because Li has many advantages. It is the lightest metal, but also has the highest theoretical capacity. It also has the lowest potential, which boosts whole cell voltage, and Li metal is 100% active material and requires no binder. Thus, Li metal is an ideal anode material for high energy battery chemistries. Lithium metal based advanced battery chemistries are envisioned to be mission enhancing and, in many cases, mission enabling for future space and aeronautic applications. However, the reliable use of this exceptionally high capacity anode in a commercial rechargeable battery has not been achieved due to safety and reliability concerns resulting from thermal runaway and short-circuit issues due to dendritic growth on the Li metal anode from lithium plating during charge-discharge cycles. A solid state electrolyte, such as garnet/ceramic or solid polymer nanocomposite electrolyte, is a promising approach to make Li metal safely cycling. The solid state electrolyte is non-flammable and eliminates leakage and fire hazard by replacing the liquid flammable electrolyte. However, the low-ionic conductivity and high interfacial impedance are the key issues to be overcome. In this presentation, the research activities on solid state electrolyte development funded by the NASA Advanced Energy Storage System program and by the NASA Center Innovative Fund will be presented, and the progress and results will be also discussed.

Wu, James J.↗

EOS-AM1 Nickel Hydrogen Cell Interim Life Test Report

This paper reports the interim results of the Earth Observing System AM-1 project (EOS-AM-1) nickel hydrogen cell life test being conducted under contract to National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) at the Lockheed Martin Missiles and Space (LMMS) facility in East Windsor, NJ; and at COMSAT Labs., Clarksburg, MD. The purpose of the tests is to verify that the EOS-AM-l cell design can meet five years of real-time Low Earth Orbit (LEO) cycling. The tests include both real-time LEO and accelerated stress tests. At LMMS, the first real-time LEO simulated 99 minute orbital cycle started on February 7, 1994 and the test has been running continuously since that time, with 13000 LEO cycles completed as of September 2, 1996. Each cycle consists of a 64 minute charge (VT at 1.507 volts per cell, 1.06 C/D ratio, followed by 0.6 ampere trickle charge) and a 35 minute constant power discharge at 177 watts (22.5% DOD). At COMSAT, the accelerated stress test consists of 90 minute orbital cycles at 60% DOD with a 30 minute discharge at 60 amperes and a 60 minute charge at 40 ampercs (VT at 1.54 volts per cell to 1.09 C/D ratio, followed by 0.6 ampere trickle charge). The real-time LEO life test battery consists of seven, 50AH (nameplate rating) Eagle-Picher, Inc. (EPI) Mantech cells manufactured into three, 3-cell pack assemblies (there are two place holder cells that are not part of the life test electrical circuit). The test pack is configured to simulate the conductive thermal design of the spacecraft battely, including: conductive aluminum sleeves, 3-cell pack aluminum baseplate, and honeycomb panel all mounted to a liquid (-5 C) cold plate. The entire assembly is located in a thermal chamber operating at +3 C. The accelerated stress test unit consists of five cells mounted in machined aluminum test sleeves and is operating at +10 C. The real-time LEO life test battery has met all performance requirements through the first 13,000 cycles, including: end of charge and discharge cell voltages and voltage gradients; end of chalge and discharge cell pressures; within cell and between cell temperature gradients; discharge capacity; current and power levels; and all chalge parameters. The accelerated stress test battely has completed over 5900 cycles as of 9/11/96. This paper reports both battery performances as a function of cycle life, with individual cell performance comparisons repolted for selected cycles in both tests.

Bennett, C. W.↗