Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam independence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Simultaneous active control of flexural and extensional waves in beams

The simultaneous active control of flexural and extensional vibrations in elastic beams is experimentally investigated. The results demonstrate that using pairs of piezoceramic transducers, whose elements are symmetrically located and independently controlled by a multichannel adaptive controller, enables the high attenuation of both flexural and extensional response. This capability is due to the nature of the piezoceramic element, which when bonded to the surface of the structure and electrically excited, exerts a surface strain on the structure. This strain enables input of both shear forces and moments into the structural system. The results are applicable to many situations where extensional vibrations couple to large flexural vibrations and subsequently radiate significant sound levels.

Fuller, C. R.↗

The design and fabrication of a single leakage-channel grating coupler

The modeling and fabrication is described of waveguide grating couplers with out-coupling efficiencies into a single diffracted order nearing 100 pct. Termed Single Leakage Channel Grating Couplers (SLCGCs), these devices use a high reflectivity dielectric stack to reflect the out-coupled beam diffracted toward the substrate, back up into the air region where it constructively adds with the beam diffracted into the air region. Computer modeling shows that the branching ratio and the leakage rate can be independently controlled, and that the branching ratio is independent of grating depth and grating period. A SLCGC with a branching ratio of 97.1 pct. was fabricated using a combination of vacuum evaporation and wet chemical techniques.

Roncone, Ronald L.↗

Minority carrier diffusion length and edge surface-recombination velocity in InP

A scanning electron microscope was used to obtain the electron-beam-induced current (EBIC) profiles in InP specimens containing a Schottky barrier perpendicular to the scanned (edge) surface. An independent technique was used to measure the edge surface-recombination velocity. These values were used in a fit of the experimental EBIC data with a theoretical expression for normalized EBIC (Donolato, 1982) to obtain the electron (minority carrier) diffusion length.

Hakimzadeh, Roshanak↗

Multi-cathode unbalanced magnetron sputtering systems

Ion bombardment of a growing film during deposition is necessary in many instances to ensure a fully dense coating, particularly for hard coatings. Until the recent advent of unbalanced magnetron (UBM) cathodes, reactive sputtering had not been able to achieve the same degree of ion bombardment as other physical vapor deposition processes. The amount of ion bombardment of the substrate depends on the plasma density at the substrate, and in a UBM system the amount of bombardment will depend on the degree of unbalance of the cathode. In multi-cathode systems, the magnetic fields between the cathodes must be linked to confine the fast electrons that collide with the gas atoms. Any break in this linkage results in electrons being lost and a low plasma density. Modeling of the magnetic fields in a UBM cathode using a finite element analysis program has provided great insight into the interaction between the magnetic fields in multi-cathode systems. Large multi-cathode systems will require very strong magnets or many cathodes in order to maintain the magnetic field strength needed to achieve a high plasma density. Electromagnets offer the possibility of independent control of the plasma density. Such a system would be a large-scale version of an ion beam enhanced deposition (IBED) system, but, for the UBM system where the plasma would completely surround the substrate, the acronym IBED might now stand for Ion Blanket Enhanced Deposition.

Sproul, William D.↗

Sampling off-axis neutrino fluxes with the short-baseline near detector

The short-baseline near detector (SBND), the near detector in the short-baseline neutrino program at Fermi National Accelerator Laboratory, is located just 110 m from the booster neutrino beam target. Thanks to this close proximity, relative to its 4 m × 4 m front face, neutrinos enter SBND over a range of angles from 0° to approximately 1.6°, enabling the detector to sample variations in the neutrino flux as a function of the angle—a technique known as precision reaction-independent spectrum measurement (PRISM), referred to here as SBND-PRISM. In this paper, we show how muon- and electron-neutrino fluxes vary as a function of the neutrino beam axis angle and how this can be exploited to expand the physics potential of SBND. We make use of a model that predicts an angle-dependent electron-neutrino excess signal to illustrate this effect, such as 𝜈 𝜇 → 𝜈 𝑒 oscillations. We present how SBND-PRISM provides a method to add robustness against uncertainties in cross-section modeling and, more generally, uncertainties that do not depend on the spatial position of neutrino interaction inside the detector. The fluxes, along with their associated covariance matrices, are made publicly available with this publication.

Abratenko, P. [Tufts University]↗

A Diamagnetic-Loop-Based Beam Radius Monitor (BRM)

We describe a non-interceptive beam radius monitor that employs a diamagnetic loop. In order to increase the signal strength, the diamagnetic loop radius is considerably smaller than the outer wall radius, the device is placed inside a specially built solenoid magnet to allow independent adjustment of the guide magnetic field strength, and there are two counter-wound diamagnetic loops to double the signal strength and to eliminate common mode signals. This device is calibrated and the magnitude of the electron beam offset/tilt contribution to the measured radius estimated. This device is ready to be validated on an electron induction LINAC such a DARHT-I or DARHT-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impulsive phase solar flare X-ray polarimetry

The pioneering observational work in solar flare X-ray polarimetry was done in a series of satellite experiments by Tindo and his collaborators in the Soviet Union; initial results showed high levels of polarization in X-ray flares (up to 40%), although of rather low statistical significance, and these were generally interpreted as evidence for strong beaming of suprathermal electrons in the flare energy release process. However, the results of the polarimeter flown by the Columbia Astrophysics Laboratory as part of the STS-3 payload on the Space Shuttle by contrast showed very low levels of polarization. The largest value (observed during the impulsive phase of a single event) was 3.4% + or - 2.2%. At the same time but independent of the observational work, Leach and Petrosian (1983) showed that the high levels of polarization in the Tindo results were difficult to understand theoretically, since the electron beam is isotropized on an energy loss timescale. A subsequent comparison by Leach, Emslie, and Petrosian (1985) of the impulsive phase STS-3 result and the above theoretical treatment shows that the former is consistent with several current models and that a factor of approximately 3 improvement in sensitivity is needed to distinguish properly among the possibilities.

Chanan, Gary↗

Search for an Excess of Electron Neutrino Interactions in MicroBooNE Using Multiple Final State Topologies (submitted to PRL)

We present a measurement of ν e interactions from the Fermilab Booster Neutrino Beam using the MicroBooNE liquid argon time projection chamber to address the nature of the excess of low energy interactions observed by the MiniBooNE collaboration. Three independent ν e searches are performed across multiple single electron final states, including an exclusive search for two-body scattering events with a single proton, a semi-inclusive search for pionless events, and a fully inclusive search for events containing all hadronic final states. With differing signal topologies, statistics, backgrounds, reconstruction algorithms, and analysis approaches, the results are found to be consistent with the nominal ν e rate expectations from the Booster Neutrino Beam and no excess of ν e events is observed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Three axis rotational maneuver and vibration stabilization of elastic spacecraft

A control law for three-axis rotational maneuvers of a spacecraft beam-tip body configuration based on non-linear inversion and modal velocity feedback is presented. A decoupling attitude control law is presented such that in the closed-loop system the attitude angles of the spacecraft are independently controlled, using the control moments acting on the space vehicle. This controller asymptotically decouples the flexible dynamics from the rigid one and also allows the decomposition of the elastic dynamics into two subsystems representing the transverse deflections of the beam in two orthogonal planes. These low-order subsystems are used for the derivation of a modal velocity feedback stabilizer using the force and moment actuators at the end body. Simulation results are presented to show the capability of the controller.

Singh, Sahjendra N.↗

An antenna for limited scan in one plane - Design criteria and numerical simulation

Aperture illumination is synthesized through the use of overlapping subarrays with independently controlled excitations. Detailed analysis and design criteria are provided for a specific limited-scan antenna configuration scanning in one plane. The number of phase shifts is the theoretical minimum corresponding to specified aperture size and field of view. Beam pointing and width are approximately constant for moderate frequency variation, and ultralow sidelobes outside the field of view can be produced at the cost of a slight loss of illumination efficiency. Accurate aperture illumination control makes for excellent independently specified sum and difference patterns in beamforming.

Borgiotti, G. V.↗

Deeply Virtual Compton Scattering Using a Positron Beam in Hall-C at Jefferson Lab

In this study we propose to use the High Momentum Spectrometer of Hall C combined with the Neutral Particle Spectrometer (NPS) to perform high precision measurements of the Deeply Virtual Compton Scattering (DVCS) cross section using a beam of positrons. The combination of measurements with oppositely charged incident beams is the only unambiguous way to disentangle the contribution of the DVCS 2 term in the photon electroproduction cross section from its interference with the Bethe-Heitler amplitude. This provides a stronger way to constrain the Generalized Parton Distributions of the nucleon. A wide range of kinematics accessible with an 11 GeV beam off an unpolarized proton target will be covered. The $\mathcal{Q}^2$-dependence of each contribution will be measured independently.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The measurement of the winds near the ocean surface with a radiometer-scatterometer on Skylab

The author has identified the following significant results. There were a total of twenty-six passes in the ZLV mode that yielded useful data. Six were in the in-track noncontiguous mode; all others were in the cross-track noncontiguous mode. The wind speed and direction, as effectively determined in a neutral atmosphere at 19.5 m above the sea surface, were found for each cell scanned by S193. It is shown how the passive microwave measurements were used both to compute the attenuation of the radar beam and to determine those cells where the backscatter measurement was suspect. Given the direction of the wind from some independent source, with the typical accuracy of measurement by available meteorological methods, a backscatter measurement at a nadir angle of 50, 43, or 32 deg can be used to compute the speed of the wind averaged over the illuminated area.

Pierson, W. J.↗

On the importance of reverse current ohmic losses in electron-heated solar flare atmospheres

The passage of a beam of nonthermal electrons through the flaring solar atmosphere is considered, paying particular attention to the requirement that the beam be stable to the generation of plasma turbulence. The ratio is computed of energy losses due to reverse current ohmic heating, and heating by Coulomb collisions, respectively, for the greatest flux which can pass stably through the atmosphere. It is demonstrated that this ratio is determined by the low energy cutoff of the beam, by the electron temperature of the ambient atmosphere, and by the electron to ion temperature ratio. It is also independent of the atmospheric density.

Emslie, A. G.↗

A rough-surface thermophysical model for airless planets

A model for determining diurnal temperatures in spherical-section depressions and which encompasses both subsurface heat-flow and direct and scattered sunlight effects is presently applied to the disk-integrated thermal emission of a rough planetary surface with nonzero thermal inertia. Attention is given to the variation with roughness and thermal inertia of the beaming parameter eta, which characterizes zero-phase thermal emission by comparison with a smooth, nonrotating body and is almost independent of albedo for a given surface roughness. The thermal phase curve of Ceres is noted to be well matched by the model features of (1) prograde rotation, (2) 44-deg rms surface slope, and (3) a thermal inertia that is 30 percent of the lunar value.

Spencer, John R.↗

Measurement of the minority carrier diffusion length and edge surface-recombination velocity in InP

A scanning electron microscope (SEM) was used to measure the electron (minority carrier) diffusion length (L(sub n)) and the edge surface-recombination velocity (V(sub s)) in zinc-doped Czochralski-grown InP wafers. Electron-beam-induced current (EBIC) profiles were obtained in specimens containing a Schottky barrier perpendicular to the scanned (edge) surface. An independent technique was used to measure V(sub s), and these values were used in a theoretical expression for normalized EBIC. A fit of the experimental data with this expression enabled us to determine L(sub n).

Bailey, Sheila G.↗

A measurement of the medium-scale anisotropy in the cosmic microwave background radiation

Observations from the first flight of the Medium Scale Anisotropy Measurement (MSAM) are analyzed to place limits on Gaussian fluctuations in the cosmic microwave background radiation (CMBR). This instrument chops a 30 min beam in a three-position pattern with a throw of +/- 40 min; the resulting data is analyzed in statistically independent single- and double-difference sets. We observe in four spectral channels at 5.6, 9.0, 16.5, and 22.5/cm, allowing the separation of interstellar dust emission from CMBR fluctuations. The dust component is correlated with the IRAS 100 micron map. The CMBR component has two regions where the signature of an unresolved source is seen. Rejecting these two source regions, we obtain a detection of fluctuations which match CMBR in our spectral bands of 0.6 x 10(exp -5) is less than Delta (T)/T is less than 2.2 x 10(exp -5) (90% CL interval) for total rms Gaussian fluctuations with correlation angle 0.5 deg, using the single-difference demodulation. Fore the double difference demodulation, the result is 1.1 x 10(exp -5) is less than Delta(T)/T is less than 3.1 x 10(exp -5) (90% CL interval) at a correlation angle of 0.3 deg.

Cheng, E. S.↗

Multi-Gas Sensor

A multi-gas sensor is provided which modulates a polarized light beam over a broadband of wavelengths between two alternating orthogonal polarization components. The two orthogonal polarization components of the polarization modulated beam are directed along two distinct optical paths. At least one optical path contains one or more spectral discrimination element, with each spectral discrimination element having spectral absorption features of one or more gases of interest being measured. The two optical paths then intersect, and one orthogonal component of the intersected components is transmitted and the other orthogonal component is reflected. The combined polarization modulated beam is partitioned into one or more smaller spectral regions of interest where one or more gases of interest has an absorption band. The difference in intensity between the two orthogonal polarization components is then determined in each partitioned spectral region of interest as an indication of the spectral emission/absorption of the light beam by the gases of interest in the measurement path. The spectral emission/absorption is indicative of the concentration of the one or more gases of interest in the measurement path. More specifically, one embodiment of the present invention is a gas filter correlation radiometer which comprises a polarizer, a polarization modulator, a polarization beam splitter, a beam combiner, wavelength partitioning element, and detection element. The gases of interest are measured simultaneously and, further, can be measured independently or non-independently. Furthermore, optical or electronic element are provided to balance optical intensities between the two optical paths.

Sachse, Glenn W.↗

Method for Balancing Detector Output to a Desired Level of Balance at a Frequency

A multi-gas sensor is provided which modulates a polarized light beam over a broadband of wavelengths between two alternating orthogonal polarization components. The two orthogonal polarization components of the polarization modulated beam are directed along two distinct optical paths. At least one optical path contains one or more spectral discrimination elements, with each spectral discrimination element having spectral absorption features of one or more gases of interest being measured. The two optical paths then intersect, and one orthogonal component of the intersected components is transmitted and the other orthogonal component is reflected. The combined polarization modulated beam is partitioned into one or more smaller spectral regions of interest where one or more gases of interest has an absorption band. The difference in intensity between the two orthogonal polarization components is then determined in each partitioned spectral region of interest as an indication of the spectral emission/absorption of the light beam by the gases of interest in the measurement path. The spectral emission/absorption is indicative of the concentration of the one or more gases of interest in the measurement path. More specifically, one embodiment of the present invention is a gas filter correlation radiometer which comprises a polarizer, a polarization modulator, a polarization beam splitter, a beam combiner, wavelength partitioning element, and detection element. The gases of interest are measured simultaneously and, further, can be measured independently or non-independently. Furthermore, optical or electronic element are provided to balance optical intensities between the two optical paths.

Sachse, Glenn W.↗