Search NASA⌕ Search

SEARCH · Search NASA

Results for “building information model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Mechanistic modeling of copper corrosions in data center environments

Air-side economizers are increasingly used to take advantage of “free-cooling” in data centers with the intent of reducing the carbon footprint of buildings. However, they can introduce outdoor pollutants to indoor environment of data centers and cause corrosion damage to the information technology equipment. Here, to evaluate the reliability of information technology equipment under various thermal and air-pollution conditions, a mechanistic model based on multi-ion transport and chemical reactions was developed. The model was used to predict Cu corrosion caused by Cl2-containing pollutant mixtures. It also accounted for the effects of temperature (25 °C and 28 °C), relative humidity (50%, 75%, and 95%), and synergism. It also identified higher air temperature as a corrosion barrier and higher relative humidity as a corrosion accelerator, which agreed well with the experimental results. The average root mean square error of the prediction was 13.7 Å. The model can be used to evaluate the thermal guideline for data centers design and operation when Cl2 is present based on pre-established acceptable risk of corrosion in data centers’ environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using Time Series Data Products to Support ASHRAE’s Historic and Future Climate Data Needs through NASA’s POWER Web Services

To address the data needs for resilience and sustainability of building systems within ASHRAE, the NASA Prediction of Worldwide Energy Resource (POWER) project facilitates the use of NASA Earth Science data on a long-term, global scale. Solar data from several NASA projects and meteorological data from NASA assimilation models have been reformatted and disseminated to the public via a user friendly web GIS-enabled based data portal (https://power.larc.nasa.gov) in selectable data formats, immediately amenable to key industry wide decision support tools such as EnergyPlus. Time series of potential climate conditions from downscaled climate simulations are being made available for similar statistics and formats. An emphasis is placed upon obtaining and utilizing time series data to conduct analysis of building system performance for current and planning building systems for energy savings and greenhouse gas emissions. This presentation has the learning following learning objectives for the ASHRAE community: 1) Learn how NASA POWER’s web service suite can provide supplementary solar and surface meteorological data parameters, including a discussion of uncertainty. 2) Learn how downscaled climate scenario information can be provided to evaluate potential future requirements. The presentation is part of a forum entitled, "Weather Data for Large-Scale Building Energy Modeling".

time series↗

Localizing Earth Science: The NASA DEVELOP Model of Community Science & Engagement

NASA’s DEVELOP Program conducts rapid feasibility studies that apply Earth observations to address community priorities and needs and enable informed decision making. Part of NASA’s Applied Sciences’ Capacity Building Program, DEVELOP builds skills in both participants (students, recent graduates, and early/transitioning career professionals) who conduct projects on small teams, and partner organizations (state and local governments, federal agencies, non-profit and for-profit organizations, and international organizations) that work closely with DEVELOP to design the project. While only a subset of DEVELOP partner organizations are local municipalities or community-led non-profits, the DEVELOP model is an effective engagement tool and often used by NASA as an introduction for communities to engage in Earth science research and familiarization with satellite remote sensing. This presentation will highlight the DEVELOP model of co-production and community collaboration, lessons learned in partnering with local communities, and evaluation activities that look at the program’s reach and efforts.

Robert Cecil Byles↗

Short-wavelength-sensitive 2 (Sws2) visual photopigment models combined with atomistic molecular simulations to predict spectral peaks of absorbance

For many species, vision is one of the most important sensory modalities for mediating essential tasks that include navigation, predation and foraging, predator avoidance, and numerous social behaviors. The vertebrate visual process begins when photons of the light interact with rod and cone photoreceptors that are present in the neural retina. Vertebrate visual photopigments are housed within these photoreceptor cells and are sensitive to a wide range of wavelengths that peak within the light spectrum, the latter of which is a function of the type of chromophore used and how it interacts with specific amino acid residues found within the opsin protein sequence. Minor differences in the amino acid sequences of the opsins are known to lead to large differences in the spectral peak of absorbance (i.e. the λ max value). In our prior studies, we developed a new approach that combined homology modeling and molecular dynamics simulations to gather structural information associated with chromophore conformation, then used it to generate statistical models for the accurate prediction of λ max values for photopigments derived from Rh1 and Rh2 amino acid sequences. In the present study, we test our novel approach to predict the λ max of phylogenetically distant Sws2 cone opsins. To build a model that can predict the λ max using our approach presented in our prior studies, we selected a spectrally-diverse set of 11 teleost Sws2 photopigments for which both amino acid sequence information and experimentally measured λ max values are known. The final first-order regression model, consisting of three terms associated with chromophore conformation, was sufficient to predict the λ max of Sws2 photopigments with high accuracy. This study further highlights the breadth of our approach in reliably predicting λ max values of Sws2 cone photopigments, evolutionary-more distant from template bovine RH1, and provided mechanistic insights into the role of known spectral tuning sites.

59 BASIC BIOLOGICAL SCIENCES↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupling multi-fidelity xRAGE with machine learning for graded inner shell design optimization in double shell capsules

Bayesian optimization has shown promise for the design optimization of inertial confinement fusion targets. Specifically, in Vazirani et al. [Phys. Plasmas 28 , 122709 (2021)], optimal designs for double shell capsules with graded inner shells were identified using one-dimensional xRAGE simulation yield calculations. While the machine learning models were able to accurately learn and predict one-dimensional simulation target performance, using simulations with higher fidelity would improve design optimization and better match with the expected experimental performance. However, higher fidelity physics modeling, i.e., two-dimensional xRAGE simulations, requires significantly larger computational time/cost, usually at least an order of magnitude, in comparison with one-dimensional simulations. This study presents a multi-fidelity Bayesian optimization, in which the machine learning model leverages low-fidelity (one-dimensional xRAGE) and high-fidelity (two-dimensional xRAGE) simulations to more accurately predict “pre-shot” target performance with respect to the expected experimental performance. By building a multi-fidelity Bayesian optimization framework coupled with xRAGE, the low-fidelity and high-fidelity simulations are able to inform one another, such that we have: (1) improved physics modeling in comparison with using low-fidelity simulations alone, (2) reduced computational time/cost in comparison with using high-fidelity simulations alone, and (3) more confidence in the expected performance of optimized targets during real-world experiments. In the future, we plan to use this robust multi-fidelity Bayesian optimization methodology to expedite the design of graded inner shells further and eventually full capsules as a part of the current double shell campaign at the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active learning strategy for high fidelity short-term data-driven building energy forecasting

The quality of a data-driven model is heavily dependent on the quality of data. Data from building operation often have data bias problems, which means that the data sample is collected in a way that some members of the intended data population are less likely to be included than others. Data-driven energy forecasting models built on such data hence are biased and could lead to large forecasting errors. Active learning—an effective method to defying data bias—is rarely studied or applied in the area of data-driven building energy forecasting modeling. This paper attempts to fill this gap and explores the application of active learning in data-driven building energy forecasting. The developed strategy in this paper efficiently generate informative training data within a time budget and uses block design to passively consider weather disturbances. The developed active learning strategy is applied and evaluated in both virtual and real-building testbeds against traditional data-driven methods. Via these virtual and real-building evaluation cases, we have demonstrated that the data bias problem typically exists in building operation data is resolved by applying the developed active learning strategy. Furthermore, building energy forecasting models trained from data generated from the active learning strategy have shown improved performances in both model accuracy and model extendibility perspectives. The effectiveness of the block design module is also validated to effectively consider the impact of weather conditions on active learning design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Framework for Optimal Placement of Rooftop Photovoltaic: Maximizing Solar Production and Operational Cost Savings in Residential Communities

Optimizing the placement of photovoltaic (PV) panels on residential buildings has the potential to significantly increase energy efficiency benefits to both homeowners and communities. Strategic PV placement can lower electricity costs by reducing the electricity fed from the grid during on-peak hours, while maintaining PV panel efficiency in terms of the amount of solar radiation received. In this article, we present a framework that identifies the ideal location of PV panels on residential rooftops. Our framework combines energy and environmental simulation, parametric modeling, and optimization to inform PV placement as it relates to and affects the entire community (in terms of both energy use and financial cost), as well as individual buildings. Ensuring that our framework accounts for shading from nearby buildings, different utility rate structures, and different buildings’ energy demand profiles means that existing communities and future housing developments can be optimized for energy savings and PV efficiency. The framework comprises two workflows, each contributing to optimal PV placement with a unique target: (a) maximizing PV panel efficiency (i.e., solar generation) and (b) minimizing operational energy cost considering utility rate structures for operational energy. We apply our framework to a residential community in Fort Collins, Colorado, to demonstrate the optimal PV placement, considering the two workflow targets. Here, we present our results and illustrate the effect of PV location and orientation on solar energy production efficiency and operational energy cost.

14 SOLAR ENERGY↗

The NASA DEVELOP Model of Community Science & Engagement: Localizing Earth Science Information

The NASA DEVELOP Program conducts 10 week feasibility studies that apply Earth observation data to address community priorities and support informed decision making. Part of NASA’s Earth Action Capacity Building Program, DEVELOP builds skills in both participants ( recent graduates, and early/transitioning career professionals), who work on small interdisciplinary project teams, and partner organizations (state and local governments, federal agencies, non profit and for profit organizations, universities, and international organizations) that work closely with DEVELOP to design the project. Projects address a wide variety of environmental issues, such as disaster risk and resilience, air pollution, and the impact of urban development, with a growing number of projects exploring how satellite data can help inform decision making around environmental injustices. A subset of DEVELOP partner organizations are local municipalities or community led non profits, with the co production model serving as an effective engagement tool and an introduction for communities to engage in Earth science research and become familiar with satellite remote sensing. This presentation will highlight the DEVELOP co production model, community project use cases, and lessons learned in partnering with local communities.

Michael Pazmino↗

Component Assessment of the Electric Transmission Grid to Hurricanes

The increased frequency and intensity of extreme weather events from climate change necessitates understanding impacts on critical infrastructure, particularly electrical transmission grids. One of the foundational concepts of a grid's resilience is its robustness to extreme weather events, such as hurricanes. Resilience of the electric grid to high wind speeds is predicated upon the location and physical characteristics of the system components. Previous modeling assessments of electric grid failure were done at the systems level with assumptions on location and type of specific components. To facilitate more explicit adaptation metrics, accurate component-level information is needed. In this study, we build and utilize a data set of location, physical characteristics, and age of transmission structures for nine counties in the Florida Panhandle. These component characteristics were then simulated for failure under a variety of scenarios using fragility curves. Eight hurricanes were modeled using Hazus from the Federal Emergency Management Administration and the resulting impact to the network was assessed. The network was generated using the transmission lines and towers, showing increasing impacts to network efficiency with larger storms. Although modern transmission structures are built under the more stringent extreme wind loading construction standards, the prevalence of older, wooden transmission structures throughout the region poses a substantial risk to reliable electricity transmission during tropical cyclone events from the Gulf of Mexico.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nuclear Power's Future Role in a Decarbonized U.S. Electricity System

This study explores the potential future role of nuclear energy in a decarbonized U.S. electricity system through a multi-model comparison approach. We employ four state-of-the-art CEMs with native and harmonized input assumptions, layered with different policy and technology trajectories. Comparing outputs across models, technology assumptions, and policy scenarios informs model understanding, interpretation, and development decisions. Under current policies, models differ in their projections for nuclear retirements, but nuclear power plants consistently run with high capacity factors and new builds only occur in scenarios with very low nuclear costs. String power sector carbon policies drive models to align in keeping existing nuclear capacity and employing nuclear plant flexibility, but they may not be enough to bring new nuclear capacity online in the absence of significant cost declines. Therefore, significant economic deployment of new nuclear capacity requires both a stringent electric sector CO2 policy and very low cost assumptions for new nuclear. While these scenarios should not be interpreted as predictions, they are informative for understanding differing model assessments of the relative competitiveness of nuclear energy under a range of policy and technology conditions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock: Preprint

20% of the U.S. commercial building sector's energy usage is from on-site combustion of fossil fuels for heating. Decarbonization will require electrification of these systems to meet climate goals, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for decarbonization solutions. However, there is limited understanding of the impact on emissions that considers regional electricity generation methods, as well as the impact of other heat pump intricacies such as the effects of temperature on capacity/efficiency, defrost operation, realistic sizing methodologies, and supplementary heating. This study explores the effects of transitioning all conventional RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock, DOE's calibrated model of the U.S. commercial building stock developed by NREL. Results show 9% and 17% reductions in stock aggregate energy consumption and GHG emissions, respectively. Furthermore, average heat pump operational details are presented by state. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building electrification↗

Leveraging visible and near-infrared spectroelectrochemistry to calibrate a robust model for Vanadium(IV/V) in varying nitric acid and temperature levels

Spectroelectrochemistry and optimal design of experiments can be used to rapidly build accurate models for species quantification and enable a greater level of process awareness. Optical spectroscopy can provide vital elemental and molecular information, but several hurdles must be overcome before it can become a widely adopted analytical method for remote analysis in the nuclear field. Analytes with varying oxidation state, acid concentration, and fluctuating temperature must be efficiently accounted for to minimize time and resources in restrictive hot cell environments. The classic one-factor-at-a-time approach is not suitable for frequent calibration/maintenance operations in this setting. Therefore, a novel alternative was developed to characterize a system containing vanadium(IV/V) (0.01–0.1 M), nitric acid (0.1–4 M), and varying temperatures (20–45 °C). Here, spectroelectrochemistry methods were used to acquire a sample set selected by optimal design of experiments. This new approach allows for the accurate analysis of vanadium and HNO 3 concentration by leveraging UV–Vis–NIR absorption spectroscopy with robust and accurate chemometric models. The top model's root mean squared error of prediction percent values were 3.47%, 4.06%, 3.40%, and 10.9% for V(IV), V(V), HNO 3 , and temperature, respectively. These models, efficiently developed using the designed approach, exhibited strong predictive accuracy for vanadium and acid with varying oxidation states and temperature using only spectrophotometry, which advances current technology for real-world hot cell applications. Additionally, Nernstian analysis of the V(IV/V) standard potential was performed using traditional absorbance methods and multivariate curve resolution (MCR). The successful tests demonstrated that MCR Nernst tests may be valuable in highly convoluted spectral systems to better understand the redox processes' behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Super-resolution stimulated X-ray Raman spectroscopy

Propagation of intense X-ray pulses through dense media has led to the observation of phenomena such as atomic X-ray lasing, self-induced transparency and stimulated X-ray Raman scattering (SXRS)4. SXRS has been long predicted as a means to launch and probe valence-electron wavepackets and as a building block for nonlinear X-ray spectroscopies. However, experimental observations of SXRS to date have not provided spectroscopic information, and theoretical modelling has largely implemented hard-to-realize phase-coherent attosecond pulses. Here we demonstrate SXRS with spectroscopic precision, that is, detection of valence-excited states in neon with a near Fourier-limited joint energy–time resolution of 0.1 eV–40 fs. We used a new covariance analysis between statistically spiky broadband incident X-ray and scattered X-ray Raman pulses. Using 18,000 single shots, we beat not only the incident (about 8 eV) bandwidth but also the approximately 0.2 eV instrumental energy resolution, thus creating super-resolution conditions, in analogy to super-resolved fluorescence microscopy. Our experimental results, supported by ab initio propagation simulations, reveal the competition between lasing in the ion and stimulated Raman scattering in the neutral. We demonstrate enhanced signal collection efficiency and a broad excitation window, surpassing spontaneous Raman efficiencies by orders of magnitude. This stochastic SXRS approach represents a first step towards tracking elementary events that determine chemical outcomes.

nonlinear x-ray spectroscopy↗

Leveraging Fine-Grained Occupancy Estimation Patterns for Effective HVAC Control

As occupancy sensing technologies become mature, various occupancy sensors are increasingly deployed in commercial buildings for pervasive occupancy monitoring. These sensors provide occupant-count data, which contains rich spatiotemporal information about occupancy patterns. With long-term occupant-count data collected from a commercial building, we design three different predictive models that capture the occupancy dynamics and examine how a model predictive control of the HVAC system benefits from actual occupancy count prediction. Our analysis reveals that mispredictions of occupancy states, especially false positives and false negatives, may introduce inefficient control that leads to energy waste or user discomfort. To address this issue, we take a step further to design an adaptive model predictive controller that minimizes inefficient control actions according to misprediction types and distributions. A comprehensive evaluation is performed in OpenBuild and EnergyPlus simulators to study the effectiveness of the proposed end-to-end control strategy. The evaluation shows that the proposed solution reduces energy consumption by 29.5% while improving the average weighted occupants comfort by 86.7% in Predicted Mean Vote (PMV) over the fixed schedule strategy.

97 MATHEMATICS AND COMPUTING↗

Meta-Modeling: A Knowledge-Based Approach to Facilitating Model Construction and Reuse

In this paper, we introduce a new modeling approach called meta-modeling and illustrate its practical applicability to the construction of physically-based ecosystem process models. As a critical adjunct to modeling codes meta-modeling requires explicit specification of certain background information related to the construction and conceptual underpinnings of a model. This information formalizes the heretofore tacit relationship between the mathematical modeling code and the underlying real-world phenomena being investigated, and gives insight into the process by which the model was constructed. We show how the explicit availability of such information can make models more understandable and reusable and less subject to misinterpretation. In particular, background information enables potential users to better interpret an implemented ecosystem model without direct assistance from the model author. Additionally, we show how the discipline involved in specifying background information leads to improved management of model complexity and fewer implementation errors. We illustrate the meta-modeling approach in the context of the Scientists' Intelligent Graphical Modeling Assistant (SIGMA) a new model construction environment. As the user constructs a model using SIGMA the system adds appropriate background information that ties the executable model to the underlying physical phenomena under investigation. Not only does this information improve the understandability of the final model it also serves to reduce the overall time and programming expertise necessary to initially build and subsequently modify models. Furthermore, SIGMA's use of background knowledge helps eliminate coding errors resulting from scientific and dimensional inconsistencies that are otherwise difficult to avoid when building complex models. As a. demonstration of SIGMA's utility, the system was used to reimplement and extend a well-known forest ecosystem dynamics model: Forest-BGC.

Keller, Richard M.↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Provable Security and Resilience in Critical Infrastructure – Next Steps

With the conclusion of the Laboratory Directed Research and Development (LDRD) project on Provable Security and Resilience (PSaR) in Critical Infrastructure, we present forward-looking technical concepts and strategies that build on the project’s outcomes and INL’s long-standing expertise in infrastructure protection. The challenge is to protect critical infrastructure and functions much more efficiently at scale than capable adversaries can attack at scale. After summarizing progress and ongoing work we’ll discuss what are the challenges that remain and what are new/emerging technologies, strategies, and processes to meet those challenges. Finally, we’ll layout concepts that integrate with other protection work in the coming year and beyond. For example, building secure function-specific platforms based on the seL4 microkernel, and considering the successes of Cyber-Informed Engineering as a model for engage, collaboration, and adoption. We look forward to your feedback and collaboration as we refine and expand this vision.

97 - MATHEMATICS AND COMPUTING↗