Search NASA⌕ Search

SEARCH · Search NASA

Results for “building system optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Peak Demand Limiting and Optimization of HVAC Systems for Common Areas in High-Rise Multi-Family Housing (CRADA 518)

This project aims to create an innovative energy saving solution that is affordable and easy to implement. Initially, the proposed solution will fulfill an existing need for HVAC systems that serve multi-family housing. However, the solution can be easily expanded to other markets such as large hospitals, hotels, and commercial buildings. The proposed solution will be creatively packaged so that it can work where peak demand charge is high or where goal is to conserve energy and reduce carbon footprint. Of course, both Peak Demand Limiting (PDL) and Set-point optimization (SPO) can also operate simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving operational flexibility of integrated energy system with uncertain renewable generations considering thermal inertia of buildings

Insufficient flexibility in system operation caused by traditional "heat-set" operating modes of combined heat and power (CHP) units in winter heating periods is a key issue that limits renewable energy consumption. In order to reduce the curtailment of renewable energy resources through improving the operational flexibility, a novel optimal scheduling model based on chance-constrained programming (CCP), aiming at minimizing the lowest generation cost, is proposed for a small-scale integrated energy system (IES) with CHP units, thermal power units, renewable generations and representative auxiliary equipments. In this model, due to the uncertainties of renewable generations including wind turbines and photovoltaic units, the probabilistic spinning reserves are supplied in the form of chance-constrained; from the perspective of user experience, a heating load model is built with consideration of heat comfort and inertia in buildings. To solve the model, a solution approach based on sequence operation theory (SOT) is developed, where the original CCP-based scheduling model is tackled into a solvable mixed-integer linear programming (MILP) formulation by converting a chance constraint into its deterministic equivalence class, and thereby is solved via the CPLEX solver. We report the simulation results on the modified IEEE 30-bus system demonstrate that the presented method manages to improve operational flexibility of the IES with uncertain renewable generations by comprehensively leveraging thermal inertia of buildings and different kinds of auxiliary equipments, which provides a fundamental way for promoting renewable energy consumption.

30 DIRECT ENERGY CONVERSION↗

Dynamic Facade Dashboard v0.1.0

The dashboard is a useful tool for early-stage building design decision-making and communication, as it can help users quickly compare the energy and non-energy related performance of various automated, integrated facade systems using a library of pre-computed data. Users can explore the impacts of various design choices by selecting different facade glazing and shading systems, facade control strategies, and lighting control strategies across multiple climate zones. The dashboard instantly visualizes key metrics, including energy usage in HVAC and lighting, peak cooling and heating load, and daylight availability, allowing immediate trade-off analysis to optimize building efficiency and comfort.

Yu, Tammie [Lawrence Berkeley National Laboratory ↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SMART-COM – Scalable Multi-Agent Adaptive Resolution Tools for Collaborative Outage Management

The purpose of this grant was to conduct scientific research and prototype applications to support NPP outage staff in their adaptive decision-making in efficient scheduling and resource allocation while preventing violation of safety technical specifications. The project contributed to scientific knowledge and engineering methods in (1) user interface design, (2) scheduling optimization and risk estimation, and (2) natural language processing that would benefit the nuclear power plants in minimizing schedule overruns and even unexpected shutdowns. The research team conducted site visits at a test reactor facility and an operating nuclear power plant to gather necessary information and inputs for research and development of a software application to support NPP staff in executing their outages. The final software application consisted of three modules. First, the natural language processing module supports interactive processing of technical documentation to build a database for outage staff to query non-permissible actions on system components. This module can alleviate outage staff from reviewing extensive documentation and minimize violation of technical specifications, especially in time-sensitive situations. Second, the schedule optimization module schedules outage activities and compute risk indices that outperform existing software and current practice. This module can reduce completion time of an outage that typically have too many activities for human to optimize based on current practice that does not apply the latest operations research. Finally, the visualization module presents progress and risk information of the overall outage and individual activities, as well as enabling access to the natural language processing and schedule optimization modules. This module can provide outage staff with situation awareness that are necessary to make risk-informed decisions in response to unexpected events during the execution of an outage.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparing Designed Training Sets to Optimize Multivariate Regression Models for Pr, Nd, and Nitric Acid Using Spectrophotometry

Chemometric regression models were developed for the quantification of praseodymium (Pr, 0–1000 µg/mL), neodymium (Nd, 0–1000 µg/mL), and nitric acid (HNO 3 , 0.1–5 M) using spectrophotometry. Designed calibration sets were composed of 20 samples each: 10 model points and 10 lack-of-fit (LOF) points. The D-optimal designs effectively minimized the number of samples required to build models, and each design resulted in similar prediction performance, suggesting that statistical design of experiments can provide a reliable framework for selecting training set samples in three-variable systems. Partial least squares regression (PLSR) models were validated against a one-factor-at-a-time validation set composed of 125 samples (three variables, five levels). The top PLS-1 models resulted in average percent root mean square error of prediction error values of 3.5%, 1.7%, and 1.2% for Pr(III), Nd(III), and HNO 3 , respectively. Power set augmentations of the model and LOF samples were investigated to optimize the number of training set samples. PLSR models built using just required model points (10) had similar predictive capabilities as models including the LOF points (20) but with fewer samples. The number of validation samples was also varied systematically to learn how many samples are needed to validate regression models. This work addresses long-standing questions in the field of chemometrics to help make this approach amenable to the near-real-time quantification of hazardous species in remote settings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine learning based simultaneous control of air handling unit discharge air and condenser water temperatures set-point for minimized cooling energy in an office building

In this study, an artificial intelligence based real-time prediction and control model to optimize condenser water temperature and discharge air temperature (DAT) set-points in water-cooled air handling unit (AHU) system has been developed. EnergyPlus-MATLAB co-simulation has been conducted to analyze the developed model's effectiveness. Here, to develop artificial neural networks (ANN) model, embedded neural network objects in MATLAB was utilized. The developed model could decide an optimal temperature set-points based on outdoor air wet-bulb temperature to reflect the Korean climate context. As a result, the developed ANN prediction model showed the predictive performance of Cv(RMSE) of approximately 21%. Compared to the conventional fixed temperature algorithm, which fixes AHU DAT at 14°C and condenser water temperature at 32°C, the ANN based optimized control showed a 22% total cooling energy reduction. These results show that significant energy savings can be achieved by simultaneously controlling condenser water temperature and AHU DAT set-points considering Korean climatic characteristics using AI technologies such as ANN models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accelerating the design of lattice structures using machine learning

Lattices remain an attractive class of structures due to their design versatility; however, rapidly designing lattice structures with tailored or optimal mechanical properties remains a significant challenge. With each added design variable, the design space quickly becomes intractable. To address this challenge, research efforts have sought to combine computational approaches with machine learning (ML)-based approaches to reduce the computational cost of the design process and accelerate mechanical design. While these efforts have made substantial progress, significant challenges remain in (1) building and interpreting the ML-based surrogate models and (2) iteratively and efficiently curating training datasets for optimization tasks. Here, we address the first challenge by combining ML-based surrogate modeling and Shapley additive explanation (SHAP) analysis to interpret the impact of each design variable. We find that our ML-based surrogate models achieve excellent prediction capabilities (R 2 > 0.95) and SHAP values aid in uncovering design variables influencing performance. We address the second challenge by utilizing active learning-based methods, such as Bayesian optimization, to explore the design space and report a 5 × reduction in simulations relative to grid-based search. Collectively, these results underscore the value of building intelligent design systems that leverage ML-based methods for uncovering key design variables and accelerating design.

36 MATERIALS SCIENCE↗

Global-Local Policy Search and its Application in Grid-Interactive Building Control

As the buildings sector represents over 70% of the total U.S. electricity consumption, it offers a great amount of untapped demand-side resources to tackle many critical grid-side problems and improve the overall energy system's efficiency. To help make buildings grid-interactive, this paper proposes a global-local policy search method to train a reinforcement learning (RL) based controller which optimizes building operation during both normal hours and demand response (DR) events. Experiments on a simulated five-zone commercial building demonstrate that by adding a local fine-tuning stage to the evolution strategy policy training process, the control costs can be further reduced by 7.55% in unseen testing scenarios. Baseline comparison also indicates that the learned RL controller outperforms a pragmatic linear model predictive controller (MPC), while not requiring intensive online computation.

demand response↗

Advancing Geophysical Techniques to Image a Stratigraphic Hydrothermal Resource

Sedimentary-hosted geothermal energy systems are permeable structural, structural-stratigraphic, and/or stratigraphic horizons with sufficient temperature for direct use and/or electricity generation. Sedimentary-hosted (i.e., stratigraphic) geothermal reservoirs may be present in multiple locations across the central and eastern Great Basin of the USA, thereby constituting a potentially large base of untapped, economically accessible energy resources. Sandia National Laboratories has partnered with a multi disciplinary group of collaborators to evaluate a stratigraphic system in Steptoe Valley, Nevada using both established and novel geophysical imaging techniques. The goal of this study is to inform an optimized strategy for subsequent exploration and development of this resource and analogous ones. Building from prior Nevada Play Fairway Analysis (PFA), this team is primarily 1) collecting additional geophysical data, 2) employing novel joint geophysical inversion/modeling techniques to update existing 3D geologic models, and 3) integrating the geophysical results to produce a working, geologically constrained thermo-hydrological reservoir model. Prior PFA work highlights Steptoe Valley as a favorable resource basin that likely has both sedimentary and hydrothermal characteristics. However, there remains significant uncertainty on the nature and architecture of the resource(s) at depth, which increases the risk in exploratory drilling. Newly acquired gravity, magnetic, magnetotelluric, and controlled-source electromagnetic data products, in conjunction with new and preexisting geoscientific measurements and observations, are being integrated and evaluated for efficacy in understanding stratigraphic geothermal resources and mitigating exploration risk. Furthermore, the influence of hydrothermal activity on sedimentary-hosted reservoirs in favorable structural settings, and whether fault-controlled systems may locally enhance temperature and permeability in some deep stratigraphic reservoirs, will also be evaluated.

Geothermal, Sedimentary Heat, Geophysics, Seismic,↗

Advances in genetic tools for metabolic engineering of non-conventional yeasts

Non-conventional yeasts are emerging as powerful alternatives to Saccharomyces cerevisiae for metabolic engineering, owing to their innate stress tolerance, broad substrate utilization, and distinctive metabolic capabilities. These attributes position them as promising chassis for producing biofuels, pharmaceuticals, and specialty chemicals. This review synthesizes recent advances in genetic toolkits for four such species—Pichia kudriavzevii (Issatchenkia orientalis), Starmerella bombicola, Debaryomyces hansenii, and Pachysolen tannophilus—highlighting progress across plasmid architectures (episomal and integrative), identification of autonomously replicating sequences and centromeric elements, and the development of safe-harbor genomic loci. We summarize promoter and terminator libraries enabling tunable expression, the expansion of auxotrophic and antifungal selection markers with recycling strategies, and the rapid adaptation of CRISPR-based systems (Cas9 and Cas12a) with optimized guide RNA expression, multiplex editing, and approaches that enhance homologous recombination (e.g., KU70/80 disruption). We also review landing-pad platforms for modular, repeated integrations and transposon-based tools (e.g., piggyBac) that facilitate multigene pathway assembly. Collectively, these innovations are accelerating design-build-test-learn cycles and enabling precise, scalable engineering of non-conventional yeasts. Remaining challenges—including limited species-specific episomal systems, variable transformation efficiencies, genome-stability concerns, and alternative codon usage—define clear priorities for future toolkit development. Together, these advances and open needs chart a path toward robust, sustainable biomanufacturing using diverse non-conventional yeast chassis.

59 BASIC BIOLOGICAL SCIENCES↗

Deep reinforcement learning with online data augmentation to improve sample efficiency for intelligent HVAC control

Deep Reinforcement Learning (DRL) has started showing success in real-world applications such as building energy optimization. Much of the research in this space utilized simulated environments to train RL-agent in an offline mode. Very few research have used DRL-based control in real-world systems due to two main reasons: 1) sample efficiency challenge---DRL approaches need to perform a lot of interactions with the environment to collect sufficient experiences to learn from, which is difficult in real systems, and 2) comfort or safety related constraints---user's comfort must never or at least rarely be violated. In this work, we propose a novel deep Reinforcement Learning framework with online Data Augmentation (RLDA) to address the sample efficiency challenge of real-world RL. We used a time series Generative Adversarial Network (TimeGAN) architecture as a data generator. We further evaluated the proposed RLDA framework using a case study of an intelligent HVAC control. With a ≈28% improvement in the sample efficiency, RLDA framework lays the way towards increased adoption of DRL-based intelligent control in real-world building energy management systems.

Kurte, Kuldeep↗

Dynamic analysis of fully constrained Cable-Driven Parallel Robots for automated prefabricated component installation

This paper presents a dynamic analysis and validation framework to assess a fully constrained six-anchor Cable-Driven Parallel Robot (CDPR) for automated installation of prefabricated facade components. Compared with conventional eight-anchor systems, the six-anchor configuration simplifies setup and reduces cost, but it also reduces control authority, shrinks the wrench-feasible workspace, and tightens orientation limits. Consequently, it is unclear a priori whether dynamically feasible trajectories exist to move the end effector from pickup to the facade. A constrained trajectory optimization is formulated to enforce the system dynamics, cable-tension bounds, and pose/velocity limits, and the framework is evaluated in simulation at three levels: (i) an idealized reference model, (ii) a lab-scale prototype model incorporating measured anchor misalignments and identified damping, and (iii) a full-scale three-story building model with load decomposition for structural feasibility checks. Across these scenarios, the analysis shows that optimal, constraint-satisfying trajectories exist that move the end effector from pickup to installation while maintaining a near-plumb, level orientation at the final pose. Collectively, this multi-scale dynamic analysis and validation framework supports the deployment readiness of the six-anchor CDPR and provides a prototype-based sensitivity case study of how measured anchor placement deviations affect feasibility.

CDPR↗

Geothermal Direct-Use Applications for the District Energy System in Bucharest, Romania

The city of Bucharest, Romania, hosts the second-largest district energy system (DES) in the world. Geothermal resources can be considered as a supplementary heat source to support the demand for domestic hot water and space heating in the winter and shoulder seasons. The National Laboratory of the Rockies (NLR) has conducted a study that considers geothermal energy to serve a fraction of the existing district heating network operated by Electrocentrale Bucure?ti (ELCEN), the utility operating the DES. Lower Cretaceous and Jurassic limestones make up the main geothermal aquifer underlying Bucharest, which hosts temperatures suitable for district heating (up to 90 degrees C to the north of the city). Anomalous geothermal gradients have been observed to the north of the city, where a pumped well has produced 82 degrees C brine at the wellhead to feed the Therme Bucharest Spa. An anomalous gradient has also been reported to the southeast of the city (35 degrees C/km). NLR modeled the building heating loads of a small portion of the DES (a block of nine prototypical buildings) in its Urban Renewable Building and Neighborhood Optimization (URBANopt ) platform. To simulate meeting a baseload benchmark of 20 MWth deliverable to a small portion of the DES, the NLR team used GEOPHIRES to model production scenarios for (1) hydrothermal systems coupled with heat pumps targeting the main geothermal aquifer in the north, (2) enhanced geothermal systems targeting hot dry rock in the southeast, and (3) huff-and-puff systems targeting a gradient of 25 degrees C/km. Finally, NLR conducted a high-level sensitivity study around the techno-economics of these systems. The outcomes of this work indicate that hot dry rock geothermal resources that can deliver at least 90 degrees C hot water to the Geothermal District Energy System (GeoDES) offer a possible solution for supplemental geothermal heat delivered to the existing DES.

15 GEOTHERMAL ENERGY↗

PETSc/TAO developments for GPU-based early exascale systems

The Portable Extensible Toolkit for Scientific Computation (PETSc) library provides scalable solvers for nonlinear time-dependent differential and algebraic equations and for numerical optimization via the Toolkit for Advanced Optimization (TAO). PETSc is used in dozens of scientific fields and is an important building block for many simulation codes. During the U.S. Department of Energy’s Exascale Computing Project, the PETSc team has made substantial efforts to enable efficient utilization of the massive fine-grain parallelism present within exascale compute nodes and to enable performance portability across exascale architectures. We recap some of the challenges that designers of numerical libraries face in such an endeavor, and then discuss the many developments we have made, which include the addition of new GPU backends, features supporting efficient on-device matrix assembly, better support for asynchronicity and GPU kernel concurrency, and new communication infrastructure. In conclusion, we evaluate the performance of these developments on some pre-exascale systems as well as the early exascale systems Frontier and Aurora, using compute kernel, communication layer, solver, and mini-application benchmark studies, and then close with a few observations drawn from our experiences on the tension between portable performance and other goals of numerical libraries.

Exascale Computing Project (ECP)↗

How Can Probabilistic Solar Power Forecasts Be Used to Lower Costs and Improve Reliability in Power Spot Markets? A Review and Application to Flexiramp Requirements

Net load uncertainty in electricity spot markets is rapidly growing. There are five general approaches by which system operators and market participants can use probabilistic forecasts of wind, solar, and load to help manage this uncertainty. These include operator situation awareness, resource risk hedging, reserves procurement, definition of contingencies, and explicit stochastic optimization. We review these approaches, and then provide a case study in which a method for using probabilistic solar forecasts to define needs for reserves is developed and evaluated. The case study has three parts. First, we describe building blocks for enhancing the Watt-Sun solar forecasting system to produce probabilistic irradiance and power forecasts. Second, relationships between Watt-Sun forecasts for multiple sites in California and the system's need for flexible ramp capability (flexiramp) are defined by machine learning and statistical methods. Third, the performance of present methods to defining flexiramp requirements, which are not conditioned on weather and renewables forecasts, is compared with that of probabilistic solar forecast-based requirements, using a multi-timescale production costing model with an 1820-bus representation of the WECC power system. Significant potential savings in fuel and flexiramp procurement costs from using solar-informed reserve requirements are found.

14 SOLAR ENERGY↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗