Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacity utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

System benefits of industrial battery storage: A comparison of grid and facility control and dispatch

Customer-owned, distributed battery installations are being incentivized by utilities to increase installed battery capacity. In many of these incentive agreements, the battery owner relinquishes battery control to the utility in exchange for incentive money. The industrial sector has lagged in storage installation when compared to the residential and commercial sectors. This study compares the economic advantages to utilities and industrial facilities in different dispatch control situations. The study presents a novel framework for the optimization of multiple systems using load profiles from the industrial, residential, and commercial sectors. Case studies are presented to illustrate different dispatch scenarios. Further, the simulations showed more fiscal benefit for the industrial facilities to dispatch the battery for electrical demand reduction than utility dispatch. In the case studies, facility dispatch control resulted in an increase of facility savings by a factor of about 8.7 when compared to utility dispatch. Battery size plays a significant factor on the impact of the grid’s generating costs, showing that larger batteries can provide significant benefit even if dispatched by the facility. Future policies concerning industrial battery installations should consider overall economic benefits to utility and facility in the form of rate structures and incentive participation based on battery size.

25 ENERGY STORAGE↗

Utility-Scale Solar: Empirical Trends in Project Technology, Cost, Performance, and PPA Pricing in the United States – 2018 Edition

The utility-scale solar sector has led the overall U.S. solar market in terms of installed capacity since 2012. In 2017, the utility-scale sector accounted for nearly 60% of all new solar capacity, and is expected to maintain its market-leading position for at least another six years. Two-thirds of all states, representing all regions of the country, are now home to one or more utility-scale solar projects. This report—the sixth in an ongoing annual series—provides in-depth data-driven analysis of the utility-scale solar project fleet in the United States. Drawing on empirical project-level data from a wide range of sources, this report analyzes technology trends, installed project prices, operating costs, capacity factors, power purchase agreement ("PPA") prices, the levelized cost of solar energy (LCOE), and the market value of solar. Given its current preeminence in the market, utility-scale PV also dominates much of this report, though data from CPV and CSP projects are also presented where appropriate. Highlights from this year's edition include: -Installation and Technology Trends: The use of solar trackers dominated 2017 installations with nearly 80% of all new capacity. In a reflection of the ongoing geographic expansion of the market beyond California and the high-insolation Southwest, the median insolation level at newly built project sites declined again in 2017. While new fixed-tilt projects are now seen predominantly in less-sunny regions, tracking projects are increasingly pushing into these same regions. The median inverter loading ratio grew to 1.32 in 2017, allowing the inverters to operate closer to full capacity for a greater percentage of the day. -Installed Prices: Median installed PV project prices have steadily fallen by two-thirds since the 2007-2009 period, to $2.0/WAC (or $1.6/WDC) for projects completed in 2017. The lowest 20th percentile of projects within our 2017 sample were priced at or below $1.8/WAC, with the lowest-priced projects around $0.9/WAC. Overall price dispersion across the entire sample has decreased steadily every year since 2013; similarly, price variation across regions decreased in 2017. -Operation and Maintenance ("O&M") Costs: PV O&M costs were in the neighborhood of $16/kWAC-year, or $8/MWh, in 2017. These numbers include only those costs incurred to directly operate and maintain the generating plant. -Capacity Factors: The cumulative net AC capacity factors of individual projects vary widely, from 14.3% to 35.2%, with a sample median of 26.3%. This project-level variation is based on a number of factors, including the strength of the solar resource at the project site, whether the array is mounted at a fixed tilt or on a tracking mechanism, the inverter loading ratio, degradation, and curtailment. Changes in at least the first three of these factors drove mean capacity factors higher from 2010-vintage to 2013-vintage projects, where they've remained fairly steady among more-recent project vintages as an ongoing increase in the prevalence of tracking has been offset by a build-out of lower resource sites. -PPA Prices and LCOE: Driven by lower installed project prices and improving capacity factors, levelized PPA prices for utility-scale PV have fallen dramatically over time, by $20-$30/MWh per year on average from 2006 through 2012, with a smaller price decline of ~$10/MWh per year evident from 2013 through 2016. Most recent PPAs in our sample—including many outside of California and the Southwest—are priced at or below $40/MWh levelized (in real 2017 dollars), with a few priced as aggressively as ~$20/MWh. The median LCOE among operational PV projects in our sample has followed PPA prices lower, suggesting a relatively competitive market for PPAs. -Solar's Wholesale Energy Market Value: Falling PPA prices have been offset to some degree by a decline in the wholesale energy market value of solar within higher-penetration markets like California, where solar earned just 79% of the average price across all hours within CAISO's real-time wholesale energy market in 2017 (down from 125% back in 2012). In other markets with less solar penetration, however, solar's hourly generation profile still earns more than the average wholesale price (e.g., 127% in ERCOT, 112% in PJM). -Solar+Storage: Adding battery storage is one way to at least partially restore the value of solar, and three recent PV+storage PPAs in Nevada (each using 4-hour batteries sized at 25% of PV nameplate capacity) suggest that the incremental PPA price adder for storage has fallen to ~$5/MWh, down from ~$15/MWh just a year ago for a similarly configured project. As PV plus battery storage becomes more cost-effective, a number of developers are regularly offering it as a viable upgrade to standalone PV. At the end of 2017, there were at least 188.5 GW of utility-scale solar power capacity within the interconnection queues across the nation. The 2017 growth within these queues is widely distributed across all regions of the country, but is most pronounced in the up-and-coming Midwest region, which accounts for 27% of the 99.2 GW of new queue capacity. The widening geographic distribution is as clear of a sign as any that the utility-scale market is maturing and expanding outside of its traditional high-insolation comfort zones.

14 SOLAR ENERGY↗

Systems and methods of preparing lithium sulfur electrode using sacrificial template

Embodiments described herein relate generally to lithium sulfur batteries and methods of producing the same. As described herein, preventing coarsening of sulfur during the well-known melt-diffusion processing of cathodes allows a high areal capacity of 10.7 mAh/cm2 at current density of 3.4 mA/cm2 (C-rate of 1/5 h−1). The addition of a lithium salt, such as LiTFSI, prior to melt-diffusion can prevent coarsening of molten sulfur and allows creation of a sulfur electrode with a high concentration of triple-phase junctions for electrochemical reaction. In some embodiments, approximately 60-70% utilization of the theoretical capacity of sulfur is reached at a high loading (e.g., greater than 7.5 mg S/cm2). The electrodes are prepared in lean-electrolyte environment of 3 mlelectrolyte/gsulfur (˜70 vol % of electrolyte in the electrode) for high areal capacity in Li—S batteries.

Chen, Xinwei↗

Automated Demand Response: The Missing Link in the Electricity Value Chain

In 2006, the Public Interest Energy Research Program (PIER) Demand Response Research Center (DRRC) at Lawrence Berkeley National Laboratory initiated research into Automated Demand Response (OpenADR) applications in California industry. The goal is to improve electric grid reliability and lower electricity use during periods of peak demand. The purpose of this research is to begin to define the relationship among a portfolio of actions that industrial facilities can undertake relative to their electricity use. This 'electricity value chain' defines energy management and demand response (DR) at six levels of service, distinguished by the magnitude, type, and rapidity of response. One element in the electricity supply chain is OpenADR, an open-standards based communications system to send signals to customers to allow them to manage their electric demand in response to supply conditions, such as prices or reliability, through a set of standard, open communications. Initial DRRC research suggests that industrial facilities that have undertaken energy efficiency measures are probably more, not less, likely to initiate other actions within this value chain such as daily load management and demand response. Moreover, OpenADR appears to afford some facilities the opportunity to develop the supporting control structure and to 'demo' potential reductions in energy use that can later be applied to either more effective load management or a permanent reduction in use via energy efficiency. Under the right conditions, some types of industrial facilities can shift or shed loads, without any, or minimal disruption to operations, to protect their energy supply reliability and to take advantage of financial incentives. In 2007 and 2008, 35 industrial facilities agreed to implement OpenADR, representing a total capacity of nearly 40 MW. This paper describes how integrated or centralized demand management and system-level network controls are linked to OpenADR systems. Case studies of refrigerated warehouses and wastewater treatment facilities are used to illustrate OpenADR load reduction potential. Typical shed and shift strategies include: turning off or operating compressors, aerator blowers and pumps at reduced capacity, increasing temperature set-points or pre-cooling cold storage areas and over-oxygenating stored wastewater prior to a DR event. This study concludes that understanding industrial end-use processes and control capabilities is a key to support reduced service during DR events and these capabilities, if DR enabled, hold significant promise in reducing the electricity demand of the industrial sector during utility peak periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of predicted mean vote-based model predictive control for residential HVAC systems

Model Predictive Control (MPC) is an advanced process control method that has attracted much attention in building heating, ventilation, and air conditioning (HVAC) systems. Here, this paper analyzes the optimal precooling performance in residential buildings using MPC with two different comfort indices, namely, temperature and predicted mean vote (PMV). It first formulates, for each comfort index, an optimization problem that accounts for different factors, such as weather, home thermal condition, prediction horizon, time-of use (TOU) utility rate, and rated cooling capacity. The problem is then solved, resulting in an MPC strategy that determines the HVAC on/off control signal and minimizes energy cost over a receding time horizon while maintaining thermal comfort. The energy performance difference between temperature-based and PMV-based MPC strategies is subsequently investigated, especially in light of the interior wall surface temperature and under different combinations of the factors. Extensive simulation results demonstrated that the proposed MPC strategies are adaptive and their performances depend primarily on weather, home thermal condition, and prediction horizon, while the impact of TOU utility rate and rated cooling capacity is relatively small. Because the PMV-based MPC strategy can take advantage of the lower interior wall surface temperature due to precooling, it resulted in 8–45% cost savings for the scenarios investigated and an average increase of 0.042–0.113 in the absolute value of the PMV index compared to the temperature-based MPC strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Kenya Food Security & Agriculture II: Utilizing NASA Earth Observations to Enhance Drought Warning Systems and Develop Capacity to Use the RHEAS Model in Kenya

Twenty-three counties in Kenya experience frequent drought, which damages agricultural productivity and threatens the health and well being of millions. NASA DEVELOP partnered with NASA SERVIR, the Regional Centre for Mapping of Resources for Development (RCMRD) and Kenya’s National Drought Management Authority (NDMA) to enhance drought-detection capacity using NASA Earth observations. Currently, the NDMA publishes monthly Early Warning Bulletins with drought conditions for each arid or semi-arid county in Kenya. These bulletins utilize the Vegetation Condition Index (VCI) from the Moderate Resolution ImagingSpectroradiometer (MODIS) as well as a variety of biophysical, social and economic drought indicators, but do not allow for advanced forecasting. To improve drought-monitoring capabilities, the team created a Combined Drought Indicator (CDI) using the Regional Hydrologic Extremes Assessment System (RHEAS) model and data from Aqua and Terra MODIS and the National Centers for Environmental Prediction. The CDI combined precipitation anomalies, soil moisture anomalies, evaporative stress, and VCI according to weights determined by principal component analysis. To evaluate the performance of the CDI across Kenya, the team compiled a dataset of drought events from historical reports and the NDMA’s records. Results suggested that the CDI detected drought earlier thanVCI alone. However, more validation is needed to ensure that the CDI accurately and consistently detects drought earlier than current warning systems. In order to better understand the behavior of individual indices and the potential for earlier drought detection, the team also conducted a time-lag analysis. The team found that VCI responds to drought, on average, one month later than most other indices included in the CDI, suggesting that incorporating additional indices could improve early drought warning systems in Kenya.

Food Security & Agriculture↗

Kenya Food Security & Agriculture II: Utilizing NASA Earth Observations to Enhance Drought Warning Systems and Develop Capacity to Use the RHEAS Model in Kenya

Twenty-three counties in Kenya experience frequent drought, which damages agricultural productivity and threatens the health and well being of millions. NASA DEVELOP partnered with NASA SERVIR, the Regional Centre for Mapping of Resources for Development (RCMRD) and Kenya’s National Drought Management Authority (NDMA) to enhance drought-detection capacity using NASA Earth observations. Currently, the NDMA publishes monthly Early Warning Bulletins with drought conditions for each arid or semi-arid county in Kenya. These bulletins utilize the Vegetation Condition Index (VCI) from the Moderate Resolution Imaging Spectroradiometer (MODIS) as well as a variety of biophysical, social and economic drought indicators, but do not allow for advanced forecasting. To improve drought-monitoring capabilities, the team created a Combined Drought Indicator (CDI) using the Regional Hydrologic Extremes Assessment System (RHEAS) model and data from Aqua and Terra MODIS and the National Centers for Environmental Prediction.The CDI combined precipitation anomalies, soil moisture anomalies, evaporative stress, and VCI according to weights determined by principal component analysis. To evaluate the performance of the CDI across Kenya, the team compiled a dataset of drought events from historical reports and the NDMA’s records. Results suggested that the CDI detected drought earlier than VCI alone. However, more validation is needed to ensure that the CDI accurately and consistently detects drought earlier than current warning systems. In order to better understand the behavior of individual indices and the potential for earlier drought detection, the team also conducted a time-lag analysis. The team found that VCI responds to drought, on average, one month later than most other indices included in the CDI, suggesting that incorporating additional indices could improve early drought warning systems in Kenya.

Food Security & Agriculture↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design Considerations for Phase Change Material-Incorporated Heat Exchangers in Water Heating

In recent years, the buildings sector has seen major pushes towards decarbonization through innovations that promote deep electrification. 20% of an average household's energy use comes from water heating, and in the US, over half of all households still use gas water heaters. Of those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. However, HPWHs tend to have larger dimensions, preventing current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). This study outlines the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. To ensure optimal PCM utilization and tank storage capacity, this works seeks to co-maximize surface area and PCM volume; therefore, this research targets triply periodic minimal surface (TPMS) lattices, which boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives. Our current results indicate that tuning lattice properties can effectively produce geometries that provide enough energy storage to achieve a 50-gallon capacity out of a 40-gallon HPWH, even when placing the PCM heat exchanger inside the tank. Additionally, we demonstrate successful fabrication of lattices with these tuned properties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Canada-U.S. Power Sector Modeling with the Regional Energy Deployment System (ReEDS)

The electric power system in North America is linked between the United States and Canada. Canada has historically been a net exporter of electricity to the United States. The extent to which this remains true will depend on the future evolution of power markets, technology deployment, and policies. To evaluate these and related questions, we modify the Regional Energy Deployment System (ReEDS) model to include an explicit representation of the grid-connected power system in Canada to the continental United States. ReEDS is unique among long-term capacity expansion models for its high spatial resolution and statistical treatment of the impact of variable renewable generation on capacity planning and dispatch. These unique traits are extended to new Canadian regions. We present example scenario results using the fully integrated Canada-U.S. version of ReEDS to demonstrate model capabilities. The newly developed, integrated Canada-U.S. ReEDS model can be used to analyze the dynamics of electricity transfers and other grid services between the two countries under different scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Complete Iodine Loading of NO-Aged Ag 0 -Functionalized Silica Aerogel (Milestone Report)

In off-gas treatment systems within a nuclear fuel reprocessing plant, capture materials will be exposed to a gas stream for extended periods during their lifetime. This gas stream may be at elevated temperature and could contain water, NO x gas, or a variety of other constituents. For this reason, it is important to understand the effects of long-term exposure, or aging, on proposed capture materials. One material under consideration for iodine sequestration is silver-functionalized silica aerogel (Ag 0 -aerogel). The aim of this study was to determine the effect of extended exposure at 150°C to an air stream containing NO on the iodine capture capacity of Ag 0 -aerogel. Ag 0 -aerogel was provided by the Pacific Northwest National Laboratory (PNNL), which manufactures the material at a lab scale. Prior to aging, the material has an iodine loading capacity of approximately 290 mg I/g Ag 0 -aerogel. Previous studies have aged the material in a dry air stream or in a moist air stream for up to 6 months. Both tests resulted in a 22% loss in iodine capacity. Aging the material in a static 2% NO 2 environment for up to 2 months results in a 15% loss of iodine capacity.3 In this study, exposure of Ag 0 -aerogel to 1% NO at 150°C for 2 months produced a loss of 43% in iodine loading capacity. This is largest loss observed for aerogel aging studies to date. The performance of Ag 0 -aerogel in this study was compared to the performance of reduced silver mordenite (Ag 0 Z) in similar studies. Ag 0 Z is a zeolite mineral considered to be the current standard technology for iodine removal from off-gas streams of a potential US used fuel processing plant. In an aging study exposing Ag 0 Z to 1% NO for 2 months, an iodine capacity loss of over 80% was observed. This corresponds to a silver utilization of 13.5% for 2 month NO-aged Ag 0 Z, compared to 57% silver utilization for 2 month NO-aged aerogel. While iodine loading capacity and silver utilization are critical parameters in evaluating these materials, other properties must also be considered when selecting the appropriate material (e.g., relative material densities and potential waste form production technology). The resistance of Ag 0 -aerogel to NO is promising, and investigations of this material for use in iodine capture should continue to be pursued.

36 MATERIALS SCIENCE↗

Investment and Upgrade in Distributed Generation under Uncertainty

The ongoing deregulation of electricity industries worldwide is providing incentives for microgrids to use small-scale distributed generation (DG) and combined heat and power (CHP) applications via heat exchangers (HXs) to meet local energy loads. Although the electric-only efficiency of DG is lower than that of central-station production, relatively high tariff rates and the potential for CHP applications increase the attraction of on-site generation. Nevertheless, a microgrid contemplatingthe installation of gas-fired DG has to be aware of the uncertainty in the natural gas price. Treatment of uncertainty via real options increases the value of the investment opportunity, which then delays the adoption decision as the opportunity cost of exercising the investment option increases as well. In this paper, we take the perspective of a microgrid that can proceed in a sequential manner with DG capacity and HX investment in order to reduce its exposure to risk from natural gas price volatility. In particular, with the availability of the HX, the microgrid faces a tradeoff between reducing its exposure to the natural gas price and maximising its cost savings. By varying the volatility parameter, we find that the microgrid prefers a direct investment strategy for low levels of volatility and a sequential one for higher levels of volatility.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Policies to Spur Energy Access. Executive Summary; Volume 1, Engaging the Private Sector in Expanding Access to Electricity; Volume 2, Case Studies to Public-Private Models to Finance Decentralized Electricity Access

Government policy is one of the most important factors in engaging the private sector in providing universal access to electricity. In particular, the private sector is well positioned to provide decentralized electricity products and services. While policy uncertainty and regulatory barriers can keep enterprises and investors from engaging in the market, targeted policies can create opportunities to leverage private investment and skills to expand electricity access. However, creating a sustainable market requires policies beyond traditional electricity regulation. The report reviews the range of policy issues that impact the development and expansion of a market for decentralized electricity services from establishing an enabling policy environment to catalyzing finance, building human capacity, and integrating energy access with development programs. The case studies in this report show that robust policy frameworks--addressing a wide range of market issues--can lead to rapid transformation in energy access. The report highlights examples of these policies in action Bangladesh, Ethiopia, Mali, Mexico, and Nepal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Failure Mechanism of Fast-Charged Lithium Metal Batteries in Liquid Electrolyte

In recent years, lithium anode has re-attracted broad interest because of the necessity of employing lithium metal in the next-generation battery technologies such as lithium sulfur (Li-S) and lithium oxygen (Li-O2) batteries. Fast capacity degradation and safety issue associated with rechargeable lithium metal batteries have been reported, although the fundamental understanding on the failure mechanism of lithium metal at high charge rate is still under debate due to the complicated interfacial chemistry between lithium metal and electrolyte. Herein, we demonstrate that, at high current density, the quick growth of porous solid electrolyte interphase towards bulk lithium, instead of towards the separator, dramatically builds up the cell impedance that directly leads to the cell failure. Understanding the lithium metal failure mechanism is very critical to gauge the various approaches used to address the stability and safety issues associated with lithium metal anode. Otherwise, all cells will fail quickly at high rates before the observation of any positive effects that might be brought from adopting the new strategies to protect lithium.

Environmental Molecular Sciences Laboratory↗

Influence of Sodium Silicate/Sodium Alginate Additives on Discharge Performance of Mg–Air Battery Based on AZ61 Alloy

The application of Mg–air batteries is limited due to passivation and self-corrosion of anode alloys in electrolyte. In effort of solving this problem, the present work studied the influence of sodium silicate (SS)/sodium alginate (SA) on electrochemical behaviors of AZ61 alloy in NaCl solution by circle potentiodynamic polarization and galvanostatic discharge. The corrosion morphology and discharge product were examined by scanning electron microscopy (SEM) and x-ray diffraction (XRD). Results have shown that sodium silicate/sodium alginate inhibitors have an apparent effect on the self-corrosion of AZ61 alloy without affecting its discharge performance. The discharge capacity and the anodic utilization for Mg–air battery in a 0.6 M NaCl + 0.01 M SS +0.04 M SA solution are measured to be 1397 mAhg{sup −1} and 48.2%, respectively. Electrochemical impedance spectroscopy (EIS) and SEM investigation have confirmed that the sodium silicate/sodium alginate inhibitor can obviously decrease the self-corrosion of AZ61 alloy. SEM and XRD diffraction examinations suggest that the inhibiting mechanism is due to the formation of a compact and “cracked mud” layer. AZ61 alloy can be used as the anode for Mg–air battery in a solution of 0.6 M NaCl + 0.01 M SS +0.04 M SA.

36 MATERIALS SCIENCE↗

Battery Energy Storage Systems Report

Battery energy storage systems (BESS) are a critical component of grid reliability and resilience today, providing rapid response capabilities while enabling grid modernization and capacity expansion across the United States. As utilities, communities, and customers prepare to deploy significant BESS capacity over the next several years, the United States has an opportunity to build security into battery system design and deployments. This report provides a framework for assessing the current dominance of foreign-manufactured components in the supply chains for BESS, inverter-based resources, and transformers. It offers high-impact, actionable solutions to service partners, industry, and government to address supply chain risks for currently installed, in design, and future deployments.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Optimal Strategies for Hybrid Battery‐Storage Systems Design

As stationary hybrid energy‐storage systems (HESS) for power systems applications have recently drawn interest due to their enhanced performance and decreasing cost, developing systematic approaches for HESS design while considering controls is gaining traction. Herein, a method is presented to optimally design hybrid battery storage by proposing a mathematical modeling framework, formulated as a mixed integer linear programming model. The optimization is capable of handling multiple subsystems of batteries, considering their economic and technological performance. Decisions involve sizing of the batteries, optimal temporal and strategic dispatch to end uses, and energy sources for charging each battery. The applicability of the model is tested on four case studies for three battery chemistries representing distinct objectives: high‐power, high‐energy, and second life. Compared to traditionally designed battery storage with a homogeneous battery, optimally designed hybrid systems can save 12%–26% of system costs, depending on the nature of the dispatch profile. Findings point to design preference toward the second life battery supplemented with some high‐power or high‐energy battery capacity, or both. With the utilized electricity price structure, customers can experience approximately 10%–35% reduction in their bills.

Koleva, Mariya↗