Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold temperatures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Flame quenching by a variable-width rectangular-slot burner as a function of pressure for various propane-oxygen-nitrogen mixtures

Flame quenching by a variable-width rectangular-slot burner as a function of pressure for various propane-oxygen-nitrogen mixtures was investigated. It was found that for cold gas temperatures of 27 degrees C, pressures of 0.1 ro 1.0 atmosphere, and volumetric oxygen reactions of the oxidant of 0.17, 0.21, 0.30, 0.50, and 0.70, the relation between pressure p and quenching distance d is approximately given by d (unity) p (superscript -r) with r = 1, for equivalence ratios approximately equal to one. The quenching equation of Simon and Belles was tested. For equivalence ratios less than or equal to unity, this equation may by used, together with one empirical constant, to predict the observed quenching distance within 4.2 percent. The equation in it's present form does not appear to be suitable for values of the equivalence ratio greater than unity. A quantitative theoretical investigation has also been made of the error implicit in the assumption that flame quenching by plane parallel plates of infinite extent is equivalent to that of a rectangular burner. A curve is presented which relates the magnitude of this error to the length-to-width ratio of the rectangular burner.

COMBUSTION RESEARCH↗

Boundary conditions for the paleoenvironment: Chemical and physical processes in the pre-solar nebula

In observations with the NRAO 12m telescope at Kitt Peak, Arizona, Irvine, a new interstellar radical, CH2N, has been detected. This identification is important for the study of hydrogenation processes in the interstellar medium. In particular, although the abundance of hydrogen is some four orders of magnitude higher than that of other reactive elements in this environment, many organic molecules in quiescent clouds are very unsaturated. This is a consequence of activation barriers which cannot be overcome at the temperatures of cold clouds, even when such reactions are energetically allowed. The hydrogenation series based on the cyanide radical (HnCN) has had four members previously detected in the interstellar medium: CN (n equals O), HCN (n equals l), CH2CN (n equals 3), and CH3NH2 (n equals 5). The recent determination of the rotational spectrum of the CH2N radical through microwave spectroscopy in Japan has made possible a search for this species. In addition to its potential importance for interstellar chemistry, the CH2N radical has been proposed as a reaction intermediate for HCN production in the atmosphere of Jupiter, and as a possible species in the expanding envelopes of oxygen--rich evolved stars. We detected CH2N in the cold cloud TMC--1 where the abundance seems to be some three orders of magnitude lower than that of HCN. A tentative detection was made in the Galactic Center molecular cloud Sgr B2. To our knowledge, there are no predicted abundances of CH2N from models of interstellar chemistry.

Irvine, William M.↗

Feasibility of detecting aircraft wake vortices using passive microwave radiometers

The feasibility of detecting the cold core of the wake vortex from the wingtips of an aircraft using a passive microwave radiometer was investigated. It was determined that there is a possibility that a cold core whose physical temperature drop is 10 C or greater and which has a diameter of 5 m or greater can be detected by a microwave radiometer. The radiometer would be a noise injection balanced Dicke radiometer operating at a center frequency of 60 GHz. It would require a noise figure of 5 dB, a predetection bandwidth of 6 GHz, and an integration time of 2 seconds resulting in a radiometric sensitivity of 0.018 K. However, three additional studies are required. The first would determine what are the fluctuations in the radiometric antenna temperature due to short-term fluctuations in atmospheric pressure, temperature, and relative humidity. Second, what is the effect of the pressure and temperature drop within the cold core of the wake vortex on its opacity. The third area concerns the possibility of developing a 60 GHz radiometer with a radio metric sensitivity an order of magnitude improvement over the existing state of the art.

Harrington, Richard F.↗

Constraints on molecular gas in cooling flows and powerful radio galaxies

We searched for molecular gas in a heterogeneous sample of five radio-loud galaxies (three of which are inferred to be in cooling flow clusters) using the Swedish-European Southern Observatory (Swedish-ESO) Submillimeter Telescope. We do not detect CO in emission in any of the cluster sources at a 3 sigma level of typically 15 mK. White et al. (1991) have suggested column densities of N(sub H) approximately 10(exp 21)/sq cm in these clusters with a spatial covering factor of order unity and a total mass of M approximately 10(exp 12) solar mass. Our limits are inconsistent with these column densities and spatial covering factor unless the molecular gas is very cold (kinetic temperature close to 2.7 K) or there only a few clouds along each line of sight. We estimate minimum temperatures in the range approximately 20-30 K. We find that clouds of atomic and molecular hydrogen require strict fine-tuning of parameter space in order to satisfy the requirements for the large column densities N(sub H) approximately 10(exp 21)/sq cm, unit covering factor, and a small number of clouds along the line of sight. Currently the only way molecular gas can be responsible for the X-ray absorption and still be consistent with our observations is if (1) there is of order one cloud along the line of sight and (2) the optical depth in C-12 1 to 0 is less than 10. In addition, we present a Very Large Array (VLA) image of NGC 4696 which suggests this object is a member of the class of 'amorphous cooling flow radio sources.' The C-12 1 to 0 line is detected in emission in PKS 0634-206, a classical double radio galaxy which is rich in extended optical emission line gas. The estimated molecular gas mass is M(sub mol) approximately 3 x 10(exp 9) solar mass and is much larger than that of the ionized component detected in hydrogen alpha suggesting that the emission-line nebula is radiation bounded.

O'Dea, Christopher P.↗

NCAR CCM2 simulation of the modern Antarctic climate

The National Center for Atmospheric Research (NCAR) community climate model version 2 (CCM2) simulation of the circumpolar trough, surface air temperature, the polar vortex, cloudiness, winds, and atmospheric moisture and energy budgets are examined to validate the model's representation of the present-day Antarctic climate. The results show that the CCM2 can well simulate many important climate features over Antarctica, such as the location and intensity of the circumpolar trough, the coreless winter over the plateau, the intensity and horizontal distribution of the surface inversion, the speed and streamline pattern of the katabatic winds, the double jet stream feature over the southern Indian and Pacific oceans, and the arid climate over the continent. However, there are also some serious errors in the model. Some are due to old problems but some are caused by the new parameterizations in the model. The model errors over high southern latitudes can be summarized as follows: The circumpolar trough, the polar vertex, and the westerlies in midlatitudes are too strong; the semiannual cycle of the circumpolar trough is distorted compared to the observations; the low centers of the circumpolar trough and the troughs in the middle and upper troposphere are shifted eastward by 15 deg - 40 deg longitude; the surface temperatures are too cold over the plateau in summer and over the coastline in winter; the polar tropopause continues to have a cold bias; and the cloudiness is too high over the continent. These biases are induced by two major factors: (1) the cloud optical properties in tropical and middle latitudes, which cause the eastward shift of troughs and surface low centers and the error in the semiannual cycle, and (2) the cold bias of the surface air temperature, which is attributed to the oversimulation of cloudiness over the continent, especially during summer, and the uniform 2-m-thick sea ice. The constant thickness of sea ice suppresses the energy flux from the ocean to the atmosphere and hence reduces the air temperature near the coast during winter. Finally, although the simulated Antarctic climate still suffers these biases, the overall performance of the CCM2 is much better than that of the CCM1-T42. Therefore the CCM2 is good enough to be used for climate change studies, especially over Antarctica.

Tzeng, Ren-Yow↗

On quasi-thermal fluctuations near the plasma frequency in the outer plasmasphere: A case study

We present a derivation of the quasi-thermal electrostatic fluctuation power spectrum in a mult-Maxwellian plasma and show sample calculated spectra. We then apply this theory, which has been successfully applied in oter regions of space, to spectra from two Active Magnetospheric Particle Tracer Explorer/Ion Release Module (AMPTER IRM) passes through the duskside plasmasphere. WE show that the plasma line that is often seen in this region is usually quasi-thermal in origin. We obtain a refined estimate of the plasma frequency and infer a cold electron temperature which is consistent within a factor of 2 with both models and previous meausurements by other techniques, but closer investigation reveals that details of the plasma line cannot be explained with the ususal two isotropic Maxwellian model.

Lund, E. J.↗

High-voltage space-plasma interactions measured on the PASP Plus test arrays

The Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) experiment was developed by the Air Force's Phillips Laboratory with support from NASA's Lewis Research Center. It was launched on the Advanced Photovoltaic and Electronics EXperiments (APEX) satellite on August 3, 1994 into a 70 degree inclination, 363 km by 2550 km elliptical orbit. This orbit allows the investigation of space plasma effects on high-voltage operation (leakage current at positive voltages and arcing at negative voltages) in the perigee region. PASP Plus is testing twelve solar arrays. There are four planar Si arrays: an old standard type (used as a reference), the large-cell Space Station Freedom (SSF) array, a thin 'APSA' array, and an amorphous Si array. Next are three GaAs on Ge planar arrays and three new material planar arrays, including InP and two multijunction types. Finally, there are two concentrator arrays: a reflective-focusing Mini-Cassegrainian and a Fresnel-lens focusing Mini-Dome. PASP Plus's diagnostic sensors include: Langmuir probe to measure plasma density, an electrostatic analyzer (ESA) to measure the 30 eV to 30 KeV electron/ion spectra and determine vehicle negative potential during positive biasing, and a transient pulse monitor (TPM) to characterize the arcs that occur during the negative biasing. Through positive biasing of its test arrays, PASP Plus investigated the snapover phenomenon, which took place over the range of +100 to +300 V. It was found that array configurations where the interconnects are shielded from the space plasma (i.e., the concentrators or arrays with 'wrap-through' connectors) have lower leakage current. The concentrators exhibited negligible leakage current over the whole range up to +500 V. In the case of two similar GaAs on Ge arrays, the one with 'wrap-through' connectors had lower leakage current than the one with conventional interconnects. Through negative biasing, PASP Plus investigated the arcing rates of its test arrays. The standard Si array, with its old construction (exposed rough-surface interconnects), arced significantly over a wide voltage and plasma-density range. The other arrays arced at very low rates, mostly at voltages greater than -350 V and plasma densities near or greater than 10(exp 5)/cm(exp -3). AS expected according to theory, arcing was more prevalent when array temperatures were cold (based on biasing in eclipse).

Guidice, Donald A.↗

Automatic Jet Contrail Detection and Segmentation

Jet contrails are an important subset of cirrus clouds in the atmosphere, and thin cirrus are thought to enhance the greenhouse effect due to their semi-transparent nature. They are nearly transparent to the solar energy reaching the surface, but they reduce the planetary emission to space due to their cold ambient temperatures. Having 'seeded' the environment, contrails often elongate and widen into cirrus-like features. However, there is great uncertainty regarding the impact of contrails on surface temperature and precipitation. With increasing numbers of subsonic aircraft operating in the upper troposphere, there is the possibility of increasing cloudiness which could lead to changes in the radiation balance. Automatic detection and seg- mentation of jet contrails in satellite imagery is important because (1) it is impractical to compile a contrail climatology by hand, and (2) with the segmented images it will be possible to retrieve contrail physical properties such as optical thickness, effective ice crystal diameter and emissivity.

Weiss, J.↗

Design Models for the Development of Helium-Carbon Sorption Crycoolers

We have developed models for predicting the performance of helium-based Joule-Thomson continuous-flow cryocoolers using charcoal-pumped sorption compressors. The models take as inputs the number of compressors, desired heat-lift, cold tip temperature, and available precooling temperature and provide design parameters as outputs. Future laboratory development will be used to verify and improve the models. We will present a preliminary design for a two-stage vibration-free cryocooler that is being proposed as part of a mid-infrared camera on NASA's Next Generation Space Telescope. Model predictions show that a 10 mW helium-carbon cryocooler with a base temperature of 5.5 K will reject less than 650 mW at 18 K. The total input power to the helium-carbon stage is 650 mW. These models, which run in MathCad and Microsoft Excel, can be coupled to similar models for hydrogen sorption coolers to give designs for 2-stage vibration-free cryocoolers that provide cooling from approx. 50 K to 4 K.

Lindensmith, C. A.↗

Design Models for the Development of Helium-Carbon Sorption Cryocoolers

We have developed models for predicting the performance of helium-based Joule-Thomson continuous-flow cryocoolers using charcoal-pumped sorption compressors. The models take as inputs the number of compressors, desired heat-lift, cold tip temperature, and available precooling temperature and provide design parameters as outputs. Future laboratory development will be used to verify and improve the models. We will present a preliminary design for a two-stage vibration-free cryocooler that is being proposed as part of a mid-infrared camera on NASA's Next Generation Space Telescope. Model predictions show that a 10 mW helium-carbon cryocooler with a base temperature of 5.5 K will reject less than 650 mW at 18 K. The total input power to the helium-carbon stage is 650 mW. These models, which run in MathCad and Microsoft Excel, can be coupled to similar models for hydrogen sorption coolers to give designs for 2-stage vibration-free cryocoolers that provide cooling from approximately 50 K to 4 K.

Lindensmith, Chris A.↗

Macroscopic Relationships among Latent Heating, Precipitation, Organized Convection and the Environment

Three-dimensional Cloud Resolving Model (CRM) simulations were conducted to examine the squall line observed on 26 January, 1999 from the Tropical Rainfall Measuring Mission Large Scale Biosphere Atmosphere Experiment in Amazonia (TRMM-LBA) field campaign. The computational domain was 600 kilometers x 180 kilometers x 20 kilometers with a horizontal resolution of 1 kilometer and a vertical resolution of 200 meters. The CRM was initialized from the Abracos Hill and Rebio soundings. Convection was initiated by a surface-based and NW-SE oriented cold pool over a region 60 kilometers in the y-direction and 30 kilometers wide in the x-direction. The cold pool temperature perturbation is a maximum of -6K at the surface, decreasing linearly to zero at 3 kilometers. The simulated convection is in the form of a NW-SE band that moves toward the southwest at a speed of 8 meters per second, and is generally comparable to radar observations.

Moncrieff, Mitchell W.↗

Thermal-Structural Analysis of Sunshield Membranes

Future large infrared space telescopes, such as the James Webb Space Telescope (JWST), will require deployable sunshields to provide passive cooling for optics and instruments. Deployable sunshield structures for such applications typically consist of multiple thin-film membrane layers supported by deployable booms. The mechanical design of the sunshield must accommodate thermal strains due to layer-to-layer temperature differences as well as potentially large in-plane temperature gradients within individual film layers. This paper describes a thermal-structural analysis for predicting the stress state in a thin-film membrane subject to both mechanical thermal loads that could aid in the mechanical design of future sunshield structures. First the temperature field predicted by a thermal analysis is mapped to a structural finite element model, and then the structural response is predicted using a nonlinear static analysis. The structural model uses membrane elements in conjunction with a tension field material model to predict the response of the thin-film membrane layer. The tension field material model accounts for no-compression behavior associated with wrinkling and slackness. This approach was used to study the problem of a single membrane layer from the NASA reference concept for the JWST sunshield. Results from the analysis show that the membrane can experience a loss of tensile preload due to the presence of an in-plane temperature gradient representative of the cold-side layer temperature distribution predicted for the reference concept JWST.

Johnston, John↗

Effect of gravity opientation on the thermal performance of Stirling-type pulse tube cryocoolers

This paper extends the investigation of angular orientation effects to the refrigeration performance of high frequency (-40 Hz) Stirling-type pulse tube cryocoolers typical of those used in long-life space applications. Strong orientation effects on the performance of such cryocoolers have recently been observed during system-level testing of both linear and U-tube type pulse tubes. To quantify the angular dependency effects, data have been gathered on both U-tube and linear type pulse tubes of two different manufacturers as a function of orientation angle, cold-tip temperature, and compressor stroke.

angular dependency↗

Space Suit Radiator Performance in Lunar and Mars Environments

During an ExtraVehicular Activity (EVA), both the heat generated by the astronaut's metabolism and that produced by the Portable Life Support System (PLSS) must be rejected to space. The heat sources include the heat of adsorption of metabolic CO2, the heat of condensation of water, the heat removed from the body by the liquid cooling garment and the load from the electrical components. Although the sublimator hardware to reject this load weighs only 3.48 lbs, an additional eight pounds of water are loaded into the unit of which about six to eight are sublimated and lost; this is the single largest expendable during an eight-hour EVA. Using a radiator to reject heat from the Astronaut during an EVA, we can significantly reduce the amount of expendable water consumed by the sublimator. Last year we reported on the design and initial operational assessment tests of our novel radiator designated the Radiator And Freeze Tolerant heat eXchanger (RAFT-X). Herein, we report on tests conducted in the NASA Johnson Space Center Chamber E Thermal Vacuum Test Facility. Up to 800 Btu/h of heat were rejected in lunar and Mars environments with temperatures as cold as -150 F. Tilting the radiator did not cause an observable loss in performance. The RAFT-X endured freeze / thaw cycles and in fact, the heat exchanger was completely frozen three times without any apparent damage to the unit. We were also able to operate the heat exchanger in a partially frozen configuration to throttle the heat rejection rate from 530 Btu/h at low water flow rate down to 300 Btu/h. Finally, the deliberate loss of a single loop heat pipe only degraded the heat rejection performance by about 2 to 5%.

Nabity, James↗

Space Suit Radiator Performance in Lunar and Mars Environments

During an ExtraVehicular Activity (EVA), both the heat generated by the astronaut's metabolism and that produced by the Portable Life Support System (PLSS) must be rejected to space. The heat sources include the heat of adsorption of metabolic CO2, the heat of condensation of water, the heat removed from the body by the liquid cooling garment and the load from the electrical components. Although the sublimator hardware to reject this load weighs only 1.58 kg (3.48 lbm), an additional 3.6 kg (8 lbm) of water are loaded into the unit, most of which is sublimated and lost to thus become the single largest expendable during an eight hour EVA. We can significantly reduce the amount of expendable water consumed in the sublimator by using a radiator to reject heat from the Astronaut during an EVA. Last year we reported on the design and initial operational assessment tests of our novel radiator designated the Radiator And Freeze Tolerant heat eXchanger (RAFT-X). Herein, we report on tests conducted in the NASA Johnson Space Center Chamber E Thermal Vacuum Test Facility. Up to 260 W (900 Btu/h) of heat were rejected in Lunar and Mars environments with temperatures as cold as -170 C (- 275 F). Further, the RAFT-X endured several freeze / thaw cycles and in fact, the heat exchanger was completely frozen three times without any apparent damage to the unit.

Nabity, James↗

Materials-of-Construction Radiation Sensitivity for a Fission Surface Power Convertor

A fission reactor combined with a free-piston Stirling convertor is one of many credible approaches for producing electrical power in space applications. This study assumes dual-opposed free-piston Stirling engines/linear alternators that will operate nominally at 825 K hot-end and 425 K cold-end temperatures. The baseline design options, temperature profiles, and materials of construction discussed here are based on historical designs as well as modern convertors operating at lower power levels. This notional design indicates convertors primarily made of metallic components that experience minimal change in mechanical properties for fast neutron fluences less than 10(sup 20) neutrons per square centimeter. However, these radiation effects can impact the magnetic and electrical properties of metals at much lower fluences than are crucial for mechanical property integrity. Moreover, a variety of polymeric materials are also used in common free-piston Stirling designs for bonding, seals, lubrication, insulation and others. Polymers can be affected adversely by radiation doses as low as 10(sup 5) - 10(sup 10) rad. Additionally, the absorbing dose rate, radiation hardness, and the resulting effect (either hardening or softening) varies depending on the nature of the particular polymer. The classes of polymers currently used in convertor fabrication are discussed along possible substitution options. Thus, the materials of construction of prototypic Stirling convertor engines have been considered and the component materials susceptible to damage at the lowest neutron fluences have been identified.

Bowman, Cheryl L.↗

Chemical Data Assimilation Estimates of Continental US Ozone and Nitrogen Budgets during INTEX-A

Global ozone analyses, based on assimilation of stratospheric profile and ozone column measurements, and NOy predictions from the Real-time Air Quality Modeling System (RAQMS) are used to estimate the ozone and NOy budget over the Continental US during the July-August 2004 Intercontinental Chemical Transport Experiment-North America (INTEX-A). Comparison with aircraft, satellite, surface, and ozonesonde measurements collected during the INTEX-A show that RAQMS captures the main features of the global and Continental US distribution of tropospheric ozone, carbon monoxide, and NOy with reasonable fidelity. Assimilation of stratospheric profile and column ozone measurements is shown to have a positive impact on the RAQMS upper tropospheric/lower stratosphere ozone analyses, particularly during the period when SAGE III limb scattering measurements were available. Eulerian ozone and NOy budgets during INTEX-A show that the majority of the Continental US export occurs in the upper troposphere/lower stratosphere poleward of the tropopause break, a consequence of convergence of tropospheric and stratospheric air in this region. Continental US photochemically produced ozone was found to be a minor component of the total ozone export, which was dominated by stratospheric ozone during INTEX-A. The unusually low photochemical ozone export is attributed to anomalously cold surface temperatures during the latter half of the INTEX-A mission, which resulted in net ozone loss during the first 2 weeks of August. Eulerian NOy budgets are shown to be very consistent with previously published estimates. The NOy export efficiency was estimated to be 24 percent, with NOx+PAN accounting for 54 percent of the total NOy export during INTEX-A.

Pierce, Robert B.↗

Space Suit Radiator Performance in Lunar and Mars Environments

During an ExtraVehicular Activity (EVA), both the heat generated by the astronaut's metabolism and that produced by the Portable Life Support System (PLSS) must be rejected to space. The heat sources include the heat of adsorption of metabolic CO2, the heat of condensation of water, the heat removed from the body by the liquid cooling garment and the load from the electrical components. Although the sublimator hardware to reject this load weighs only 3.48 lbs, an additional eight pounds of water are loaded into the unit of which about six to eight are sublimated and lost; this is the single largest expendable during an eight-hour EVA. Using a radiator to reject heat from the Astronaut during an EVA, we can significantly reduce the amount of expendable water consumed by the sublimator. Last year we reported on the design and initial operational assessment tests of our novel radiator designated the Radiator And Freeze Tolerant heat eXchanger (RAFT-X). Herein, we report on tests conducted in the NASA Johnson Space Center Chamber E Thermal Vacuum Test Facility. Up to 800 Btu/h of heat were rejected in lunar and Mars environments with temperatures as cold as 150 F. Tilting the radiator did not cause an observable loss in performance. The RAFT-X endured freeze/thaw cycles and in fact, the heat exchanger was completely frozen three times without any apparent damage to the unit. We were also able to operate the heat exchanger in a partially frozen configuration to throttle the heat rejection rate from 530 Btu/h at low water flow rate down to 300 Btu/h. Finally, the deliberate loss of a single loop heat pipe only degraded the heat rejection performance by about 2 to 5%.

Paul, Heather↗