Search NASA⌕ Search

SEARCH · Search NASA

Results for “comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A Detailed Comparison of Multidimensional Boltzmann Neutrino Transport Methods in Core-collapse Supernovae

The mechanism driving core-collapse supernovae is sensitive to the interplay between matter and neutrino radiation. However, neutrino radiation transport is very difficult to simulate, and several radiation transport methods of varying levels of approximation are available. In this paper, we carefully compare for the first time in multiple spatial dimensions the discrete ordinates (DO) code of Nagakura, Yamada, and Sumiyoshi and the Monte Carlo (MC) code Sedonu, under the assumptions of a static fluid background, flat spacetime, elastic scattering, and full special relativity. We find remarkably good agreement in all spectral, angular, and fluid interaction quantities, lending confidence to both methods. The DO method excels in determining the heating and cooling rates in the optically thick region. The MC method predicts sharper angular features due to the effectively infinite angular resolution, but struggles to drive down noise in quantities where subtractive cancellation is prevalent, such as the net gain in the protoneutron star and off-diagonal components of the Eddington tensor. We also find that errors in the angular moments of the distribution functions induced by neglecting velocity dependence are subdominant to those from limited momentum-space resolution. We briefly compare directly computed second angular moments to those predicted by popular algebraic two-moment closures, and we find that the errors from the approximate closures are comparable to the difference between the DO and MC methods. Finally, included in this work is an improved Sedonu code, which now implements a fully special relativistic, time-independent version of the grid-agnostic MC random walk approximation.

79 ASTRONOMY AND ASTROPHYSICS↗

A Comparison of Cosmological Parameters Determined from CMB Temperature Power Spectra from the South Pole Telescope and the Planck Satellite

The Planck cosmic microwave background temperature data are best fit with a Lambda CDM model that mildly contradicts constraints from other cosmological probes. The South Pole Telescope (SPT) 2540 deg(2) SPT-SZ survey offers measurements on sub-degree angular scales (multipoles 650 <= l <= 2500) with sufficient precision to use as an independent check of the Planck data. Here we build on the recent joint analysis of the SPT-SZ and Planck data in Hou et al. by comparing Lambda CDM parameter estimates using the temperature power spectrum from both data sets in the SPT-SZ survey region. We also restrict the multipole range used in parameter fitting to focus on modes measured well by both SPT and Planck, thereby greatly reducing sample variance as a driver of parameter differences and creating a stringent test for systematic errors. We find no evidence of systematic errors from these tests. When we expand the maximum multipole of SPT data used, we see low-significance shifts in the angular scale of the sound horizon and the physical baryon and cold dark matter densities, with a resulting trend to higher Hubble constant. When we compare SPT and Planck data on the SPT-SZ sky patch to Planck full-sky data but keep the multipole range restricted, we find differences in the parameters n(s) and A(s)e(-2 tau). We perform further checks, investigating instrumental effects and modeling assumptions, and we find no evidence that the effects investigated are responsible for any of the parameter shifts. Taken together, these tests reveal no evidence for systematic errors in SPT or Planck data in the overlapping sky coverage and multipole range and at most weak evidence for a breakdown of Lambda CDM or systematic errors influencing either the Planck data outside the SPT-SZ survey area or the SPT data at l > 2000.

Aylor, K.↗

The Electromagnetic Counterpart of the Binary Neutron Star Merger LIGO/Virgo GW170817. II. UV, Optical, and Near-infrared Light Curves and Comparison to Kilonova Models

We present UV, optical, and near-infrared (NIR) photometry of the first electromagnetic counterpart to a gravitational wave source from Advanced Laser Interferometer Gravitational-wave Observatory (LIGO)/Virgo, the binary neutron star merger GW170817. Our data set extends from the discovery of the optical counterpart at 0.47–18.5 days post-merger, and includes observations with the Dark Energy Camera (DECam), Gemini-South/FLAMINGOS-2 (GS/F2), and the Hubble Space Telescope (HST). The spectral energy distribution (SED) inferred from this photometry at 0.6 days is well described by a blackbody model with T≈8300 K, a radius of R≈4.5×10{sup 14} cm (corresponding to an expansion velocity of v≈0.3c), and a bolometric luminosity of L{sub bol}≈5×10{sup 41} erg s{sup −1}. At 1.5 days we find a multi-component SED across the optical and NIR, and subsequently we observe rapid fading in the UV and blue optical bands and significant reddening of the optical/NIR colors. Modeling the entire data set, we find that models with heating from radioactive decay of {sup 56}Ni, or those with only a single component of opacity from r-process elements, fail to capture the rapid optical decline and red optical/NIR colors. Instead, models with two components consistent with lanthanide-poor and lanthanide-rich ejecta provide a good fit to the data; the resulting “blue” component has M{sub ej}{sup blue}≈0.01 M{sub ⊙} and v{sub ej}{sup blue}≈0.3 c, and the “red” component has M{sub ej}{sup red}≈0.04 M{sub ⊙} and v{sub ej}{sup red}≈0.1 c. These ejecta masses are broadly consistent with the estimated r-process production rate required to explain the Milky Way r-process abundances, providing the first evidence that binary neutron star (BNS) mergers can be a dominant site of r-process enrichment.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of Vaisala radiosondes RS41 and RS92 at the ARM Southern Great Plains site

In the fall of 2013, the Vaisala RS41 (fourth generation) radiosonde was introduced as a replacement for the RS92-SGP radiosonde with improvements in measurement accuracy of profiles of atmospheric temperature, humidity, and pressure. In order to help characterize these improvements, an intercomparison campaign was undertaken at the US Department of Energy's Atmospheric Radiation Measurement (ARM) Climate Research Facility site in north-central Oklahoma, USA. During 3–8 June 2014, a total of 20 twin-radiosonde flights were performed in a variety of atmospheric conditions representing typical midlatitude continental summertime conditions. The results show that for most of the observed conditions the RS92 and RS41 measurements agree much better than the manufacturer-specified combined uncertainties with notable exceptions when exiting liquid cloud layers where the “wet-bulbing” effect appears to be mitigated for several cases in the RS41 observations. The RS41 measurements of temperature and humidity, with applied correction algorithms, also appear to show less sensitivity to solar heating. In addition, these results suggest that the RS41 does provide important improvements, particularly in cloudy conditions. For many science applications – such as atmospheric process studies, retrieval development, and weather forecasting and climate modeling – the differences between the RS92 and RS41 measurements should have little impact. However, for long-term trend analysis and other climate applications, additional characterization of the RS41 measurements and their relation to the long-term observational records will be required.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Ground-Based 3-Dimensional Lightning Mapping Observations with Satellite-Based LIS Observations in Oklahoma: Comparison of LMS and LIS Lightning Mapping

3-dimensional lightning mapping observations obtained during the MEaPRS program in central Oklahoma during June, 1998 have been compared with observations of the discharges from space, obtained by NASA's Lightning Imaging Sensor (LIS) on the TRMM satellite. Excellent spatial and temporal correlations were observed between the two sets of observations. Most of the detected optical events were associated with intracloud discharges that developed into the upper part of the storm. Cloud-to-ground discharges that were confined to mid- and lower-altitudes tended not to be detected by LIS. Extensive illumination tended to occur in impulsive bursts toward the end or part way through intracloud flashes and appeared to be produced by energetic K-changes that typically occur at these times.

Thomas, Ronald J.↗

Comparison of Trajectory Models in Calculations of N2-broadened Half-widths and N2-induced Line Shifts for the Rotational Band of H2O-16 and Comparison with Measurements

In this work, Complex Robert-Bonamy calculations of half-widths and line shifts were done for N2-broadening of water for 1639 transitions in the rotational band using two models for the trajectories. The first is a model correct to second order in time, the Robert-Bonamy parabolic approximation. The second is the solution of Hamilton's equations. Both models use the isotropic part of the atom-atom potential to determine the trajectories. The present calculations used an intermolecular potential expanded to 20th order to assure the convergence of the half-widths and line shifts. The aim of the study is to assess if the difference in the half-widths and line shifts determined from the two trajectory models is greater than the accuracy requirements of the spectroscopic and remote sensing communities. The results of the calculations are compared with measurements of the half-widths and line shifts. It is shown that the effects of the trajectory model greatly exceed the needs of current remote sensing measurements and that line shape parameters calculated using trajectories determined by solving Hamilton's equations agree better with measurement.

Lamouroux, J.↗

European Measurement Comparisons of Environmental Radioactivity

The scheme of European measurement comparisons to verify radioactivity monitoring in the European Union is briefly explained. After a review of comparisons conducted during the years 1990, the approach of IRMM organising these comparisons since 2003 is presented. IRMM is providing comparison samples with a reference value traceable to the SI units and which is fully documented to all participants and national authorities after completion of the comparison. The sample preparation and determination of traceable reference values at IRMM, the sample treatment and measurement in the participating laboratories, as well as the evaluation of comparison results are described in some detail using the example of an air filter comparison. The results of a comparison to determine metabolised {sup 40}K, {sup 90}Sr and {sup 137}Cs in milk powder are presented as well. The necessary improvements in the estimation of measurement uncertainty by the participating laboratories are discussed. The performance of individual laboratories which have participated in at least four comparison exercises over the years is studied in terms of observable trends.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long History of IAM Comparisons

Correspondence to editor: We agree with the editors that the assumptions behind models of all types, including integrated assessment models (IAMs), should be as transparent as possible. The editors were in error, however, when they implied that the IAM community is just “now emulating the efforts of climate researchers by instigating their own model inter-comparison projects (MIPs).” In fact, model comparisons for integrated assessment and climate models followed a remarkably similar trajectory. Early General Circulation Model (GCM) comparison efforts, evolved to the first Atmospheric Model Inter-comparison Project (AMIP), which was initiated in the early 1990s. Atmospheric models evolved to coupled atmosphere-ocean models (AOGCMs) and results from the first Coupled Model Inter-Comparison Project (CMIP1) become available about a decade later. Results of first energy model comparison exercise, conducted under the auspices of the Stanford Energy Modeling Forum, were published in 1977. A summary of the first comparison focused on climate change was published in 1993. As energy models were coupled to simple economic and climate models to form IAMs, the first comparison exercise for IAMs (EMF-14) was initiated in 1994, and IAM comparison exercises have been on-going since this time.

Smith, Steven J.↗

SNPP and N20 VIIRS Thermal Emissive Bands Calibration Comparison Using the GEO-LEO Double Difference Method

The VIIRS instruments onboard the SNPP and NOAA-20 satellites have identical spatial resolutions and the same spectral bands. Similar prelaunch tests and identical on-orbit calibration algorithms established the foundation for their consistent Earth measurements. Calibration assessment and consistency comparisons are useful to maintain their performance and measurement accuracy. Simultaneous nadir overpasses (SNO) between two satellites are commonly used for a direct calibration comparison between sensors. However, there are no SNO between SNPP and NOAA20. Hence, a reference sensor or Earth measurements are normally used to bridge the comparison. As a reference, we focus on the Advanced Baseline Imager (ABI) onboard the GOES-R series spacecraft and its application to the SNPP and NOAA-20 VIIRS comparison. GOES16 and GOES17are the first two satellites of the GOES-R series and were launched on November 19, 2016, and March 12, 2018, respectively. Their operational positions are on the equator with longitudes of 75.2° West over land and 137.2° West over ocean, respectively. The ABI is the primary imaging instrument of these spacecrafts for the Earth’s weather, oceans, and environment, with observations (every 10 minutes) that provide vast data for GEO-Low Earth orbit (LEO)and LEO-LEO comparisons utilizing it as an intermediate reference sensor. VIIRS and ABI have spectrally matched bands and can have simultaneous measurements over any selected site every day. The simultaneous measurements over the same site also have various scan angles. These features provide advantages for a VIIRS-to-ABI comparison. The spectral response function difference between instruments, sites selected, and view angles will have effects on the instrument measurements. Their impacts on the calibration comparison, including the use of double differences, will be discussed. By collecting VIIRS measurements over a large range of view angles, the view angle effect will also be investigated. The collection of an ample amount of data provides an advantage for statistical analyses and potential big data applications to sensor calibration assessments. This method can also be applied to other sensor calibration comparison and performance assessments, such as GOES16 and GOES17 ABI, and Terra and Aqua MODIS.

Tiejun Chang↗

TRT Compton Scattering Data: Comparisons between LLNL and LANL: Pointwise

This memo is one of a pair of reports comparing Compton scattering data in the context of thermal radiation transport (TRT). This document focuses on Pointwise (PW) data while the other report focuses on Multigroup (MG) data. These complementary analyses, via PW comparisons, show if the same physics are used and if fundamental bugs are present, and, via MG comparisons, quantify macroscopic Compton effects such as mean amplification factors. No averaging of Compton data over photon energy is done for the PW comparisons, while lab-dependent numerical resolution choices become relevant for the MG comparisons. This document plots and quantifies differences in PW Compton scattering data between LANL and LLNL for four disparate temperatures on a logarithmically-spaced energy grid. PW comparisons means we use the received LLNL data as-is, without any averaging or integration over energy. In addition to LANL-to-LLNL comparisons, we investigate the impact of numerical choices on LANL PW data. For the purposes of this comparison, we neglect induced scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MODIS comparisons with northeastern Pacific in situ stratocumulus microphysics

Abstract Vertical sounding measurements within stratocumuli during two aircraft field campaigns, Marine Stratus/stratocumulus Experiment (MASE) and Physics of Stratocumulus Top (POST), are used to validate Moderate Resolution Imaging Spectroradiometer (MODIS) cloud optical thickness (COT), cloud liquid water path (LWP), and cloud effective radius ( r e ). In situ COT, LWP, and r e were calculated using 5 m vertically averaged droplet probe measurements of complete vertical cloud penetrations. MODIS COT, LWP, and r e 1 km pixels were averaged along these penetrations. COT comparisons in POST showed strong correlations and a near 1:1 relationship. In MASE, comparisons showed strong correlations; however, MODIS COT exceeded in situ COT, likely due to larger temporal differences between MODIS and in situ measurements. LWP comparisons between two cloud probes show good agreement for POST but not MASE, giving confidence to POST data. Both projects provided strong LWP correlations but MODIS exceeded in situ by 14–36%. MODIS in situ r e correlations were strong, but MODIS 2.1 µm r e exceeded in situ r e , which contributed to LWP bias; in POST, MODIS r e was 20–30% greater than in situ r e . Maximum in situ r e near cloud top showed comparisons nearer 1:1. Other MODIS r e bands (3.7 µm and 1.6 µm) showed similar comparisons. Temporal differences between MODIS and in situ measurements, airplane speed differences, and cloud probe artifacts were likely causes of weaker MASE correlations. POST COT comparison was best for temporal differences under 20 min. POST data validate MODIS COT but it also implies a positive MODIS r e bias that propagates to LWP while still capturing variability.

54 ENVIRONMENTAL SCIENCES↗

CLASH-X: A comparison of lensing and X-ray techniques for measuring the mass profiles of galaxy clusters

We present profiles of temperature, gas mass, and hydrostatic mass estimated from new and archival X-ray observations of CLASH clusters. We compare measurements derived from XMM and Chandra observations with one another and compare both to gravitational lensing mass profiles derived with CLASH Hubble Space Telescope and Subaru Telescope lensing data. Radial profiles of Chandra and XMM measurements of electron density and enclosed gas mass are nearly identical, indicating that differences in hydrostatic masses inferred from X-ray observations arise from differences in gas-temperature measurements. Encouragingly, gas temperatures measured in clusters by XMM and Chandra are consistent with one another at ∼100-200 kpc radii, but XMM temperatures systematically decline relative to Chandra temperatures at larger radii. The angular dependence of the discrepancy suggests that additional investigation on systematics such as the XMM point-spread function correction, vignetting, and off-axis responses is yet required. We present the CLASH-X mass-profile comparisons in the form of cosmology-independent and redshift-independent circular-velocity profiles. We argue that comparisons of circular-velocity profiles are the most robust way to assess mass bias. Ratios of Chandra hydrostatic equilibrium (HSE) mass profiles to CLASH lensing profiles show no obvious radial dependence in the 0.3-0.8 Mpc range. However, the mean mass biases inferred from the weak-lensing (WL) and SaWLens data are different. As an example, the weighted-mean value at 0.5 Mpc is (b) = 0.12 for the WL comparison and (b) = –0.11 for the SaWLens comparison. The ratios of XMM HSE mass profiles to CLASH lensing profiles show a pronounced radial dependence in the 0.3-1.0 Mpc range, with a weighted mean mass bias value rising to (b) ≳ 0.3 at ∼1 Mpc for the WL comparison and (b) ≈ 0.25 for the SaWLens comparison. The enclosed gas mass profiles from both Chandra and XMM rise to a value ≈1/8 times the total-mass profiles inferred from lensing at ≈0.5 Mpc and remain constant outside of that radius, suggesting that M {sub gas} × 8 profiles may be an excellent proxy for total-mass profiles at ≳ 0.5 Mpc in massive galaxy clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-231: Cross-Validation of 3D Gamma Comparison Tools

Purpose: Moving the computational analysis for 3D gel dosimetry into the 3D Slicer (www.slicer.org) environment has made gel dosimetry more clinically accessible. To ensure accuracy, we cross-validate the 3D gamma comparison module in 3D Slicer with an independently developed algorithm using simulated and measured dose distributions. Methods: Two reference dose distributions were generated using the Varian Eclipse treatment planning system. The first distribution consisted of a four-field box irradiation delivered to a plastic water phantom and the second, a VMAT plan delivered to a gel dosimeter phantom. The first reference distribution was modified within Eclipse to create an evaluated dose distribution by spatially shifting one field by 3mm, increasing the monitor units of the second field, applying a dynamic wedge for the third field, and leaving the fourth field unchanged. The VMAT plan was delivered to a gel dosimeter and the evaluated dose in the gel was calculated from optical CT measurements. Results from the gamma comparison tool built into the SlicerRT toolbox were compared to results from our in-house gamma algorithm implemented in Matlab (via MatlabBridge in 3D Slicer). The effects of noise, resolution and the exchange of reference and evaluated designations on the gamma comparison were also examined. Results: Perfect agreement was found between the gamma results obtained using the SlicerRT tool and our Matlab implementation for both the four-field box and gel datasets. The behaviour of the SlicerRT comparison with respect to changes in noise, resolution and the role of the reference and evaluated dose distributions was consistent with previous findings. Conclusion: Two independently developed gamma comparison tools have been cross-validated and found to be identical. As we transition our gel dosimetry analysis from Matlab to 3D Slicer, this validation serves as an important test towards ensuring the consistency of dose comparisons using the 3D Slicer environment.

60 APPLIED LIFE SCIENCES↗

Material Property Correlations: Comparisons between FRAPCON-3.4, FRAPTRAN 1.4, and MATPRO

The U.S. Nuclear Regulatory Commission (NRC) uses the computer codes FRAPCON-3 and FRAPTRAN to model steady state and transient fuel behavior, respectively, in regulatory analysis. In order to effectively model fuel behavior, material property correlations must be used for a wide range of operating conditions (e.g. temperature and burnup). In this sense, a 'material property' is a physical characteristic of the material whose quantitative value is necessary in the analysis process. Further, the property may be used to compare the benefits of one material versus another. Generally speaking, the material properties of interest in regulatory analysis of nuclear fuel behavior are mechanical or thermodynamic in nature. The issue of what is and is not a 'material property' will never be universally resolved. In this report, properties such as thermal conductivity are included. Other characteristics of the material (e.g. fission gas release) are considered 'models' rather than properties, and are discussed elsewhere. Still others (e.g., neutron absorption cross-section) are simply not required in this specific analysis. The material property correlations for the FRAPCON-3 and FRAPTRAN computer codes were documented in NUREG/CR-6534 and NUREG/CR-6739, respectively. Some of these have been modified or updated since the original code documentation was published. The primary purpose of this report is to consolidate the current material property correlations used in FRAPCON-3 and FRAPTRAN into a single document. Material property correlations for oxide fuels, including uranium dioxide (UO2) and mixed oxide (MOX) fuels, are described in Section 2. Throughout this document, the term MOX will be used to describe fuels that are blends of uranium and plutonium oxides, (U,Pu)O2. The properties for uranium dioxide with other additives (e.g., gadolinia) are also discussed. Material property correlations for cladding materials and gases are described in Sections 3 and 4, respectively. In addition to describing the material property correlations used in the subroutines of FRAPCON-3 and FRAPTRAN, this report also provides a variety of comparisons between material property correlations and data. Although they are frequently identical, comparisons are made between the material property correlations used in the FRAPCON-3 and FRAPTRAN codes. Comparisons are also made between the material property correlations used in MATPRO, a compilation of fuel and cladding material property correlations with an extensive history of used with various fuel performance and severe accident codes. For a number of reasons, consistency between the material property correlations in FRAPCON-3, FRAPTRAN, and MATPRO has never been complete. However, the current versions of FRAPCON-3 and FRAPTRAN use a relatively consistent set of correlations for the properties that are used by both codes. The material property correlations in the most recent version of MATPRO are documented in Volume 4 of NUREG/CR-6150. In addition to comparison of the various correlations, correlation-to-data comparisons are also made with FRAPCON-3, FRAPTRAN, and MATPRO. All comparisons made in this report are based on the material property correlations used in the most recent version of the FRAPCON-3 and FRAPTRAN codes, FRAPCON-3.4 and FRAPTRAN 1.4. The source code for each material property correlation discussed will be provided for FRAPCON-3.4 and FRAPTRAN 1.4 (see appendix) as well as a range of applicability and an estimate of uncertainty where possible.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗