Search NASA⌕ Search

SEARCH · Search NASA

Results for “connected lighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Mold and method for molding a reinforced preform

A mold for molding a reinforced preform having at least two apertures therein includes first and second mold halves, first and second emitters disposed in the mold halves and configured to emit light therefrom, first and second receivers disposed in the mold halves and configured to receive light from the respective first and second emitters, and first and second moving members having couplings for connection with side portions of the reinforced preform and actuators for moving the couplings between respective first and second positions. A controller determines an alignment condition based on signals received from the receivers. If the alignment condition fails to meet predetermined criteria, then at least one of the actuators is caused to move its coupling from its respective first position to a respective adjusted position that is different from the respective second position.

Rodgers, William R.↗

Rapid eco‐phenotypic feedback and the temperature response of biomass dynamics

Biomass dynamics capture information on population dynamics and ecosystem-level processes (e.g., changes in production over time). Understanding how rising temperatures associated with global climate change influence biomass dynamics is thus a pressing issue in ecology. The total biomass of a species depends on its density and its average mass. Consequently, disentangling how biomass dynamics responds to increasingly warm and variable temperatures ultimately depends on understanding how temperature influences both density and mass dynamics. Here, we address this issue by keeping track of experimental microbial populations growing to carrying capacity for 15 days at two different temperatures, and in the presence and absence of temperature variability. We develop a simple mathematical expression to partition the contribution of changes in density and mass to changes in biomass and assess how temperature responses in either one influence biomass shifts. Moreover, we use time-series analysis (Convergent Cross Mapping) to address how temperature and temperature variability influence reciprocal effects of density on mass and vice versa. We show that temperature influences biomass through its effects on density and mass dynamics, which have opposite effects on biomass and can offset each other. We also show that temperature variability influences biomass, but that effect is independent of any effects on density or mass dynamics. Last, we show that reciprocal effects of density and mass shift significantly across temperature regimes, suggesting that rapid and environment-dependent eco-phenotypic dynamics underlie biomass responses. Overall, our results connect temperature effects on population and phenotypic dynamics to explain how biomass responds to temperature regimes, thus shedding light on processes at play in cosmopolitan and abundant microbes as the world experiences increasingly warm and variable temperatures.

54 ENVIRONMENTAL SCIENCES↗

A medium-range structure motif linking amorphous and crystalline states

Amorphous materials have no long-range order, but there are ordered structures at short range (2–5 Å), medium range (5–20 Å) and even longer length scales. While regular and semiregular polyhedra are often found as short-range ordering in amorphous materials, the nature of medium-range order has remained elusive. Consequently, it is difficult to determine whether there exists any structural link at medium range or longer length scales between the amorphous material and its crystalline counterparts. Moreover, an amorphous material often crystallizes into a phase of different composition, with very different underlying structural building blocks, further compounding the issue. Here, we capture an intermediate crystalline cubic phase in a Pd-Ni-P amorphous alloy and reveal the structure of the medium-range order, a six-membered tricapped trigonal prism cluster (6M-TTP) with a length scale of 12.5 Å. We find that the 6M-TTP can pack periodically to several tens of nanometres to form the cube phase. Our experimental observations provide evidence of a structural link between the amorphous and crystalline phases in a Pd-Ni-P alloy at the medium-range length scale and suggest that it is the connectivity of the 6M-TTP clusters that distinguishes the crystalline and amorphous phases. These findings will shed light on the structure of amorphous materials at extended length scales beyond that of short-range order.

36 MATERIALS SCIENCE↗

Model for current drive induced crash cycles in W7-X

In the Wendelstein 7-X (W7-X) stellarator, the vacuum rotational transform, ι, has a flat radial profile and does not cross any major rational resonance. Nevertheless, during plasma operation the ι–profile can be strongly modified by electron cyclotron current drive in such a way that the resulting ι-profile passes through low-order rational values, and this can trigger magnetohydrodynamic (MHD) events. Indeed, W7-X plasmas are sometimes subject to repetitive collapses of core confinement, which can be observed regardless of the direction in which the EC current is driven. Even though the origin of these MHD instabilities is under investigation, the crashes may be connected to the formation of magnetic islands and magnetic reconnection. In the present work, we try to shed light on the dynamics of different events happening during the course of sawtooth cycles in W7-X by proposing a model that combines a slow current diffusion with a recipe for fast relaxation that conserves the corresponding helical flux (Kadomtsev 1975 Fiz. Plazmy 1 710–15). We also propose a simple model based on Taylor relaxation (Taylor 1974 Phys. Rev. Lett. 33 1139), (Taylor 1986 Rev. Mod. Phys. 58 741) to predict the nonlinear redistribution of plasma current caused by the largest of the observed events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward nonthermal control of excited quantum materials: framework and investigations by ultrafast electron scattering and imaging

Quantum material systems upon applying ultrashort laser pulses provide a rich platform to access excited material phases and their transformations that are not entirely like their equilibrium counterparts. The addressability and potential controls of metastable or long-trapped out-of-equilibrium phases have motivated interests both for the purposes of understanding the nonequilibrium physics and advancing the quantum technologies. Thus far, the dynamical spectroscopic probes eminently focus on microscopic electronic and phonon responses. For characterizing the long-range dynamics, such as order parameter fields and fluctuation effects, the ultrafast scattering probes offer direct sensitivity. Bridging the connections between the microscopic dynamics and macroscopic responses is central toward establishing the nonequilibrium physics behind the light-induced phases. Here, we present a path toward such understanding by cross-examining the structure factors associated with different dynamical states obtained from ultrafast electron scattering, imaging, and modeling. We give the basic theoretical framework on describing the non-equilibrium scattering problems and briefly describe how such framework relates to the out-of-equilibrium phenomena. We give effective models outlining the emergences of nonthermal critical points, hidden phases, and non-equilibrium relaxational responses from vacuum-suspended rare-earth tritellurides, tantalum disulfides thin films, and vanadium dioxide nanocrystalline materials upon light excitations.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapidly pulsed, high intensity, incoherent light source

A rapid pulsing, high intensity, incoherent light is produced by selectively energizing a plurality of discharge lamps with a triggering circuit. Each lamp is connected to a capacitor, and a power supply is electrically connected to all but one of the capacitors. This last named capacitor is electrically connected to a discharge lamp which is connected to the triggering circuit.

Evans, J. C., Jr.↗

Three-dimensional laser velocimeter simultaneity detector

A three-dimensional laser Doppler velocimeter has laser optics for a first channel positioned to create a probe volume in space, and laser optics and for second and third channels, respectively, positioned to create entirely overlapping probe volumes in space. The probe volumes and overlap partially in space. The photodetector is positioned to receive light scattered by a particle present in the probe volume, while photodetectors and are positioned to receive light scattered by a particle present in the probe volume. The photodetector for the first channel is directly connected to provide a first channel analog signal to frequency measuring circuits. The first channel is therefore a primary channel for the system. Photodetectors and are respectively connected through a second channel analog signal attenuator to frequency measuring circuits and through a third channel analog signal attenuator to frequency measuring circuits. The second and third channels are secondary channels, with the second and third channels analog signal attenuators and controlled by the first channel measurement burst signal on line. The second and third channels analog signal attenuators and attenuate the second and third channels analog signals only when the measurement burst signal is false.

Brown, James L.↗

Micro-Imagers for Spaceborne Cell-Growth Experiments

A document discusses selected aspects of a continuing effort to develop five micro-imagers for both still and video monitoring of cell cultures to be grown aboard the International Space Station. The approach taken in this effort is to modify and augment pre-existing electronic micro-cameras. Each such camera includes an image-detector integrated-circuit chip, signal-conditioning and image-compression circuitry, and connections for receiving power from, and exchanging data with, external electronic equipment. Four white and four multicolor light-emitting diodes are to be added to each camera for illuminating the specimens to be monitored. The lens used in the original version of each camera is to be replaced with a shorter-focal-length, more-compact singlet lens to make it possible to fit the camera into the limited space allocated to it. Initially, the lenses in the five cameras are to have different focal lengths: the focal lengths are to be 1, 1.5, 2, 2.5, and 3 cm. Once one of the focal lengths is determined to be the most nearly optimum, the remaining four cameras are to be fitted with lenses of that focal length.

Behar, Alberto↗

Broadband light emitting zero-dimensional antimony and bismuth-based hybrid halides with diverse structures

Low-dimensional organic–inorganic metal halides have recently attracted extensive attention because of their various structures and distinguished photoelectric properties. Herein, we report a series of new zero-dimensional organic–inorganic hybrid metal halides: (TMEDA) 3 Bi 2 Cl 12 ·H 2 O, (TMEDA) 3 Bi 2 Br 12 ·H 2 O, (TMEDA) 3 Sb 2 Br 12 ·H 2 O, and (TMEDA) 5 Sb 6 Cl 28 ·2H 2 O [TMEDA = N,N,N'·trimethylethylenediamine]. (TMEDA) 3 M 2 X 12 ·H 2 O (M = Bi or Sb, X = Cl or Br) crystallizes in the monoclinic space group P2 1 /n, and (TMEDA) 5 Sb 6 Cl 28 ·2H 2 O crystallizes in the orthorhombic space group Pnma. (TMEDA) 3 M 2 X 12 possesses a zero-dimensional structure with the metal halide ions of [MBr 6 ] 3- isolated by the organic TMEDA 2+ cations. Interestingly, the (TMEDA) 5 Sb 6 Cl 28 ·2H 2 O structure consists of a combination of corner-connected octahedra [Sb 4 Cl 18 ] 6- and edge-shared [Sb 2 Cl 10 ] 4- , which is quite rare. The light emission of all these compounds was measured, and (TMEDA) 3 Sb 2 Br 12 ·H 2 O exhibits the most intense luminescence. Upon 400 nm ultraviolet light excitation, (TMEDA) 3 Sb 2 Br 12 ·H 2 O exhibited strong broadband yellow emission centered at 625 nm with a full-width at half-maximum of ~150 nm originating from self-trapped excitons. In conclusion, this work suggests the possibility of new types of hybrid halides by introducing different metal centers and probing the structural evolution and photoluminescent properties, serving as a reference for the relationship between structure and luminescent performance and demonstrating their potential use as phosphors in light-emitting diodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Subaru SCExAO First-Light Direct Imaging of a Young Debris Disk around HD 36546

We present H-band scattered light imaging of a bright debris disk around the A0 star HD 36546 obtained from the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) system with data recorded by the HiCIAO camera using the vector vortex coronagraph. SCExAO traces the disk from r approximately 0 3 to r approximately 0".3 to r approximately 1" (34-114 au). The disk is oriented in a near east west direction (PA approximately 75deg), is inclined by I approximately 70deg-75deg, and is strongly forward-scattering(g greater than 0.5). It is an extended disk rather than a sharp ring; a second, diffuse dust population extends from the disks eastern side. While HD 36546 intrinsic properties are consistent with a wide age range (t approximately 1-250 Myr), its kinematics and analysis of coeval stars suggest a young age (310 Myr) and a possible connection to Taurus-Aurigas star formation history. SCExAOs planet-to-star contrast ratios are comparable to the first-light Gemini Planet Imager contrasts; for an age of 10 Myr, we rule out planets with masses comparable to HR 8799 b beyond a projected separation of 23 au. A massive icy planetesimal disk or an unseen super-Jovian planet at r greater than 20 au may explain the disks visibility. The HD 36546 debris disk may be the youngest debris disk yet imaged, is the first newly identified object from the now-operational SCExAO extreme AO system, is ideally suited for spectroscopic follow-up with SCExAO/CHARIS in 2017, and may be a key probe of icy planet formation and planet disk interactions.

Subaru Coronagraphic Extreme Adaptive Optics (SCEx↗

DC-to-DC power supply for light aircraft flight testing

The power supply unit was developed to serve as the power source for a loran-C receiver. The power supply can be connected directly to the aircraft's electrical system, and is compatible with either 14 or 28 volt electrical systems. Design specifications are presented for the unit along with a description of the circuit design.

Yost, S. R.↗

Filament eruption connected to protospheric activity

Two cases of activation of filaments that occured in regions of intense magnetic activity was studied. The simultaneous observations from Debrecen Observatory (white light and H alpha filtergram), and from Meudon Observatory (magnetogram, MSDP dopplergram and intensity maps in H alpha) gave a complementary set of data from which can be produced evidence of the influence of the photospheric magnetic field on the destabilization process of the filaments. On June 22, 1980, the eruption of the filament is associated with the motion of pores, which are manifestations of emerging flux knots. On September 3, 1980, the twisting motions in the filament are associated to the birth of a pore in its neighborhood. These observations are discussed.

Simon, G.↗

Metasurfaces for photonic devices

Notably, metasurfaces have attracted significant attention owing to their broad capability to achieve exotic electromagnetic responses, and their potential as optical devices for wavefront control. Wide ranging materials may be used to form metasurfaces including noble and non-noble metals, oxides, ceramics, phase change materials, and semiconductors, permitting versatile and reconfigurable properties ideal for applications. In particular, applications that affect the science and technology of light—i.e., photonics—are of interest and will continue to grow in importance as our society becomes more digitally connected, but yet environmentally conscious.

36 MATERIALS SCIENCE↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗

Vacuum probe surface sampler

A vacuum probe surface sampler is described for rapidly sampling relatively large surface areas which possess relatively light loading densities of micro-organism, drug particles or the like. A vacuum head with a hollow handle connected to a suitable vacuum source is frictionally attached to a cone assembly terminating in a flared tip adapted to be passed over the surface to be sampled. A fine mesh screen carried by the vacuum head provides support for a membrane filter which collects the microorganisms or other particles. The head assembly is easily removed from the cone assembly without contacting the cone assembly with human hands.

Zahlava, B. A.↗

Heat-Exchanger/Heat-Pipe Interface

Monolithic assembly reliable and light in weight. Heat exchanger and evaporator ends of heat pipes integrated in monolithic halves welded together. Interface assembly connects heat exchanger of furnace, reactor, or other power source with heat pipes carrying heat to radiator or power-consuming system. One of several concepts proposed for nuclear power supplies aboard spacecraft, interface useful on Earth in solar thermal power systems, heat engines, and lightweight cooling systems.

Snyder, H. J.↗

The radio-far infrared correlation: Spiral and blue compact dwarf galaxies opposed

The recently established correlation between radio continuum and far infrared emission in galaxies was further investigated by comparing normal spiral and blue compact dwarf galaxies. The puzzling result is that the ratio of radio to far infrared luminosity and its dispersion is the same for both samples, although their ratios of blue to far infrared luminosity, their radio spectral indices and their dust temperatures exhibit markedly different mean values and dispersions. This suggests that the amount of energy radiated in the two regimes is enhanced in the same way although the mechanisms responsible for the two components are rather different and complex. The fact that the blue light does not increase at the same proportion shows that both the radio and the far infrared emission are connected with the recent star formation history.

Klein, U.↗

Ethylene monitoring and control system

A system that can accurately monitor and control low concentrations of ethylene gas includes a test chamber configured to receive sample gas potentially containing an ethylene concentration and ozone, a detector configured to receive light produced during a reaction between the ethylene and ozone and to produce signals related thereto, and a computer connected to the detector to process the signals to determine therefrom a value of the concentration of ethylene in the sample gas. The supply for the system can include a four way valve configured to receive pressurized gas at one input and a test chamber. A piston is journaled in the test chamber with a drive end disposed in a drive chamber and a reaction end defining with walls of the test chamber a variable volume reaction chamber. The drive end of the piston is pneumatically connected to two ports of the four way valve to provide motive force to the piston. A manifold is connected to the variable volume reaction chamber, and is configured to receive sample gasses from at least one of a plurality of ports connectable to degreening rooms and to supply the sample gas to the reactive chamber for reaction with ozone. The apparatus can be used to monitor and control the ethylene concentration in multiple degreening rooms.

Nelson, Bruce N.↗