Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Optimization of Operating Parameters for Minimum Mechanical Specific Energy in Drilling

Efficiency in drilling is measured by Mechanical Specific Energy (MSE). MSE is the measure of the amount of energy input required to remove a unit volume of rock, expressed in units of energy input divided by volume removed. It can be expressed mathematically in terms of controllable parameters; Weight on Bit, Torque, Rate of Penetration, and RPM. It is well documented that minimizing MSE by optimizing controllable factors results in maximum Rate of Penetration. Current methods for computing MSE make it possible to minimize MSE in the field only through a trial-and-error process. This work makes it possible to compute the optimum drilling parameters that result in minimum MSE. The parameters that have been traditionally used to compute MSE are interdependent. Mathematical relationships between the parameters were established, and the conventional MSE equation was rewritten in terms of a single parameter, Weight on Bit, establishing a form that can be minimized mathematically. Once the optimum Weight on Bit was determined, the interdependent relationship that Weight on Bit has with Torque and Penetration per Revolution was used to determine optimum values for those parameters for a given drilling situation. The improved method was validated through laboratory experimentation and analysis of published data. Two rock types were subjected to four treatments each, and drilled in a controlled laboratory environment. The method was applied in each case, and the optimum parameters for minimum MSE were computed. The method demonstrated an accurate means to determine optimum drilling parameters of Weight on Bit, Torque, and Penetration per Revolution. A unique application of micro-cracking is also presented, which demonstrates that rock failure ahead of the bit is related to axial force more than to rotation speed.

42 ENGINEERING↗

SU-E-J-136: Multimodality-Image-Based Target Delineation for Dose Painting of Pancreatic Cancer

Purpose: Dose escalated RT may provide improved disease local-control for selected unresectable pancreatic cancer. Accurate delineation of the gross tumor volume (GTV) inside pancreatic head or body would allow safe dose escalation considering the tolerances of adjacent organs at risk (OAR). Here we explore the potential of multi-modality imaging (DCE-MRI, ADC-MRI, and FDG-PET) to define the GTV for dose painting of pancreatic cancer. Volumetric variations of DCE-MRI, ADC-MRI and FDG-PET defined GTVs were assessed in comparison to the findings on CT, and to pathology specimens for resectable and borderline reseactable cases of pancreatic cancer. Methods: A total of 19 representative patients with DCE-MRI, ADC-MRI and FDG-PET data were analyzed. Of these, 8 patients had pathological specimens. GTV, inside pancreatic head/neck, or body, were delineated on MRI (denoted GTVDCE, and GTVADC), on FDG-PET using SUV of 2.5, 40% SUVmax, and 50% SUVmax (denoted GTV2.5, GTV40%, and GTV50%). A Kruskal-Wallis test was used to determine whether significant differences existed between GTV volumes. Results: Significant statistical differences were found between the GTVs defined by DCE-MRI, ADC-MRI, and FDG-PET, with a mean and range of 4.73 (1.00–9.79), 14.52 (3.21–25.49), 22.04 (1.00–45.69), 19.10 (4.84–45.59), and 9.80 (0.32–35.21) cm3 (p<0.0001) for GTVDCE, GTVADC, GTV2.5, GTV40%, and GTV50%, respectively. The mean difference and range in the measurements of maximum dimension of GTVs based on DCE-MRI, ADC-MRI, SUV2.5, 40% SUVmax, and 50% SUVmax compared with pathologic specimens were −0.84 (−2.24 to 0.9), 0.41 (−0.15 to 2.3), 0.58 (−1.41 to 3.69), 0.66 (−0.67 to 1.32), and 0.15 (−1.53 to 2.38) cm, respectively. Conclusion: Differences exists between DCE, ADC, and PET defined target volumes for RT of pancreatic cancer. Further studies combined with pathological specimens are required to identify the optimal imaging modality and/or acquisition method to define the GTV.

60 APPLIED LIFE SCIENCES↗

SU-E-I-97: Smart Auto-Planning Framework in An EMR Environment (SAFEE)

Purpose: Our Radiation Oncology Department uses clinical practice guidelines for patient treatment, including normal tissue sparing and other dosimetric constraints. These practice guidelines were adapted from national guidelines, clinical trials, literature reviews, and practitioner's own experience. Modern treatment planning systems (TPS) have the capability of incorporating these practice guidelines to automatically create radiation therapy treatment plans with little human intervention. We are developing a software infrastructure to integrate clinical practice guidelines and radiation oncology electronic medical record (EMR) system into radiation therapy treatment planning system (TPS) for auto planning. Methods: Our Smart Auto-Planning Framework in an EMR environment (SAFEE) uses a software pipeline framework to integrate practice guidelines,EMR, and TPS together. The SAFEE system starts with retrieving diagnosis information and physician's prescription from the EMR system. After approval of contouring, SAFEE will automatically create plans according to our guidelines. Based on clinical objectives, SAFEE will automatically select treatment delivery techniques (such as, 3DRT/IMRT/VMAT) and optimize plans. When necessary, SAFEE will create multiple treatment plans with different combinations of parameters. SAFEE's pipeline structure makes it very flexible to integrate various techniques, such as, Model-Base Segmentation (MBS) and plan optimization algorithms, e.g., Multi-Criteria Optimization (MCO). In addition, SAFEE uses machine learning, data mining techniques, and an integrated database to create clinical knowledgebase and then answer clinical questions, such as, how to score plan quality or how volume overlap affects physicians' decision in beam and treatment technique selection. Results: In our institution, we use Varian Aria EMR system and RayStation TPS from RaySearch, whose ScriptService API allows control by external programs. These applications are the building blocks of our SAFEE system. Conclusion: SAFEE is a feasible method of integrating clinical information to develop an auto-planning paradigm to improve clinical workflow in cancer patient care.

60 APPLIED LIFE SCIENCES↗

Controlling anisotropy in stereolithographically printed polymers

The ability to print three-dimensional objects was first developed in the 1980s and was originally strictly limited to polymeric materials. Through most of the intervening years, the approach has been thought of as a rapid prototyping method. This allowed low volume, high fidelity structures to be quickly fabricated to test things like fit and finish. However, more recently the term additive manufacturing has entered usage to represent the same methods and implies that the field is transitioning to creating finished parts. When we begin to think about these techniques as a real manufacturing approach, then the materials properties achieved during manufacture become much more important. This is true for all materials, as additive manufacturing has grown to encompass structures formed from metals and ceramics, however the bulk of work remains centered on polymers.

36 MATERIALS SCIENCE↗

Measuring representative volume elements from high-resolution grain-scale strain fields

Most crystalline materials present a highly heterogeneous response at the microscale, which can be affected by both internal factors (such as microstructural parameters) and external factors (such as loading). Relating microscale inhomogeneities to the macroscale response of a material requires the use of homogenisation techniques, usually based on the concept of a representative volume element (RVE)—the smallest volume of material that represents the global average response. Here, in this work, we present a new and robust experimental method of measuring the size of a strain-based RVE from high-resolution grain-scale strain fields obtained using digital image correlation (DIC). The proposed method is based on the statistical (stereological) nature of the RVE, which has been widely adopted in numerical studies, and involves dividing a strain field into randomly selected regions of varying sizes and statistically analysing the distributions of average strains within them. To validate the new method, we generate a large number of synthetic strain fields from a fractional Gaussian noise algorithm. The proposed stereological method is shown to be capable of producing reliable RVE measurements from a very large range of possible microscale strain fields while at the same time being robust in that it can produce RVE measurement results even in cases where other existing methods may be unable to do so. The proposed method has a low field-of-view requirement, only needing a field-of-view about 1.2 times as large as the RVE to produce reliable measurements. In addition, the stereological method offers significant flexibility since its statistical nature allows for control over how strict the RVE measurement should be in each case.

36 MATERIALS SCIENCE↗

Radiobiological Impact of Reduced Margins and Treatment Technique for Prostate Cancer in Terms of Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP)

Dose escalation in prostate radiotherapy is limited by normal tissue toxicities. The aim of this study was to assess the impact of margin size on tumor control and side effects for intensity-modulated radiation therapy (IMRT) and 3D conformal radiotherapy (3DCRT) treatment plans with increased dose. Eighteen patients with localized prostate cancer were enrolled. 3DCRT and IMRT plans were compared for a variety of margin sizes. A marker detectable on daily portal images was presupposed for narrow margins. Prescribed dose was 82 Gy within 41 fractions to the prostate clinical target volume (CTV). Tumor control probability (TCP) calculations based on the Poisson model including the linear quadratic approach were performed. Normal tissue complication probability (NTCP) was calculated for bladder, rectum and femoral heads according to the Lyman-Kutcher-Burman method. All plan types presented essentially identical TCP values and very low NTCP for bladder and femoral heads. Mean doses for these critical structures reached a minimum for IMRT with reduced margins. Two endpoints for rectal complications were analyzed. A marked decrease in NTCP for IMRT plans with narrow margins was seen for mild RTOG grade 2/3 as well as for proctitis/necrosis/stenosis/fistula, for which NTCP <7% was obtained. For equivalent TCP values, sparing of normal tissue was demonstrated with the narrow margin approach. The effect was more pronounced for IMRT than 3DCRT, with respect to NTCP for mild, as well as severe, rectal complications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comprehensive single-shot biophysical cytometry using simultaneous quantitative phase imaging and Brillouin spectroscopy

Abstract Single-cell analysis, or cytometry, is a ubiquitous tool in the biomedical sciences. Whereas most cytometers use fluorescent probes to ascertain the presence or absence of targeted molecules, biophysical parameters such as the cell density, refractive index, and viscosity are difficult to obtain. In this work, we combine two complementary techniques—quantitative phase imaging and Brillouin spectroscopy—into a label-free image cytometry platform capable of measuring more than a dozen biophysical properties of individual cells simultaneously. Using a geometric simplification linked to freshly plated cells, we can acquire the cellular diameter, volume, refractive index, mass density, non-aqueous mass, fluid volume, dry volume, the fractional water content of cells, both by mass and by volume, the Brillouin shift, Brillouin linewidth, longitudinal modulus, longitudinal viscosity, the loss modulus, and the loss tangent, all from a single acquisition, and with no assumptions of underlying parameters. Our methods are validated across three cell populations, including a control population of CHO-K1 cells, cells exposed to tubulin-disrupting nocodazole, and cells under hypoosmotic shock. Our system will unlock new avenues of research in biophysics, cell biology, and medicine.

Steelman, Zachary A.↗

High density plasmas and new diagnostics: An overview (invited)

One of the limiting factors for the full understanding of Electron Cyclotron Resonance Ion Sources (ECRISs) fundamental mechanisms consists of few types of diagnostic tools so far available for such compact machines. Microwave-to-plasma coupling optimisation, new methods of density overboost provided by plasma wave generation, and magnetostatic field tailoring for generating a proper electron energy distribution function, suitable for optimal ion beams formation, require diagnostic tools spanning across the entire electromagnetic spectrum from microwave interferometry to X-ray spectroscopy; these methods are going to be implemented including high resolution and spatially resolved X-ray spectroscopy made by quasi-optical methods (pin-hole cameras). The ion confinement optimisation also requires a complete control of cold electrons displacement, which can be performed by optical emission spectroscopy. Several diagnostic tools have been recently developed at INFN-LNS, including “volume-integrated” X-ray spectroscopy in low energy domain (2-30 keV, by using silicon drift detectors) or high energy regime (>30 keV, by using high purity germanium detectors). For the direct detection of the spatially resolved spectral distribution of X-rays produced by the electronic motion, a “pin-hole camera” has been developed also taking profit from previous experiences in the ECRIS field. The paper will give an overview of INFN-LNS strategy in terms of new microwave-to-plasma coupling schemes and advanced diagnostics supporting the design of new ion sources and for optimizing the performances of the existing ones, with the goal of a microwave-absorption oriented design of future machines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A modern concept of Lagrangian hydrodynamics

Here, we offer a modern interpretation of Lagrangian hydrodynamics as employed in Lagrangian simulations of compressible fluid flow. Our main result is to show that artificial viscosity, traditionally viewed as a numerical artifice to control unphysical oscillations in flows with shocks, actually represents a physical process and is necessary to derive accurate simulations in any compressible flow. We begin by reviewing the origins of two numerical devices, artificial viscosity and finite-volume methods. We proceed to construct a mathematical (PDE) model that incorporates those numerics and in which a new length scale, the observer, arises representing the discretization. Associated with that length scale, there are new inviscid fluxes that are the artificial viscosity as first formulated by Richtmyer and an artificial heat flux postulated by Noh but typically not included in Lagrangian codes. We discuss the connection of our results to bivelocity hydrodynamics. We conclude with some speculation as to the direction of future developments in multidimensional Lagrangian codes as computers get faster and have larger memories.

97 MATHEMATICS AND COMPUTING↗

High performance anode for advanced Li batteries

The overall objective of this Phase I SBIR effort was to advance the manufacturing technology for ASI’s Si-CNF high-performance anode by creating a framework for large volume production and utilization of low-cost Si-coated carbon nanofibers (Si-CNF) for the battery industry. This project explores the use of nano-structured silicon which is deposited on a nano-scale carbon filament to achieve the benefits of high cycle life and high charge capacity without the consequent fading of, or failure in the capacity resulting from stress-induced fracturing of the Si particles and de-coupling from the electrode. ASI’s patented coating process distinguishes itself from others, in that it is highly reproducible, readily scalable and results in a Si-CNF composite structure containing 25-30% silicon, with a compositionally graded interface at the Si-CNF interface that significantly improve cycling stability and enhances adhesion of silicon to the carbon fiber support. In Phase I, the team demonstrated the production of the Si-CNF anode material can successfully be transitioned from a static bench-scale reactor into a fluidized bed reactor. In addition, ASI made significant progress in the development of low cost, quick testing methods which can be performed on silicon coated CNFs as a means of quality control. To date, weight change, density, and cycling performance were the key metrics used to validate the high performance anode material. Under this effort, ASI made strides to establish a quality control protocol for the large volume production of Si-CNFs and has identified several key technical thrusts for future work. Using the results of this Phase I effort as a foundation, ASI has defined a path forward to commercialize and deliver high volume and low-cost production of SI-CNF material for anodes in Li-ion batteries.

25 ENERGY STORAGE↗

Cardiac C-arm computed tomography using a 3D + time ROI reconstruction method with spatial and temporal regularization

Purpose: Reconstruction of the beating heart in 3D + time in the catheter laboratory using only the available C-arm system would improve diagnosis, guidance, device sizing, and outcome control for intracardiac interventions, e.g., electrophysiology, valvular disease treatment, structural or congenital heart disease. To obtain such a reconstruction, the patient's electrocardiogram (ECG) must be recorded during the acquisition and used in the reconstruction. In this paper, the authors present a 4D reconstruction method aiming to reconstruct the heart from a single sweep 10 s acquisition. Methods: The authors introduce the 4D RecOnstructiOn using Spatial and TEmporal Regularization (short 4D ROOSTER) method, which reconstructs all cardiac phases at once, as a 3D + time volume. The algorithm alternates between a reconstruction step based on conjugate gradient and four regularization steps: enforcing positivity, averaging along time outside a motion mask that contains the heart and vessels, 3D spatial total variation minimization, and 1D temporal total variation minimization. Results: 4D ROOSTER recovers the different temporal representations of a moving Shepp and Logan phantom, and outperforms both ECG-gated simultaneous algebraic reconstruction technique and prior image constrained compressed sensing on a clinical case. It generates 3D + time reconstructions with sharp edges which can be used, for example, to estimate the patient's left ventricular ejection fraction. Conclusions: 4D ROOSTER can be applied for human cardiac C-arm CT, and potentially in other dynamic tomography areas. It can easily be adapted to other problems as regularization is decoupled from projection and back projection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Noncompliance With Radiation Therapy Protocol Guidelines and Operative Bed Recurrences for Children With Rhabdomyosarcoma and Microscopic Residual Disease: A Report From the Children's Oncology Group

Purpose: Postoperative radiation therapy (RT) is recommended for patients with rhabdomyosarcoma having microscopic disease. Sometimes RT dose/volume is reduced or omitted in an attempt to avoid late effects, particularly in young children. We reviewed operative bed recurrences to determine if noncompliance with RT protocol guidelines influenced local-regional control. Methods and Materials: All operative bed recurrences among 695 Group II rhabdomyosarcoma patients in Intergroup Rhabdomyosarcoma Study Group (IRS) I through IV were reviewed for deviation from RT protocol. Major/minor dose deviation was defined as >10% or 6-10% of the prescribed dose (40-60 Gy), respectively. Major/minor volume deviation was defined as tumor excluded from the RT field or treatment volume not covered by the specified margin (preoperative tumor volume and 2- to 5-cm margin), respectively. No RT was a major deviation. Results: Forty-six of 83 (55%) patients with operative bed recurrences did not receive the intended RT (39 major and 7 minor deviations). RT omission was the most frequent RT protocol deviation (19/46, 41%), followed by dose (17/46, 37%), volume (9/46, 20%), and dose and volume deviation (1/46, 2%). Only 7 operative bed recurrences occurred in IRS IV (5% local-regional failure) with only 3 RT protocol deviations. Sixty-three (76%) patients with recurrence died of disease despite retrieval therapy, including 13 of 19 nonirradiated children. Conclusion: Over half of the operative bed recurrences were associated with noncompliance; omission of RT was the most common protocol deviation. Three fourths of children die when local-regional disease is not controlled, emphasizing the importance of RT in Group II rhabdomyosarcoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Setup Errors in Image-Guided Radiotherapy for Head and Neck Cancer Patients Immobilized With a Custom-Made Device

Purpose: To evaluate the local positioning uncertainties during fractionated radiotherapy of head-and-neck cancer patients immobilized using a custom-made fixation device and discuss the effect of possible patient correction strategies for these uncertainties. Methods and Materials: A total of 45 head-and-neck patients underwent regular control computed tomography scanning using an in-room computed tomography scanner. The local and global positioning variations of all patients were evaluated by applying a rigid registration algorithm. One bounding box around the complete target volume and nine local registration boxes containing relevant anatomic structures were introduced. The resulting uncertainties for a stereotactic setup and the deformations referenced to one anatomic local registration box were determined. Local deformations of the patients immobilized using our custom-made device were compared with previously published results. Several patient positioning correction strategies were simulated, and the residual local uncertainties were calculated. Results: The patient anatomy in the stereotactic setup showed local systematic positioning deviations of 1-4 mm. The deformations referenced to a particular anatomic local registration box were similar to the reported deformations assessed from patients immobilized with commercially available Aquaplast masks. A global correction, including the rotational error compensation, decreased the remaining local translational errors. Depending on the chosen patient positioning strategy, the remaining local uncertainties varied considerably. Conclusions: Local deformations in head-and-neck patients occur even if an elaborate, custom-made patient fixation method is used. A rotational error correction decreased the required margins considerably. None of the considered correction strategies achieved perfect alignment. Therefore, weighting of anatomic subregions to obtain the optimal correction vector should be investigated in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modelling the complex evaporated gas flow and its impact on particle spattering during laser powder bed fusion

The additive manufacturing (AM) of metals is becoming an increasingly important production process with the potential to replace traditional techniques such as casting. Laser Powder Bed Fusion (LPBF) is used in many applications to print metal parts from powder. The metal powder is heated locally with sufficient laser radiation that the liquid melt easily reaches its boiling temperature, which leads to a metallic vapour jet that can entrain both powder bed particles and molten droplets. The small size of laser-matter interaction site makes a detailed experimental analysis of the process challenging. Synchrotron X-ray imaging experiments are one of the few methods which can capture the dynamic melting and solidification processes. Comparing such experiments with computer simulations of the process is an important approach in order to better understand the manufacturing process and to analyse the influence of process parameters on the evaporated gas jet and the subsequent impact on particle ejection, leading to potentially reduced AM component quality. The melting and solidification of the metal powder is simulated using an Eulerian multiphase approach based on a control volume discretization of powder bed and substrate and a volume of liquid separation from melt and gas phase. The gas phase modelled as an ideal gas reaches velocities up to 100 m/s. Lagrangian particle tracking in the simulation demonstrates that the velocity fields calculated by the Eulerian multi-phase approach in combination with a standard drag-force model lead to particle accelerations in good agreement with those measured experimentally. In order to avoid numerical laborious Lagrangian calculations, a direct method to compare an Eulerian multiphase simulation with synchrotron X-ray experiments was introduced and validated. This approach is used to analyse the influence of process parameters including laser power and laser speed on the maximal acceleration of particles from the melt pool area. While the particle acceleration increases linearly with line energy in the conduction mode, a linear decrease of the acceleration with increasing line energy can be found in the transition mode before the accel-eration increases again with line energy in the keyhole mode.

36 MATERIALS SCIENCE↗

Improved electrochemical cycling stability of intercalation battery electrodes via control of material morphology

Using a model tunnel manganese oxide with the todorokite crystal structure (T-MnO 2 ), we reveal that controlling the morphology of the active material can improve the cycling stability of intercalation battery electrodes. The T-MnO 2 structure is built from tunnels that provide spacious 1D diffusion channels for charge-carrying ions. Taking advantage of the unique ability to synthesize T-MnO 2 in the form of both highly crystalline two-dimensional (2D) nanoplatelets and one-dimensional (1D) nanowires through a facile hydrothermal growth method, we investigated the effect of nanoscale particle dimensions on reversible battery cycling. Insertion of ions into the tunnels results in anisotropic expansion of the structure, making T-MnO 2 with different morphologies an excellent model platform to understand how intercalation-induced volume change, typically leading to the deterioration of the electrode performance over extended cycling, can be controlled through synthesis of targeted morphologies. T-MnO 2 nanowires showed not only significantly improved capacity retention but also substantially higher specific capacity than the T-MnO 2 nanoplatelets. The enhanced electrochemical properties of the nanowire electrodes could be attributed to the larger surface-to-volume ratio than that of nanoplatelets, resulting in higher contact area with electrolyte for the nanowires. Moreover, due to the smaller cross-sectional area of the nanowires, volume expansion and contraction perpendicular to the structural tunnels induced by reversible ion intercalation occurs in a more facile fashion. In this research we demonstrate that chemically controlling morphology and producing particles with nanostructure dimensionality replicating that of atomic structure (i.e., 1D morphology and 1D structure) makes it possible to enhance material performance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

MR-guided Periarterial Ethanol Injection for Renal Sympathetic Denervation: A Feasibility Study in Pigs

Purpose. To evaluate the feasibility and efficacy of image-guided periarterial ethanol injection as an alternative to transluminal radiofrequency ablation. Methods. Unilateral renal periarterial ethanol injection was performed under general anesthesia in 6 pigs with the contralateral kidney serving as control. All interventions were performed in an open 1.0 T MRI system under real-time multiplanar guidance. The injected volume was 5 ml (95 % ethanol labelled marked MR contrast medium) in 2 pigs and 10 ml in 4 pigs. Four weeks after treatment, the pigs underwent MRI including MRA and were killed. Norepinephrine (NE) concentration in the renal parenchyma served as a surrogate parameter to analyze the efficacy of sympathetic denervation. In addition, the renal artery and sympathetic nerves were examined histologically to identify evidence of vascular and neural injury. Results. In pigs treated with 10 ml ethanol, treatment resulted in neural degeneration. We found a significant reduction of NE concentration in the kidney parenchyma of 53 % (p < 0.02) compared with the untreated contralateral kidney. In pigs treated with 5 ml ethanol, no significant changes in histology or NE were observed. There was no evidence of renal arterial stenosis in MRI, macroscopy or histology in any pig. Conclusion. MR-guided periarterial ethanol injection was feasible and efficient for renal sympathetic denervation in a swine model. This technique may be a promising alternative to the catheter-based approach in the treatment of resistant arterial hypertension.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An experimental system and procedure of unsteady-state relative permeability test for gas hydrate-bearing sediments

Reliable estimations of the relative permeability of gas and water in hydrate-bearing sediments (HBS) and the dependency of the relative permeability on hydrate saturation are critical to predict the productivity of a hydrate reservoir. Yet, this remains poorly estimated owing to lack of experimental data associated with difficulties in conducting multiphase flow experiments in HBS. Recognizing the experimental challenges, this study intends to develop and validate a new experimental system and procedure of unsteady-state relative permeability test that can generate reliable and reproducible flow measurements in HBS. Furthermore, gas hydrate is considered as a part of solid matrix in the sediment, so one of the challenges is to maintain a constant hydrate saturation, which is achieved in this experimental study using tight pressure-temperature (P-T) control near the hydrate stability boundary. The measured differential pressure across the specimen, methane injection flow rate, and volume of displaced brine are used to calculate the relative permeability by adopting a conventional Buckley-Leverett theory-based interpretation method. Residual brine saturation calculated for the hydrate-bearing specimen is higher than that of hydrate-free specimen, presumably due to decrease in pore size, increase in heterogeneity of solid matrix, and increase in size distribution of solid matrix and pore in the presence of hydrates. Further studies are necessary to represent the results of the unsteady-state flow experiment in HBS with a gas hydrate-dependent relative permeability model.

03 NATURAL GAS↗

Factors controlling pore network development of thermally mature Early Palaeozoic mudstones from the Baltic Basin (N Poland)

Understanding the formation of pore space, especially in low porosity shales (as source rocks and as unconventional resources), is critical to the oil and gas industry, since pores control the space available for hydrocarbon and participate in hydrocarbon transport. We examined 87 Ordovician and Silurian mudstone samples collected from four wells located in the Pomeranian part of the Baltic Basin (northern Poland), one of the primary Polish targets for hydrocarbon exploration. These samples represent the Pelplin, the Paslek, the Jantar, the Prabuty, and the Sasino Formations, which still requires more detailed porosity studies. Our study aimed to identify factors controlling porosity development, by applying bulk techniques (organic petrology and TOC analyses, quantitative mineralogy, and porosimetry) as well as nano- to microscale techniques (thin section petrography, electron microscopy). The studied samples are mainly argillaceous mudstones. The results of porosimetry measurements, combined with image analysis, indicate that the pores of all studied rocks are dominated by micropores (pores < 2 nm in diameter), mesopores (2-50 nm in diameter) and small macropores. The SEM images showed three main pore types: a) voids related to clay mineral aggregates, b) pores inside organic matter particles, and c) pores between other mineral grains. In the Jantar and Sasino mudstones, the organic matter content and its thermal maturity control porosity. The occurrence of solid bitumen in the rocks from these formations reduces samples’ mesoporosity because of the pore-clogging effect. In contrast, in the Paslek and Prabuty Formations, there is low organic matter content and specific surface area and the volume of mesopores increase with clay minerals content. In the Pelplin mudstones, there are no prevailing factors controlling porosity. As a result, we suggest that a combination of SEM image analysis and dual liquid porosity (DLP) measurements is a powerful method to assess porosity available for petroleum flow in mudstones.

03 NATURAL GAS↗