Search NASA⌕ Search

SEARCH · Search NASA

Results for “controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Simultaneous control of the electron temperature and safety factor profiles in DIII-D using model-based optimal control techniques

Future tokamak power plants will likely operate using a single, well-defined plasma scenario, either in steady state or for very long pulse lengths. In order to enhance the robustness of the scenario, feedback controllers for a variety of plasma properties will be necessary to counteract any disturbances and ensure safe operation. However, only a limited set of actuators will be available to control many different quantities. Because of this, it is necessary to develop controllers that are able to regulate multiple plasma properties using a limited set of actuators. To this end, a controller has been developed for the simultaneous regulation of both the electron temperature and safety factor profiles in DIII-D. This algorithm uses a linear quadratic integral control synthesis approach based on a linearized model of the dynamics of the two profiles. Two neural network surrogate models, NubeamNet and MMMnet, are included to improve the fidelity of the model. Furthermore, the controller has been tested in simulation using COTSIM, and has demonstrated the ability to simultaneously track changes in both the electron temperature and safety factor targets, including changes in both the magnitude and the shape of the profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Controllable X-ray Pulse Trains from Enhanced Self-Amplified Spontaneous Emission

We report the demonstration of optical compression of an electron beam and the production of controllable trains of femtosecond, soft x-ray pulses with the Linac Coherent Light Source (LCLS) freeelectron laser (FEL). This is achieved by enhanced self-amplified spontaneous emission with a 2 μm laser and a dechirper device. Optical compression was achieved by modulating the energy of an electron beam with the laser and then compressing with a chicane, resulting in high current spikes on the beam which we observe to lase. A dechirper was then used to selectively control the lasing region of the electron beam. Field autocorrelation measurements indicate a train of pulses, and we find that the number of pulses within the train can be controlled (from 1 to 5 pulses) by varying the dechirper position and undulator taper. These results are a step toward attosecond spectroscopy with x-ray FELs as well as future FEL schemes relying on optical compression of an electron beam.

Duris, Joseph P↗

On Stability of PQ-Controlled Grid-Following and Droop-Control Grid-Forming Inverters

In this paper, the nonlinearity impacts of PQ-control schemes and LCL filter parameter variations on the stability of grid-interactive inverters are studied under weak grid conditions. This work demonstrates that the control nonlinearity and parameter variations can cause unexpected instability at low power levels. This instability issue in the nominal operating range may occur under specific control parameters due to the shift of the low-frequency eigenvalues of PQ-controlled inverters. A full-order small-signal model for PQ-controlled inverters is applied to analyze this instability issue. Furthermore, the impacts of the droop coefficients on the stability of the droop-controlled grid-forming inverter are also investigated using the closed-loop inverter model. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator and a hardware setup of a microgrid fed by two 5 kVA 208V inverters.

Hossen, Tareq↗

Model Predictive Control-based Optimal Coordination of Distributed Energy Resources

Distributed energy resources, such as renewable energy resources (wind, solar), energy storage and demand response, can be used to complement conventional generators. The uncertainty and variability due to high penetration of wind makes reliable system operations and controls challenging, especially in isolated systems. In this paper, an optimal control strategy is proposed to coordinate energy storage and diesel generators to maximize wind penetration while maintaining system economics and normal operation performance. The goals of the optimization problem are to minimize fuel costs and maximize the utilization of wind while considering equipment life of generators and energy storage. Model predictive control (MPC) is used to solve a look-ahead dispatch optimization problem and the performance is compared to an open loop look-ahead dispatch problem. Simulation studies are performed to demonstrate the efficacy of the closed loop MPC in compensating for uncertainties and variability caused in the system.

Mayhorn, Ebony T.↗

Model Predictive Control-Based Trajectory Shaper for Safe and Efficient Adaptive Cruise Control

Recent studies show that commercially-available adaptive cruise control (ACC) systems are string-unstable, indicating that ACC-driven vehicles amplify speed fluctuations from downstream traffic and induce stop-and-go waves. Moreover, it is challenging to revise the original control algorithm of an ACC system to achieve string stability due to its internal complexity and powertrain uncertainties. To achieve desired control performance given a string-unstable ACC system and circumvent revising the original control algorithm, this study proposes a model predictive control-based trajectory shaper (MPC-TS), which only modifies the sensor-measured trajectory information (i.e., position and speed) of the preceding vehicle. The proposed MPC-TS leverages the input shaping technique to generate reference trajectory to improve string stability, while incorporating tracking errors and vehicle acceleration/deceleration magnitude in the MPC cost function and constraining fluctuations of vehicle speed and spacing to ensure desired car-following performance. Numerical experiments validate the control performance of ACC with the proposed MPC-TS in terms of string stability, safety, traffic efficiency, and comfort.

Zhou, Anye↗

Experimental Evidence on Latency in a Fleet of Controllable Water Heaters

Demand response is an important emerging part of smart grids with wide coverage in theoretical and modeling research. However, experimental evidence on the real-life behavior of controllable loads is still limited. We present observations regarding latency and communication aspects of the operation on a fleet of residential water heaters in a smart neighborhood in Atlanta, GA. Our analysis shows that latency in water heaters is not constant and does not follow a Gaussian distribution. We also find that there is a systematic relationship between latency and hour of the day. Latency was found to increase during morning and evening hours compared to the afternoon. These findings could help better plan deployment of control for demand response programs. Understanding delays associated with controlling smart devices is crucial for proper design and algorithm development for optimization, frequency of dispatch, and override detection.

communication delay↗

Turbine Control of a Tidal and River Power Generator

As renewable generation has become less expensive during recent decades, and it becomes more accepted by the global population, the focus on renewable generation has expanded to include new types with promising future applications, such as river and tidal generation. The input variations to these types of resources are slower but also steadier than wind or solar generation. The level of water turbulent flow may vary from one place to another, however, the control algorithm can be adjusted to local environment. This paper describes the hydrokinetic aspects of river and tidal generation based on a river and tidal generator. Although the information given in this paper is not that of an exact generator deployed on site, the data used is representative of a typical river or tidal generator. In this paper, the hydrokinetic and associated electrical controller of the system were not included; however, the focus of this paper is on the hydrodynamic control.

13 HYDRO ENERGY↗

Using Synchronization as an Indicator of Controllability in a Fleet of Water Heaters

Peak reduction is an important concern that can help reduce the growing stress on distribution grid and allow to defer investments in new capacity. However, the growing concern for customer privacy and comfort may impact the performance of load control for residential devices. Water heaters represent a convenient way of reducing peak due to their ability to store thermal energy for future use. In this paper, we developed a methodology to help utilities gain more insight with respect to the impact of load control efforts for shaving peak with no necessary information about the water heaters except the device status (on/off). To this end, we use a fleet of water heaters in a controlled residential neighborhood in Atlanta, GA. Our findings show that convergence in device status can serve as a proxy for peak shifting during hours of the evening peak.

demand response↗

A 100-kW 1300-MHz Magnetron With Amplitude and Phase Control for Accelerators

Calabazas Creek Research, Inc. (CCR), in collaboration with Fermilab and Communications and Power Industries, LLC (CPI), developed a 100-kW peak, 10-kW average, 1300-MHz, magnetron-based, RF system with amplitude and phase control for driving accelerators. Phase locking was achieved using an approach originated at Fermilab that uses phase modulation of the locking signal to control the amplitude and phase into a superconducting cavity on a fast time scale. Experimental results, including demonstration of phase locking and amplitude control, are reported.

43 PARTICLE ACCELERATORS↗

Modern control system applications at Fermilab with Dart and Flutter

The control system at Fermilab is undergoing an unprecedented modernization effort. Hundreds of legacy applications originally developed with technology from the early nineties will be replaced with a suite of modern web applications. The selection of an user interface framework is a key technology decision that will impact on all the applications developed over the next decade. The Controls department at Fermilab has decided to use Google’s Dart language and Flutter framework for future application development. In this paper we will discuss the decision process that selected Dart/Flutter and the development of early general purpose control system applications with the framework.

Diamond, John [Fermilab]↗

Reaction Between Thin Gold Wires and Pb-Sn-In Solder (37.5%, 37.5%, 25%), Part C: A comprehensive Model of the Reaction Inside the Solder Mounds in Both the "Interface Controlled Regime" and the "Diffusion-Controlled" Regime During Long-Term Exposure

In part A, all available literature data are displayed in tables, and plotted in figure 1. The slopes of the lines through the data in figure 1 suggest that there is a change in the rate controlling mechanism from interface control (linear with time, slope equals one in figure 1) to diffusion control (proportional to square root of time, slope one half in figure 1) as the gold consumption increases. Here we develop a model for the diffusion controlled reaction using data from planar and circular geometry. We determine the regimes in time and temperature where the reaction is diffusion controlled and where it is interface controlled, and then derive the set of equations for a comprehensive time and temperature dependent model that describes the reaction for all temperatures and time.

36 MATERIALS SCIENCE↗

Power Flow Controller for Renewables: Transformer-less Unified Power Flow Controller for Wind and Solar Power Transmission

GENI Project: MSU is developing a power flow controller to improve the routing of electricity from renewable sources through existing power lines. The fast, innovative, and lightweight circuitry that MSU is incorporating into its controller will eliminate the need for a separate heavy and expensive transformer, as well as the construction of new transmission lines. MSU’s controller is better suited to control power flows from distributed and intermittent wind and solar power systems than traditional transformer-based controllers are, so it will help to integrate more renewable energy into the grid. MSU‘s power flow controller can be installed anywhere in the existing grid to optimize energy transmission and help reduce transmission congestion.

ARPA-E↗

Controllable Grid Interface for Testing Ancillary Service Controls and Fault Performance of Utility-Scale Wind Power Generation: Preprint

The rapid expansion of wind power has led many transmission system operators to demand modern wind power plants to comply with strict interconnection requirements. Such requirements involve various aspects of wind power plant operation, including fault ride-through and power quality performance as well as the provision of ancillary services to enhance grid reliability. During recent years, the National Renewable Energy Laboratory (NREL) of the U.S. Department of Energy has developed a new, groundbreaking testing apparatus and methodology to test and demonstrate many existing and future advanced controls for wind generation (and other renewable generation technologies) on the multimegawatt scale and medium-voltage levels. This paper describes the capabilities and control features of NREL's 7-MVA power electronic grid simulator (also called a controllable grid interface, or CGI) that enables testing many active and reactive power control features of modern wind turbine generators -- including inertial response, primary and secondary frequency responses, and voltage regulation -- under a controlled, medium-voltage grid environment. In particular, this paper focuses on the specifics of testing the balanced and unbalanced fault ride-through characteristics of wind turbine generators under simulated strong and weak medium-voltage grid conditions. In addition, this paper provides insights on the power hardware-in-the-loop feature implemented in the CGI to emulate (in real time) the conditions that might exist in various types of electric power systems under normal operations and/or contingency scenarios. Using actual test examples and simulation results, this paper describes the value of CGI as an ultimate modeling validation tool for all types of 'grid-friendly' controls by wind generation.

17 WIND ENERGY↗

Supervisory-level control system demand control of an HVAC system

A supervisory-level control system is provided and includes a summation unit receptive of first and second signals, an HVAC system to generate the second signal according to first set-point signals and to a second set-point signal and a supervisory controller. The supervisory controller includes a control unit, a set-point scheduler and a zone level set-point distribution unit. The control unit is receptive of an error signal representing a difference between the first and second signals from the summation unit. The set-point scheduler is receptive of a demand signal generated by the control unit according to the error signal. The set-point scheduler generates a set-point command signal and the second set-point signal according to the demand signal. The zone level set-point distribution unit is configured to generate the first set-point signals in accordance with the set-point command signal.

Adetola, Veronica↗

Tutorial of Wind Turbine Control for Supporting Grid Frequency through Active Power Control: Preprint

As wind energy becomes a larger portion of the world's energy portfolio and wind turbines become larger and more expensive, wind turbine control systems play an ever more prominent role in the design and deployment of wind turbines. The goals of traditional wind turbine control systems are maximizing energy production while protecting the wind turbine components. As more wind generation isinstalled there is an increasing interest in wind turbines actively controlling their power output in order to meet power setpoints and to participate in frequency regulation for the utility grid. This capability will be beneficial for grid operators, as it seems possible that wind turbines can be more effective at providing some of these services than traditional power plants. Furthermore,establishing an ancillary market for such regulation can be beneficial for wind plant owner/operators and manufacturers that provide such services. In this tutorial paper we provide an overview of basic wind turbine control systems and highlight recent industry trends and research in wind turbine control systems for grid integration and frequency stability.

17 WIND ENERGY↗

Inertial Response of Wind Power Plants: A Comparison of Frequency-Based Inertial Control and Stepwise Inertial Control

The frequency regulation capability of a wind power plant plays an important role in enhancing frequency reliability especially in an isolated power system with high wind power penetration levels. A comparison of two types of inertial control methods, namely frequency-based inertial control (FBIC) and stepwise inertial control (SIC), is presented in this paper. Comprehensive case studies are carried out to reveal features of the different inertial control methods, simulated in a modified Western System Coordination Council (WSCC) nine-bus power grid using real-time digital simulator (RTDS) platform. The simulation results provide an insight into the inertial control methods under various scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Theoretical Control-Centric Modeling for Precision Model-Based Sliding Mode Control of a Hydraulic Artificial Muscle Actuator

Artificial muscles (AMs) typically rely on pneumatic sources of fluid power. The use of hydraulics can increase the power and force to weight and volume ratios of AM actuators. This paper develops a control-centric third-order single-input single-output (SISO) lumped-parameter dynamic model and sliding mode position controller based on Filippov's principle of equivalent dynamics for a braided hydraulic artificial muscle (HAM) actuator. The model predicts the nonlinear behavior of the HAM free contraction and captures the fluid and actuator nonlinear dynamic interactions in addition to the braid deformation. Model simulations are compared to experimental results for quasi-static pressurization, isometric pressurization, and open-loop square wave commands at 0.25, 0.5, and 1 Hz. Experiments of sine wave tracking at 0.25, 0.5, and 1 Hz and continuous square wave tracking at 0.067 Hz are conducted using a sliding mode controller (SMC) derived from the model. The SMC achieves a steady-state error of 6 μm at multiple setpoints within the actuator's 17 mm stroke. Compared to a proportional-integral-derivative (PID) controller, the SMC root-mean-square (RMS) error, mean error, and absolute maximum error are reduced on average by 53%, 61%, and 44%, respectively, demonstrating the benefit of model-based approaches for controlling HAMs.

42 ENGINEERING↗

Agent-based Cyber Control Strategy Design for Resilient Control Systems: Concepts, Architecture and Methodologies

The implementation of automated regulatory control has been around since the middle of the last century through analog means. It has allowed engineers to operate the plant more consistently by focusing on overall operations and settings instead of individual monitoring of local instruments (inside and outside of a control room). A similar approach is proposed for cyber security, where current border-protection designs have been inherited from information technology developments that lack consideration of the high-reliability, high consequence nature of industrial control systems. Instead of an independent development, however, an integrated approach is taken to develop a holistic understanding of performance. This performance takes shape inside a multiagent design, which provides a notional context to model highly decentralized and complex industrial process control systems, the nervous system of critical infrastructure. The resulting strategy will provide a framework for researching solutions to security and unrecognized interdependency concerns with industrial control systems.

47 OTHER INSTRUMENTATION↗