Search NASA⌕ Search

SEARCH · Search NASA

Results for “controller area network”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Automated Demand Response: The Missing Link in the Electricity Value Chain

In 2006, the Public Interest Energy Research Program (PIER) Demand Response Research Center (DRRC) at Lawrence Berkeley National Laboratory initiated research into Automated Demand Response (OpenADR) applications in California industry. The goal is to improve electric grid reliability and lower electricity use during periods of peak demand. The purpose of this research is to begin to define the relationship among a portfolio of actions that industrial facilities can undertake relative to their electricity use. This ?electricity value chain? defines energy management and demand response (DR) at six levels of service, distinguished by the magnitude, type, and rapidity of response. One element in the electricity supply chain is OpenADR, an open-standards based communications system to send signals to customers to allow them to manage their electric demand in response to supply conditions, such as prices or reliability, through a set of standard, open communications. Initial DRRC research suggests that industrial facilities that have undertaken energy efficiency measures are probably more, not less, likely to initiate other actions within this value chain such as daily load management and demand response. Moreover, OpenADR appears to afford some facilities the opportunity to develop the supporting control structure and to"demo" potential reductions in energy use that can later be applied to either more effective load management or a permanent reduction in use via energy efficiency. Under the right conditions, some types of industrial facilities can shift or shed loads, without any, or minimal disruption to operations, to protect their energy supply reliability and to take advantage of financial incentives.1 In 2007 and 2008, 35 industrial facilities agreed to implement OpenADR, representing a total capacity of nearly 40 MW. This paper describes how integrated or centralized demand management and system-level network controls are linked to OpenADR systems. Case studies of refrigerated warehouses and wastewater treatment facilities are used to illustrate OpenADR load reduction potential. Typical shed and shift strategies include: turning off or operating compressors, aerator blowers and pumps at reduced capacity, increasing temperature set-points or pre-cooling cold storage areas and over-oxygenating stored wastewater prior to a DR event. This study concludes that understanding industrial end-use processes and control capabilities is a key to support reduced service during DR events and these capabilities, if DR enabled, hold significant promise in reducing the electricity demand of the industrial sector during utility peak periods.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Automated Demand Response: The Missing Link in the Electricity Value Chain

In 2006, the Public Interest Energy Research Program (PIER) Demand Response Research Center (DRRC) at Lawrence Berkeley National Laboratory initiated research into Automated Demand Response (OpenADR) applications in California industry. The goal is to improve electric grid reliability and lower electricity use during periods of peak demand. The purpose of this research is to begin to define the relationship among a portfolio of actions that industrial facilities can undertake relative to their electricity use. This 'electricity value chain' defines energy management and demand response (DR) at six levels of service, distinguished by the magnitude, type, and rapidity of response. One element in the electricity supply chain is OpenADR, an open-standards based communications system to send signals to customers to allow them to manage their electric demand in response to supply conditions, such as prices or reliability, through a set of standard, open communications. Initial DRRC research suggests that industrial facilities that have undertaken energy efficiency measures are probably more, not less, likely to initiate other actions within this value chain such as daily load management and demand response. Moreover, OpenADR appears to afford some facilities the opportunity to develop the supporting control structure and to 'demo' potential reductions in energy use that can later be applied to either more effective load management or a permanent reduction in use via energy efficiency. Under the right conditions, some types of industrial facilities can shift or shed loads, without any, or minimal disruption to operations, to protect their energy supply reliability and to take advantage of financial incentives. In 2007 and 2008, 35 industrial facilities agreed to implement OpenADR, representing a total capacity of nearly 40 MW. This paper describes how integrated or centralized demand management and system-level network controls are linked to OpenADR systems. Case studies of refrigerated warehouses and wastewater treatment facilities are used to illustrate OpenADR load reduction potential. Typical shed and shift strategies include: turning off or operating compressors, aerator blowers and pumps at reduced capacity, increasing temperature set-points or pre-cooling cold storage areas and over-oxygenating stored wastewater prior to a DR event. This study concludes that understanding industrial end-use processes and control capabilities is a key to support reduced service during DR events and these capabilities, if DR enabled, hold significant promise in reducing the electricity demand of the industrial sector during utility peak periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Risk Analysis for Remote Operation of Microreactors

Microreactors are a subset of advanced nuclear reactors that can be factory fabricated, transportable, and self-regulating. They have the potential to be used in microgrids, rural and remote areas, or emergency response applications, replacing fossil fuel sources like diesel generators and enabling sustainable energy generation. In order to make microreactor operation cost-effective, it is likely that remote communications will be needed to reduce the number of personnel required to be on site. While remote operation of energy generation and other industrial control systems is common in other industries, it is not yet adopted in the nuclear community and has many perceived and actual risks. In this paper, the severity of the risks introduced by remote operations for microreactors are explored. The primary changes in the operations involve the addition of a remote communications network and a certification system for data and controls. These changes lend themselves to considerations of cyber risks, whether unintentional or adversarial, but the assessment considers not just cyber risks introduced, but also how physical and human factors-based risks will impact the remote operations system and change the overall risk profile. This initial assessment indicates that there are standard cyber and mitigation measures that can be put in place so the risk of doing remote operations does not dramatically increase compared to local operations. This evaluation is a critical step in the process of evaluating if remote operations of microreactors is a suitable solution to meet future sustainable grid needs

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive Image-Guided Radiotherapy (IGRT) Eliminates the Risk of Biochemical Failure Caused by the Bias of Rectal Distension in Prostate Cancer Treatment Planning: Clinical Evidence

Purpose: Rectal distension has been shown to decrease the probability of biochemical control. Adaptive image-guided radiotherapy (IGRT) corrects for target position and volume variations, reducing the risk of biochemical failure while yielding acceptable rates of gastrointestinal (GI)/genitourinary (GU) toxicities. Methods and Materials: Between 1998 and 2006, 962 patients were treated with computed tomography (CT)-based offline adaptive IGRT. Patients were stratified into low (n = 400) vs. intermediate/high (n = 562) National Comprehensive Cancer Network (NCCN) risk groups. Target motion was assessed with daily CT during the first week. Electronic portal imaging device (EPID) was used to measure daily setup error. Patient-specific confidence-limited planning target volumes (cl-PTV) were then constructed, reducing the standard PTV and compensating for geometric variation of the target and setup errors. Rectal volume (RV), cross-sectional area (CSA), and rectal volume from the seminal vesicles to the inferior prostate (SVP) were assessed on the planning CT. The impact of these volumetric parameters on 5-year biochemical control (BC) and chronic Grades {>=}2 and 3 GU and GI toxicity were examined. Results: Median follow-up was 5.5 years. Median minimum dose covering cl-PTV was 75.6 Gy. Median values for RV, CSA, and SVP were 82.8 cm{sup 3}, 5.6 cm{sup 2}, and 53.3 cm{sup 3}, respectively. The 5-year BC was 89% for the entire group: 96% for low risk and 83% for intermediate/high risk (p < 0.001). No statistically significant differences in BC were seen with stratification by RV, CSA, and SVP in quartiles. Maximum chronic Grades {>=}2 and 3 GI toxicities were 21.2% and 2.9%, respectively. Respective values for GU toxicities were 15.5% and 4.3%. No differences in GI or GU toxicities were noted when patients were stratified by RV. Conclusions: Incorporation of adaptive IGRT reduces the risk of geometric miss and results in excellent biochemical control that is independent of rectal volume/distension while maintaining very low rates of chronic GI toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Groundwater Protection Program Management Plan For The U.S. Department Of Energy Y-12 National Security Complex, Oak Ridge, Tennessee

This document presents the Groundwater Protection Program (GWPP) management plan for the U.S. Department of Energy (DOE) Y-12 National Security Complex (hereafter referenced as Y-12). The Y-12 GWPP functions as the primary point-of-contact for groundwater-related issues at Y-12, provides stewardship of the extensive network of groundwater monitoring wells at Y-12, and serves as a resource for technical expertise, support, and historical data for groundwater-related activities at Y-12. These organizational functions each serve the primary programmatic purpose of the GWPP, which is to ensure that groundwater monitoring activities within areas under Y-12 administrative control provide representative data in compliance with the multiple purposes of applicable state and federal regulations, DOE orders, and the corporate policies of Babcock & Wilcox Technical Services Y-12 LLC (hereafter referenced as B&W Y-12), the Y-12 management and operations (M&O) contractor for DOE. B&W Y-12 is a new corporate name, assumed in January 2007, for the company formerly known as BWXT Y-12, L.L.C., hereafter referenced as BWXT. This GWPP management plan addresses the requirements of DOE Order 450.1A Environmental Protection Program (hereafter referenced as DOE O 450.1A), which emphasize a site-wide approach for groundwater protection at each DOE facility through implementation of groundwater surveillance monitoring. Additionally, this plan addresses the relevant and applicable GWPP elements and goals described in the DOE O 450.1A technical guidance documents issued in June 2004 (DOE 2004) and May 2005 (DOE 2005). This GWPP management plan is a &#x27;living&#x27; document that is reviewed annually, revised and reissued every three years, and is formatted to provide for updating individual sections independent of the rest of the document. Section 2 includes a short description of the groundwater system at Y-12, the history of groundwater monitoring at Y-12 and the corresponding evolution of the GWPP, and an overview of ongoing Y-12 groundwater monitoring activities. Section 3 describes the key elements of the GWPP management strategy. Organizational roles and responsibilities of GWPP personnel are outlined in Section 4. Section 5 presents an overview of the GWPP project plans for applicable programmatic elements. Section 6 lists the reports, plans, and documents that are referenced for technical and administrative details.

54 ENVIRONMENTAL SCIENCES↗

Consensus-Based Control and Optimization of Power System Inertia

The integration of distributed energy resources (DERs), such as solar, wind, and energy storage systems, into power grids through inverter-based resources reduces power system inertia, leading to faster frequency dynamics and potential grid instability. To address this challenge, this paper proposes a distributed, consensus-based approach for the real-time control and optimization of inertia sources (synchronous generators and/or DERs) during system disturbances, enhancing both system stability and economic performance. The distributed control and optimization approach assumes each inertia source exchanges information solely with its neighbor ones, making it easily scalable to large power grid networks. The impacts of the communication connectivity among the inertia sources as well as their generation capacity limits on the distributed approach are investigated. We also demonstrate the approach’s robustness in scenarios involving communication time delays and packet losses, validating its effectiveness through numerical simulations on a 4-bus test system and a two-area 8-bus test system.

Power system inertia↗

2013 Groundwater Monitoring Report, Central Nevada Test Area Subsurface Corrective Action Unit 443

The Central Nevada Test Area was the site of a 0.2- to 1-megaton underground nuclear test in 1968. The surface of the site has been closed, but the subsurface is still in the corrective action process. The corrective action alternative selected for the site was monitoring with institutional controls. Annual sampling and hydraulic head monitoring of the well network are conducted as part of the subsurface corrective action strategy for the site. The monitoring well network was enhanced in 2013 with the installation of a new well MV-6. The site is currently in the fifth year of the 5-year proof-of-concept monitoring period. Analytical results from the 2013 monitoring are consistent with those of previous years indicating no tritium or 14 C concentrations above the required detection limits. Water level data from new wells MV-4 and MV-5 and recompleted well HTH-1RC indicate that hydraulic heads are still recovering from installation and testing. Data from wells MV-4 and MV-5 also indicate that head levels have not yet recovered from the 2011 sampling event during which several thousand gallons of water were purged. Low-flow bladder pumps were installed during the November 2013 sampling event to reduce the well purge volumes and the impact purging has on the water levels during sampling. The new bladder pumps allow the collection of groundwater samples using the low-flow sampling method and will allow head levels to recover to steadystate conditions. Despite the lack of steady-state groundwater conditions, hydraulic head data collected from site continue to support the conceptual model that the southeast-bounding graben fault acts as a barrier to groundwater flow at the site.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

2014 Groundwater Monitoring Report Central Nevada Test Area Subsurface Corrective Action Unit 443

The Central Nevada Test Area was the site of a 0.2- to 1-megaton underground nuclear test in 1968. The surface of the site has been closed, but the subsurface is still in the corrective action process. The corrective action alternative selected for the site was monitoring with institutional controls. Annual sampling and hydraulic head monitoring of the well network are conducted as part of the subsurface corrective action strategy for the site. The monitoring well network consists of 12 locations (wells and piezometers) in the alluvium, seven locations (wells and piezometers) in the volcanic section, and one well in the collapse chimney that resulted from the underground nuclear test. The site is currently in the conceptual model evaluation phase of the corrective action strategy.

54 ENVIRONMENTAL SCIENCES↗

In Silico Insights into Protein–Protein Interaction Disruptive Mutations in the PCSK9-LDLR Complex

Gain-of-function mutations in PCSK9 (proprotein convertase subtilisin/kexin type 9) lead to reduced uptake of LDL (low density lipoprotein) cholesterol and, therefore, increased plasma LDL levels. However, the mechanism by which these mutants reduce LDL reuptake is not fully understood. Here, we have used molecular dynamics simulations, MM/PBSA (Molecular Mechanics/Poisson–Boltzmann Surface Area) binding affinity calculations, and residue interaction networks, to investigate the protein–protein interaction (PPI) disruptive effects of two of PCSK9's gain-of-function mutations, Ser127Arg and Asp374Tyr on the PCSK9 and LDL receptor complex. In addition to these PPI disruptive mutants, a third, non-interface mutation (Arg496Trp) is included as a positive control. Our results indicate that Ser127Arg and Asp374Tyr confer significantly improved binding affinity, as well as different binding modes, when compared to the wild-type. These PPI disruptive mutations lie between the EGF(A) (epidermal growth factor precursor homology domain A) of the LDL receptor and the catalytic domain of PCSK9 (Asp374Tyr) and between the prodomain of PCSK9 and the β-propeller of the LDL receptor (Ser127Arg). The interactions involved in these two interfaces result in an LDL receptor that is sterically inhibited from entering its closed conformation. This could potentially implicate the prodomain as a target for small molecule inhibitors.

59 BASIC BIOLOGICAL SCIENCES↗

Field Testing of Compartmentalization Methods for Multifamily Construction - Washington DC

BSC TO5 Task 2.1 Field Testing of Compartmentalization Methods for Multifamily Construction - Capitol Heights, MD 20743 A building comprising five vertical townhome units was built in the Washington, D.C., area; the townhomes were three-story slab-on-grade units (1700-2000 ft2) with a rear-facing "tuck under" garage. The three-story townhome design results in 3 ACH50 being equivalent to a stringent surface-area based target (0.16-0.17 CFM50/ft2 building enclosure). The party walls between units were area separation walls, with a 2-hour fire resistance rating (Underwriters Laboratories U347 assembly; equivalent to U373 and U336). This assembly has a 1-in. vertical air cavity on each side of a 2-in. vertical gypsum panel in the middle of the assembly, resulting in an airflow network that is connected over multiple floors (despite nominal draft stopping), and has potential connections to exterior conditions. The test townhomes were built with several experimental airtightness details, including taping of exterior sheathing as an air barrier closure detail (in particular, at area separation walls). Various measures were applied to the units for this experiment, including a "control" conventional construction unit and some units with "improved" detailing (without taped sheathing).

air leakage↗

Machine Learning Downscaling of SoilMERGE in the United States Southern Great Plains

SoilMERGE (SMERGE) is a root-zone soil moisture (RZSM) product that covers the entire continental United States and spans 1978 to 2019. Machine learning techniques, Random Forest (RF), eXtreme Gradient Boosting (XGBoost), and Gradient Boost (GBoost) downscaled SMERGE to spatial resolutions straddling the field scale domain (100 to 3000 m). Study area was northern Oklahoma and southern Kansas. The coarse resolution of SMERGE (0.125 degree) limits this product’s utility. To validate downscaled results in situ data from four sources were used that included: United States Department of Energy Atmospheric Radiation Measurement (ARM) observatory, United States Climate Reference Network (USCRN), Soil Climate Analysis Network (SCAN), and Soil moisture Sensing Controller and oPtimal Estimator (SoilSCAPE). In addition, RZSM retrievals from NASA’s Airborne Microwave Observatory of Subcanopy and Surface (AirMOSS) campaign provided a nearly spatially continuous comparison. Three periods were examined: era 1 (2016 to 2019), era 2 (2012 to 2015), and era 3 (2003 to 2007). During eras 1 and 2, RF outperformed XGBoost and GBoost, whereas during era 3 no model dominated. Performance was better during eras 1 and 2 as opposed to the pre-L band era 3. Improvements across all eras, regions, and models realized from downscaling included an increase in correlation from 0.03 to 0.42 and a decrease in ub RMSE from -0.0005 to -0.0118 m 3 /m 3 . This study demonstrates the feasibility of SMERGE downscaling opening the prospect for the development of a long-term RZSM dataset at a more desirable field-scale resolution with the potential to support diverse hydrometeorological and agricultural applications.

54 ENVIRONMENTAL SCIENCES↗

Role of underlying surface, rainstorm and antecedent wetness condition on flood responses in small and medium sized watersheds in the Yangtze River Delta region, China

Floods are becoming more frequent and are hard to control due to the shortage of water conservancy projects in small and medium sized basins, especially in developing regions. Understanding the hydrologic responses and estimated flood characteristics to storm events can help to predict flood disasters and form better effective mitigation and adaptation strategies. Here, using observations of several representative watersheds and Artificial Neural Networks (ANN) and Principal Component Regression (PCR) models, we conducted data-driven analyses to examine the flood responding characteristics. We quantified the relative contributions of the influencing factors to the variation of each flood characteristic. Statistical analysis of the observations shows that the drainage area plays a key role in determining the distribution of lag time and peak discharge. Rainstorm variability has direct influence on floods, and typhoon-induced rainstorms with high total rainfall and rainfall intensity generate higher lag time, flood peak, unit discharge and runoff depth, but lower runoff coefficient. The ANN and PCR models accurately predicted the variations of flood features using the driving factors including physical geographical characteristics, rainstorm features, and antecedent condition. Physical geographic characteristics are key influential factors of lag time, flood peak and runoff coefficient, while the rainstorm features control the magnitude of unit discharge and runoff depth. These results indicate that floods are mainly affected by rainstorm features and physical geographic characteristics in the Yangtze River delta, and it might become more damaging with the increasing rainfall extremes and sprawling impervious surfaces in a changing environment.

54 ENVIRONMENTAL SCIENCES↗

Stormwater Storage and Retention Within an Urban Prairie Wetland Complex

Climate change is expected to increase the frequency and severity of flooding in the Great Lakes region. In many cities, flood-control infrastructure is insufficient to protect against future climate conditions. Consequently, there is increasing focus on stormwater storage provided by urban greenspace, such as wetlands and prairies, but the ecohydrological behavior of these ecosystems is not well understood when they are embedded within cities. To improve understanding of hydrological connectivity between urban areas and natural greenspaces, we deployed a sensor network in Gensburg Markham Prairie (GMP), a large intact prairie-wetland complex in south suburban Chicago. We used the resulting high-frequency time-series data to assess surface-subsurface hydrologic dynamics between upland and low-lying wetland areas, interactions between the prairie and surrounding environment, and stormwater storage provided by the prairie. Rapid infiltration within the prairie during and after storm events provides subsurface flow that stores considerable water, flattens storm hydrographs, and increases the wetland hydroperiod. Much of the stormwater input to GMP derives from the surrounding cityscape. Consequently, storage within the prairie-wetland system reduces and slows stormwater discharge to downstream urban communities. For a typical 5-year 24-hr storm with 10.9 cm of rain, GMP stores 77,100 m 3 , 64% greater than the estimated direct rainfall volume onto the prairie, yielding 30,000 m 3 of offsite stormwater storage. This improved understanding of ecohydrological dynamics in urban prairies and wetlands informs the design and implementation of green infrastructure to meet growing needs for stormwater management.

Rivera, Vivien Anne [Northwestern University, Evan↗

A Remote Development Process and Platform for Power Electronic Systems

Like many areas in research and development, power electronic and distributed energy resource research and development slowed during the COVID pandemic. While the presence of the virus has reduced and workers are returning to shared offices, uncertainty of potential future challenges are still present. This work proposes a development and testing network that provides researchers the ability to operate remotely and coordinate control and debug activities for power electronic systems. This development and testing network has been demonstrated in both controller hardware-in-the-loop (C-HIL) and hardware testing.

Starke, Michael↗

2019 Results for Avian Monitoring at the Technical Area 36 Minie Site, Technical Area 39 Point 6, and Technical Area 16 Burn Ground at the Los Alamos National Laboratory

Los Alamos National Laboratory biologists in the Environmental Compliance and Protection Division at Los Alamos National Laboratory (LANL) initiated a multi-year program in 2013 to monitor avifauna (birds) at two open detonation sites and one open burn site on LANL property. Monitoring results from these efforts were compared among years to monitor trends. The objectives of this study were to 1) determine whether LANL operations impact bird species richness, diversity, or abundance 2) evaluate trends in species abundance by feeding guild, and 3) examine occupancy and nest success of secondary-cavity nesting birds using nestboxes. LANL biologists completed the seventh year of this effort in 2019. Three bird point count surveys were completed at each of the treatment sites at the Technical Area (TA) 36 Minie site, the TA-39 point 6, and the TA-16 burn ground between May and July 2019. A total of 853 birds representing 53 species were recorded at the three treatment sites and compared to their associated controls. Occupancy and nest success data from nestboxes at treatment sites were compared with the overall avian nestbox monitoring network. In 2019 the species richness and diversity at the treatment sites were not statistically different from their associated controls. Rarefaction and extrapolation plots for all years through 2018 suggest that over time the species diversity was statistically different between treatments and controls, although the diversity was higher at the treatment sites than the control sites. Avian abundance showed more variability but treatment and controls were trending together year to year. The mean number of granivores, insectivores, and omnivores varies from year to year, but there is not a significant trend at any of the treatment sites. The dominant feeding guild at the treatment sites continues to be insectivores. The overall results from 2019 continue to indicate that operations at the three treatment sites are not negatively affecting bird populations. This long-term monitoring will continue to monitor for any changes over time.

54 ENVIRONMENTAL SCIENCES↗

Unleashing the Power of Wide-Area Data Analytics for Enhanced Grid Visibility

We report that the operation of modern electric transmission systems relies increasingly on the use of advanced sensing and synchronized-measurement technologies. These technologies collect and collate a wide variety of data from disperse locations to monitor the health of network, obtain fast and accurate diagnosis of systemic changes, and detect signs of anomalies and instabilities at an early stage. In view of the far-reaching blackout risk from potential damages to critical transmission grid assets (due to severe disturbances, physical attacks, and extreme weather events), stealthy activities that compromise the operation of wide-area sensing, communication, and control systems could cripple the entire cyber-physical smart-grid infrastructure. To this end, achieving robust event identification, ensuring bulk system observability, and developing actionable intelligence (by fostering data-driven decision making under imminent threat of complex, multifaceted attacks and disruptions) remain key challenges for sustaining a resilient power grid operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Non-Destructive Assay Systems and Special Instrumentation Requirements for Spent Nuclear Fuel Recycling Facilities

The safe and efficient operation of the next generation of Spent Nuclear Fuel (SNF) recycling / reprocessing facilities is dependent upon the availability of high performance real time Non- Destructive Assay (NDA) systems at key in-line points. A diverse variety of such special instrument systems have been developed and commissioned at reprocessing plants worldwide over the past fifty years.. The measurement purpose, technique and plant performance for selected key systems have been reviewed. Obsolescence issues and areas for development are identified in the context of the measurements needs of future recycling facilities and their associated waste treatment plants. Areas of concern include (i) Materials Accountancy and Safeguards, (ii) Head End process control and feed envelope verification, (iii) Real-time monitoring at the Product Finishing Stages, (iv) Criticality safety and (v) Radioactive waste characterization. Common characteristics of the traditional NDA systems in historical recycling facilities are (i) In-house development of bespoke instruments resulting in equipment that if often unique to a given facility and generally not commercially available, (ii) Use of 'novel' techniques - not widely deployed in other applications, (iii) Design features that are tailored to the specific plant requirements of the facility operator, (iv) Systems and software implementation that was not always carried out to modern industry standards and (v) A tendency to be overly complex - refined by on-plant operational usage and experience. Although these systems were 'validated in use' and are generally fit for purpose, there are a number of potential problems in transferring technology that was developed ten or more years ago to the new build SNF recycling facilities of the future. These issues include (i) Obsolescence of components - particularly with respect to computer hardware and data acquisition electronics, (ii) Availability of Intellectual Property and design drawings and documentation (iii) Lack of compatibility with modern computers, software, data transfer networks, digital protocols and electrical code standards, (iv) Non-compliance with current and future mandatory standards and regulations for nuclear facilities (v) Design focused on measurement and control points that may be specific to the facility process (vi) Lack of utilization of recent technological advances where better performing, less complex and more cost-effective options are now available. Key radiometric measurement drivers and control points for future recycling facilities have been determined and a review of the adequacy of existing instrumentation has been performed. Areas where recent technology improvements may be more effectively deployed and future technology development may be appropriate are identified. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long-term nitrogen deposition enhances microbial capacities in soil carbon stabilization but reduces network complexity

Background: Anthropogenic activities have increased the inputs of atmospheric reactive nitrogen (N) into terrestrial ecosystems, affecting soil carbon stability and microbial communities. Previous studies have primarily examined the effects of nitrogen deposition on microbial taxonomy, enzymatic activities, and functional processes. Here, we examined various functional traits of soil microbial communities and how these traits are interrelated in a Mediterranean type grassland administrated with 14 years of 7 g m –2 year –1 of N amendment, based on estimated atmospheric N deposition in areas within California, USA, by the end of the twenty-first century. Results: Soil microbial communities were significantly altered by N deposition. Consistent with higher aboveground plant biomass and litter, fast-growing bacteria, assessed by abundance-weighted average rRNA operon copy number, were favored in N deposited soils. The relative abundances of genes associated with labile carbon (C) degradation (e.g., amyA and cda) were also increased. In contrast, the relative abundances of functional genes associated with the degradation of more recalcitrant C (e.g., mannanase and chitinase) were either unchanged or decreased. Compared with the ambient control, N deposition significantly reduced network complexity, such as average degree and connectedness. The network for N deposited samples contained only genes associated with C degradation, suggesting that C degradation genes became more intensely connected under N deposition. Conclusions: We propose a conceptual model to summarize the mechanisms of how changes in above- and belowground ecosystems by long-term N deposition collectively lead to more soil C accumulation.

59 BASIC BIOLOGICAL SCIENCES↗