Search NASA⌕ Search

SEARCH · Search NASA

Results for “counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Risk of Mortality in Family Members of Men Seeking Fertility Assessment

Objective: To assess mortality in family members of men seeking fertility assessment. Subfertility serves as a biomarker for overall somatic health, and poor semen quality is associated with increased risk of hospitalization and mortality from chronic conditions. However, it is unclear if these risks extend to family members of men with low sperm count. Design: Retrospective cohort study. Subjects: Family members, up to third-degree relatives, of men in the Subfertility, Health and Assisted Reproduction and the Environment cohort who underwent a semen analysis as part of a fertility assessment 1996–2017. Relatives of men with a recorded total sperm count who lived in Utah for ≥1 year 1904–2017 were included in the analysis (N = 22,280 families). Exposure: Individuals were classified by family membership. Families were classified as relatives of azoospermic (0M), oligozoospermic (<39M), or normozoospermic (≥39M) men. The average total sperm count of the proband (male relative) with fertility assessment was also included as a continuous exposure measure. Main Outcome Measures: The main outcomes were all-cause and cause-specific mortality risk by sex, age, and degree of relation: first-, second-, and third-degree. Cox proportional hazard models were used to test the association between fertility classification and mortality, controlling for sex, race/ethnicity, and birth year. Results: A total of 666,437 relatives of men with fertility assessment (N deaths = 183,974) were included in the analysis. Relative to normozoospermia families, all-cause mortality risk increased in oligozoospermia families (hazard ratio [HR] oligozoospermia , 1.03; 95% confidence interval [CI], 1.01–1.05). Close relatives, first- (HR oligozoospermia , 1.17; 95% CI, 1.07–1.28) and second-degree relatives (HR azoospermia , 1.11; 95% CI, 1.04–1.20; HR oligozoospermia , 1.05; 95% CI,1.01–1.09), of azoospermic and oligozoospermic men had the highest all-cause and cause-specific mortality risk, including death attributed to cardiovascular disease or congenital birth conditions. Conclusion: Our results suggest that familial all-cause and cause-specific mortality risk differ by fertility phenotype. Families of azoospermic and oligozoospermic men showed significantly increased risk, particularly for close relatives. This study provides further evidence that shared genetic and/or environmental factors could influence both fertility and somatic health.

Male fertility↗

Conceptual design study of neutron detectors for safeguards measurement of an irradiated pebble

Nuclear material control and accounting (MC&A) of pebble-bed reactors (PBRs) is challenging because a PBR utilizes hundreds of thousands of identical, unmarked pebbles that are continuously recirculated through the core. To develop tools that enable the implementation of international safeguards, especially in the context of MC&A of spent pebbles, we designed and simulated three neutron detection concepts to determine fissile content in individual pebbles: a differential die-away (DDA) detector, a californium interrogation prompt neutron (CIPN) detector, and a passive neutron albedo reactivity (PNAR) detector using Monte Carlo calculations. Burnup calculations were performed on the spent pebbles from the PBMR-400 classic PBR. The varying neutron and gamma source terms, and isotopic compositions in the spent pebbles calculated at various burnup levels were used in the neutron detector models. DDA was found to be sensitive to the number of passes a pebble has had through the core and to the fissile content contained in a spent pebble. Optimization in the DDA design further increased the neutron count rates and thus reduced counting uncertainty. Meanwhile, passive neutron counting using the same detector body could distinguish pebbles with different numbers of passes, but its response was dominated by neutron-emitting actinides and was not sensitive to fissile content. On the other hand, the PNAR technique was not viable for a single pebble but performed reasonably for a 27-pebble array, which suggested potential use for verification measurements of containers filled with 27 or more spent pebbles.

CIPN↗

Deployment of a double scatter system for directional detection of background neutron radiation

The detection of special nuclear materials (SNM) requires the understanding of nuclear signatures that allow the discrimination against background. In particular, understanding neutron background characteristics such as count rates and energies and their correlations with environmental conditions and surroundings of measurement locations is important in enhancing SNM detection capabilities. The Mobile Imager of Neutrons for Emergency Responders (MINER) was deployed for 8 weeks in downtown San Francisco (CA) to study such neutron background characteristics in an urban environment. Of specific interest was the investigation of the impact of surrounding buildings on the neutron background count rates and to answer the question whether buildings act as absorber of neutrons or as sources via the so-called ship effect. MINER consists of 16 liquid scintillator detector elements and can be operated as a neutron spectrometer, as a neutron imager, or simply as a counter of fast neutrons. As expected, the neutron background rate was found to be inversely proportional to the atmospheric pressure. In the energy range where MINER is most sensitive, approximately 1–10 MeV, it was found that the shape of the detected background spectrum is similar to that of a detected fission spectrum, indicating the limited discrimination power of the neutron energy. The similarities between the detected background neutron spectrum and fission sources makes it difficult to discriminate SNM from background based solely on the energies observed. The images produced using maximum likelihood expectation maximization revealed that neutrons preferentially are coming from areas in the environment that have open sky, indicating that the surrounding buildings act as absorbers of neutrons rather than sources as expected by the ship effect. Here, the inherent properties of a neutron scatter camera limit the achievable image quality and the effective deployment to systematically map neutron background signatures due to the low count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

The gallium anomaly

In order to test the end-to-end operations of gallium solar neutrino experiments, intense electron-capture sources were fabricated to measure the responses of the radiochemical SAGE and GALLEX/GNO detectors to known fluxes of low-energy neutrinos. Such tests were viewed at the time as a cross-check, given the many tests of 71 Ge recovery and counting that had been routinely performed, with excellent results. However, the four 51 Cr and 37 Ar source experiments yielded rates below expectations, a result commonly known as the Ga anomaly. As the intensity of the electron-capture sources can be measured to high precision, the neutrino lines they produce are fixed by known atomic and nuclear rates, and the neutrino absorption cross section on 71 Ga is tightly constrained by the lifetime of 71 Ge, no simple explanation for the anomaly has been found. To check these calibration experiments, a dedicated experiment BEST was performed, utilizing a neutrino source of unprecedented intensity and a detector optimized to increase statistics while providing some information on counting rate as a function of distance from the source. The results BEST obtained are consistent with the earlier solar neutrino calibration experiments, and when combined with those measurements, yield a Ga anomaly with a significance of approximately 4𝜎, under conservative assumptions. But BEST found no evidence of distance dependence and thus no explicit indication of new physics. In this review we describe the extensive campaigns carried out by SAGE, GALLEX/GNO, and BEST to demonstrate the reliability and precision of their experimental procedures, including 71 Ge recovery, counting, and analysis. We also describe efforts to define uncertainties in the neutrino capture cross section, which now include estimates of effects at the ≲ 0.5% level such as radiative corrections and weak magnetism. With the results from BEST, an anomaly remains even if one retains only the transition to the 71 Ge ground state, whose strength is fixed by the known lifetime of 71 Ge. We then consider the new-physics solution most commonly suggested to resolve the Ga anomaly, oscillations into a sterile fourth neutrino, 𝜈 𝑒 → 𝜈 𝑠 . We find such a solution generates substantial tension with several null experiments, owing to the large mixing angle required. While this does not exclude such solutions – the sterile sector might include multiple neutrinos as well as new interactions – it shows the need for more experimental constraints, if we are to make progress in resolving the Ga and other low-energy neutrino anomalies. We conclude by consider the role future low-energy electron-capture sources could play in this effort.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Variability and associated uncertainty in image analysis for soiling characterization in solar energy systems

The accumulation of soiling on photovoltaic modules and on the mirrors of concentrating solar power systems causes non-negligible energy losses with economic consequences. These challenges can be mitigated, or even prevented, through appropriate actions if the magnitude of soiling is known. Particle counting analysis is a common procedure to characterize soiling, as it can be easily performed on micrographs of glass coupons or solar devices that have been exposed to the environment. Particle counting does not, however, yield invariant results across institutions. The particle size distribution analysis is affected by the operator of the image analysis software and the methodology utilized. The results of a round-robin study are presented in this work to explore and elucidate the uncertainty related to particle counting and its effect on the characterization of the soiling of glass surfaces used in solar energy conversion systems. An international group of soiling experts analyzed the same 8 micrographs using the same open-source ImageJ software package. The variation in the particle analyses results were investigated to identify specimen characteristics with the lowest coefficient of variation (CV) and the least uncertainty among the various operators. The mean particle diameter showed the lowest CV among the investigated characteristics, whereas the number of particles exhibited the largest CV. Additional parameters, such as the fractional area coverage by particles and parameters related to the distribution's shape yielded intermediate CV values. These results can provide insights on the magnitude inter-lab variability and uncertainty for optical and microscope-based soiling monitoring and characterization.

14 SOLAR ENERGY↗

Simplified Method for the In Situ Collection and Laboratory Analysis of Cosmogenic Tracers (Sulfur-35 and Sodium-22) to Determine Residence Time Distributions and Water Ages

The use of cosmogenically produced sulfur-35 (T 1/2 = 87 days) and sodium-22 (T 1/2 = 2.6 years) as intrinsic tracers can provide valuable information on catchment hydrology, flow paths, and subsurface storage. A new and straightforward method was created to determine the activities of both 35 S and 22 Na in various water sources by pumping large volumes (up to 1000 L) of water through cation- and anion-exchange resin columns in the field to collect sodium and sulfate ions and simple chemistry in the lab. Samples are counted for 35 S using liquid scintillation counting (LSC) and for 22 Na via γ spectroscopy. Our novel in situ method provides faster sample throughput as well as better counting statistics and lower detection limits. Both methods were successfully applied at the Southern Sierra Critical Zone Observatory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing Historical Variability of South Asian Monsoon Lows and Depressions With an Optimized Tracking Algorithm

Abstract Cyclonic low‐pressure systems (LPS) produce abundant rainfall in South Asia, where they are traditionally categorized as monsoon lows, monsoon depressions, and more intense cyclonic storms. The India Meteorological Department (IMD) has tracked monsoon depressions for over a century, finding a large decline in their number in recent decades, but their methods have changed over time and do not include monsoon lows. This study presents a fast, objective algorithm for identifying monsoon LPS and uses it to assess interannual variability and trends in reanalyses. Variables and thresholds used in the algorithm are selected to best match a subjectively analyzed LPS data set while minimizing disagreement between four reanalyses in a training period. The stream function of 850 hPa horizontal wind is found to be optimal in this sense; it is less noisy than vorticity and represents the complete nondivergent wind, even when flow is not geostrophic. Using this algorithm, LPS statistics are computed for five reanalyses, and none show a detectable trend in monsoon depression counts since 1979. Both the Japanese 55‐year Reanalysis (JRA‐55) and the IMD data set show a step‐like reduction in depression counts when they began using geostationary satellite data, in 1979 and 1982, respectively; the 1958–2018 linear trend in JRA‐55, however, is smaller than in the IMD data set, and its error bar includes 0. There are more LPS in seasons with above‐average monsoon rainfall and in La Niña years, but few other large‐scale modes of interannual variability are found to modulate LPS counts, lifetimes, or track length consistently across reanalyses.

54 ENVIRONMENTAL SCIENCES↗

Estimation of Possible Primary Biological Particle Emissions and Rupture Events at the Southern Great Plains ARM Site

We use 10 years of data from the Department of Energy (DoE) Atmospheric Radiation Measurements (ARM) United States Southern Great Plains (SGP) site with nearby regional pollen and fungal spore measurements to indirectly estimate the seasonal influence of these two primary biological aerosol particles (PBAP). We estimate possible primary emissions of larger PBAP and PBAP rupture events, which form submicron organic aerosol during precipitation or high relative humidity. High pollen counts at two urban stations near SGP occur during late winter/early spring (day of year (DOY) 50–120) and late summer (DOY 240–310). Around 4–19 days per year show possible pollen events (PPE) when near-surface lidar observations of daily linear particle depolarization ratio >0.1 are coincident with high organic aerosol fraction. For PPE days with rainfall, aerosol size distribution observations show enhanced submicron particle concentrations consistent with pollen rupture events. For fungal spores, high fungal spore counts occur during late spring/early summer (DOY 110–195) and late summer/autumn (DOY 220–340). Based on size distribution observations, up to 7% of days have possible fungal spore rupture events (PFE) with higher aerosol number count specifically over the range expected for fungal spore fragment mobility diameter (20–50 nm). These short-lived PFE correlate with rainfall or occur after prolonged exposure to rainfall (e.g., >10 h). While the SGP site lacks direct measurements of bioaerosol and large particle sizes, this analysis suggests that PBAP primary emissions and rupture events could occur about 32 days per year, representing an important component of the aerosol budget during seasonal emissions.

54 ENVIRONMENTAL SCIENCES↗

Ultimate precision limit of noise sensing and dark matter search

Abstract The nature of dark matter is unknown and calls for a systematical search. For axion dark matter, such a search relies on finding feeble random noise arising from the weak coupling between dark matter and microwave haloscopes. We model such process as a quantum channel and derive the fundamental precision limit of noise sensing. An entanglement-assisted strategy based on two-mode squeezed vacuum is thereby demonstrated optimal, while the optimality of a single-mode squeezed vacuum is found limited to the lossless case. We propose a “nulling” measurement (squeezing and photon counting) to achieve the optimal performances. In terms of the scan rate, even with 20-decibel of strength, single-mode squeezing still underperforms the vacuum limit which is achieved by photon counting on vacuum input; while the two-mode squeezed vacuum provides large and close-to-optimum advantage over the vacuum limit, thus more exotic quantum resources are no longer required. Our results highlight the necessity of entanglement assistance and microwave photon counting in dark matter search.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection and quantification of γ-H2AX using a dissociation enhanced lanthanide fluorescence immunoassay

Phosphorylation of the histone protein H2AX to form γ-H2AX foci directly represents DNA double-strand break formation. Traditional γ-H2AX detection involves counting individual foci within individual nuclei. The novelty of this work is the application of a time-resolved fluorescence assay using dissociation-enhanced lanthanide fluorescence immunoassay for quantitative measurements of γ-H2AX. For comparison, standard fluorescence detection was employed and analyzed either by bulk fluorescent measurements or by direct foci counting using BioTek Spot Count algorithm and Gen 5 software. Etoposide induced DNA damage in A549 carcinoma cells was compared across all test platforms. Time resolved fluorescence detection of europium as a chelated complex enabled quantitative measurement of γ-H2AX foci with nanomolar resolution. Comparative bulk fluorescent signals achieved only micromolar sensitivity. Lanthanide based immunodetection of γ-H2AX offers superior detection and a user-friendly workflow. These approaches have the potential to improve screening of compounds that either enhance DNA damage or protect against its deleterious effects.

59 BASIC BIOLOGICAL SCIENCES↗

Alternatives to NIST Cf-252 Iirradiations for Transfer Calibration of S-32 Neutron Monitors

Gas-flow proportional counting systems are used by the Radiation Metrology Laboratory (RML) at Sandia National Laboratories for reactor fluence monitoring with the 32 S(n,p) 32 P reaction. Calibration of these systems has traditionally been accomplished by fluence-transfer irradiations at the NIST 252 Cf facility. Such calibrations have become increasingly difficult as the NIST 252 Cf source decayed to unusable levels. To minimize the risk to the testing programs from an inability to properly calibrate these systems, the RML has developed two alternative calibration techniques: 1) development and implementation of certified 32 P sources for activity calibrations and subsequent calculation of neutron fluence, and 2) direct counting of non-certified reactor-irradiated sulfur pellets by liquid scintillation counting to determine 32 P activity for the subsequent calibration of gas-flow proportional counters. Preliminary comparisons show that the several calibration methods are capable of overall uncertainties within about 5 percent.

Vehar, David W.↗

Sensitive neutron transverse polarization analysis using a 3 He spin filter

Here we report an experimental implementation for neutron transverse polarization analysis that is capable of detecting a small angular change ($\ll$10 –3 rad) in neutron spin orientation. This approach is demonstrated for monochromatic beams, and we show that it could be extended to polychromatic neutron beams. Our approach employs a 3 He spin filter inside a solenoid with an analyzing direction perpendicular to the incident neutron polarization direction. The method was tested with polarized neutron beams and a spin rotator placed inside a μ -metal shield just upstream of the analyzer. No cryogenic superconducting shields or additional neutron spin manipulations are needed. With a counting detector, we experimentally show that the angular resolution δ θ = 1 / ( P n A N ) rad is only determined by the counting statistics for the total counts N and the product of the neutron polarization P n and the analyzing power A . With a high-flux neutron beam, 10 –6 rad angular sensitivity is feasible within a day. This simple, classical-quantum-limited transverse polarization analysis scheme may reduce the overall complexity of experimental implementation for applications requiring sensitive neutron polarimetry and improve the precision in fundamental science studies and polarized neutron imaging.

47 OTHER INSTRUMENTATION↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗

Scintillator-based Timepix3 detector for neutron spin-echo techniques using intensity modulation

A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6 LiF:ZnS(Ag) and 6 LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE). The methodology for conducting event-mode analysis is described, including the optimization of clustering parameters for both scintillators. The detector with both scintillators was characterized with respect to detection efficiency, spatial resolution, count rate, uniformity, and γ-sensitivity. The 6 LiF:ZnS(Ag) scintillator-based detector achieved a spatial resolution of 200 μm and a count rate capability of 1.1 × 10 5 cps, while the 6 LiI:Eu scintillator-based detector demonstrated a spatial resolution of 250 μm and a count rate capability exceeding 2.9 × 10 5 cps. Furthermore, high-frequency intensity modulations in both spatial and temporal domains were successfully observed, confirming the suitability of this detector for SEMSANS and MIEZE techniques, respectively.

47 OTHER INSTRUMENTATION↗

Effect of likelihood misspecification in Gaussian process-driven autonomous experimentation

In recent years, several groups have designed Autonomous Experiment (AE) models with the aim of using them as an alternative method for neutron scattering scanning. In an AE, Gaussian processes (GPs) are most frequently used due to their interpretability, their non-parametric nature, their universal approximation, and their closed-form predictive distribution. GPs have two key components, namely, the model for the likelihood of a neutron count knowing the underlying dynamic structure factor and the acquisition function. In this paper, we investigate the impact, on the quality of an AE, of the likelihood and acquisition function choices, in energy scans and (Q, ω) ones, with respect to the signal-over-noise ratio. While we hypothesized that the quality of GP predictions would decrease when the normal to Poisson likelihood approximation breaks down at low count rates, we found that the use of the correct Poisson likelihood does not improve the quality of the data collected, as well as yields very poor results in (Q, ω) scans at low count rates. In fact, the best results are obtained with a combination of normal likelihood, including the observation noise, and the change in variance acquisition function. In addition, we find that the performance, or quality of the predictive distribution, is a misleading measure of efficiency, that is, of the quality of the data collected.

Perryman, David Elliott [Inst. Laue-Langevin (ILL)↗

Cryosectioning-enhanced super-resolution microscopy for single-protein imaging across cells and tissues

DNA-points accumulation for imaging in nanoscale topography (DNA-PAINT) enables nanoscale imaging with virtually unlimited multiplexing and molecular counting. Here, we address challenges, such as variable imaging performance and target accessibility, that can limit its broader applicability. Specifically, we enhance its capacity for robust single-protein imaging and molecular counting by optimizing the integration of total internal reflection fluorescence microscopy with physical sectioning, in particular, Tokuyasu cryosectioning. Our method, tomographic and kinetically enhanced DNA-PAINT (tkPAINT), achieves 3 nm localization precision across diverse samples, enhanced imager binding, and improved cellular integrity. tkPAINT can facilitate molecular counting with DNA-PAINT inside the nucleus, as demonstrated through its quantification of the in situ abundance of RNA Polymerase II in both HeLa cells as well as mouse tissues. Anticipating that tkPAINT could become a versatile tool for the exploration of biomolecular organization and interactions across cells and tissues, we also demonstrate its capacity to support multiplexing, multimodal targeting of proteins and nucleic acids, and three-dimensional (3D) imaging.

Science & Technology - Other Topics↗

Optical noise in a free-space quantum communications link from natural and nuclear disturbed environments*

Satellite communications at radio frequencies can experience a ‘blackout’ period following the atmospheric detonation of a nuclear weapon. The wavelengths used for free-space quantum communications will not incur the same ‘blackout’ effects from a nuclear detonation, but the optical systems will suffer from a phenomenon called redout. Redout occurs in an optical detector when ambient light scatters into the optical receiver, causing elevated background photon counts in the detector such that background noise overwhelms the signal. In this work, the duration of the redout effect is quantified from a nuclear disturbed environment on a ground-to-space quantum optical link. In addition, we comment on various techniques for reducing ambient and nuclear disturbed background counts in a quantum free-space optical link. For low-altitude nuclear detonations (i.e., under 50 km), the maximum interference time will be less than 1 min. Implementing a telescope, timing gate, and wavelength filter to the detector can reduce the background counts in the detector significantly. Aerosol levels and ground albedo are major contributors to background noise in a ground-to-satellite quantum channel, and ground station location should factor in both variables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗