Search NASA⌕ Search

SEARCH · Search NASA

Results for “crossover”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Evidence for central venous pressure resetting during initial exposure to microgravity

We measured central venous pressure (CVP); plasma volume (PV); urine volume rate (UVR); renal excretion of sodium (UNa); and renal clearances of creatinine, sodium, and osmolality before and after acute volume infusion to test the hypothesis that exposure to microgravity causes resetting of the CVP operating point. Six rhesus monkeys underwent two experimental conditions in a crossover counterbalance design: 1) continuous exposure to 10 degrees head-down tilt (HDT) and 2) a control, defined as 16 h/day of 80 degrees head-up tilt and 8 h prone. After 48 h of exposure to either test condition, a 120-min course of continuous infusion of isotonic saline (0.4 ml. kg(-1). min(-1) iv) was administered. Baseline CVP was lower (P = 0.011) in HDT (2.3 +/- 0.3 mmHg) compared with the control (4.5 +/- 1.4 mmHg) condition. After 2 h of saline infusion, CVP was elevated (P = 0.002) to a similar magnitude (P = 0.485) in HDT (DeltaCVP = 2.7 +/- 0.8 mmHg) and control (DeltaCVP = 2.3 +/- 0.8 mmHg) conditions and returned to preinfusion levels 18 h postinfusion in both treatments. PV followed the same pattern as CVP. The response relationships between CVP and UVR and between CVP and UNa shifted to the left with HDT. The restoration of CVP and PV to lower preinfusion levels after volume loading in HDT compared with control supports the notion that lower CVP during HDT may reflect a new operating point about which vascular volume is regulated. These results may explain the ineffective fluid intake procedures currently employed to treat patients and astronauts.

NASA Discipline Cardiopulmonary↗

Novel method to assess gastric emptying in humans: the Pellet Gastric Emptying Test

To further validate the Pellet Gastric Emptying Test (PGET) as a marker of gastric emptying, a randomized, four-way crossover study was conducted with 12 healthy subjects. The study consisted of oral co-administration of enteric coated caffeine (CAFF) and acetaminophen (APAP) pellets in four treatment phases: Same Size (100 kcal), Fasted, Small Liquid Meal (100 kcal), and Standard Meal (847 kcal). The time of first appearance of measurable drug marker in plasma, t(initial), was taken as the emptying time for the markers. Co-administration of same size enteric coated pellets of CAFF and APAP (0.7 mm in diameter) revealed no statistically significant differences in t(initial) values indicating that emptying was dependent only on size and not on chemical make-up of the pellets. Co-administration of different size pellets indicated that the smaller 0.7-mm diameter (CAFF) pellets were emptied and absorbed significantly earlier than the larger 3.6-mm diameter (APAP) pellets with both the Small Liquid Meal (by 35 min) and the Standard Meal (by 33 min) (P<0.05). The differences in emptying of the pellets were not significant in the Fasted Phase. The results suggest that the pellet gastric emptying test could prove useful in monitoring changes in transit times in the fasted and fed states and their impact on drug absorption.

NASA Discipline Regulatory Physiology↗

Computational Ion Optics Design Evaluations

Ion optics computational models are invaluable tools in the design of ion optics systems. In this study a new computational model developed by an outside vendor for use at the NASA Glenn Research Center (GRC) is presented. This computational model is a gun code that has been modified to model the plasma sheaths both upstream and downstream of the ion optics. The model handles multiple species (e.g. singly and doubly-charged ions) and includes a charge-exchange model to support erosion estimations. The model uses commercially developed solid design and meshing software to allow high flexibility in ion optics geometric configurations. The results from this computational model are applied to the NEXT project to investigate the effects of crossover impingement erosion seen during the 2000-hour wear test.

Malone, Shane P.↗

Growth Modes and Energetics of 101 Face Lysozyme Crystal Growth

From analyses of lysozyme 101 face growth rate data using a 2D nucleation model for layer-by-layer growth, we find the effective barrier for crystal growth to be gamma = 1.0 +/- 0.2 x 10(exp -13) erg/molecule. The magnitude of the effective barrier is 2.4 +/- 0.5 k(sub beta)T, at 22 C. We also find that beyond a critical solution supersaturation, sigma(sub c), crystal growth rates are more accurately described by a kinetic roughening hypothesis. Beyond sigma(sub c), crystals grow by the continuous addition of molecules anywhere on the crystal surface rather than layer-by-layer. The magnitude of the critical supersaturation (sigma(sub c), = 1.7 +/- 0.2) for a crossover from a layer-by-layer to continuous growth is found to be statistically independent of the solution conditions that vary with buffer pH, temperature or precipitant concentration. Using the experimentally determined values for gamma and sigma(sub c), we find the crystal growth unit to be comprised of 7 +/- 3 molecules. The energy barrier, E(sub c), for the continuous addition of the growth Units is 6.2 +/- 0.3 x 10(exp -13) erg/molecule or 15 +/1 1 k(sub beta)T at 22C.

Gorti, Sridhar↗

Pyruvate ingestion for 7 days does not improve aerobic performance in well-trained individuals

The purposes of the present studies were to test the hypotheses that lower dosages of oral pyruvate ingestion would increase blood pyruvate concentration and that the ingestion of a commonly recommended dosage of pyruvate (7 g) for 7 days would enhance performance during intense aerobic exercise in well-trained individuals. Nine recreationally active subjects (8 women, 1 man) consumed 7, 15, and 25 g of pyruvate and were monitored for a 4-h period to determine whether blood metabolites were altered. Pyruvate consumption failed to significantly elevate blood pyruvate, and it had no effect on indexes of carbohydrate (blood glucose, lactate) or lipid metabolism (blood glycerol, plasma free fatty acids). As a follow-up, we administered 7 g/day of either placebo or pyruvate, for a 1-wk period to seven, well-trained male cyclists (maximal oxygen consumption, 62.3 +/- 3.0 ml. kg(-1). min(-1)) in a randomized, double-blind, crossover trial. Subjects cycled at 74-80% of their maximal oxygen consumption until exhaustion. There was no difference in performance times between the two trials (placebo, 91 +/- 9 min; pyruvate, 88 +/- 8 min). Measured blood parameters (insulin, peptide C, glucose, lactate, glycerol, free fatty acids) were also unaffected. Our results indicate that oral pyruvate supplementation does not increase blood pyruvate content and does not enhance performance during intense exercise in well-trained cyclists.

Randomized Controlled Trial↗

Acute effect of ephedrine on 24-h energy balance

Ephedrine is used to help achieve weight control. Data on its true efficacy and mechanisms in altering energy balance in human subjects are limited. We aimed to determine the acute effect of ephedrine on 24-h energy expenditure, mechanical work and urinary catecholamines in a double-blind, randomized, placebo-controlled, two-period crossover study. Ten healthy volunteers were given ephedrine (50 mg) or placebo thrice daily during each of two 24-h periods (ephedrine and placebo) in a whole-room indirect calorimeter, which accurately measures minute-by-minute energy expenditure and mechanical work. Measurements were taken of 24-h energy expenditure, mechanical work, urinary catecholamines and binding of (+/-)ephedrine in vitro to human beta1-, beta2- and beta3-adrenoreceptors. Twenty-four-hour energy expenditure was 3.6% greater (8965+/-1301 versus 8648+/-1347 kJ, P<0.05) with ephedrine than with placebo, but mechanical work was not different between the ephedrine and placebo periods. Noradrenaline excretion was lower with ephedrine (0.032+/-0.011 microg/mg creatinine) compared with placebo (0.044+/-0.012 microg/mg creatinine) (P<0.05). (+/-)Ephedrine is a relatively weak partial agonist of human beta1- and beta2-adrenoreceptors, and had no detectable activity at human beta3-adrenoreceptors. Ephedrine (50 mg thrice daily) modestly increases energy expenditure in normal human subjects. A lack of binding of ephedrine to beta3-adrenoreceptors and the observed decrease in urinary noradrenaline during ephedrine treatment suggest that the thermogenic effect of ephedrine results from direct beta1-/beta2-adrenoreceptor agonism. An indirect beta3-adrenergic effect through the release of noradrenaline seems unlikely as urinary noradrenaline decreased significantly with ephedrine.

Non-NASA Center↗

Evidence for increased cardiac compliance during exposure to simulated microgravity

We measured hemodynamic responses during 4 days of head-down tilt (HDT) and during graded lower body negative pressure (LBNP) in invasively instrumented rhesus monkeys to test the hypotheses that exposure to simulated microgravity increases cardiac compliance and that decreased stroke volume, cardiac output, and orthostatic tolerance are associated with reduced left ventricular peak dP/dt. Six monkeys underwent two 4-day (96 h) experimental conditions separated by 9 days of ambulatory activities in a crossover counterbalance design: 1) continuous exposure to 10 degrees HDT and 2) approximately 12-14 h per day of 80 degrees head-up tilt and 10-12 h supine (control condition). Each animal underwent measurements of central venous pressure (CVP), left ventricular and aortic pressures, stroke volume, esophageal pressure (EsP), plasma volume, alpha1- and beta1-adrenergic responsiveness, and tolerance to LBNP. HDT induced a hypovolemic and hypoadrenergic state with reduced LBNP tolerance compared with the control condition. Decreased LBNP tolerance with HDT was associated with reduced stroke volume, cardiac output, and peak dP/dt. Compared with the control condition, a 34% reduction in CVP (P = 0.010) and no change in left ventricular end-diastolic area during HDT was associated with increased ventricular compliance (P = 0.0053). Increased cardiac compliance could not be explained by reduced intrathoracic pressure since EsP was unaltered by HDT. Our data provide the first direct evidence that increased cardiac compliance was associated with headward fluid shifts similar to those induced by exposure to spaceflight and that reduced orthostatic tolerance was associated with lower cardiac contractility.

Non-NASA Center↗

Advances in Measuring Antarctic Sea-Ice Thickness and Ice-Sheet Elevations with ICESat Laser Altimetry

NASA's Ice, Cloud and Land Elevation Satellite (ICESat) has been measuring elevations of the Antarctic ice sheet and sea-ice freeboard elevations with unprecedented accuracy. Since February 20,2003, data has been acquired during three periods of laser operation varying from 36 to 54 days, which is less than the continuous operation of 3 to 5 years planned for the mission. The primary purpose of ICESat is to measure time-series of ice-sheet elevation changes for determination of the present-day mass balance of the ice sheets, study of associations between observed ice changes and polar climate, and estimation of the present and future contributions of the ice sheets to global sea level rise. ICESat data will continue to be acquired for approximately 33 days periods at 3 to 6 month intervals with the second of ICESat's three lasers, and eventually with the third laser. The laser footprints are about 70 m on the surface and are spaced at 172 m along-track. The on-board GPS receiver enables radial orbit determinations to an accuracy better than 5 cm. The orbital altitude is around 600 km at an inclination of 94 degrees with a 8-day repeat pattern for the calibration and validation period, followed by a 91 -day repeat period for the rest of the mission. The expected range precision of single footprint measurements was 10 cm, but the actual range precision of the data has been shown to be much better at 2 to 3 cm. The star-tracking attitude-determination system should enable footprints to be located to 6 m horizontally when attitude calibrations are completed. With the present attitude calibration, the elevation accuracy over the ice sheets ranges from about 30 cm over the low-slope areas to about 80 cm over areas with slopes of 1 to 2 degrees, which is much better than radar altimetry. After the first period of data collection, the spacecraft attitude was controlled to point the laser beam to within 50 m of reference surface tracks over the ice sheets. Detection of ice elevation changes over select areas of the ice sheet is demonstrated with using both crossover analysis and precise-repeat track analysis. Sea ice freeboard-height distributions over the Antarctic sea pack are derived over distances of 50 km and converted into maps of average freeboard thickness and sea-ice thickness.

Zwally, H. Jay↗

Drug marker absorption in relation to pellet size, gastric motility and viscous meals in humans

PURPOSE: The objective of this study was to evaluate drug marker absorption in relation to the gastric emptying (GE) of 0.7 mm and 3.6 mm enteric coated pellets as a function of viscosity and the underlying gastric motility. METHODS: Twelve subjects were evaluated in a 3-way crossover study. 0.7 mm caffeine and 3.6 mm acetaminophen enteric coated pellets were concurrently administered with a viscous caloric meal at the levels of 4000, 6000 and 8000 cP. Gastric motility was simultaneously measured with antral manometry and compared to time events in the plasma profiles of the drug markers. RESULTS: Caffeine, from the 0.7 mm pellets, was observed significantly earlier in the plasma than acetaminophen, from the 3.6 mm pellets, at all levels of viscosity. Motility related size differentiated GE was consistently observed at all viscosity levels, however, less variability was observed with the 4000 cP meal. Specifically, the onset of absorption from the of 3.6 mm pellets correlated with the onset of Phase II fasted state contractions (r = 0.929, p < 0.01). CONCLUSIONS: The timeframe of drug marker absorption and the onset of motility events were not altered within the range of viscosities evaluated. Rather, the differences in drug marker profiles from the non-digestible solids were most likely the result of the interaction between viscosity and motility influencing antral flow dynamics. The administration of the two sizes of pellets and a viscous caloric meal with subsequent monitoring of drug marker profiles is useful as a reference to assess the influence of motility patterns on the absorption profile of orally administered agents.

NASA Center JSC↗

Age-related alterations in the fractal scaling of cardiac interbeat interval dynamics

We postulated that aging is associated with disruption in the fractallike long-range correlations that characterize healthy sinus rhythm cardiac interval dynamics. Ten young (21-34 yr) and 10 elderly (68-81 yr) rigorously screened healthy subjects underwent 120 min of continuous supine resting electrocardiographic recording. We analyzed the interbeat interval time series using standard time and frequency domain statistics and using a fractal measure, detrended fluctuation analysis, to quantify long-range correlation properties. In healthy young subjects, interbeat intervals demonstrated fractal scaling, with scaling exponents (alpha) from the fluctuation analysis close to a value of 1.0. In the group of healthy elderly subjects, the interbeat interval time series had two scaling regions. Over the short range, interbeat interval fluctuations resembled a random walk process (Brownian noise, alpha = 1.5), whereas over the longer range they resembled white noise (alpha = 0.5). Short (alpha s)- and long-range (alpha 1) scaling exponents were significantly different in the elderly subjects compared with young (alpha s = 1.12 +/- 0.19 vs. 0.90 +/- 0.14, respectively, P = 0.009; alpha 1 = 0.75 +/- 0.17 vs. 0.99 +/- 0.10, respectively, P = 0.002). The crossover behavior from one scaling region to another could be modeled as a first-order autoregressive process, which closely fit the data from four elderly subjects. This implies that a single characteristic time scale may be dominating heartbeat control in these subjects. The age-related loss of fractal organization in heartbeat dynamics may reflect the degradation of integrated physiological regulatory systems and may impair an individual's ability to adapt to stress.

NASA Discipline Cardiopulmonary↗

Pre-exercise glycerol hydration improves cycling endurance time

The effects of glycerol ingestion (GEH) on hydration and subsequent cycle ergometer submaximal load exercise were examined in well conditioned subjects. We hypothesized that GEH would reduce physiologic strain and increase endurance. The purpose of Study I (n = 11) was to determine if pre-exercise GEH (1.2 gm/kg glycerol in 26 ml/kg solution) compared to pre-exercise placebo hydration (PH) (26 ml/kg of aspartame flavored water) lowered heart rate (HR), lowered rectal temperature (Tc), and prolonged endurance time (ET) during submaximal load cycle ergometry. The purpose of Study II (n = 7) was to determine if the same pre-exercise regimen followed by carbohydrate oral replacement solution (ORS) during exercise also lowered HR, Tc, and prolonged ET. Both studies were double-blind, randomized, crossover trials, performed at an ambient temperature of 23.5-24.5 degrees C, and humidity of 25-27%. Mean HR was lower by 2.8 +/- 0.4 beats/min (p = 0.05) after GEH in Study I and by 4.4 +/- 1.1 beats/min (p = 0.01) in Study II. Endurance time was prolonged after GEH in Study I (93.8 +/- 14 min vs. 77.4 +/- 9 min, p = 0.049) and in Study II (123.4 +/- 17 min vs. 99.0 +/- 11 min, p = 0.03). Rectal temperature did not differ between hydration regimens in both Study I and Study II. Thus, pre-exercise glycerol-enhanced hyperhydration lowers HR and prolongs ET even when combined with ORS during exercise. The regimens tested in this study could potentially be adapted for endurance activities.

Non-NASA Center↗

High Temperature Performance of a SiC MESFET Based Oscillator

A hybrid, UHF-Band differential oscillator based on 10 w SiC RF Power Metal Semiconductor Field Effect Transistor (MESFET) has been designed, fabricated and characterized through 475 C. Circuit is fabricated on an alumina substrate with thin film spiral inductors, chip capacitors, chip resistors, and wire bonds for all crossovers and interconnectors. The oscillator delivers 15.7 dBm at 515 MHz into a 50 Ohm load at 125 C with a DC to RF conversion efficiency of 2,8%. After tuning the load impedance, the oscillator delivers 18.8 dBm at 610 MHz at 200 C with a DC to RF conversion efficiency of 5.8%. Finally, by tuning the load and bias conditions, the oscillator delivers 4.9 dBm at 453 MHz at 475 C.

Schwartz, Zachary D.↗

Southern Alaska Glaciers: Spatial and Temporal Variations in Ice Volume

Although temperate mountain glaciers comprise less than 1% of the glacier-covered area on Earth, they are important because they appear to be melting rapidly under present climatic conditions and, therefore, make significant contributions to rising sea level. In this study, we use ICESat observations made in the last 1.5 years of southern Alaska glaciers to estimate ice elevation profiles, ice surface slopes and roughness, and bi-annual and/or annual ice elevation changes. We report initial results from the near coastal region between Yakutat Bay and Cape Suckling that includes the Malaspina and Bering Glaciers. We show and interpret ice elevations changes across the lower reaches of the Bagley Ice Valley for the period between October 2003 and May 2004. In addition, we use off-nadir pointing observations to reference tracks over the Bering and Malaspina Glaciers in order to estimate annual ice elevation change. Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) and Shuttle Radar Topography Mission (SRTM) derived DEMs are used to estimate across track regional slopes between ICESat data acquisitions. Although the distribution and quantity of ICESat elevation profiles with multiple, exact repeat data is currently limited in Alaska, individual ICESat data tracks, provide an accurate reference surface for comparison to other elevation data (e.g. ASTER and SRTM X- and C-band derived DEMs). Specifically we report the elevation change over the Malaspina Glacier's piedmont lobe between a DEM derived from SRTM C-band data acquired in Feb. 2000 and ICESat Laser #2b data from Feb.-March 2004. We also report use of ICESat elevation data to enhance ASTER derived absolute DEMs. Mountain glaciers generally have rougher surfaces and steeper regional slopes than the ice sheets for which the ICESat design was optimized. Therefore, rather than averaging ICESat observations over large regions or relying on crossovers, we are working with well-located ICESat footprint returns to estimate glacier ice elevations and surface characteristics. Additional information is included in the original extended abstract.

Sauber, J.↗

Recent Results in ICESat Geolocation Parameter Calibration from Range Residual Analysis

The Ice, Cloud and land Elevation Satellite (ICESat), launched on January 12, 2003, carries the Geoscience Laser Altimeter System (GLAS), which has a primary measurement of short-pulse laser-ranging to the Earths surface at 1064 nm wavelength at a rate of 40 pulses per second. The instrument has collected (at the time of this writing) over 540 million observations of the Earth's surface including precise elevation measurements of the ice sheets, sea ice roughness and thickness, ocean and land surface elevations and surface reflectivity. The accurate geolocation of GLASs surface returns, the spots from which the laser energy reflects on the Earths surface, is a critical issue in the scientific application of these data. Pointing, ranging, timing and orbit errors must be compensated to accurately geolocate the laser altimeter surface returns. Towards this end, the laser range observations can be fully exploited in an integrated residual analysis to accurately calibrate these geolocation/instrument parameters. The ICESat laser altimeter data have been simultaneously processed as direct altimetry from ocean sweeps and around-the-world scans along with dynamic crossovers in order to calibrate pointing ranging and timing. The analysis has resolved complex time varying signal resulting from thermal variations of instrument pointing and boresite shadowing. The calibration methodology and current calibration results are discussed along with future efforts and current geolocation accuracies.

Luthcke, Scott B.↗

Electrical Conductivity of HgTe at High Temperatures

The electrical conductivity of HgTe was measured using a rotating magnetic field method from 300 K to the melting point (943 K). A microscopic theory for electrical conduction was used to calculate the expected temperature dependence of the HgTe conductivity. A comparison between the measured and calculated conductivities was used to obtain the estimates of the temperature dependence of Gamma(sub 6)-Gamma(sub 8) energy gap from 300 K to 943 K. The estimated temperature coefficient for the energy gap was comparable to the previous results at lower temperatures (less than or equal to 300 K). A rapid increase in the conductivity just above 300 K and a subsequent decrease at 500 K is attributed to band crossover effects. This paper describes the experimental approach and some of the theoretical calculation details.

Li, C.↗

Lunar and Planetary Science XXXVI, Part 14

Contents include the following: Destruction of Presolar Silicates by Aqueous Alteration Observed in Murchison CM2 Chondrite. Generation of Chondrule Forming Shock Waves in Solar Nebula by X-Ray Flares. TEM and NanoSIMS Study of Hydrated/Anhydrous Phase Mixed IDPs: Cometary or Asteroidal Origin? Inflight Calibration of Asteroid Multiband Imaging Camera Onboard Hayabusa: Preliminary Results. Corundum and Corundum-Hibonite Grains Discovered by Cathodoluminescence in the Matrix of Acfer 094 Meteorite. Spatial Extent of a Deep Moonquake Nest A Preliminary Report of Reexamination. Modal Abundances of Carbon in Ureilites: Implications for the Petrogenesis of Ureilites. Trapped Noble Gas Components and Exposure History of the Enstatite Chondrite ALH84206. Deep-seated Crustal Material in Dhofar Lunar Meteorites: Evidence from Pyroxene Chemistry. Numerical Investigations of Kuiper Belt Binaries. Dust Devils on Mars: Effects of Surface Roughness on Particle Threshold. Hecates Tholus, Mars: Nighttime Aeolian Activity Suggested by Thermal Images and Mesoscale Atmospheric Model Simulations. Are the Apollo 14 High-Al Basalts Really Impact Melts? Garnet in the Lunar Mantle: Further Evidence from Volcanic Glass Beads. The Earth/Mars Dichotomy in Mg/Si and Al/Si Ratios: Is It Real? Dissecting the Polar Asymmetry in the Non-Condensable Gas Enhancement on Mars: A Numerical Modeling Study. Cassini VIMS Preliminary Exploration of Titan s Surface Hemispheric Albedo Dichotomy. An Improved Instrument for Investigating Planetary Regolith Microstructure. Isotopic Composition of Oxygen in Lunar Zircons Preliminary Design of Visualization Tool for Hayabusa Operation. Size and Shape Distributions of Chondrules and Metal Grains Revealed by X-Ray Computed Tomography Data. Properties of Permanently Shadowed Regolith. Landslides in Interior Layered Deposits, Valles Marineris, Mars: Effects of Water and Ground Shaking on Slope Stability. Mars: Recent and Episodic Volcanic, Hydrothermal, and Glacial Activity Revealed by Mars Express High Resolution Stereo Camera (HRSC). The Cratering Record of the Saturnian Satellites Phoebe, Tethys, Dione and Iapetus in Comparison: First Results from Analysis of the Cassini ISS Imaging Data. Joint Crossover Solutions of Altimetry and Image Data on 433 Eros. The Martian Soil as a Geochemical Sink for.

Source record↗

Evolution of the Electron Yield Curves of Insulators as a Function of Impinging Electron Fluence and Energy

Electron emission and concomitant change accumulation near the surface of insulators in central to understanding spacecraft charging. We present a study of changes in electron emission yields as a result of internal charge build up due to electron dose. Evolution of total, backscattered and secondary yield results over a broad range of incident energies are presented for two representative insulators, Kapton(trademark) and Al2O3. Reliable yield curves for uncharged insulators are measured and quantifiable changes in yield are observed due to < 100 fC/sq mm fluences. We find excellent agreement with a phenomenological argument based on insulator charging predicted by the yield curve; this includes a decrease in the rate of change of the yield as incident energies approach the crossover energies and as accumulated internal charge reduces the landing energy to asymptotically approach a steady state surface charge and unity yield. We also find that the exponential decay of yield curves with fluence exhibit an energy dependent decay constant, alpha(E). Finally, we discuss physics based models for this energy dependence. To understand fluence and energy dependence of these charging processes requires knowledge of how charge is deposited within the insulator, the mechanisms for charge trapping and transport within the insulator, and how the profile of trapped charge affects the transport and emission of charges from insulators.

Sim, Alec↗

Effect of contrast on the active control of a moving line

In many passive visual tasks, human perceptual judgments are contrast dependent. To explore whether these contrast dependencies of visual perception also affect closed-loop manual control tasks, we examined visuomotor performance as humans actively controlled a moving luminance-defined line over a range of contrasts. Four subjects were asked to use a joystick to keep a horizontal line centered on a display as its vertical position was perturbed by a sum of sinusoids under two control regimes. The total root mean square (RMS) position error decreased quasi-linearly with increasing log contrast across the tested range (mean slope across subjects: -8.0 and -7.7% per log2 contrast, for the two control regimes, respectively). Frequency-response (Bode) plots showed a systematic increase in open-loop gain (mean slope: 1.44 and 1.30 dB per log2 contrast, respectively), and decrease in phase lag with increasing contrast, which can be accounted for by a decrease in response time delay (mean slope: 32 and 40 ms per log2 contrast, respectively). The performance data are well fit by a Crossover Model proposed by McRuer and Krendel, which allowed us to identify both visual position and motion cues driving performance. This analysis revealed that the position and motion cues used to support manual control under both control regimes appear equally sensitive to changes in stimulus contrast. In conclusion, our data show that active control of a moving visual stimulus is as dependent on contrast as passive perception and suggest that this effect is attributed to a shared contrast sensitivity early in the visual pathway, before any specialization for motion processing.

Contrast Sensitivity/physiology↗