Search NASA⌕ Search

SEARCH · Search NASA

Results for “dc”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Initial Results of DC Electric Fields, Associated Plasma Drifts, Magnetic Fields, and Plasma Waves Observed on the C/NOFS Satellite

Initial results are presented from the Vector Electric Field Investigation (VEFI) on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite, a mission designed to understand, model, and forecast the presence of equatorial ionospheric irregularities. The VEFI instrument includes a vector DC electric field detector, a fixed-bias Langmuir probe operating in the ion saturation regime, a flux gate magnetometer, an optical lightning detector, and associated electronics including a burst memory. Compared to data obtained during more active solar conditions, the ambient DC electric fields and their associated E x B drifts are variable and somewhat weak, typically < 1 mV/m. Although average drift directions show similarities to those previously reported, eastward/outward during day and westward/downward at night, this pattern varies significantly with longitude and is not always present. Daytime vertical drifts near the magnetic equator are largest after sunrise, with smaller average velocities after noon. Little or no pre-reversal enhancement in the vertical drift near sunset is observed, attributable to the solar minimum conditions creating a much reduced neutral dynamo at the satellite altitude. The nighttime ionosphere is characterized by larger amplitude, structured electric fields, even where the plasma density appears nearly quiescent. Data from successive orbits reveal that the vertical drifts and plasma density are both clearly organized with longitude. The spread-F density depletions and corresponding electric fields that have been detected thus far have displayed a preponderance to appear between midnight and dawn. Associated with the narrow plasma depletions that are detected are broad spectra of electric field and plasma density irregularities for which a full vector set of measurements is available for detailed study. Finally, the data set includes a wide range of ELF/VLF/HF oscillations corresponding to a variety of plasma waves, in particular banded ELF hiss, whistlers, and lower hybrid wave turbulence triggered by lightning-induced sferics. The VEFI data represents a new set of measurements that are germane to numerous fundamental aspects of the electrodynamics and irregularities inherent to the Earth's low latitude ionosphere.

Pfaff, R.↗

DC Electric Fields, Associated Plasma Drifts, and Irregularities Observed on the C/NOFS Satellite

Results are presented from the Vector Electric Field Investigation (VEFI) on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite, a mission designed to understand, model, and forecast the presence of equatorial ionospheric irregularities. The VEFI instrument includes a vector DC electric field detector, a fixed-bias Langmuir probe operating in the ion saturation regime, a flux gate magnetometer, an optical lightning detector, and associated electronics including a burst memory. Compared to data obtained during more active solar conditions, the ambient DC electric fields and their associated E x B drifts are variable and somewhat weak, typically < 1 mV/m. Although average drift directions show similarities to those previously reported, eastward/outward during day and westward/downward at night, this pattern varies significantly with longitude and is not always present. Daytime vertical drifts near the magnetic equator are largest after sunrise, with smaller average velocities after noon. Little or no pre-reversal enhancement in the vertical drift near sunset is observed, attributable to the solar minimum conditions creating a much reduced neutral dynamo at the satellite altitude. The nighttime ionosphere is characterized by larger amplitude, structured electric fields, even where the plasma density appears nearly quiescent. Data from successive orbits reveal that the vertical drifts and plasma density are both clearly organized with longitude. The spread-F density depletions and corresponding electric fields that have been detected thus far have displayed a preponderance to appear between midnight and dawn. Associated with the narrow plasma depletions that are detected are broad spectra of electric field and plasma density irregularities for which a full vector set of measurements is available for detailed study. The VEFI data represents a new set of measurements that are germane to numerous fundamental aspects of the electrodynamics and irregularities inherent to the Earth s low latitude ionosphere.

Pfaff, R.↗

A Study of the Degradation of Electronic Speed Controllers for Brushless DC Motors

Brushless DC motors are frequently used in electric aircraft and other direct drive applications. As these motors are notactually direct current machines but synchronous alternating current machines; they are electronically commutated by a power inverter. The power inverter for brushless DC motors typically used in small scale UAVs is a semiconductor base delectronic commutator that is external to the motor and is referred to as an electronic speed control (ESC). This paper examines the performance changes of a UAV electric propulsion system resulting from ESC degradation. ESC performance is evaluated in simulation and on a new developed test bed featuring propulsion components from a reference UAV. An increase in the rise fall times of the switched voltages is expected to cause timing issues at high motor speeds. This study paves the way for further development of diagnostic and prognostic methods for inverter circuits which are part of the overall electric UAV system.

Gorospe, George E., Jr.↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the IKP2 isokinetic evaporator probe, which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window ice crystal detector to the measurements made with the underwing and nose Ice Crystal Detectors The key findings were: 1) the Ice Crystal Detector total water content sensor ice water content efficiency factor was similar to previous estimates, but reduced with increased ice crystal median mass diameter; 2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values – although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and 3) the ice water content at the 17” standoff from the port window varied from about 50% to 3 times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

Aircraft Icing↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the IKP2 isokinetic evaporator probe, which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window ice crystal detector to the measurements made with the underwing and nose Ice Crystal Detectors The key findings were: 1) the Ice Crystal Detector total water content sensor ice water content efficiency factor was similar to previous estimates, but reduced with increased ice crystal median mass diameter; 2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values – although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and 3) the ice water content at the 17” standoff from the port window varied from about 50% to 3 times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

o Aircraft Icing↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector concave total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the Isokinetic Probe version 2 (IKP2), which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window probes to the measurements made with the underwing and nose probes. The key findings were: (1) the Ice Crystal Detector concave water content sensor efficiency factor to glaciated conditions was similar to previous estimates, but reduced with increased ice crystal median mass diameter; (2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values—although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and (3) the ice water content at the 17 in. standoff from the port window varied from about 50 percent to nearly three times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

Aircraft Icing↗

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains - Task 2: Power Quality Filtering Using Nanocrystalline Soft Magnetic Inductor

The NASA RTAPS program on AC and DC Fault Management for Megawatt Electrified Power Train is a multi-year joint project with Pratt & Whitney (P&W), Collins Aerospace (CA), and RTX Technology Research Center (RTRC). This research program focuses on the high-voltage distribution issues that present a significant technological obstacle in the adoption of Electrified Aviation Propulsion (EAP) systems. One challenge to the adoption of high-voltage distribution systems with power electronic converters is the need for filter elements to limit the generation and propagation of noise, protect the cable systems from premature aging and prevent against excessive heating within subcomponents due to high-frequency induced currents. While increased distribution voltages aide in reducing the cable mass for a fixed power system, the associated mass with the filtering elements for power electronic converter can grow with increasing distribution voltages – thereby mitigating any benefit associated with increasing the distribution system voltage. To enable high-voltage distribution systems with high system specific power densities, new magnetic materials must be developed. Therefore, the second task of the NASA RTAPS program is associated with the design and application of advanced soft magnetic components for Megawatt class electric propulsion systems, specifically the motor drive system. This report covers the collaborative work between NASA Glenn Research Center (GRC), RTRC, P&W and CA in the development of three types of magnetic components over the span of the three-year program. These critical magnetic components are the DC side EMI filter, which limits the propagation of harmful electromagnetic noise to the rise of the distribution system, and the AC side damping with the dv/dt filter, which limits the fast rise time of the power electronic converter output voltage to limit the degradation on the cable/motor insulation systems. Each of these components are investigated from component level design and are optimized at the system level with a combined modelling and testing effort. In the final experimental evaluation of the NASA developed soft magnetic material with a dv/dt filter, a commercial-off-the-shelf (COTS) magnetic core and the GRC magnetic core are optimized and loaded at 320Arms to evaluate their difference in performance. After a run time of 30 minutes in a MW-class motor driver at RTRC, the NASA GRC cores were found to not only offer a lower temperature rise of nearly 25°𝐶, but also a reduction in measured core loss of 25% (12.75W to 9.5W).

Elecrified Aircraft Propulsion↗

Wind turbine power phase control with DC collection bus for onshore/offshore windfarms

A DC bus collection system for a wind farm reduces the overall required number of converters and minimizes the energy storage system requirements. The DC bus collection system implements a power phasing control method between wind turbines that filters the variations and improves power quality. The phasing control method takes advantage of a novel power packet network concept with nonlinear power flow control design techniques that guarantees both stable and enhanced dynamic performance.

Weaver, Wayne W.↗

Stability Considerations for Virtual Capacitor Control in Constant Power DC Loads

In a DC grid, constant power loads (CPLs) necessitate a large bus capacitor to prevent negative impedance instability. Some of the capacitance can be realized virtually through CPL control to reduce the bus capacitor size. Here, this paper analytically studies system stability with virtual capacitor control. We demonstrate that the effectiveness of virtual capacitor control is highly sensitive to the implementation of the derivative action required to emulate the capacitor. For the first time, we theoretically demonstrate that a virtual capacitor can stabilize the system without any physical bus capacitor, provided that a set of analytically derived conditions are met. However, this stabilization is not achievable in practice due to the influence of non-idealities. In an example system requiring a $14$ mF capacitor to stably support the CPL, we show that stability can be achieved through virtual capacitor control, using only a 2 mF physical capacitor to account for the switching ripple non-idealities. Hardware-in-the-loop tests verify the analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Control Strategy With Efficiency and Reliability Improvement for Offshore DC Microgrids

Offshore microgrids, due to their remote location and lack of external energy support, face significant challenges in wide-range load operation and maintenance. Consequently, efficiency and reliability are critical concerns for converters in offshore dc microgrids. This article presents an optimal control strategy aimed at enhancing both efficiency and reliability. A normalized nonlinear relationship between power loss and thermal stress of a paralleled converter is first established. Based on this, a dual-objective optimization function with an active weight function as well as a system overall performance index is established. The active weight function dynamically adjusts the control priority based on converter efficiency and switching device thermal stress. Then, the optimal power-sharing strategy is derived by the Lagrange multiplier method with the proposed optimal function. Additionally, to accommodate a wide load range, an optimal selection strategy for operating converter combinations is proposed, requiring only low-bandwidth communication. Experiment verification is given to validate the effectiveness of the proposed control strategy. The experiment results demonstrate that the proposed control strategy can improve the overall performance of offshore microgrids by optimizing efficiency and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Users Guide for NASA Lewis Research Center DC-9 Reduced-Gravity Aircraft Program

The document provides guidelines and information for users of the DC-9 Reduced-Gravity Aircraft Program. It describes the facilities, requirements for test personnel, equipment design and installation, mission preparation, and in-flight procedures. Those who have used the KC-135 reduced-gravity aircraft will recognize that many of the procedures and guidelines are the same.

DC-9↗

DC Magnetics Measurement System Design

This report will detail the updates to the magnetics measurement system design and testing procedures that are required for performing static (DC) magnetics testing of future flight hardware. An older magnetics testing system had to be integrated with new procedures and hardware to meet the demands of future testing programs and accommodate an upcoming magnetics tests. The next test will be for the Geostationary Operational Environmental Satellite R-Series (GOES-R), which will verify that the SAFT Battery component meets its specifications for magnetic cleanliness. The satellite is scheduled to launch in 2015 with magnetics testing to be completed on the battery in November 2012.

DC magnetics↗

Bifurcation Analysis of DC Electric Power Systems for Deep Space Exploration Spacecraft

Electric power system reliability is a crucial factor in the application of both manned and unmanned spacecraft that could alter the success of space exploration missions. Understanding the behavior of these electric systems is essential to determine the safe operating conditions, and subsequently, prevent undesired conditions which may cause system-wide blackouts, leaving the spacecraft in a vulnerable position. This study will use bifurcation analysis to determine the behavior of DC spacecraft electric power systems and identify the major causes of voltage instability.

Bifurcation Analysis↗

Development of an Adaptive Droop Control Method for Interconnected Lunar DC Microgrids Using Power Hardware-in-the-Loop

NASA’s Artemis Program outlines the need for a habitat capable of sustaining human life as well as mining and producing raw materials on the lunar surface. This mission is viewed as a means towards deeper space exploration, with plans for reaching Mars and beyond. Human presence on the moon is not possible without the ability to generate and distribute energy, namely electricity, through a network of energy sources, loads, and power converters called a microgrid. Multiple microgrids can be deployed on the moon based on location and need. Separate microgrids will require interconnection to increase resiliency and reliability given the mission’s high criticality. A method for adaptive control over power converters connecting two dc microgrids is proposed. A simulation is modeled after the lunar power system with two approaches to power converter droop control, allowing for a more flexible and adaptive microgrid architecture. Further experiments are conducted using the control methods in a power hardware-in-the-loop test environment to study the performance of hardware converter control used in this application.

dc microgrid↗

Progress toward absolute calibrations of DC x-ray sources from 1 keV to >30 keV for Z diagnostics applications

Numerous x-ray diagnostics at the Z facility, time-resolved and time-integrated, would benefit from a local calibrated x-ray source. For many years, Z has used low-power Manson x-ray sources to provide some characterization information for components of Z diagnostics below 30 keV. More recently, we have acquired TruFocus x-ray sources, which operate at voltages up to 100 kV depending on the anode material and model. These DC sources have demonstrated good stability and repeatability. Absolute calibrations of either sources or detectors usually involve another calibrated detector from another source, which has not been readily available locally. Therefore, we have adopted the strategy of characterizing a sensitive semiconductor diode detector by controlling or inferring the active volume. This characterized detector is then used to scale the Manson x-ray spectral shape as measured by an Amptek energy-resolving detector. Here, the result agrees well with the modeled source spectrum. We can apply this technique to the TruFocus as well.

Crystal spectroscopy↗

SCR-based Medium Voltage DC Solid-State Circuit Breaker

This paper describes a medium voltage solid-state circuit breaker (SSCB) based on SCR technology, featuring short fault-interruption time and a minimal turn-off auxiliary circuit. The SSCB design incorporates a specialized SCR and a commutation circuit designed with an objective to reduce the required SCR hold-off/turn-off time, tq, which primarily determines the fault interruption duration. To validate the design, simulation analysis is presented, and a 1.5 kV 300 A SSCB prototype has been built and tested. The results confirm the effectiveness of the proposed design philosophy demonstrating the SSCB's ability to interrupt a 200 A load current in less than 50 μs. The proposed SCR-based SSCB has been developed for DC applications but is equally applicable to AC applications.

Kandula, Prasad [ORNL] (ORCID:0000000174017284)↗