Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Holographic optical interconnects for VLSI

This paper introduces new applications and design trade-offs anticipated for free-space optical interconnections of VLSI chips. New implementation s of VLSI functions are described that use the capability of making optical inputs at any point on a chip and take advantage of greater flexibility in on-chip signal routing. These include n-port addressable memories, CPU clock phase distribution, hardware multipliers, and dynamic memory refresh, as well as enhanced testability. Fault tolerance and production yields may be improved by reprogramming the optical imaging system to circumvent defective elements. These attributes, as well as those related to performance alone, will affect the design methodology of future VLSI ICs. This paper focuses on identifying the design issues, their possible solutions, and their impact on VLSI design techniques and, finally, presents some preliminary measurements on various system components.

Bergman, L. A.↗

Programmable remapper for image processing

A video-rate coordinate remapper includes a memory for storing a plurality of transformations on look-up tables for remapping input images from one coordinate system to another. Such transformations are operator selectable. The remapper includes a collective processor by which certain input pixels of an input image are transformed to a portion of the output image in a many-to-one relationship. The remapper includes an interpolative processor by which the remaining input pixels of the input image are transformed to another portion of the output image in a one-to-many relationship. The invention includes certain specific transforms for creating output images useful for certain defects of visually impaired people. The invention also includes means for shifting input pixels and means for scrolling the output matrix.

Juday, Richard D.↗

Visualization of Subsurface Defects in Composites using a Focal Plane Array Infrared Camera

A technique for enhanced defect visualization in composites via transient thermography is presented in this paper. The effort targets automated defect map construction for multiple defects located in the observed area. Experimental data were collected on composite panels of different thickness with square inclusions and flat bottom holes of different depth and orientation. The time evolution of the thermal response and spatial thermal profiles are analyzed. The pattern generated by carbon fibers and the vignetting effect of the focal plane array camera make defect visualization difficult. An improvement of the defect visibility is made by the pulse phase technique and the spatial background treatment. The relationship between a size of a defect and its reconstructed image is analyzed as well. The image processing technique for noise reduction is discussed.

Plotnikov, Yuri A.↗

Inspection 13.2 nm table-top full-field microscope

We present results on a table-top microscope that uses an EUV stepper geometry to capture full-field images with a halfpitch spatial resolution of 55 nm. This microscope uses a 13.2 nm wavelength table-top laser for illumination and acquires images of reflective masks with exposures of 20 seconds. These experiments open the path to the realization of high resolution table-top imaging systems for actinic defect characterization.

36 MATERIALS SCIENCE↗

Degradation of CVD-Grown MoS2 Subjected to DC Electrical Stress

Devices containing transition metal dichalcogenides are being investigated for next generation electronics. Understanding material properties under typical use conditions is important for the longevity and effectiveness of these devices. In this study, CVD-grown MoS2 crystals with pre-existing defects from the growth process were subjected to DC-voltages of 10 V, 20 V, and 40 V for up to 96 h. The presence of pre-existing defects was found to lead to more extensive material damage that scales with voltage and time. SEM, AFM, Raman and photoluminescence imaging indicated regions of increased defect concentration post-electrical stress.

2D materials↗

Complete Performance Comparison Between the Optimized Image Construction Algorithm (U-MBIR) and the Existing Reconstruction Algorithm for Detecting Defects and Damage in Concrete

Reinforced concrete (RC) is a composite material subjected to mechanical, thermal, and chemical loads throughout its service life. Because of these external stressors and the susceptibility of RC structural members to shrinkage and microcracking, the material degrades throughout its life cycle. This deterioration can lead to a decrease in member capacity and, ultimately, poses a threat to the structural integrity. Thus, it is crucial that the damage caused by aging and degradation be monitored and assessed at regular intervals throughout the material’s service life. Since coring of the material is typically not feasible for in-service structural systems, non-destructive evaluation (NDE) methodologies are used to assess remaining structural capacity. NDE methods enable surface and subsurface examination without damaging or degrading the medium. Moreover, RC is a critical component of nuclear power plants; thus, its safety and reliability must be thoroughly examined throughout the life cycle of the structural system. Ultrasonic measurements have been an industry standard for both surface and subsurface inspections. To this end, Oak Ridge National Laboratory (ORNL) has researched and developed advanced image reconstruction algorithms to capture internal damage. The results and discussion presented herein summarize the current state of the ultrasonic model–based iterative reconstruction (U-MBIR) algorithm developed at ORNL. More specifically, this report presents a comparison between reconstruction images produced via a widely employed ultrasonic NDE technique—the synthetic aperture focusing technique (SAFT)—and the ORNL-developed U-MBIR algorithm. These NDE methodologies are demonstrated using ultrasonic data collected from four concrete specimens. Overall, the U-MBIR algorithm eliminates artifacts and noise that are typically present within the SAFT reconstructions, and it shows defects and anomalies more clearly than the SAFT images. In conclusion, this algorithm is suitable for identifying concrete defects, although more improvements and optimization could be done to better define internal defects.

36 MATERIALS SCIENCE↗

Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs

Purpose: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). Methods: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. Results: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two calibration methods. With wavelet analysis, defective pixels and inter-subpanel flat-fielding artifacts were clearly identified as spikes after thresholding the inversely transformed images. Conclusions: The proposed local NPS (r-square values) showed superior sensitivity to the noise level variations of individual subpanels compared with global quantitative metrics such as MTF, NPS, and DQE. Wavelet analysis was effective in detecting isolated defective pixels and inter-subpanel flat-fielding artifacts. The proposed methods are promising for the early detection of imaging artifacts of EPIDs.

60 APPLIED LIFE SCIENCES↗

CoCrMo cellular structures made by Electron Beam Melting studied by local tomography and finite element modelling

The work focuses on the structural and mechanical characterization of Co-Cr-Mo cellular samples with cubic pore structure made by Electron Beam Melting (EBM). X-ray tomography was used to characterize the architecture of the sample. High resolution images were also obtained thanks to local tomography in which the specimen is placed close to the X-ray source. These images enabled to observe some defects due to the fabrication process: small pores in the solid phase, partially melted particles attached to the surface. Then, in situ compression tests were performed in the tomograph. The images of the deformed sample show a progressive buckling of the vertical struts leading to final fracture. The deformation initiated where the defects were present in the strut i.e. in regions with reduced local thickness. The finite element modelling confirmed the high stress concentrations of these weak points leading to the fracture of the sample. - Highlights: • CoCrMo samples fabricated by Electron Beam Melting (EBM) process are considered. • X-ray Computed Tomography is used to observe the structure of the sample. • The mechanical properties are tested thanks to an in situ test in the tomograph. • A finite element model is developed to model the mechanical behaviour.

36 MATERIALS SCIENCE↗

3-D advanced gas-cooled nuclear reactor fuel channel reconstruction using structure-from-motion - 110

During planned, periodic outages, a selection of fuel channels within the UK fleet of Advanced Gas-cooled Reactor (AGR) cores are inspected using specialist tools which record video footage and other sensory data for each channel which undergoes inspection. Current visualization techniques comprise of manually produced montages by inspection engineers of points of interest (i.e. structural defects) and 2-D panoramic images of the fuel channels automatically produced using bespoke image stitching software. Both techniques however provide limited structural information due to the loss of depth data as a result of the image formation process. By recovering the depth information from the footage, a 3D model could be constructed and subsequently, allow for more accurate profiling of specific defects observed during inspection in addition to obtaining the fuel channels structure using existing footage. This work explores the preliminary application of a 3-D visualization technique known as Structure-from-Motion (SfM) which aims to obtain 3-D information by exploiting image correspondences across multiple viewpoints of the same scene in the RVI footage. This paper investigates the difficulties of applying state-of-the-art SfM to RVI footage and we present new techniques to improve feature correspondence searching in repetitive, nondescript environments. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evolution of lattice defects upon Bi-doping of epitaxial Si overlayers on Si(1 0 0)

Single Bi dopants in Si exhibit promising properties for quantum information science. Here we study, as a function of Bi-doped Si film thickness, the evolution and ultimate removal of lattice defects that are associated with a recently demonstrated viable route to precisely incorporate Bi dopants in homoepitaxial Si thin films. Scanning tunneling microscopy imaging reveals how the elongated defect structures in the Si lattice, originating from prefabricated Bi nanolines on the substrate surface that are the source of the Bi dopants, evolve with increasing Si overlayer thickness. Moreover, we demonstrate that a prolonged low-temperature annealing is able to annihilate these defect structures while leaving a significant Bi dopant concentration in the Si films.

36 MATERIALS SCIENCE↗

Archive of AGR-5/6/7 Particle Radiographs for Identification of Particles with Defective IPyC

As a part of fuel quality control characterization, 2D radiographs of large numbers of particles produced by the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program’s AGR-5/6/7 irradiation were acquired. These radiographs were used for the identification of particles with excessive uranium dispersion from the kernel into the surrounding buffer layer caused by chlorine infiltration through a defective inner pyrolytic carbon (IPyC) layer during silicon carbide (SiC) deposition. Additional features of interest associated with fabrication anomalies were also catalogued. Raw radiography images, along with the noted defective IPyC defects found by analysis at Oak Ridge National Laboratory are reported herein.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis‐Related Nanoscale Defects in Mo‐Based Janus Monolayers Revealed by Cross‐Correlated AFM and TERS Imaging

2D Janus transition metal dichalcogenides (TMDs) are promising candidates for various applications including non-linear optics, energy harvesting, and catalysis. These materials are usually synthesized via chemical conversion of pristine TMDs. Nanometer-scale characterization of the obtained Janus materials’ morphology and local composition is crucial for both the synthesis optimization and the future device applications. In this work, we present the results of cross-correlated atomic force microscopy (AFM) and tip-enhanced Raman spectroscopy (TERS) study of Janus monolayers synthesized by the hydrogen plasma-assisted chemical conversion of MoSe 2 and MoS 2 . We demonstrate that the choice of both the growth substrate and the starting TMD influences the residual strain, thereby shaping the nanoscale morphology of the resulting Janus material. Furthermore, by employing TERS imaging, we show the presence of nanoscale islands (≈20 nm across) of MoSe 2 - ${\mathrm{Mo}}_{{\mathrm{Se}}}^{\mathrm{S}}$ (MoS 2 -${\mathrm{Mo}}_{\mathrm{S}}^{{\mathrm{Se}}}$) vertical heterostructures originating from the bilayer nanoislands in the precursor monolayer crystals. The understanding of the origins of nanoscale defects in Janus TMDs revealed in this study can help with further optimization of the Janus conversion process towards uniform and wrinkle-/crack-free Janus materials. Moreover, this work shows that cross-correlated AFM and TERS imaging is a powerful and accessible method for studying nanoscale composition and defects in Janus TMD monolayers.

2D materials↗

Investigation of Backscatter X-ray imaging techniques for Uranium Dioxide Fuel Rods

Radiography by Selective Detection (RSD), was investigated for its ability to determine the presence and types of defects in a UO{sub 2} fuel rod surrounded by zirconium cladding. Images created using a Monte Carlo model compared favorably with actual X-ray backscatter images from mock fuel rods. A fuel rod was modeled as a rectangular parallelepiped with zirconium cladding, and pencil beam X-ray sources of 160 kVp (79 keV avg) and 480 kVp (218 keV avg) were generated using the Monte Carlo N-Particle Transport Code to attempt to image void and palladium (Pd) defects in the interior and on the surface of the fuel pellet. It was found that the 160 kVp spectrum was unable to detect the presence of interior defects, whereas the 480 kVp spectrum detected them with both the standard and the RSD backscatter methods, though the RSD method was very inefficient. It was also found that both energy spectra were able to detect void and Pd defects on the surface using both imaging methods. Additionally, two mock fuel rods were imaged using a backscatter X-ray imaging system, one consisting of hafnium pellets in a Zircaloy-4 cladding and the other consisting of steel pellets in a Zircalloy-4 cladding which was then encased in a steel cladding (a double encapsulation configuration employed in irradiation and experiments). It was found that the system was capable of detecting individual HfO{sub 2} pellets in a Zircaloy-4 cladding and may be capable of detecting individual steel pellets in the double-encapsulated sample. It is expected that the system would also be capable of detecting individual UO{sub 2} pellets in a Zircaloy-4 cladding, though no UO{sub 2} fuel rod was available for imaging.

36 MATERIALS SCIENCE↗

Thermographic inspection of pipes, tanks, and containment liners

Nuclear power plants are required to operate at a high level of safety. Recent industry and license renewal commitments aim to further increase safety by requiring the inspection of components that have not traditionally undergone detailed inspected in the past, such as tanks and liners. NEI 09-14 requires the inspection of buried pipes and tanks while containment liner inspections are required as a part of license renewal commitments. Containment liner inspections must inspect the carbon steel liner for defects - such as corrosion - that could threaten the pressure boundary and ideally, should be able to inspect the surrounding concrete for foreign material that could be in contact with the steel liner and potentially initiate corrosion. Such an inspection requires a simultaneous evaluation of two materials with very different material properties. Rapid, yet detailed, inspection results are required due to the massive size of the tanks and containment liners to be inspected. For this reason, thermal NDE methods were evaluated to inspect tank and containment liner mockups with simulated defects. Thermographic Signal Reconstruction (TSR) was utilized to enhance the images and provide detailed information on the sizes and shapes of the observed defects. The results show that thermographic inspection is highly sensitive to the defects of interest and is capable of rapidly inspecting large areas.

42 ENGINEERING↗

Computational scanning tunneling microscope image database

We introduce the systematic database of scanning tunneling microscope (STM) images obtained using density functional theory (DFT) for two-dimensional (2D) materials, calculated using the Tersoff-Hamann method. It currently contains data for 716 exfoliable 2D materials. Examples of the five possible Bravais lattice types for 2D materials and their Fourier-transforms are discussed. All the computational STM images generated in this work are made available on the JARVIS-STM website ( https://jarvis.nist.gov/jarvisstm ). We find excellent qualitative agreement between the computational and experimental STM images for selected materials. As a first example application of this database, we train a convolution neural network model to identify the Bravais lattice from the STM images. We believe the model can aid high-throughput experimental data analysis. These computational STM images can directly aid the identification of phases, analyzing defects and lattice-distortions in experimental STM images, as well as be incorporated in the autonomous experiment workflows.

47 OTHER INSTRUMENTATION↗

Bridging multimodal microscopy for advanced characterization on nuclear fuel using machine learning

Uranium dioxide (UO 2 ), widely used as driver fuel in light water reactors, experiences microstructure and property change by nuclear fission reactions. This paper bridges the characterization of fresh UO 2 fuel at different length scales, serving as a baseline for future post irradiation examination of irradiated UO 2 fuel. To characterize the microstructural change of nuclear fuel, modern approaches cover a wide range of length scales through different characterization techniques, such as mm scale for Synchrotron-based X-ray computed tomography (SXCT) and microscale for focused ion beam (FIB) and scanning electron microscopy (SEM). It is challenging to bridge the data and knowledge of the same sample in different length scales. This paper proposed a deep learning framework leveraging transfer learning to detect microstructural defects, trained from a sparse FIB, SEM, and SXCT images. The proposed model achieved superior performance in defect segmentation on multiscale microscopic data compared to four of the latest deep learning models.

36 MATERIALS SCIENCE↗

Topological Defects Coupling Smectic Modulations to Intra–Unit-Cell Nematicity in Cuprates

We study the coexisting smectic modulations and intra-unit-cell nematicity in the pseudogap states of underdoped Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}}. By visualizing their spatial components separately, we identified 2{pi} topological defects throughout the phase-fluctuating smectic states. Imaging the locations of large numbers of these topological defects simultaneously with the fluctuations in the intra-unit-cell nematicity revealed strong empirical evidence for a coupling between them. From these observations, we propose a Ginzburg-Landau functional describing this coupling and demonstrate how it can explain the coexistence of the smectic and intra-unit-cell broken symmetries and also correctly predict their interplay at the atomic scale. This theoretical perspective can lead to unraveling the complexities of the phase diagram of cuprate high-critical-temperature superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessment of cardiac single-photon emission computed tomography performance using a scanning linear observer

Purpose: Single-photon emission computed tomography (SPECT) is widely used to detect myocardial ischemia and myocardial infarction. It is important to assess and compare different SPECT system designs in order to achieve the highest detectability of cardiac defects. Methods: Whitaker et al.'s study ['Estimating random signal parameters from noisy images with nuisance parameters: linear and scanning-linear methods,' Opt. Express 16(11), 8150-8173 (2008)] on the scanning linear observer (SLO) shows that the SLO can be used to estimate the location and size of signals. One major advantage of the SLO is that it can be used with projection data rather than with reconstruction data. Thus, this observer model assesses the overall hardware performance independent of any reconstruction algorithm. In addition, the computation time of image quality studies is significantly reduced. In this study, three systems based on the design of the GE cadmium zinc telluride-based dedicated cardiac SPECT camera Discovery 530c were assessed. This design, which is officially named the Alcyone Technology: Discovery NM 530c, was commercialized in August, 2009. The three systems, GE27, GE19, and GE13, contain 27, 19, and 13 detectors, respectively. Clinically, a human heart can be virtually segmented into three coronary artery territories: the left-anterior descending artery, left-circumflex artery, and right coronary artery. One of the most important functions of a cardiac SPECT system is to produce images from which a radiologist can accurately predict in which territory the defect exists [http://www.asnc.org/media/PDFs/PPReporting081511.pdf, Guideline from American Society of Nuclear Cardiology]. A good estimation of the extent of the defect from the projection images is also very helpful for determining the seriousness of the myocardial ischemia. In this study, both the location and extent of defects were estimated by the SLO, and the system performance was assessed by localization receiver operating characteristic (LROC) [P. Khurd and G. Gindi, 'Decision strategies maximizing the area under the LROC curve,' Proc. SPIE 5749, 150-161 (2005)] or estimation receiver operating characteristic (EROC) [E. Clarkson, 'Estimation receiver operating characteristic curve and ideal observers for combined detection/estimation tasks,' J. Opt. Soc. Am. A 24, B91-B98 (2007)] curves. Results: The area under the LROC/EROC curve (AULC/AUEC) and the true positive fraction (TPF) at a specific false positive fraction (FPF) can be treated as the figures of merit. For radii estimation with a 1 mm tolerance, the AUEC values of the GE27, GE19, and GE13 systems are 0.8545, 0.8488, and 0.8329, and the TPF at FPF = 5% are 77.1%, 76.46%, and 73.55%, respectively. The assessment of all three systems revealed that the GE19 system yields estimated information and cardiac defect detectability very close to those of the GE27 system while using eight fewer detectors. Thus, 30% of the expensive detector units can be removed with confidence. Conclusions: As the results show, a combination of the SLO and LROC/EROC curves can determine the configuration that yields the most relevant estimation/detection information. Thus, this is a useful method for assessing cardiac SPECT systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗