Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector R&D”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Pushing the Dark-Matter Limit: The LUX-Zeplin (LZ) Experiment (Final Report)

This report highlights the accomplishments of the dark-matter group of the University of Rochester during the project period. During the grant period, all of our responsibilities for LUX were completed. Several papers describing the results of LUX analyses carried out by the Rochester group were published. The success of the Rochester trigger electronics, developed for LUX, resulted in it being selected to provide the digital platform for LZ. The PI is leading an excellent team of engineers, scientists, and students to provide the signal processing electronics, the control and monitoring system for the LZ detector, and the online computing infrastructure to process the LZ data and transfer them to the US Data Center at NERSC. During the grant period most of the R&D and prototyping of the LZ electronics was completed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detector Instrumentation, Energy Reconstruction and Data Analysis in the DUNE and NOvA Neutrino Experiments

Neutrino oscillations are so far the only experimental observation beyond the standard model since its development four decades ago. The remaining fundamental questions that can be answered by long-baseline neutrino oscillations are (1) the CP violation (whether neutrinos and antineutrinos behave the same way in oscillation), and (2) the mass hierarchy ($m_3>m_{1,2}$ or $m_{1,2}>m_3$), and (3) the octant of $\theta_{23}$ ($\theta_{23}>45^\circ, =45^\circ$ or $<45^\circ$). The PI's group at UCI focuses on long-baseline neutrino experiments DUNE and NOvA, key components of DOE's Intensity Frontier program. NOvA is the current major U.S.-based long-baseline neutrino experiment aiming to solve the mass hierarchy and $\theta_{23}$ octant. It is taking $\nu$ and $\bar{\nu}$ data from the NuMI beam at Fermilab. DUNE is the next-generation flagship neutrino experiment in the U.S. which is designed to decisively determine neutrino CP violation, mass hierarchy and $\theta_{23}$ octant. DUNE is Fermilab's first priority, and has been established as an international collaboration. During the period covered by the report, the PI's group has been exceptionally productive, with leading contributions to DUNE argon-purity monitoring detectors, NOvA/DUNE deep-learning reconstruction, and NOvA oscillation and near detector (ND) analyses. The group also is actively involved in DUNE/NOvA detector operation, data production, calibration, software upgrade and maintenance, and ProtoDUNE cold electronic QA/QC. Specifically, we have made accomplishments in the following four research projects: 1) Purity monitor R\&D and data analysis for DUNE, 2) Deep-learning-based energy reconstruction at NOvA and DUNE, 3) Oscillation analysis at NOvA, and 4) $\nu$-e elastic scattering analysis at NOvA.

47 OTHER INSTRUMENTATION↗

Electronics for Fast Timing

Picosecond-level timing will be an important component of the next generation of particle physics detectors. The ability to add a 4$^{th}$ dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments. Detectors are described in detail on other whitepapers. In this note, we address challenges in electronics design for the new generations of fast timing detectors

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for “far detectors” of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the High Rigidity Spectrometer at FRIB

A High Rigidity Spectrometer (HRS) has been designed for experiments at the Facility for Rare-Isotope Beams (FRIB) at Michigan State University (MSU). The HRS will allow experiments to be performed with the most exotic neutron-rich isotopes at high beam energies (≳100 MeV/u). The HRS consists of an analysis beamline called the High-Transmission Beamline (HTBL) and the spectrometer proper called the Spectrometer Section. Here, the maximum magnetic rigidity of the HRS is 8 Tm, which corresponds to the rigidities at which rare-isotope beams are optimally produced at FRIB. The resolving power, angular acceptance, and momentum acceptance are set to match the anticipated scientific program. An ion-optical design developed for the HRS is described in detail, along with the specifications of the associated magnet and detector systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of Carbon, Hydrogen, Nitrogen, and Oxygen in Bio-Oils: Laboratory Analytical Procedure (LAP)

The determination of total carbon, hydrogen, and nitrogen in bio-oils is important as these values can be used to track the carbon balance of production processes as well as calculate total oxygen content by difference. Oxygen content of bio-oils is a key metric for production and upgrading strategies as these are typically aimed at reducing oxygen. Oxygenates in bio-oils contribute to poor hydrocarbon miscibility, high acidity, high viscosity, and poor stability. Upgrading of bio-oils via deoxygenation produces hydrocarbons which can be used to generate feedstocks for renewable fuels and chemicals. In this Laboratory Analytical Procedure (LAP), combustion-based ultimate analysis is used to determine the weight percent (wt%) of C, H, and N in bio-oils and upgraded products. Ultimate analysis uses high temperatures and a pure oxygen environment to completely combust organic samples to carbon dioxide (CO 2 ), water (H 2 O), and nitrogen oxides (NO x ). In this procedure the amount of C and H in the sample are quantified by measuring resultant CO 2 and H 2 O with Fourier-transform infrared spectroscopy (FTIR). For N, NO x is reduced to nitrogen (N 2 ) which is measured with a thermal conductivity detector (TCD), providing total N content.

09 BIOMASS FUELS↗

A gamma ray monitor for the OSO-7 spacecraft

A 3 in. x 3 in. NaI(Tl) gamma ray (0.3 to 10 MeV) spectrometer with a CsI(Na) charged particle and anti-Compton shield has been developed for the Orbiting Solar Observatory (OSO-7) which was launched September 30, 1971. The instrument, designed for a rotating wheel compartment, utilizes a 377 channel quadratic PHA with accumulation times of 3, 1, or 0.5 minutes. Quick look and calibration data obtained via a direct data link to a minicomputer allows near real time monitoring and control of the experiment. Various commands changing the operating mode can be executed. The functions which can be commanded include: rotation of the quadrants in which data is collected by 90 deg; gain adjustment of the central detector over a 6:1 range; manual or automatic sequencing of calibrations; variations of accumulation times by telemetering selected channels; and selection of reference directions. A small X-ray detector covering the range 7.5 to 120 keV is also included.

Higbie, P. R.↗

Energetic ion mass spectrometer

A new type of spectrometer for space application has been developed to measure separately mass/charge and the three-dimensional velocity distribution of incident ions. The instrument has relatively high resolution and allows rapid measurement of the four-dimensional set of mass/charge, speed, elevation angle, and azimuth angle. The instrument includes a sector magnet, an electrostatic deflector, microchannel plate detectors with position sensitive readout, and a set of grids with variable applied voltage.

Neugebauer, M.↗

Investigation of Radiometric Properties of LANDSAT-4 MSS

Two full frames of radiometrically corrected (Type A) LANDSAT-4 MSS data were analyzed digitally and visually for evidence of residual calibration differences between detectors, quantization effects, and other sensor-related artifacts. Both standard statistical and Fourier analysis techniques were employed. Opportunities for coincident coverage by LANDSAT 3 and 4 were identified in the contiguous 48 states. Paired acquisitions for two scenes were obtained and analyzed to establish relatonships between signal values from common areas imaged by the MSS systems. Another pair with coverage by LANDSAT 2 and 4 was obtained and analyzed. Detector-to-detector differences, coherent noise, line length variation, and LANDSAT 4 to LANDSAT 3 calibration are discussed.

Rice, D. R.↗

A mercuric iodide detector system for X-ray astronomy. I - Design considerations and predictions of background and sensitivity

Since the discovery of Sco X-1 initiated X-ray astronomy in 1962, this science has progressed in connection with the placement of X-ray photon detectors above the atmosphere by means of rockets, balloons, and satellites. In the last few years, studies have been conducted regarding the use of mercuric iodide (HgI2) as room temperature X-ray detector for applications in hard X-ray astronomy. These detectors combine a high quantum efficiency with good energy resolution. The sensitivity of an astronomical X-ray telescope is discussed, and a description is presented of a specific design accepted for the HDXT to be flown on Spacelab. Attention is given to predictions of the background counting rate of the detector assembly in this design, taking into account the results of a Monte Carlo simulation of the detector assembly in the radiation environment at balloon altitudes (40 km).

Ricker, G. R.↗

Spectral slicing X-ray telescope

Layered synthetic microstructure (LSM) X-ray optics is investigated as a system for coupling a conventional glancing incidence X-ray mirror to a high sensitivity X-ray detector. It is shown that, by the use of figured LSM optics, it is possible to magnify the X-ray image produced by the primary mirrors so as to maintain their high inherent spatial resolution. The results of theoretical and design analyses of several spectral slicing X-ray telescope systems that utilize LSM mirrors of hyperboloidal, spherical, ellipsoidal, and constant optical path aspheric configurations are presented. It is shown that the spherical LSM optics are the preferred configuration, yielding subarcsecond performance over the entire field. The Stanford/Marshall Space Flight Center Rocket X-ray Telescope, which will utilize normal incidence LSM optics to couple a Wolter-Schwarzschild primary mirror to high resolution detectors for solar X-ray/EUV studies, is discussed. Design diagrams are included.

Hoover, R. B.↗

Self-structured, current aperture approach for bubble memory

An approach to magnetic bubble memory which incorporates dual conductor current access drive with a self-structured (strongly interacting) bubble lattice is described. This is expected to provide higher operating speeds, defect tolerance, and higher bit density for a given bubble size as compared to present field access bubble devices. Bubble spacings of 2.5 bubble diameters are projected for a prototype device. Experimental work on device components including detectors, major/minor loops, and gates is described. Defect tolerance has also been demonstrated.

Nelson, G. L.↗

Performance of the FOS Detectors in a Variable External Magnetic Field

We present the results of an investigation of the in-orbit performance of the Digicon detectors in the Faint Object Spectrograph (FOS), conducted as part of the commissioning phase of the Hubble Space Telescope. This paper includes orbital results on detector background noise, sensor image stability, and photometric stability along with several typical FOS observations. New techniques for suppressing cosmic ray induced background and geomagnetic induced image motion in electron tube detectors are also discussed.

Fitch, J. E.↗

High-energy neutron spectroscopy with thick silicon detectors

The high-energy neutron component of the space radiation environment in thick structures such as the International Space Station contributes to the total radiation dose received by an astronaut. Detector design constraints such as size and mass have limited the energy range of neutron spectrum measurements in orbit to about 12 MeV in Space Shuttle studies. We present a new method for high-energy neutron spectroscopy using small silicon detectors that can extend these measurements to more than 500 MeV. The methodology is based on measurement of the detector response function for high-energy neutrons and inversion of this response function with measured deposition data to deduce neutron energy spectra. We also present the results of an initial shielding study performed with the thick silicon detector system for high-energy neutrons incident on polyethylene.

Non-NASA Center↗

Thin Film Thermal Conductivity Measurements using Superconducting Nanowires

We present a simple experimental scheme for estimating the cryogenic thermal transport properties of thin films using superconducting nanowires. In a parallel array of nanowires, the heat from one nanowire in the normal state changes the local temperature around adjacent nanowires, reducing their switching current. Calibration of this change in switching current as a function of bath temperature provides an estimate of the temperature as a function of displacement from the heater. This provides a method of determining the contribution of substrate heat transport to the cooling time of superconducting nanowire single photon detectors. Understanding this process is necessary for successful electrothermal modeling of superconducting nanowire systems.

Shaw, M. D.↗