Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Elemental Composition of 433 Eros: New Calibration of the NEAR-Shoemaker XRS Data

We present relative elemental abundances for six elements (Mg, Al, Si, S, Ca, Fe) in the surface layer of 433 Eros, derived from a new analysis of the solar induced fluorescence measured by the NEARShoemaker X ray Spectrometer (XRS).XRS derived elemental abundances have been presented before. However, calibration of XRS data depends critically on knowledge of the incident solar spectrum, which varies greatly on time scales of seconds to minutes. Unfortunately, the gas solar monitor carried by NEAR was inadequately calibrated prior to launch. The previously published XRS results were based partly on broadband measurements by the Earthorbiting GOES8 (Geostationary Operational Environmental Satellites) Xray detectors and partly on a preliminary solar monitor calibration carried out by the present authors. The new solar monitor calibration is based on a more recent set of physical models of the solar spectrum at various temperatures, an improved fitting procedure, analysis of a large number of flight spectra, and comparison with concurrent data from the GOES Xray detectors. In addition, the new analysis includes data from three solar flares not considered in earlier papers.

Lim, L. F.↗

L-Band Transmit/Receive Module for Phase-Stable Array Antennas

Interferometric synthetic aperture radar (InSAR) has been shown to provide very sensitive measurements of surface deformation and displacement on the order of 1 cm. Future systematic measurements of surface deformation will require this capability over very large areas (300 km) from space. To achieve these required accuracies, these spaceborne sensors must exhibit low temporal decorrelation and be temporally stable systems. An L-band (24-cmwavelength) InSAR instrument using an electronically steerable radar antenna is suited to meet these needs. In order to achieve the 1-cm displacement accuracy, the phased array antenna requires phase-stable transmit/receive (T/R) modules. The T/R module operates at L-band (1.24 GHz) and has less than 1- deg absolute phase stability and less than 0.1-dB absolute amplitude stability over temperature. The T/R module is also high power (30 W) and power efficient (60-percent overall efficiency). The design is currently implemented using discrete components and surface mount technology. The basic T/R module architecture is augmented with a calibration loop to compensate for temperature variations, component variations, and path loss variations as a function of beam settings. The calibration circuit consists of an amplitude and phase detector, and other control circuitry, to compare the measured gain and phase to a reference signal and uses this signal to control a precision analog phase shifter and analog attenuator. An architecture was developed to allow for the module to be bidirectional, to operate in both transmit and receive mode. The architecture also includes a power detector used to maintain a transmitter power output constant within 0.1 dB. The use of a simple, stable, low-cost, and high-accuracy gain and phase detector made by Analog Devices (AD8302), combined with a very-high efficiency T/R module, is novel. While a self-calibrating T/R module capability has been sought for years, a practical and cost-effective solution has never been demonstrated. By adding the calibration loop to an existing high-efficiency T/R module, there is a demonstrated order-of-magnitude improvement in the amplitude and phase stability.

Andricos, Constantine↗

OP09O-OP404-9 Wide Field Camera 3 CCD Quantum Efficiency Hysteresis

The HST/Wide Field Camera (WFC) 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. At the nominal operating temperature of -83C, the QEH feature contrast was typically 0.1-0.2% or less. The behavior was replicated using flight spare detectors. A visible light flat-field (540nm) with a several times full-well signal level can pin the detectors at both optical (600nm) and near-UV (230nm) wavelengths, suppressing the QEH behavior. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. The HST/Wide Field Camera 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. The first observed manifestation of QEH was the presence in a small percentage of flat-field images of a bowtie-shaped contrast that spanned the width of each chip. At the nominal operating temperature of -83C, the contrast observed for this feature was typically 0.1-0.2% or less, though at warmer temperatures contrasts up to 5% (at -50C) have been observed. The bowtie morphology was replicated using flight spare detectors in tests at the GSFC Detector Characterization Laboratory by power cycling the detector while cold. Continued investigation revealed that a clearly-related global QE suppression at the approximately 5% level can be produced by cooling the detector in the dark; subsequent flat-field exposures at a constant illumination show asymptotically increasing response. This QE "pinning" can be achieved with a single high signal flat-field or a series of lower signal flats; a visible light (500-580nm) flat-field with a signal level of several hundred thousand electrons per pixel is sufficient for QE pinning at both optical (600nm) and near-UV (230nm) wavelengths. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. A preliminary estimate of the decay timescale for one detector is that a drop of 0.1-0.2% occurs over a ten day period, indicating that relatively infrequent cal lamp exposures can mitigate the behavior to extremely low levels.

Collins, Nick↗

Implementation of Leak Test Methods for the International Space Station (ISS) Elements, Systems and Components

The International Space Station (ISS has Qualification and Acceptance Environmental Test Requirements document, SSP 41172 that includes many environmental tests such as Thermal vacuum & Cycling, Depress/Repress, Sinusoidal, Random, and Acoustic Vibration, Pyro Shock, Acceleration, Humidity, Pressure, Electromatic Interference (EMI)/Electromagnetic Compatibility (EMCO), etc. This document also includes (13) leak test methods for Pressure Integrity Verification of the ISS Elements, Systems, and Components. These leak test methods are well known, however, the test procedure for specific leak test method shall be written and implemented paying attention to the important procedural steps/details that, if omitted or deviated, could impact the quality of the final product and affect the crew safety. Such procedural steps/details for different methods include, but not limited to: - Sequence of testing, f or example, pressurization and submersion steps for Method I (Immersion); - Stabilization of the mass spectrometer leak detector outputs fo r Method II (vacuum Chamber or Bell jar); - Proper data processing an d taking a conservative approach while making predictions for on-orbit leakage rate for Method III(Pressure Change); - Proper Calibration o f the mass spectrometer leak detector for all the tracer gas (mostly Helium) Methods such as Method V (Detector Probe), Method VI (Hood), Method VII (Tracer Probe), Method VIII(Accumulation); - Usage of visibl ility aides for Method I (Immersion), Method IV (Chemical Indicator), Method XII (Foam/Liquid Application), and Method XIII (Hydrostatic/Visual Inspection); While some methods could be used for the total leaka ge (either internal-to-external or external-to-internal) rate requirement verification (Vacuum Chamber, Pressure Decay, Hood, Accumulation), other methods shall be used only as a pass/fail test for individual joints (e.g., welds, fittings, and plugs) or for troubleshooting purposes (Chemical Indicator, Detector Probe, Tracer Probe, Local Vacuum Chamber, Foam/Liquid Application, and Hydrostatic/Visual Inspection). Any isolation of SSP 41172 requirements have led to either retesting of hardware or accepting a risk associated with the potential system or component pressure integrity problem during flight.

Underwood, Steve↗

Assessment of MODIS and VIIRS Solar Diffuser On-Orbit Degradation

Both MODIS and VIIRS instruments use a solar diffuser (SD) for their reflective solar bands (RSB) on-orbit calibration. On-orbit changes in SD bi-directional reflectance factor (BRF) are tracked by a solar diffuser stability monitor (SDSM) using its alternate measurements of the sunlight reflected off the SD panel and direct sunlight through a fixed attenuation screen. The SDSM calibration data are collected by a number of filtered detectors, covering wavelengths from 0.41 to 0.94 micrometers. In this paper we describe briefly the Terra and Aqua MODIS and S-NPP VIIRS SDSM on-orbit operation and calibration activities and strategies, provide an overall assessment of their SDSM on-orbit performance, including wavelength-dependent changes in the SDSM detector responses and changes in their SD BRF, and discuss remaining challenging issues and their potential impact on RSB calibration quality. Due to different launch dates, operating configurations, and calibration frequencies, the Terra and Aqua MODIS and S-NPP VIIRS SD have experienced different amount of SD degradation. However, in general the shorter the wavelength, the larger is the SD on-orbit degradation. On the other hand, the larger changes in SDSM detector responses are observed at longer wavelengths in the near infrared (NIR).

MODIS↗

Measurement and Calibration of PSD with Phase-shifting Interferometers

We discuss the instrumental aspects affecting the measurement accuracy when determining PSD with phase shifting interferometers. These include the source coherence, optical train effects, and detector effects. The use of a carefully constructed calibration standard will also be discussed. We will end with a recommended measurement and data handling procedure.

Lehan, J. P.↗

Static diffusion cloud chambers

The chamber geometry and optical arrangement are described. The supersaturation range is given and consists of readings taken at five fixed points: 0.25%, 0.5%, 0.75%, 1.0%, and 1.25%. The detection system is described including light source, cameras, and photocell detectors. The temperature control and the calibration of the chamber are discussed.

Ayers, G.↗

Simulation of electronic registration of multispectral remote sensing images to 0.1 pixel accuracy

Band-to-band coregistration of multispectral remote sensing images can be achieved by electronic signal processing techniques rather than by costly and difficult mechanical alignment. This paper describes the results of a study of the end-to-end performance of electronic registration. The software simulation includes steps which model the performance of the geometric calibration process, the instrument image quality, detector performance and the effects of achieving coregistration through image resampling. The image resampling step emulates the Pipelined Resampling Processor, a real-time image resampler. The study demonstrates that the electronic alignment technique produces multispectral images which are superior to those produced by an imager whose pixel geometry is accurate to 0.1 pixel rms. The implications of this approach for future earth observation programs are discussed.

Reitsema, H. J.↗

Measurements of hydrogen and helium isotopes in Galactic cosmic rays from 1978 through 1984

The propagation of light cosmic rays is examined using measurements of the relative abundances of the isotopes H-1, H-2 and He-3 and He-4 made with the ISEE 3 instrumentation. It is believed that cosmic ray particles experience spallation in traveling through the interstellar medium, thereby producing the isotopes examined in the present study. The isotopic ratios are therefore expected to yield data on outward migrating particles, which lose energy while moving toward extragalactic space, i.e., the 'leaky box approximation'. The energy ranges covered are 26-138 MeV/nucleon for H-1 and He-4, 24-89 MeV/nucleon for H-2 and 43-146 MeV/nucleon for He-3. Solar activity ranged from minimum to maximum over the observational period. Details of the experimental strategies, instrumentation features and calibration techniques employed with the particle detectors are provided. Histograms were geneated of the energies attributable to each particle track and mass ratios of the various isotopes were calculated over the measured energy ranges. Account was taken of errors introduced by solar modulation, and an escape path length of 5.6-7.8 g/sq cm was estimated for particle propagation through the Galaxy. The projected path length agrees with previous estimates based on data from heavier cosmic ray nuclei.

Kroeger, R.↗

Expected scientific performance of the three spectrometers on the extreme ultraviolet explorer

The expected in-orbit performance of the three spectrometers included on the Extreme Ultraviolet Explorer astronomical satellite is presented. Recent calibrations of the gratings, mirrors and detectors using monochromatic and continuum EUV light sources allow the calculation of the spectral resolution and throughput of the instrument. An effective area range of 0.2 to 2.8 sq cm is achieved over the wavelength range 70-600 A with a peak spectral resolution (FWHM) of 360 assuming a spacecraft pointing knowledge of 10 arc seconds (FWHM). For a 40,000 sec observation, the average 3 sigma sensitivity to a monochromatic line source is 0.003 photons/sq cm s. Simulated observations of known classes of EUV sources, such as hot white dwarfs, and cataclysmic variables are also presented.

Vallerga, J. V.↗

Goddard high resolution spectrograph science verification and data analysis

The data analysis performed was to support the Orbital Verification (OV) and Science Verification (SV) of the GHRS was in the areas of the Digicon detector's performance and stability, wavelength calibration, and geomagnetic induced image motion. The results of the analyses are briefly described. Detailed results are given in the form of attachments. Specialized software was developed for the analyses. Calibration files were formatted according to the specifications in a Space Telescope Science report. IRAS images were restored of the Large Magellanic Cloud using a blocked iterative algorithm. The algorithm works with the raw data scans without regridding or interpolating the data on an equally spaced image grid.

Source record↗

Summary of Terra and Aqua MODIS On-orbit Calibration and Characterization Results

The Moderate Resolution Imaging Spectroradiometer (MODIS) onboard NASA's EOS Terra spacecraft has been in operation for more than seven years since its launch in December 1999 and the MODIS onboard Aqua spacecraft has been in operation for more than 4.5 years since its launch in May 2002. Compared to its heritage sensors, such as AVHRR, CZCS, SeaWiFS, HIRS, and Landsat TM, the MODIS instrument was developed with improved spectral and spatial resolutions, and temporal scale or global coverage frequency. The two MODIS instruments are nearly identical with each collecting data in 36 spectral bands: 20 reflective solar bands (RSB) with center wavelengths from 0.41 to 2.2jm and 16 thermal emissive bands (TEB) from 3.7 to 4.4 microns. MODIS makes the Earth view observations with a scan angle range of +/-55 degree relative to instrument nadir and at three nadir spatial resolutions: 0.25km for bands 1-2.05km for bands 3-7, and 1km for bands 8-36, thus enabling complete global coverage of the Earth in less than 2 days. Both Terra and Aqua MODIS observations have been routinely used to generate a broad range of science data products that are widely distributed and extensively applied for the studies of the Earth's land, oceans, and atmosphere and for the monitoring of climate and environmental changes. It is obvious that the MODIS science data product quality strongly relies on sensor on-orbit performance and its capability of continuously tracking sensor response changes over time. Because of this, each MODIS was built with a comprehensive set of on-board calibrators (OBC) that include a solar diffuser (SD) for the RSB calibration, a blackbody (BB) for the TEB calibration, and a spectro-radiometric calibration assembly (SRCA) for the spatial (RSB and TEB) and spectral (RSB only) characterization. Most importantly, extensive and dedicated sensor calibration and characterization efforts have been constantly made by the MODIS Characterization Support Team (MCST) at NASA/GSFC. In this presentation, we will provide an overview of MODIS sensor operations since 1aunh and the onorbit calibration and characterization methodologies with emphasis on the differences between Terra and Aqua MODIS characteristics. We will summarize both Terra and Aqua MODIS onorbit calibration and characterization results, including their RSB and TEB detector noise characterization, the sensor response changes, and the corrections to the optics degradation. In addition to radiometric calibration performance, we will illustrate both sensors' spectral and spatial characterization results in terms of their band-to-band registrations and spectral band center wavelength shifts.

Xiong, X.↗

Transforming Our Understanding of the X-ray Universe: The Imaging X-ray Polarimeter Explorer (IXPE)

Accurate X-ray polarimetry can provide unique information on high-energy-astrophysical processes and sources. As there have been no meaningful X-ray polarization measurements of cosmic sources since our pioneering work in the 1970's, the time is ripe to explore this new parameter space in X-ray astronomy. To accomplish this requires a well-calibrated and well understood system that-particularly for an Explorer mission-has technical, cost, and schedule credibility. The system that we shall present satisfies these conditions, being based upon completely calibrated imaging- and polarization-sensitive detectors and proven X-ray-telescope technology.

Weisskopf, Martin C.↗

In-flight Absolute Radiometric Calibration of the Thematic Mapper

The Thematic Mapper (TM) multispectral scanner system was placed into Earth orbit on July 16, 1982, as part of NASA's LANDSAT 4 payload. To determine temporal changes of the absolute radiometric calibration of the entire system in flight, spectroradiometric measurements of the ground and the atmosphere are made simultaneously with TM image acquisitions over the White Sands, New Mexico area. By entering the measured values into an atmospheric radiative transfer program, the radiance levels at the entrance pupil of the TM in four of the TM spectral bands are determined. These levels are compared to the output digital counts from the detectors that sampled the radiometrically measured ground area, thus providing an absolute radiometric calibration of the entire TM system utilizing those detectors. By reference to an adjacent, larger uniform area, the calibration is extended to all 16 detectors in each of the three bands.

Castle, K. R.↗

Impacts of Cross-Platform Vicarious Calibration on the Deep Blue Aerosol Retrievals for Moderate Resolution Imaging Spectroradiometer Aboard Terra

The retrieval of aerosol properties from spaceborne sensors requires highly accurate and precise radiometric measurements, thus placing stringent requirements on sensor calibration and characterization. For the Terra/Moderate Resolution Imaging Spedroradiometer (MODIS), the characteristics of the detectors of certain bands, particularly band 8 [(B8); 412 nm], have changed significantly over time, leading to increased calibration uncertainty. In this paper, we explore a possibility of utilizing a cross-calibration method developed for characterizing the Terral MODIS detectors in the ocean bands by the National Aeronautics and Space Administration Ocean Biology Processing Group to improve aerosol retrieval over bright land surfaces. We found that the Terra/MODIS B8 reflectance corrected using the cross calibration method resulted in significant improvements for the retrieved aerosol optical thickness when compared with that from the Multi-angle Imaging Spectroradiometer, Aqua/MODIS, and the Aerosol Robotic Network. The method reported in this paper is implemented for the operational processing of the Terra/MODIS Deep Blue aerosol products.

Jeong, Myeong-Jae↗

Space radiation studies

Instrument design and data analysis expertise was provided in support of several space radiation monitoring programs. The Verification of Flight Instrumentation (VFI) program at NASA included both the Active Radiation Detector (ARD) and the Nuclear Radiation Monitor (NRM). Design, partial fabrication, calibration and partial data analysis capability to the ARD program was provided, as well as detector head design and fabrication, software development and partial data analysis capability to the NRM program. The ARD flew on Spacelab-1 in 1983, performed flawlessly and was returned to MSFC after flight with unchanged calibration factors. The NRM, flown on Spacelab-2 in 1985, also performed without fault, not only recording the ambient gamma ray background on the Spacelab, but also recording radiation events of astrophysical significance.

Gregory, J. C.↗

Central Stars of Planetary Nebulae in the LMC

In FUSE cycle 2's program B001 we studied Central Stars of Planetary Nebulae (CSPN) in the Large Magellanic Could. All FUSE observations have been successfully completed and have been reduced, analyzed and published. The analysis and the results are summarized below. The FUSE data were reduced using the latest available version of the FUSE calibration pipeline (CALFUSE v2.2.2). The flux of these LMC post-AGB objects is at the threshold of FUSE's sensitivity, and thus special care in the background subtraction was needed during the reduction. Because of their faintness, the targets required many orbit-long exposures, each of which typically had low (target) count-rates. Each calibrated extracted sequence was checked for unacceptable count-rate variations (a sign of detector drift), misplaced extraction windows, and other anomalies. All the good calibrated exposures were combined using FUSE pipeline routines. The default FUSE pipeline attempts to model the background measured off-target and subtracts it from the target spectrum. We found that, for these faint objects, the background appeared to be over-estimated by this method, particularly at shorter wavelengths (i.e., < 1000 A). We therefore tried two other reductions. In the first method, subtraction of the measured background is turned off and and the background is taken to be the model scattered-light scaled by the exposure time. In the second one, the first few steps of the pipeline were run on the individual exposures (correcting for effects unique to each exposure such as Doppler shift, grating motions, etc). Then the photon lists from the individual exposures were combined, and the remaining steps of the pipeline run on the combined file. Thus, more total counts for both the target and background allowed for a better extraction.

Bianchi, Luciana↗