Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Calibration of the DUNE Far Detector Using Cosmic-ray Muon Events

The Deep Underground Neutrino Experiment (DUNE) aims to set new limits on parameters associated with neutrino oscillations, neutrino astrophysics, and beyond the Standard Model (SM) searches such as nucleon decay. DUNE will quantify the magnitude of CP violation in the lepton sector, and determine the neutrino mass ordering. These benefit highly from the large target mass and excellent imaging, tracking, and particle identification capabilities of Liquid Argon Time Projection Chambers (LArTPCs). Detector calibration is essential to make precise physics measurements. For instance, accurate energy reconstruction is necessary for measuring many of the aforementioned quantities with the precision required for discovering new physics and fully exploiting the capabilities of the detector. Cosmic muons are a freely available natural source of calorimetric data and can be used for calibrating various detector parameters. This thesis provides an analysis of simulated cosmic-ray muon events generated with the Muon Simulation Underground (MUSUN) generator in the DUNE horizontal drift (HD) far detector (FD). The study focuses on analysing the energy and angular distribution of various classes of muon events, as well as characterising the different particles produced by cosmic muon interactions. The analysis of π0 → 2γ events within the cosmic-ray muon sample is presented in this thesis with a detailed study of reconstructing electromagnetic showers. The π0 mass is reconstructed within the DUNE FD, yielding a value of (136 ± 7) MeV/c2. Additionally, the thesis introduces methods for dE/dx calibration using simulated and reconstructed muon tracks. A calibration constant Ccal = (5.469 ± 0.003) × 10−3 ADC × tick/e is obtained through a model-dependent calibration process, where 1 tick corresponds to 500 ns of sampling time of an ADC. Furthermore, a calibration technique is presented, demonstrating precise translation from dQ/dx to dE/dx. This calibration method is applied to stopping muons, charged pions, and protons in the DUNE FD, addressing the measurement of energy loss in the detector volume. These are important calibrations of the DUNE FD and will contribute to achieving the exciting physics goals of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Spontaneous Fission Neutron Emission Energy on Neutron Detector Response

A parametric study was simulated in MCNP to investigate the impact of spontaneous fission neutron energy on neutron detector response. A total of 880 configurations were simulated by varying 3 He pressure and polyethylene reflector thickness for 8 different isotopes. Results showed that deviations between the simulated isotopes become more prevalent at higher energies with 238 U showing the greatest deviation. It was also observed that configurations comparable to most detection setups, 10 atm and 6 - 8 cm polyethylene, were closer to the upper bound of deviations from a 252 Cf. 240 Pu, a common spontaneous fission source of interest, ranged from 2% - 3% within this space. This suggests that further investigation is required to determine exact correction factors when calibrating neutron detectors with a 252 Cf. Although demonstrated here for a 4π-detection system, future plans include simulating a more detailed model of the MC-15 detection setup to determine exact correction factors for future experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Let’s get our hands dirty: a comprehensive evaluation of DAQDB, key-value store for petascale hot storage

Data acquisition systems are a key component for successful data taking in any experiment. The DAQ is a complex distributed computing system and coordinates all operations, from the data selection stage of interesting events to storage elements. For the High Luminosity upgrade of the Large Hadron Collider, the experiments at CERN need to meet challenging requirements to record data with a much higher occupancy in the detectors. The DAQ system will receive and deliver data with a significantly increased trigger rate, one million events per second, and capacity, terabytes of data per second. An effective way to meet these requirements is to decouple real-time data acquisition from event selection. Data fragments can be temporarily stored in a large distributed key-value store. Fragments belonging to the same event can be then queried on demand, by the data selection processes. Implementing such a model relies on a proper combination of emerging technologies, such as persistent memory, NVMe SSDs, scalable networking, and data structures, as well as high performance, scalable software. In this paper, we present DAQDB (Data Acquisition Database) — an open source implementation of this design that was presented earlier, with an extensive evaluation of this approach, from the single node to the distributed performance. Furthermore, we complement our study with a description of the challenges faced and the lessons learned while integrating DAQDB with the existing software framework of the ATLAS experiment.

Abed Abud, Adam↗

Accelerated 133 Xe Quantification in Samples Containing Significant 133 mXe

The quantification of 133 Xe in the presence of its mother radionuclide 133 mXe requires the full quantification of both to perform the ingrowth correction for 133 Xe. Due to the nature of both of these radionuclides, the 133 mXe requires significantly more time to quantify by High Purity Germanium (HPGe) detectors due to lower production yields, lower gamma emission probabilities, and lower detection efficiencies. This work shows that 133 Xe and 133 mXe quantification can be accelerated by measuring the 133m:133 activity ratio for a large batch of material and applying this activity ratio to assays of lower activity subsamples of the same batch of material. Included in this report are derivations of the required decay correction equations, and experiments using actual samples to validate the performance of these equations. A detector calibration method is also shown that leverages this method as an alternative to existing calibration methods for 133 mXe quantification.

133mXe↗

Electromagnetic calorimeters based on scintillating lead tungstate crystals for experiments at Jefferson Lab

A new electromagnetic calorimeter consisting of 140 lead tungstate (PbWO 4 ) scintillating crystals was constructed for the PrimEx- &#x3B7; experiment at Jefferson lab. The calorimeter was integrated into the data acquisition and trigger systems of the GlueX detector and used in the experiment to reconstruct Compton scattering events. The experiment started collecting data in the spring of 2019 and acquired about 30% of the required statistics. The calorimeter is a prototype for two PbWO 4 -based detectors: the Neutral Particle Spectrometer (NPS) and the lead tungstate insert of the Forward CALorimeter (FCAL) of the GlueX detector. The article presents the design and performance of the Compton calorimeter and gives a brief overview of the FCAL and NPS projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Directional detection of dark matter with diamond

Searches for weakly interacting massive particle (WIMP) dark matter will in the near future be sensitive to solar neutrinos. Directional detection offers a method to reject solar neutrinos and improve WIMP searches, but reaching that sensitivity with existing directional detectors poses challenges. We propose a combined atomic/particle physics approach using a large-volume diamond detector. WIMP candidate events trigger a particle detector, after which spectroscopy of nitrogen vacancy (NV) centers reads out the direction of the incoming particle. Here we discuss the current state of technologies required to realize directional detection in diamond and present a path towards a detector with sensitivity below the neutrino floor.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics Opportunities in the Far-forward Region at the Future Electron–Ion Collider

The Electron–Ion Collider provides the opportunity to drastically advance our understanding of QCD and the multidimensional structure of both protons and nuclei. An essential component of the EIC physics program is the identification and characterization of exclusive, diffractive, and tagged events using detectors integrated with the outgoing hadron beamline, the so-called “far-forward” detectors. The ePIC experiment includes a suite of far-forward detectors designed to deliver the necessary geometric coverage and resolution required to achieve the exclusive physics program envisioned at the EIC. Additionally, to the multidimensional imaging program at the EIC, topics such as spectator tagging in e + d and e + 3 He reactions to access structure functions and searches for gluon saturation in e + A collisions are also enabled by this experimental apparatus. In these proceedings, the ePIC far-forward detectors will be briefly introduced, and a few selected physics topics focused on tagged deep-inelastic scattering will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Splitting phonons: Building a platform for linear mechanical quantum computing

Linear optical quantum computing provides a desirable approach to quantum computing, with only a short list of required computational elements. The similarity between photons and phonons points to the interesting potential for linear mechanical quantum computing using phonons in place of photons. Although single-phonon sources and detectors have been demonstrated, a phononic beam splitter element remains an outstanding requirement. Here we demonstrate such an element, using two superconducting qubits to fully characterize a beam splitter with single phonons. We further use the beam splitter to demonstrate two-phonon interference, a requirement for two-qubit gates in linear computing. In conclusion, this advances a new solid-state system for implementing linear quantum computing, further providing straightforward conversion between itinerant phonons and superconducting qubits.

97 MATHEMATICS AND COMPUTING↗

Characterization of UV optical components for photon detector calibration in liquid argon TPCs

Large liquid argon time projection chambers (LArTPCs)require stable and well-characterized delivery of ultraviolet (UV)light for in situ calibration of photosensors at cryogenictemperatures. This article reports bench-top and cryogenicmeasurements of the optical components used in a UV lightcalibration system, including multi-mode fused-silica fibers,SMA-to-SMA connectors, optical fiber feedthroughs, andlight-diffuser assemblies. Light loss in several fiber types and SMAconnectors was measured across wavelengths from275–970 mm. In addition,light-loss measurements of the tested fibers after severalliquid-nitrogen thermal cycles showed no statistically significantdegradation relative to baseline measurements, and high-rate pulsedexposure (30–90 million pulses from a275 nm LED) likewise showed nomeasurable aging in jacketed fibers. A compact, palm-sized,3D-printed PEEK diffuser housing with stacked UV-grade fused-silicadiffusers yields Lambertian emission and the most uniform angulardistribution. Optical components exhibiting improved UV transmissionwere deployed successfully in multiple DUNE small- and large-scaleprototypes, demonstrating reliable operation of UV light calibrationsystem. These findings inform component selection and calibrationprocedures for achieving reliable, uniform UV light delivery inlarge-scale cryogenic detectors such as DUNE.

Behera, B. [South Dakota Sch. Mines Tech.] (ORCID:↗

Charge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD

DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.

Front-end electronics for detector readout↗

Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.

Cryogenic detectors↗

End-to-End Modeling of the TDM Readout System for CMB-S4

The CMB-S4 experiment is developing next-generation ground-based microwave telescopes to observe the cosmic microwave background with unprecedented sensitivity. This will require an order of magnitude increase in the 100-mK detector count, which, in turn, increases the demands on the readout system. The CMB-S4 readout will use time-division multiplexing (TDM), taking advantage of faster switches and amplifiers in order to achieve an increased multiplexing factor. To facilitate the design of the new readout system, we have developed a model that predicts the bandwidth and noise performance of this circuitry and its interconnections. This is then used to set requirements on individual components in order to meet the performance necessary for the full system. Here, we present an overview of this model and compare the model results to the performance of both legacy and prototype readout hardware.

47 OTHER INSTRUMENTATION↗

MPGD Trackers in the ePIC Detector at the EIC

The future Electron-Ion Collider (EIC) at Brookhaven National Laboratory will collide polarized electrons with polarized proton/ions. The electron ? Proton / Ion Collider (ePIC) Experiment is the EIC general-purpose detector aiming at delivering the full physics program of the EIC. This unique environment imposes stringent requirements on the tracking system needed for the measurement of the scattered electron and charged particles produced in the collisions at the EIC. The central tracker of the ePIC detector has silicon layers for tracking and vertexing based on MAPS technology, which are complemented by large Micro-Pattern Gaseous Detector (MPGD) trackers in the barrel and in both the electron and hadron end cap regions. The MPGD layers provide fast timing (10-20 ns) and additional hit points (150 µm) for pattern recognition during track finding. Two MPGD technologies are used in ePIC central trackers: cylindrical Micromegas for the barrel inner tracker and planar thin-gap GEM-µRWELL hybrid detector for the barrel outer tracker and the end cap disks. In this talk, we will introduce these two technologies in the context of ePIC and we will discuss the ongoing R&D efforts to address the requirements. Finally, we will discuss the plans and timeline for the production and testing and commissioning of the MPGD trackers for the installation in the ePIC detector.

Gnanvo, Kondo↗

Demonstration of a 1820 channel multiplexer for transition-edge sensor bolometers

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology, which combines their signals over a reduced number of wires and amplifiers. Here, in this Letter, we present and demonstrate a multiplexer design optimized for transition-edge sensor bolometers with 1820 sensors per readout unit, a factor of two more than the previous state-of-the-art. The design is optimized for cosmic microwave background imaging applications, and it builds on previous microwave superconducting quantum interference device multiplexers by doubling the available readout bandwidth to the full 4–8 GHz octave. Evaluating the key performance metrics of yield, sensitivity, and crosstalk through laboratory testing, we find an end-to-end operable detector yield of 78%, a typical nearest-neighbor crosstalk amplitude of ∼0.4%, and a median white noise level of 83 pA/$\sqrt{\textrm{Hz}}$ due to the multiplexer, corresponding to an estimated contribution of 4% to the total system noise for a ground-based cosmic microwave background telescope. Additionally, we identify a possible path toward reducing resonator loss for future designs with reduced noise. We expect these developments to alleviate the system complexity, cryogenic requirements, and cost of future large arrays of low temperature detectors.

cosmic microwave background↗

CACTUS: A depleted monolithic active timing sensor using a CMOS radiation hard technology

The planned luminosity increase at the Large Hadron Collider in the coming years has triggered interest in the use of the particles' time of arrival as additional information in specialized detectors to mitigate the impact of pile-up. The required time resolution is of the order of tens of picoseconds, with a spatial granularity of the order of 1 mm. A time measurement at this precision level will also be of interest beyond the LHC and beyond high energy particle physics. We present in this paper the first developments towards a radiation hard Depleted Monolithic Active Pixel Sensor (DMAPS), with high-resolution time measurement capability. The technology chosen is a standard high voltage CMOS process, in conjunction with a high resistivity detector material, which has already proven to efficiently detect particles in tracking applications after several hundred of Mrad of irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dilepton Program with Time-of-Flight Detector at the STAR Experiment

Pairs of lepton and antilepton (dilepton) in a continuous mass range are one of the most experimentally challenging and golden probes of the quark-gluon plasma (QGP) produced in heavy ion collisions because they do not strongly interact with the hot and dense medium, and reflect the properties of the medium at the time the dilepton is generated. The measurements of dileptons require lepton identification with high purity and high efficiency at large detector acceptance. STAR is one of two large experiments at the relativistic heavy ion collider with a primary goal of searching for the QGP and studying its properties. The STAR experiment launched a comprehensive dielectron (e + e - ) program enabled by the time-of-flight (TOF) detector that had been fully installed in 2010. In this article, we review the decade-long R&D, the construction and performance of the STAR TOF detector, and dielectron measurements, including thermal dielectron production and dielectron production from the Breit–Wheeler process. Future perspectives are also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation-hard miniature optical engine with high bandwidth

Future silicon trackers will be operated in an intense radiation environment and require large volumes of data to be transmitted off detector. In addition, the optical modules must be of low mass in order to limit multiple scattering and nuclear interactions that would degrade the overall performance of the detector. Here, we present a miniature optical engine that satisfies these constraints. The optical engine consists of an ASIC driving a VCSEL (Vertical Cavity Surface Emitting Laser) array in an optical package. Two ASICs are designed to operate a 12-channel VCSEL array at 1.28 or 5.12 Gb/s per channel, which yields a total data rate of up to 60 Gb/s. The core transistors are fabricated in a 65 nm CMOS process which enhance the radiation-hardness. Each channel contains equalizer (CTLE) and clock-data recovery circuits (CDR) so that the ASIC can restore the highly distorted electrical signal after propagating through several meters of cables of small diameter. The equalizer, CDR, and VCSEL driver are configured via a digital I 2 C chip interface with triple redundant memory to mitigate single event upset (SEU) effects. The bias and modulation currents are controlled by a digital-to-analog converter (DAC). We present the design of the circuit together with the results of the simulations and preliminary measurements.

47 OTHER INSTRUMENTATION↗