Search NASA⌕ Search

SEARCH · Search NASA

Results for “difference frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Influence of frequency on the structure of zirconium oxide coatings deposited from aqueous electrolytes under microplasma oxidation

The work describes the microplasma oxidation (MPO) of zirconium surface resulting in the formation of zirconium oxide Zr-Al-Nb-O. We have used novel power supply to deposit oxide ceramic coatings by MPO and studied the effect of current density on the phase structure of oxide ceramic coatings. The size of microcracks in the coatings was determined at different frequencies. We have also used EVO50c scanning election microscope with an attachment for elemental analysis to study the morphology and elemental composition of oxide ceramic coating. In addition, we have established the influence of the frequency on the phase composition of the coating: at the frequency of 2500 Hz, the fraction of monoclinic phase was 18%, while the fraction of tetragonal phase amounted to 72%. The oxide ceramic coating produced at 250 Hz contained 38% of monoclinic phase and 62% of tetragonal phase; in addition, it had no buildups and craters.

36 MATERIALS SCIENCE↗

Probabilistic Assessment of Damage from Same Shock Response Spectra due to Variations in Damping

Interpretation of field data from shock tests and subsequent assessment of product safety margins via laboratory testing are based on the shock response spectra (SRS). The SRS capture how a single degree of freedom (SDOF) structure responds to the shock at differing frequencies and, therefore, no longer contain the duration or other temporal parameters pertaining to the shock. A single duration can often be included in the technical specification or in the recreation of acceleration vs. time history from the specified SRS; however, there is little basis for that beyond technical judgment. The loss of such temporal information can result in the recreated SRS being the same while its effect on a system or component can be different. This paper attempts to quantify this deficiency as well as propose a simple method of capturing damping from shock waves that can allow the original waveform to be more accurately reconstructed from the SRS. In this study the decay rate associated with various frequencies that comprise the overall shock was varied. This variation in the decay rate leads to a variation in the acceleration vs. time history, which can be correlated to a “Damage Index” that captures the fatigue damage imparted to the object under shock. Several waveforms that have the same SRS but varying rates of decay for either high- or low-frequency components of the shock were investigated. The resulting variation in stress cycles and Damage Index is discussed in the context of the lognormal distribution of fatigue failure data. It is proposed that, along with the SRS, the decay rate is also captured to minimize the discrepancy between field data and representative laboratory tests.

36 MATERIALS SCIENCE↗

Fault Clearing Operation in Low-Frequency High-Voltage AC Systems

Abstract—Low-frequency high-voltage ac (LF-HVac) system has been proposed as an alternative to HVdc and HVac systems to reduce transmission losses and improve grid flexibility. LF-HVac system employs back-to-back (BTB) converters to interconnect and control the voltage and power interchange between two power grid operating at different frequencies. While there are multiple studies on LF-HVac system in the literature, the fault clearing method in the LF-HVac system has not been analyzed. Therefore, this paper focuses on fault clearing operation in LFHVac system and proposes a novel method to reduce fault current by changing operating frequency of power source and converter. The performance of the proposed method is validated using detailed models of BTB converters developed in PSCAD/EMTDC. The ability to change operating frequency at the onset of a fault condition allows breakers to rapidly clear the fault and recloses. The results obtained by using the proposed method substantially diminish the fault current.

Kim, Woosung↗

PFLOTRAN-SIP: A PFLOTRAN Module for Simulating Spectral-Induced Polarization of Electrical Impedance Data

Spectral induced polarization (SIP) is a non-intrusive geophysical method that collects chargeability information (the ability of a material to retain charge) in the time domain or its phase shift in the frequency domain. Although SIP is a temporal method, it cannot measure the dynamics of flow and solute/species transport in the subsurface over long times (i.e., 10–100 s of years). Data collected with the SIP technique need to be coupled with fluid flow and reactive-transport models in order to capture long-term dynamics. To address this challenge, PFLOTRAN-SIP was built to couple SIP data to fluid flow and solute transport processes. Specifically, this framework couples the subsurface flow and transport simulator PFLOTRAN and geoelectrical simulator E4D without sacrificing computational performance. PFLOTRAN solves the coupled flow and solute-transport process models in order to estimate solute concentrations, which were used in Archie’s model to compute bulk electrical conductivities at near-zero frequency. These bulk electrical conductivities were modified while using the Cole–Cole model to account for frequency dependence. Using the estimated frequency-dependent bulk conductivities, E4D simulated the real and complex electrical potential signals for selected frequencies for SIP. These frequency-dependent bulk conductivities contain information that is relevant to geochemical changes in the system. This study demonstrated that the PFLOTRAN-SIP framework is able to detect the presence of a tracer in the subsurface. SIP offers a significant benefit over ERT in the form of greater information content. It provided multiple datasets at different frequencies that better constrained the tracer distribution in the subsurface. Consequently, this framework allows for practitioners of environmental hydrogeophysics and biogeophysics to monitor the subsurface with improved resolution.

54 ENVIRONMENTAL SCIENCES↗

Transrectal Array Configurations Optimized For Prostate HIFU Ablation

The objectives of this study were to evaluate and compare steering and ablation rates from several types of transrectal arrays operated at different frequencies for whole prostate ablation. Three-dimensional acoustic and thermal modeling (Rayleigh-Sommerfield and Penne's BHTE) were performed. Treatment volumes up to 70cc and anterior-posterior distances up to 6 cm were considered. The maximum transducer dimensions were constrained to 5 cm (along rectum) and 2.5 cm (elevation), and the channel count was limited to 256. Planar array configurations for truncated-annular, 1/1.5D, and 2D random arrays were evaluated at 1, 2, and 4 MHz for capability to treat the entire prostate. The acoustic intensity at the surface was fixed at 10 W/cm{sup 2}. The maximum temperature was restricted to 80 deg. C. The volumetric ablation rate was computed to compare the treatment times amongst different configurations. The 1.5D Planar array at 1 MHz ablated the whole prostate in the shortest amount of time while maintaining adequate steering. The higher frequency arrays required smaller elevation apertures for a fixed channel count to maintain a single focal spot at the desired location. Consequently, these arrays resulted in slower heating rates with increased near-field heating. The 1 MHz 1.5D array would also be advantageous compared to single-element transducers since only one mechanical degree of motion is required. This study demonstrates the selection of an optimal array geometry and frequency for transrectal HIFU, resulting in faster ablation rates and reduced treatment times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Orientational atom interferometers sensitive to gravitational waves

We present an atom interferometer that differs from common atom interferometers as it is not based on the spatial splitting of electronic wave functions, but on orienting atoms in space. As an example we present how an orientational atom interferometer based on highly charged hydrogen-like atoms is affected by gravitational waves. We show that a monochromatic gravitational wave will cause a frequency shift that scales with the binding energy of the system rather than with its physical dimension. For a gravitational wave amplitude of h=10{sup -23} the frequency shift is of the order of 110 {mu}Hz for an atom interferometer based on a 91-fold charged uranium ion. A frequency difference of this size can be resolved by current atom interferometers in 1 s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual-frequency terahertz emission from splitting filaments induced by lens tilting in air

Dual-frequency terahertz radiation from air-plasma filaments produced with two-color lasers in air has been demonstrated experimentally. When a focusing lens is tilted for a few degrees, it is shown that the laser filament evolves from a single one to two sub-filaments. Two independent terahertz sources emitted from the sub-filaments with different frequencies and polarizations are identified, where the frequency of terahertz waves from the trailing sub-filament is higher than that from the leading sub-filament.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Absorption Properties of Supercooled Liquid Water between 31 and 225 GHz: Evaluation of Absorption Models Using Ground-Based Observations

Microwave radiometers (MWR) are commonly used to quantify the amount of supercooled liquid water (SLW) in clouds; however, the accuracy of the SLW retrievals is limited by the poor knowledge of the SLW dielectric properties at microwave frequencies. Six liquid water permittivity models were compared with ground-based MWR observations between 31 and 225 GHz from sites in Greenland, the German Alps, and a low-mountain site; average cloud temperatures of observed thin cloud layers range from 0° to –33°C. A recently published method to derive ratios of liquid water opacity from different frequencies was employed in this analysis. These ratios are independent of liquid water path and equal to the ratio of αL at those frequencies that can be directly compared with the permittivity model predictions. The observed opacity ratios from all sites show highly consistent results that are generally within the range of model predictions; however, none of the models are able to approximate the observations over the entire frequency and temperature range. Findings in earlier published studies were used to select one specific model as a reference model for αL at 90 GHz; together with the observed opacity ratios, the temperature dependence of αL at 31.4, 52.28, 150, and 225 GHz was derived. The results reveal that two models fit the opacity ratio data better than the other four models, with one of the two models fitting the data better for frequencies below 90 GHz and the other for higher frequencies. Furthermore, these findings are relevant for SLW retrievals and radiative transfer in the 31–225-GHz frequency region.

54 ENVIRONMENTAL SCIENCES↗

Lifetime-Limited Interrogation of Two Independent 27 Al + Clocks Using Correlation Spectroscopy

Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the 1 S 0 ↔ 3 P 0 transition in 27 Al + . By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of 1.12 × 10 15 Hz. Here, the observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s 3 P 0 state lifetime and represents a measurement instability of (1.8 ± 0.5) × 10 –16 /√τ/s for averaging periods longer than the probe duration when dead time is negligible.

74 ATOMIC AND MOLECULAR PHYSICS↗

Synthesis and characterization of a new layered organic-inorganic hybrid nickel(II) 1,4:5,8-naphthalenediimide bis-phosphonate, exhibiting canted antiferromagnetism, with T{sub c}{approx}21 K

A new Ni(II) layered hybrid organic-inorganic compound of formula Ni{sub 2}[(NDI-BP)(H{sub 2}O){sub 2}].2H{sub 2}O has been prepared in very mild conditions from N,N'-bis(2-phosphonoethyl)napthalene-1,4:5,8-tetracarboximide (NDI-BP ligand) and NiCl{sub 2}. The X-ray powder structure characterization of the title compound suggests a pillared layered organic-inorganic hybrid structure. The distance between the organic and inorganic layers has been found to be 17.8 A. The inorganic layers consist of corner sharing [NiO{sub 5}(H{sub 2}O)] octahedra and they are pillared by the diphosphonate groups. DC and AC magnetic measurements as a function of temperature and field indicate the presence of 2D antiferromagnetic exchange interactions between the nearest-neighbor Ni(II) ions below 100 K. A long-range magnetic ordering at T{sub c}{approx}21 K has been established and is attributed to the presence of spin canting. AC magnetic measurements as a function of temperature at different frequencies confirm the occurrence of the magnetic ordering temperature at T=21 K and the presence of a slight structural disorder in the title compound. - Graphical abstract: A new layered hybrid organic-inorganic Ni(II) N,N'-bis(2-phosphonoethyl)-naphthalene 1,4:5,8 tetracarboxydiimide complex has been synthesized and characterized. Magnetic measurements as a function of temperature and at different fields show that the compound is magnetically ordered below T{sub c}{approx}21 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spin Unrestricted Nonradiative Relaxation Dynamics of Cobalt-Doped Anatase Nanowire

Spin-resolved charge transfer dynamics at the interface of a Co(NH3)2-doped (001) anatase TiO2 nanowire and liquid water calculations based on density functional theory and density matrix formalism are considered. Three models with the same stoichiometry but different electronic structure are explored. While one model had no change to electron count and spin count (neutral model), the other two models were assigned a charge of 2+, one in a doublet and the other a quartet spin configuration. Co2+ is the most probable state for dopant in all models and Co acts as an electron acceptor. The optical absorption spectra show a rather unique pattern post 400 nm where the α and β absorptions happen independently at different frequency ranges. Essentially, the relaxation dynamics can be controlled as when an α electron is excited, there is a near zero probability of a β electron also undergoing an excitation and vice versa. The isolated exemption is between 400 and 650 nm in the neutral model. All the models absorb light in the visible range, while the electrons and holes have drastic differences in relaxation rates. The spatial charge separation occurs upon excitation and subsequent trapping, designating the considered system a prospect for electrochemical cell applications. (2+) models trap states more effectively slow down electron relaxation, making the charged models slightly better options for application compared to the neutral model.

Jensen, Stephanie J.↗

Superradiant amplification of terahertz radiation by plasmons in inverted graphene with a planar distributed Bragg resonator

It is shown theoretically that stimulated generation of terahertz radiation by plasmons in graphene with a planar distributed Bragg resonator is possible at two different frequencies for each plasmon mode. This behavior may be attributed to the superradiance of the collective plasmon mode, which is associated with superlinear increase in the radiative damping of the plasmons with increase in pumping power. As a result, the curves of the radiative damping and the plasmon gain as a function of the pumping power intersect at two points corresponding to different generation conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Triply-resonant sum frequency conversion with gallium phosphide ring resonators

We demonstrate quasi-phase matched, triply-resonant sum frequency conversion in 10.6-µm-diameter integrated gallium phosphide ring resonators. A small-signal, waveguide-to-waveguide power conversion efficiency of 8 ± 1.1%/mW; is measured for conversion from telecom (1536 nm) and near infrared (1117 nm) to visible (647 nm) wavelengths with an absolute power conversion efficiency of 6.3 ± 0.6%; measured at saturation pump power. For the complementary difference frequency generation process, a single photon conversion efficiency of 7.2%/mW from visible to telecom is projected for resonators with optimized coupling. Efficient conversion from visible to telecom will facilitate long-distance transmission of spin-entangled photons from solid-state emitters such as the diamond NV center, allowing long-distance entanglement for quantum networks.

42 ENGINEERING↗

Amplitude Variability in gamma Dor and delta Sct Stars Observed by Kepler

The NASA Kepler spacecraft data revealed a large number of new multimode nonradially pulsating gamma Dor and delta Sct variable stars. The Kepler high-precision long time-series photometry makes it possible to study amplitude variations of the frequencies, and recent literature on amplitude and frequency variations in nonradially pulsating variables is summarized. Several methods are applied to study amplitude variability in about a dozen gamma Doradus or delta Scuti candidate variable stars observed for several quarters as part of the Kepler Guest Observer program. The magnitude and timescale of the amplitude variations are discussed, along with the presence or absence of correlations between amplitude variations for different frequencies of a given star. Proposed causes of amplitude spectrum variability that will require further investigation are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Tunable Inductive Coupler for High-Fidelity Gates Between Fluxonium Qubits

The fluxonium qubit is a promising candidate for quantum computation due to its long coherence times and large anharmonicity. We present a tunable coupler that realizes strong inductive coupling between two heavy-fluxonium qubits, each with approximately 50-MHz frequencies and approximately 5-GHz anharmonicities. The coupler enables the qubits to have a large tuning range of 𝑋⁢𝑋 coupling strengths (−35 to 75 MHz). The 𝑍⁢𝑍 coupling strength is <3 kHz across the entire coupler bias range and <100 Hz at the coupler off position. These qualities lead to fast high-fidelity single- and two-qubit gates. By driving at the difference frequency of the two qubits, we realize a $\sqrt{i\textrm{SWAP}}$ gate in 258 ns with fidelity 99.72%, and by driving at the sum frequency of the two qubits, we achieve a $\sqrt{𝑏⁢\textrm{SWAP}}$ gate in 102 ns with fidelity 99.91%. This latter gate is only five qubit Larmor periods in length. We run cross-entropy benchmarking for over 20 consecutive hours and measure stable gate fidelities, with $\sqrt{𝑏⁢\textrm{SWAP}}$ drift (2⁢𝜎) <0.02% and $\sqrt{i\textrm{SWAP}}$ drift <0.08%.

Zhang, Helin↗

SU-F-R-38: Impact of Smoothing and Noise On Robustness of CBCT Textural Features for Prediction of Response to Radiotherapy Treatment of Head and Neck Cancers

Purpose: To examine the impact of image smoothing and noise on the robustness of textural information extracted from CBCT images for prediction of radiotherapy response for patients with head/neck (H/N) cancers. Methods: CBCT image datasets for 14 patients with H/N cancer treated with radiation (70 Gy in 35 fractions) were investigated. A deformable registration algorithm was used to fuse planning CT’s to CBCT’s. Tumor volume was automatically segmented on each CBCT image dataset. Local control at 1-year was used to classify 8 patients as responders (R), and 6 as non-responders (NR). A smoothing filter [2D Adaptive Weiner (2DAW) with 3 different windows (ψ=3, 5, and 7)], and two noise models (Poisson and Gaussian, SNR=25) were implemented, and independently applied to CBCT images. Twenty-two textural features, describing the spatial arrangement of voxel intensities calculated from gray-level co-occurrence matrices, were extracted for all tumor volumes. Results: Relative to CBCT images without smoothing, none of 22 textural features extracted showed any significant differences when smoothing was applied (using the 2DAW with filtering parameters of ψ=3 and 5), in the responder and non-responder groups. When smoothing, 2DAW with ψ=7 was applied, one textural feature, Information Measure of Correlation, was significantly different relative to no smoothing. Only 4 features (Energy, Entropy, Homogeneity, and Maximum-Probability) were found to be statistically different between the R and NR groups (Table 1). These features remained statistically significant discriminators for R and NR groups in presence of noise and smoothing. Conclusion: This preliminary work suggests that textural classifiers for response prediction, extracted from H&N CBCT images, are robust to low-power noise and low-pass filtering. While other types of filters will alter the spatial frequencies differently, these results are promising. The current study is subject to Type II errors. A much larger cohort of patients is needed to confirm these results. This work was supported in part by a grant from Varian Medical Systems (Palo Alto, CA)

60 APPLIED LIFE SCIENCES↗

Neutron radiation effects on linear CCDs at different clock pulse frequency

The experiments of reactor neutron radiation effects on linear CCDs are presented. The output voltage in dark field after neutron radiation are presented and compared at different clock pulse frequency. The degradation phenomena are analyzed in depth. The mean dark signal (K{sub D}) and dark signal non-uniformity (DSNU) versus neutron fluence is investigated at different clock pulse frequency. The degradation mechanisms of the dark signal and DSNU in linear CCDs are analyzed. The flux of the reactor neutron beams was about 1.33 × 10{sup 8} n/cm{sup 2}/s. The samples were exposed to 1MeV neutron-equivalent fluences of 1 × 10{sup 11}, 5 × 10{sup 11}, and 1 × 10{sup 12} n/cm{sup 2}, respectively.

36 MATERIALS SCIENCE↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗