Search NASA⌕ Search

SEARCH · Search NASA

Results for “drum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Effects of eating on vection-induced motion sickness, cardiac vagal tone, and gastric myoelectric activity

This study investigated the effect of food ingestion on motion sickness severity and its physiological mechanisms. Forty-six fasted subjects were assigned either to a meal group or to a no-meal group. Electrogastrographic (EGG) indices (normal 3 cpm activity and abnormal 4-9 cpm tachyarrhythmia) and respiratory sinus arrhythmia (RSA) were measured before and after a meal and during a subsequent exposure to a rotating drum in which illusory self-motion was induced. The results indicated that food intake enhanced cardiac parasympathetic tone (RSA) and increased gastric 3 cpm activity. Postprandial effects on motion sickness severity remain equivocal due to group differences in RSA baseline levels. During drum rotation, dysrhythmic activity of the stomach (tachyarrhythmia) and vagal withdrawal were observed. Furthermore, high levels of vagal tone prior to drum rotation predicted a low incidence of motion sickness symptoms, and were associated positively with gastric 3 cpm activity and negatively with tachyarrhythmia. These data suggest that enhanced levels of parasympathetic activity can alleviate motion sickness symptoms by suppressing, in part, its dysrhythmic gastric underpinnings.

NASA Discipline Neuroscience↗

A Constant-Force Resistive Exercise Unit

A constant-force resistive exercise unit (CFREU) has been invented for use in both normal gravitational and microgravitational environments. In comparison with a typical conventional exercise machine, this CFREU weighs less and is less bulky: Whereas weight plates and associated bulky supporting structures are used to generate resistive forces in typical conventional exercise machines, they are not used in this CFREU. Instead, resistive forces are generated in this CFREU by relatively compact, lightweight mechanisms based on constant-torque springs wound on drums. Each such mechanism is contained in a module, denoted a resistive pack, that includes a shaft for making a torque connection to a cable drum. During a stroke of resistive exercise, the cable is withdrawn from the cable drum against the torque exerted by the resistance pack. The CFREU includes a housing, within which can be mounted one or more resistive pack(s). The CFREU also includes mechanisms for engaging any combination of (1) one or more resistive pack(s) and (2) one or more spring(s) within each resistive pack to obtain a desired level of resistance.

Colosky, Paul↗

Robotic Two-Wheeled Vehicle

A robotic two-wheeled vehicle comprising a connection body interposed between the two wheels are described. A drum can be coaxially located in a central region of the connection body and can support a hollow arm projecting radially from the drum. A tether can be inserted in the arm and connected to a second drum. Instruments and sensors can be accommodated in a case housed inside each wheel.

Nesnas, Issa A. D.↗

Robotic Two-Wheeled Vehicle

A robotic two-wheeled vehicle comprising a connection body interposed between the two wheels are described. A drum can be coaxially located in a central region of the connection body and can support a hollow arm projecting radially from the drum. A tether can be inserted in the arm and connected to a second drum. Instruments and sensors can be accommodated in a case housed inside each wheel.

Nesnas, Issa A. D.↗

One-step method for the production of nanofluids

A one step method and system for producing nanofluids by a nanoparticle-source evaporation and deposition of the evaporant into a base fluid. The base fluid such oil or ethylene glycol is placed in a rotating cylindrical drum having an adjustable heater-boat-evaporator and heat exchanger-cooler apparatus. As the drum rotates, a thin liquid layer is formed on the inside surface of the drum. An insulated heater-boat-evaporator having an evaporant material (nanoparticle-source) placed within its boat evaporator is adjustably positioned near a portion of the rotating thin liquid layer, the evaporant material being heated thereby evaporating a portion of the evaporant material and forming nanoparticles, the nanoparticles absorbed by the liquid film to form nanofluid.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Scientific Upgrades at the High Flux Isotope Reactor at Oak Ridge National Laboratory

The United States Department of Energy is sponsoring a number of projects that will provide scientific upgrades to the neutron science facilities associated with the high Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory. Funding for the first upgrade project was initiated in 1996 and all presently identified upgrade projects are expected to be completed by the end of 2003. The upgrade projects include: (1) larger beam tubes, (2) a new monochromator drum for the HB-1 beam line, (3) a new HB-2 beam line system that includes one thermal guide and a new monochromator drum, (4) new instruments for the HB-2 beamline, (5) a new monochromator drum for the HB-3 beam line, (6) a supercritical hydrogen cold source system to be retrofitted into the HB-4 beam tube, (7) a 3.5 kW refrigeration system at 20 K to support the cold source and a new building to house it, (8) a new HB-4 beam line system composed of four cold neutron guides with various mirror coatings and associated shielding, (9) a number of new instruments for the cold beams including two new SANS instruments, and (10) construction of support buildings. This paper provides a short summary of these projects including their present status and schedule.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scientific Upgrades at the Oak Ridge National Laboratory High Flux Isotope Reactor

The United States Department of Energy is sponsoring a number of projects that will provide scientific upgrades to the neutron science facilities associated with the High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory. Funding for the first upgrade project was initiated in 1996 and all presently identified upgrade projects are expected to be completed by the end of 2003. The upgrade projects include: (1) larger beam tubes, (2) a new monochromator drum for the HB-1 beam line, (3) a new HB-2 beam line system that includes one thermal guide and a new monochromator drum, (4) new instruments for the HB-2 beamline, (5) a new monochromator drum for the HB-3 beam line, (6) a supercritical hydrogen cold source system to be retrofitted into the HB-4 beam tube, (7) a 3.5 kW refrigeration system at 20 K to support the cold source and a new building to house it, (8) a new HB-4 beam line system composed of four cold neutron guides with various mirror coatings and associated shielding, (9) a number of new instruments for the cold beams including two new SANS instruments, and (10) construction of support buildings. This paper provides a short summary of these projects including their present status and schedule.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Handling and Treatment of Sodium-Potassium Alloy (NaK) after the Loss of Key Personnel – 19002

ABSTRACT In September 2010, during cleanup and removal efforts associated with a glovebox containing a sodium-potassium alloy (NaK) cooling system, a NaK reaction event occurred. Near the end of the evolution, which was at a Materials and Fuels Complex (MFC) research facility at the Idaho National Laboratory, a 2 to 3-ounce sample of NaK was being transferred from a metal can to a polyethylene bottle so it could be sent to the disposal outlet for verification analysis. During the transfer, a reaction of the NaK with ambient air was observed in both the metal can and sample container. The potential for a reaction was identified during the planning of this activity and mitigating steps were included in the procedures. In response, the two containers were flooded with argon, closed, and observed overnight. No additional reaction was noted. The sample container and metal can were packaged into a 10-gallon drum and transferred to a permitted storage location pending disposal. While the other containers generated from the deactivation and decommissioning activity were sent off-site for disposal, the 10-gal drum remained due to concerns by a staff specialist that the material could contain potassium superoxide (KO2) as a result of the reaction event. The intent at that time was to treat the NaK in a Resource Conservation and Recovery Act (RCRA)-permitted treatment facility at MFC, instead of sending it off-site for disposal. The container was labeled, inspected, and managed as a hazardous waste. Due to the complexities associated with safely handling and treating NaK and KO2, the container remained in storage. Treatment and disposal of the NaK and KO2 container was revisited in 2016, when researchers and chemists were consulted regarding the potential for superoxide formation and the best means to safely store and treat the container. The facility came to realize that due to the retirements of key personnel, it needed to provide current employees operational experience with the handling and treatment of NaK. An outside company was identified and contracted to provide training and consulting services. Several Battelle Energy Alliance, Inc. (BEA) personnel then attended an alkali metals safety training class. The training course provided participants with classroom and hands–on instruction associated with: • Hazards associated with handling and using sodium and NaK • Proper personal protection equipment, spill control techniques, and first aid • Common design approaches for buildings, systems, and equipment used to contain sodium and NaK • What to expect in the event of a water reaction and how to respond • How to properly prepare for a fire and contain/extinguish small metal fires • A hands-on demonstration of NaK reaction and controls. Following the training, a procedure was developed to open the container, and inspect and treat the NaK. In June 2017, facility operations personnel successfully completed the inspection and treatment of the NaK drum, eliminating the legacy liability.

99 GENERAL AND MISCELLANEOUS↗

Utilizing fly ash particles to produce low-cost metal matrix composites

Metal matrix composites (MMCs) are a blend of fine ceramic particles mixed with metals such as aluminium or magnesium. Fly ash is considerably cheaper than ceramics; aluminium-fly ash composites cost less than 60% of conventional aluminium-SiC composites making them attractive to automakers striving for lower weight and cheaper materials for brake rotors or brake drums. Ultalite.com has consulted with US researchers to to find the optimum requirements of the fly ash needed to make MMCs. Particle size 20-40 microns, low calcium oxide content and spherical particles were identified. The desired particles once extracted are stirred into molten aluminum and the resulting composite is into ingots for shipment to a casting facility. Dynamometer testing has shown that aluminium-fly ash composite brake drums have better performance and wear than cast iron drums. 6 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Diamond Shaving of Contaminated Concrete Surfaces

Decommissioning and decontamination of existing facilities presents technological challenges. One major challenge is the removal of surface contamination from concrete floors and walls while eliminating the spread of contamination and volumetric reduction of the waste stream. Numerous methods have been tried with a varying degree of success. Recent technology has made this goal achievable and has been used successfully. This new technology is the Diamond Floor Shaver and Diamond Wall shaver. The Diamond Floor Shaver is a self-propelled, walk behind machine that literally shaves the contaminated concrete surface to specified depths. This is accomplished by using a patented system of 100 dry cutting diamond blades with offset diamond segments that interlock to provide complete shaving of the concrete surface. Grooves are eliminated which allows for a direct frisk reading to analyze results. When attached to an appropriate size vacuum, the dust produced is 100% contained. Dust is collected in drums ready for disposition and disposal. The waste produced in shaving 7,500 square feet at 1/8 inch thickness would fill a single 55 gallon drum. Production is dependent on depth of shaving but averages 100 square feet per hour. The wall shaver uses the same patented diamond drum and blades but is hydraulically driven and is deployed using a robotic arm allowing its operation to be to totally remote. It can reach ceilings as high as 20 feet. Numerous small projects were successfully completed using this technology. Large scale deployment came in 2003. Bluegrass, in conjunction with Bartlett Services, deployed this technology to support decontamination activities for closing of the Rocky Flats nuclear weapons site. Up to six floor shavers and one wall shaver were deployed in buildings B371 and B374. These buildings had up to one half-inch, fixed plutonium and beryllium contamination. Hundred-thousands of square feet of floors and walls were shaved successfully to depths of up to one half inch. Decontamination efforts were so successful the balance of the buildings could be demolished using conventional methods. The shavers helped keep the project on schedule while the vacuum system eliminated the potential for contaminants becoming airborne.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Treatment Procedure for a Volume Reduction of the Spent HEPA Filters in KAERI

Spent filter wastes of about 2,200 units have been stored in the radioactive waste storage facility of the Korea Atomic Energy Research Institute since its operation. Among these spent filter wastes, a HEPA filter account for about 95 %. All these HEPA filter wastes generated at KAERI have been stored inside a poly bag in accordance with the original form without any treatment of them. Therefore, in order to secure a space in a radioactive waste storage facility approaching its saturation, it is necessary to treat them by a compaction in view of a radioactive waste treatment and storage, and finally to repack the compacted spent filters into a regular drum for sending them to a final disposal site. To do that, the spent HEPA filter wastes were classified according to their generation facility, their generation date and their surface dose rate by investigating the inventory of them. And also, a nuclide assessment of them was conducted by taking a representative sample at the spot of a high dose rate at the intake surface and the outlet surface of a spent HEPA filter without a dismantlement, before compacting them. At present, for the spent HEPA filter wastes after a radionuclide assessment, a compaction treatment of them is now being conducted by using the shaping and compacting equipment developed at KAERI. Thus, to put a HEPA filter with a hexahedral form of a 610(W) x 610(H) x 305(T) mm into a regular drum (DOT-17H) with an inner diameter of about 572 mm, a columnar shaping with a capacity of 15 tons was conducted. From this shaping, a shaped HEPA filter waste with a diameter of about 500 mm was directly put into a regular drum. And then, the compaction treatment of a shaped HEPA filter with a capacity of about 60 tons was conducted by vertically compacting it. As a result, a volume reduction rate of a spent HEPA filter waste by a shaping and compacting of it accounted for about 1/8 when compared to its original form. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Passive and Active Neutron Matrix Correction for Heterogeneous Distributions Utilizing the Neutron Imaging Technique

Classical Non-Destructive Assay (NDA) Passive Neutron Coincidence Counting (PNCC) and Differential Die-Away (DDA) active neutron interrogation techniques [1, 2] are well suited for determining the gross matrix correction factors for homogenous mass distributions of Special Nuclear Material (SNM) within an interfering waste drum matrix. These measured passive and active matrix correction factors are crucial in quantifying the SNM mass, associated Total Measurement Uncertainty (TMU), and Minimum Detectable Activity (MDA) within the drum. When heterogeneous SNM mass distributions are encountered, the measured SNM mass, TMU and MDA biases introduced may be 100%, or greater, especially for dense hydrogenous matrices. The standard matrix correction factors can be adjusted if a coarse spatial image of the SNM mass, relative to the matrix, is available. The image can then be analyzed to determine the spatially-adjusted, matrix correction factors case by case. This image analysis approach was accomplished by modifying the standard Passive-Active Neutron (PAN) counter design [3] to accommodate a unique data acquisition architecture that supports a newly developed image acquisition and analysis application called the Neutron Imaging Technique (NIT). The NIT functionality supports both PNCC and DDA acquisition and analysis modes and exploits the symmetry between a stored set of factory acquired NIT images with those from the unknown PAN assay. The NIT result is then an adjustment to the classical correction factor reducing, if not removing, the SNM mass bias and revealing the true TMU and MDA values. In this paper we describe the NIT for the PAN design from the software and algorithmic perspectives and how this technique accommodates waste matrix drums that are difficult, from the classical standpoint, if not impossible, to extract meaningful SNM mass, TMU and MDA results. (authors)

42 ENGINEERING↗

Experiences on a Regulatory Clearance of the Radioactive Wastes at KAERI

At the Korea Atomic Energy Research Institute (KAERI) in Daejeon, about 4,500 drums of old radioactive soil and concrete wastes have been stored since their generation and transport to Daejeon in 1988. The wastes have been stored for more than 18 years. So, according to the analysis result for their radioactivity, some of them can be regularly cleared. In addition to that, about 2,200 tonnes of decommissioning wastes were generated during the dismantling of Korean research reactors no.1 and no.2 (KRR-1 and KRR-2) from 1997 to 2005. Among those, only 13% were classified as radioactive wastes and part of remains were cleared. In this paper, the experiences on a regulatory clearance of radioactive wastes at KAERI were discussed. First, for the old wastes, a working procedure for representative sampling of each drum and an analysis was developed. Also, as these old wastes are already in a storage facility, some equipment and tools for easy sampling and restricting a contamination of a storage facility were developed and applied. Following the working procedure, the old wastes with a surface dose rate less than 0.3 {mu}Sv/hr were selected for an analysis. Based on the analysis results of a sample, the waste with a radioactivity concentration less than 0.4 Bq/g was classified as an object for regulatory clearance. According to the radiological dose assessment result and the dose criteria regulated by Atomic Energy Act of Korea (individual dose<10 {mu}Sv/yr, collective dose<1 man.Sv/yr), about 2,800 drums of wastes were determined for a clearance and they are under process for a license. After a clearance, it is scheduled for the wastes to be disposed of at a public dumping ground. Second, for the recently generated decommissioning wastes, the analysis for their radioactive characteristics was simpler than that for the old wastes. The distribution of a radioactivity levels, a gross alpha/beta contamination and a surface dose rate was measured to assess the radiological dose for the biological shielding concrete. According to the radiological dose assessment result, about 800 tonnes of the concrete will be disposed of conventionally by a recycling or landfill disposal after approval of the clearance plan by the regulatory authority. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Add-A-Source Matrix Calibration of a Large Neutron Box Counter

A general purpose passive neutron box counter has been designed, constructed and factory calibrated. The instrument is intended to sort and assay Transuranic Uranium (TRU) waste according to the Waste Isolation Pilot Plant (WIPP) criteria in containers ranging from drums to large boxes and crates. A multi-position Cf Add-A-Source (AAS) capability has been built into the system to determine gross matrix correction factors. The Cf source capsule runs in a U-shaped guide tube beneath the powered roller conveyor used to move the containers into the assay cavity from the loading station. The factory calibration involved measuring a wide range of matrix materials and densities in 208-liter (55 US-gal.) barrels, Standard Waste Box (SWB), Standard Large Box (SLB-2), and Ten Drum Overpack (TDOP) containers. For each container a Volume Weighted Average (VWA) rate and an AAS perturbation factor was determined and the relationship between them was established for the full range of conditions expected to be encountered operationally. In this paper we describe the calibration procedure which used Cf-252 as a surrogate for Pu-240 to map out the spatial responses for the various container-matrix combinations. A particular challenge was the scale of the measurement campaign which was directly related to the large volume of some of the containers. The reduction of the data was also challenging because for the larger items with high concentrations of hydrogen steep spatial gradients were observed in the response. For this reason simple volume-element averaging of the data to derive VWA quantities was inadequate and numerical-integration approaches of the 3-dimensional maps were explored. The response maps were also used to create point-source contributions to the Total Measurement Uncertainty (TMU), but this work is not the subject of this paper. The wide range in container size also required varying numbers of AAS interrogation position. For the drums a single AAS position was used while for the SWB and TDOP six positions were used to achieve better coverage of the cross-section. The SLB-2 has a larger cross section still and ten positions of the AAS were used for this container. The AAS calibration parameterizations for the various containers will be described along with the difficulties associated with a calibration of large containers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of Radioisotope Content by Measurement of Waste Package Dose Rates - 13394

The objective of this communication is to report the observed correlation between the calculated air kerma rates produced by radioactive waste drums containing untreated ion-exchange resin and activated charcoal slurries with the measured radiation field of each package. Air kerma rates at different distances from the drum surface were calculated with the activity concentrations previously determined by gamma spectrometry of waste samples and the estimated mass, volume and geometry of solid and liquid phases of each waste package. The water content of each waste drum varies widely between different packages. Results will allow determining the total activity of wastes and are intended to complete the previous steps taken to characterize the radioisotope content of wastes packages. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LL/ILW: Post-Qualification of Old Waste through Non-Destructive Extraction of Barrels from Cement Shields - 13535

Currently there is a large number of radioactive waste drums entombed in cement shields at German nuclear power plants. These concrete containers used in the past for the waste are not approved for the final repository. Compliance with current acceptance criteria of the final repository has to be proven by qualification measures on the waste. To meet these criteria, a new declaration and new packing is necessary. A simple non-destructive extraction of about 2000 drums from their concrete shields is not possible. So different methods were tested to find a way of non-destructive extraction of old waste drums from cement shields and therefore reduce the final repository volume and final repository costs by using a container accepted and approved for Konrad. The main objective was to build a mobile system to offer this service to nuclear plant stations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chernobyl NPP: Completion of LRW Treatment Plant and LRW Management on Site - 12568

Since a beginning of ChNPP operation, and after a tragedy in 1986, a few thousands m3 of LRW have been collected in a storage tanks. In 2004 ChNPP started the new project on creation of LRW treatment plant (LRWTP) financed from EBRD fund. But it was stopped in 2008 because of financial and contract problems. In 2010 SIA RADON jointly with Ukrainian partners has won a tender on completion of LRWTP, in particular I and C system. The purpose of LRTP is to process liquid rad-wastes from SSE 'Chernobyl NPP' site and those liquids stored in the LRWS and SLRWS tanks as well as the would-be wastes after ChNPP Power Units 1, 2 and 3 decommissioning. The LRTP design lifetime - 20 years. Currently, the LRTP is getting ready to perform the following activities: 1. retrieval of waste from tanks stored at ChNPP LWS using waste retrieval system with existing equipment involved; 2. transfer of retrieved waste into LRTP reception tanks with partial use of existing transfer pipelines; 3. laboratory chemical and radiochemical analysis of reception tanks contest to define the full spectrum of characteristics before processing, to acknowledge the necessity of preliminary processing and to select end product recipe; 4. preliminary processing of the waste to meet the requirements for further stages of the process; 5. shrinkage (concentrating) of preliminary processed waste; 6. solidification of preliminary processed waste with concrete to make a solid-state (end product) and load of concrete compound into 200-l drums; 7. curing of end product drums in LRTP curing hall; 8. radiologic monitoring of end product drums and their loading into special overpacks; 9. overpack radiological monitoring; 10. send for disposal (ICSRM Lot 3); The current technical decisions allow to control and return to ChNPP of process media and supporting systems outputs until they satisfy the following quality norms: salt content: < 100 g/l; pH: 1 - 11; anionic surface-active agent: < 25 mg/l; oil dissipated in the liquid: < 2 mg/l; overall gamma-activity: < 3,7 x10{sup 5} Bq/l. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Resolution Scanning Configurations for the Canberra Tomographic Gamma Scanner - 17323

The Canberra Tomographic Gamma Scanner (TGS) is a Non-Destructive Assay (NDA) system that combines high resolution gamma ray spectroscopy (HRGS) with low-spatial-resolution imaging for the measurement of heterogeneous drummed waste with matrix densities in the range of 0 to 1 g/cc. The TGS methodology uses a two-pass scanning protocol; a 10-15 μCi {sup 152}Eu transmission source is used to interrogate density and composition of the matrix in the first pass, and passive gamma ray spectroscopy is used to collect emission spectra in the second, while the drum is rotated and translated to vary the view path. In standard implementations, the transmission and emission data are used to reconstruct three dimensional images of the matrix and activity distribution inside the drum on a 10x10x16 grid of discrete volume elements or 'voxels'. These images allow attenuation corrections to be calculated and applied on a view by view, and voxel by voxel basis, reducing the over- and under-correction biases obtained by assay techniques which assume homogeneous distributions of material. The most recent TGS system deployed by Canberra featured, among other new developments, the ability to perform higher resolution image re-construction, which may prove beneficial for the assay of more highly mixed matrices or oddly shaped assay items within a container. These additional scanning protocols reconstruct the image data into 14x14 and 20x20 voxel grids, using a smaller collimator aperture size. The hardware and software implementations of these higher resolution scans are discussed, and the calibration and initial evaluations of performance are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗