At least 325 records · Page 18

Microstructure, Processing, Performance Relationships for High Temperature Coatings

HVOF coating have shown high resistance to corrosion in fossil energy applications and it is generally accepted that mechanical failure, e.g. cracking or spalling, ultimately will determine coating lifetime. The high velocity oxygen-fuel method (HVOF) of applying coatings is one of the most commercially viable and allows the control of various parameters including powder particle velocity and temperature which influence coating properties, such as residual stress, bond coat strength and microstructure. Methods of assessing the mechanical durability of coatings are being developed in order to explore the relationship between HVOF spraying parameters and the mechanical properties of the coating and coating bond strength. The room temperature mechanical strength, as well as the resistance of the coating to cracking/spalling during thermal transients, is of considerable importance. Eddy current, acoustic emission and thermal imaging methods are being developed to detect coating failure during thermal cycling tests and room temperature tensile tests. Preliminary results on coating failure of HVOF FeAl coatings on carbon steel, as detected by eddy current measurements during thermal cycling, are presented. The influence of HVOF coating parameters of iron aluminides - applied to more relevant structural steels, like 316 SS and Grade 91 steel, - on coating durability will be explored once reliable methods for identification of coating failure have been developed.

20 FOSSIL-FUELED POWER PLANTS↗

AC losses of Roebel and CORC ® cables at higher AC magnetic fields and ramp rates

We have measured ReBCO coated conductor-based conductor on round core (CORC ® ) and Roebel cables at 77 K in a spinning magnet calorimeter, which subjected the tapes in the samples to a radial magnetic field of 566 mT (peak) at frequencies up to 120 Hz (272 T s -1 , cyclic average) with an approximately sinusoidal waveform. The samples were oriented such that the field applied to the tapes within the cables was entirely radial, simplifying subsequent analysis. An expression for loss which included hysteretic, flux creep and eddy current losses was fit to both the CORC ® and the Roebel cables. This expression allowed easy comparison of the relative influence of eddy currents and flux creep (or power-law behavior) effects. The loss of both the CORC ® and Roebel cables measured here were seen to be essentially the sum of the hysteretic loss, flux creep effects, and the normal metal eddy current losses of the individual tapes. The losses of these cables were measured at high B × d B /d t with no coupling current loss observed under the present preparation conditions. The influence of flux creep effects on loss were not negligible. The losses of the CORC ® cable per meter of tape were seen to be reduced from the case of a flat tape because of the helical geometry of the tapes.

Physics↗

On the reversibility of the Meissner effect and the angular momentum puzzle

It is generally believed that the laws of thermodynamics govern superconductivity as an equilibrium state of matter, and hence that the normal-superconductor transition in a magnetic field is reversible under ideal conditions. Because eddy currents are generated during the transition as the magnetic flux changes, the transition has to proceed infinitely slowly to generate no entropy. Experiments showed that to a high degree of accuracy no entropy was generated in these transitions. However, in this paper we point out that for the length of times over which these experiments extended, a much higher degree of irreversibility due to decay of eddy currents should have been detected than was actually observed. We also point out that within the conventional theory of superconductivity no explanation exists for why no Joule heat is generated in the superconductor to normal transition when the supercurrent stops. In addition we point out that within the conventional theory of superconductivity no mechanism exists for the transfer of momentum between the supercurrent and the body as a whole, which is necessary to ensure that the transition in the presence of a magnetic field respects momentum conservation. We propose a solution to all these questions based on the alternative theory of hole superconductivity. The theory proposes that in the normal-superconductor transition there is a flow and backflow of charge in direction perpendicular to the phase boundary when the phase boundary moves. We show that this flow and backflow explains the absence of Joule heat generated by Faraday eddy currents, the absence of Joule heat generated in the process of the supercurrent stopping, and the reversible transfer of momentum between the supercurrent and the body, provided the current carriers in the normal state are holes. - Highlights: • The normal-superconductor phase transition is reversible. • Within the conventional theory, Foucault currents give rise to irreversibility. • To suppress Foucault currents, charge has to flow in direction perpendicular to the phase boundary. • The charge carriers have to be holes. • This solves also the angular momentum puzzle associated with the Meissner effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanolaminated Permalloy Core for High-Flux, High-Frequency Ultracompact Power Conversion

Metallic magnetic materials have desirable magnetic properties, including high permeability, and high saturation flux density, when compared with their ferrite counterparts. However, eddy-current losses preclude their use in many switching converter applications, due to the challenge of simultaneously achieving sufficiently thin laminations such that eddy currents are suppressed (e.g., 500 nm-1 mu m for megahertz frequencies), while simultaneously achieving overall core thicknesses such that substantial power can be handled. A CMOS-compatible fabrication process based on robot-assisted sequential electrodeposition followed by selective chemical etching has been developed for the realization of a core of substantial overall thickness (tens to hundreds of micrometers) comprised of multiple, stacked permalloy (Ni80Fe20) nanolaminations. Tests of toroidal inductors with nanolaminated cores showed negligible eddy-current loss relative to total core loss even at a peak flux density of 0.5 T in the megahertz frequency range. To illustrate the use of these cores, a buck power converter topology is implemented with switching frequencies of 1-2 MHz. Power conversion efficiency greater than 85% with peak operating flux density of 0.3-0.5 T in the core and converter output power level exceeding 5 W was achieved.

Kim, J↗

Simulation supported POD: Methodology and HFET validation case

Structure reliability guaranty requires prior evaluation of non destructive testing methods. The concept of Probability of Detection (POD) is generally used to quantitatively assess performances and reliability of testing operations. Such probabilistic approaches take into account the uncertainties that appear during inspections and that are responsible for the output variability. POD curve determination is based on costly and time consuming experimental campaigns. Increasing demand of NDT configurations requiring POD evaluation makes cost reduction of POD campaigns a major issue. A new trend is to apply simulation in the context of probabilistic approaches in order to replace some of the experimental data required to determine the POD with simulation results. This paper presents results of simulation based POD curves of a high frequency eddy current inspection procedure obtained with the new POD module of CIVA. The methodology used for describing uncertainties on the input simulation parameters is described and comparisons with experimental results are presented and discussed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Results of NDE Technique Evaluation of Clad Hydrides

This report fulfills the M4 milestone, M4FT-14IN0805023, Results of NDE Technique Evaluation of Clad Hydrides, under Work Package Number FT-14IN080502. During service, zirconium alloy fuel cladding will degrade via corrosion/oxidation. Hydrogen, a byproduct of the oxidation process, will be absorbed into the cladding and eventually form hydrides due to low hydrogen solubility limits. The hydride phase is detrimental to the mechanical properties of the cladding and therefore it is important to be able to detect and characterize the presence of this constituent within the cladding. Presently, hydrides are evaluated using destructive examination. If nondestructive evaluation techniques can be used to detect and characterize the hydrides, the potential exists to significantly increase test sample coverage while reducing evaluation time and cost. To demonstrate the viability this approach, an initial evaluation of eddy current and ultrasonic techniques were performed to demonstrate the basic ability to these techniques to detect hydrides or their effects on the microstructure. Conventional continuous wave eddy current techniques were applied to zirconium based cladding test samples thermally processed with hydrogen gas to promote the absorption of hydrogen and subsequent formation of hydrides. The results of the evaluation demonstrate that eddy current inspection approaches have the potential to detect both the physical damage induced by hydrides, e.g. blisters and cracking, as well as the combined effects of absorbed hydrogen and hydride precipitates on the electrical properties of the zirconium alloy. Similarly, measurements of ultrasonic wave velocities indicate changes in the elastic properties resulting from the combined effects of absorbed hydrogen and hydride precipitates as well as changes in geometry in regions of severe degradation. However, for both approaches, the signal responses intended to make the desired measurement incorporate a number of contributing parameters. These contributing factors need to be recognized and a means to control them or separate their contributions will be required to obtain the desired information.

36 MATERIALS SCIENCE↗

NDT and SHM of Carbon Fiber Composites using Linear Drive MWM-Arrays

Carbon fiber composites are used in a wide range of structural applications due to their excellent specific strength and stiffness. However, the anisotropic mechanical and electrical properties associated with the fibers within each composite layer present challenges, and opportunities, for Nondestructive Testing (NDT) methods used to characterize and assess the structure condition. This includes composite condition after manufacture (such as fiber orientation and density, porosity, delamination, and bond strength) and during usage (such as damage from impact, fiber breakage, thermal exposure or applied stress). Ultrasonic and thermographic methods can address some of these challenges, but eddy current methods provide an alternative method for composite structures that contain a conducting material, such as carbon fibers or a metallic liner. This presentation reviews recent advances in the development of eddy current sensors and arrays for carbon fiber composite NDT and Structural Health Monitoring (SHM) applications. The focus is on eddy current sensor constructs with linear drive windings, such as MWM -Arrays, that induce currents primarily within the linear fibers of the composite. By combining this type of sensor construct with micromechanical models that relate composite constituent properties to measurable sensor responses, insight is obtained into the volumetric distribution of electrical properties within the composite and the associated manufacturing, damage, or strain conditions. With knowledge of the fiber layup, this MWM-Array technology is able to detect damage and strain/stress as a function of depth and fiber orientation. This work has been funded by NASA, NA V AIR and the Army for applications ranging from composite overwrapped pressure vessels (COPVs) to aircraft structures and rotorcraft blades. This presentation will specifically present background on the MWM-Array technology, results from the micromechanical modeling effort, and results from ongoing efforts for high resolution imaging and volumetric strain sensing.

Washabaugh, Andrew↗

Low-Loss, High-Flux Saturation Magnetic Cores for Power Converters

As new and alternative energy sources are added to the energy grid, efficient and low-loss power converters are essential to the storage of energy from these intermittent power sources. Higher operating frequency can reduce the size and weight of transformers. However, current magnetic cores limit the operating frequency because core losses increase with frequency. Therefore, new magnetic core materials are needed with higher resistivity (lower eddy-current losses), lower coercivity (lower hysteresis losses), and higher permeability and flux density (higher power density). These new materials must be integrated into isolated power converters designed to optimize efficiency based on the transformer performance. To address this need, Mainstream pursued a two-pronged approach in Phase I to develop novel magnetic materials and model a planar transformer design. We irradiated silicon steel with a high-energy electron beam in an attempt to induce nanocrystalline grain formation. The nanocrystalline grains were expected to increase resistivity to reduce eddy-current losses and decrease coercivity to reduce hysteresis losses. We also modeled the transformer performance through Simulation Program with Integrated Circuit Emphasis (SPICE) and analytical models to establish the effect of magnetic properties of the core on the performance of the transformer. There still are hurdles to be overcome in Phase II. The electron beam processing was successful in increasing the resistivity and the flux saturation density. However, the resistivity is still too low for high-frequency magnetic cores, because the eddy-current losses would be prohibitively high. Additionally, the coercivity increased for the processed samples leading to higher hysteresis losses. In comparing our SPICE and analytical models to the planar transformer measured values and impedance plots, good agreement was seen for primary and secondary short-circuit impedance measurements and for primary-to-secondary capacitance measurements. The SPICE model deviated from measured values, though, when measuring the transformer open-circuit impedance, indicating that we might need to add more model complexity to the transformer model. Phase II research will continue to build on the transformer model and integrating novel magnetic materials into high-frequency transformers.

15 GEOTHERMAL ENERGY↗

Robotic NDE inspection of advanced solid rocket motor casings

The Advanced Solid Rocket Motor program determined the need to inspect ASRM forgings and segments for potentially catastrophic defects. To minimize costs, an automated eddy current inspection system was designed and manufactured for inspection of ASRM forgings in the initial phases of production. This system utilizes custom manipulators and motion control algorithms and integrated six channel eddy current data acquisition and analysis hardware and software. Total system integration is through a personal computer based workcell controller. Segment inspection demands the use of a gantry robot for the EMAT/ET inspection system. The EMAT/ET system utilized similar mechanical compliancy and software logic to accommodate complex part geometries. EMAT provides volumetric inspection capability while eddy current is limited to surface and near surface inspection. Each aspect of the systems are applicable to other industries, such as, inspection of pressure vessels, weld inspection, and traditional ultrasonic inspection applications.

Mcneelege, Glenn E.↗

NDE to Manage Atmospheric SCC in Canisters for Dry Storage of Spent Fuel: An Assessment

This report documents efforts to assess representative horizontal (Transuclear NUHOMS®) and vertical (Holtec HI-STORM) storage systems for the implementation of non-destructive examination (NDE) methods or techniques to manage atmospheric stress corrosion cracking (SCC) in canisters for dry storage of used nuclear fuel. The assessment is conducted by assessing accessibility and deployment, environmental compatibility, and applicability of NDE methods. A recommendation of this assessment is to focus on bulk ultrasonic and eddy current techniques for direct canister monitoring of atmospheric SCC. This assessment also highlights canister regions that may be most vulnerable to atmospheric SCC to guide the use of bulk ultrasonic and eddy current examinations. An assessment of accessibility also identifies canister regions that are easiest and more difficult to access through the ventilation paths of the concrete shielding modules. A conceivable sampling strategy for canister inspections is to sample only the easiest to access portions of vulnerable regions. There are aspects to performing an NDE inspection of dry canister storage system (DCSS) canisters for atmospheric SCC that have not been addressed in previous performance studies. These aspects provide the basis for recommendations of future efforts to determine the capability and performance of eddy current and bulk ultrasonic examinations for atmospheric SCC in DCSS canisters. Finally, other important areas of investigation are identified including the development of instrumented surveillance specimens to identify when conditions are conducive for atmospheric SCC, characterization of atmospheric SCC morphology, and an assessment of air flow patterns over canister surfaces and their influence on chloride deposition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Parametric study of power absorption from electromagnetic waves by small ferrite spheres

Algebraic expressions in terms of elementary mathematical functions are derived for power absorption and dissipation by eddy currents and magnetic hysteresis in ferrite spheres. Skin depth is determined by using a variable inner radius in descriptive integral equations. Numerical results are presented for sphere diameters less than one wavelength. A generalized power absorption parameter for both eddy currents and hysteresis is expressed in terms of the independent parameters involving wave frequency, sphere radius, resistivity, and complex permeability. In general, the hysteresis phenomenon has a greater sensitivity to these independent parameters than do eddy currents over the ranges of independent parameters studied herein. Working curves are presented for obtaining power losses from input to the independent parameters.

Englert, Gerald W.↗

OTVE combustor wall condition monitoring

Conventional ultrasonics, eddy current, and electromagnetic acoustic transduction (EMAT) technologies were evaluated to determine their capability of measuring wall thickness/wear of individual cooling channels in test specimens simulating conditions in the throat region of an OTVE combustion chamber liner. Quantitative results are presented for the eddy current technology, which was shown to measure up to the optimum 20-mil wall thickness with near single channel resolution. Additional results demonstrate the capability of the conventional ultrasonics and EMAT technologies to detect a thinning or cracked wall. Recommendations for additional eddy current and EMAT development tests are presented.

Szemenyei, Brian↗

Modeling and Identification of a Large Gap Magnetic Suspension System

This paper presents the results of modeling and system identification efforts on the NASA Large-Angle Magnetic Suspension Test Fixture (LAMSTF). The LAMSTF consists of a cylindrical permanent magnet which is levitated above a planar array of five electromagnets mounted in a circular configuration. The analytical model is first developed and open-loop characteristics are described. The system is shown to be highly unstable and requires feedback control in order to apply system identification. Limitations on modeling accuracy due to the effect of eddy-currents on the system are discussed. An algorithm is derived to identify a state-space model for the system from input/output data acquired during closed-loop operation. The algorithm is tested on both the baseline system and a perturbed system which has an increased presence of eddy currents. It is found that for the baseline system the analytic model adequately captures the dynamics, although the identified model improves the simulation accuracy. For the system perturbed by additional unmodeled eddy-currents the analytic model is no longer adequate and a higher-order model, determined through system identification, is required to accurately predict the system's time response.

Cox, David E.↗

Electromagnetic Detection of Fatigue Cracks under Protruding Head Ferromagnetic Fasteners

The detection of fatigue cracks under installed fasteners has been a major goal of the aging aircraft NDE community. The Sliding Probe, Magneto-Optic Imager, Rotating Self-Nulling Probe, Low Frequency Eddy Current Array, and Eddyscan systems are among the instruments developed for this inspection. It has been verified that the detection of fatigue cracks under flush head aluminum and titanium fasteners can be accomplished with a high resolution by the above techniques. The detection of fatigue cracks under ferromagnetic and protruding head fasteners, however, has been found to be much more difficult. For the present work, the inspection for fatigue cracks under SAE 4340 Steel Hi-Lok fasteners is explored. Modifications to the Rotating Self-Nulling Eddy Current Probe System are presented which enable the detection of fatigue cracks hidden under the protruding head of the ferromagnetic fastener. Inspection results for samples with varying length EDM notches are shown, as well as a comparison between the signature from an EDM notch and an actual fatigue crack. Finite Element Modeling is used to investigate the effect of the ferromagnetic fastener on the induced eddy current distribution in order to help explain the detection characteristics of the system. This paper will also introduce a modification to the Rotating Probe System designed specifically for the detection of deeply buried flaws in multilayer conductors. The design change incorporates a giant magnetoresistive (GMR) sensor as the pickup device to improve the low frequency performance of the probe. The flaw detection capabilities of the GMR based Self- Nulling Probe are presented along with the status of the GMR based Rotating Probe System for detection of deeply buried flaws under installed fasteners.

Wincheski, Buzz↗

An Assessment of Additively Manufactured Bonded Permanent Magnets for a Distributed Wind Generator

In this paper, we examine and compare the performance of a generator design optimized using additively manufactured NdFeB-SmFeN in nylon-polymer-bonded permanent magnets (PMs) against a generator design with conventional NdFeB sintered PMs. To realize this, a commercially available 15-kW wind generator's rotor is re-optimized using both additively manufactured and sintered NdFeB magnets using simple geometric parameterization that allowed for two specific magnet shapes, namely, arc-shaped and crown-shaped designs. Results showed that for a similar generator performance, the designs with additively manufactured bonded PMs are more cost-competitive in terms of the estimated PM material cost and also have negligible eddy current magnet losses.

additive manufacturing↗

Frequency-Dependent Properties of Magnetic Nanoparticle Crystals

In the proposed research program we will investigate the time- and frequency-dependent behavior of ordered nanoparticle assemblies, or nanoparticle crystals. Magnetostatic interactions are long-range and anisotropic, and this leads to complex behavior in nanoparticle assemblies, particularly in the time- and frequency-dependent properties. We hypothesize that the high frequency performance of composite materials has been limited because of the range of relaxation times; if a composite is a dipolar ferromagnet at a particular frequency, it should have the advantages of a single phase material, but without significant eddy current power losses. Arrays of surfactant-coated monodomain magnetic nanoparticles can exhibit long-range magnetic order that is stable over time. The magnetic domain size and location of domain walls is governed not by structural grain boundaries but by the shape of the array, due to the local interaction field. Pores or gaps within an assembly pin domain walls and limit the domain size. Measurements of the magnetic order parameter as a function of temperature showed that domains can exist at high temoerature, and that there is a collective phase transition, just as in an exchange-coupled ferromagnet. Dipolar ferromagnets are not merely of fundamental interest; they provide an interesting alternative to exchange-based ferromagnets. Dipolar ferromagnets made with high moment metallic particles in an insulating matrix could have high permeability without large eddy current losses. Such nanocomposites could someday replace the ferrites now used in phase shifters, isolators, circulators, and filters in microwave communications and radar applications. We will investigate the time- and frequency-dependent behavior of nanoparticle crystals with different magnetic core sizes and different interparticle barrier resistances, and will measure the magnetic and electrical properties in the DC, low frequency (0.1 Hz - 1 kHz), moderate frequency (10 Hz - 500 MHz), and high frequency (up to 20 GHz) regimes. Our results will demonstrate whether a DC dipolar ferromagnet shows collective frequency-dependent reponse similar to that of an exchange-based ferromagnet, and will provide data for comparison of optimal nanocomposite properties with those of ferrites used in high frequency applications. Both the magnetic and electronic response of the composites will be examined in order to determine the frequency range where hopping conductivity leads to significant eddy current power losses. In the high frequency regime we will look for evidence of spin wave quantization and the resulting decrease in non-linear spin wave processes that could affect the performance of high frequency magnetic devices.

36 MATERIALS SCIENCE↗

Laminated Permanent Magnets Enable Compact Magnetic Components in Current-Source Converters

Magnetic components have become one of the primary barriers to high power density converters, especially to current-source converters (CSCs). In CSCs, the inductors/transformers have a predominantly dc flux to store energy, which can be offset by standard permanent magnets (PMs). However, eddy currents in standard PMs induce significant losses and thermal stress for medium-frequency applications. This article proposes using laminated PMs to offset the dc flux while reducing eddy currents, leading to significant reductions in the size, cost, and losses of inductors/transformers. Furthermore, the laminated PMs’ optimal location, orientation, and distribution are investigated to generalize this approach for maximum benefits. Here, three-dimensional finite-element analysis simulation and hardware experiments are presented to validate the effectiveness of the proposed approach in a medium-frequency transformer (MFT) for CSCs. Compared with standard PMs, the proposed use of laminated PMs reduces aggregate core-plus-PM losses by 85% in experiments, and thus, relaxes the MFT thermal design. Finally, the proposed approach is experimentally validated in a 40 kVA flyback-type MFT for a soft-switching solid-state transformer. Compared to the traditional design without any PMs, the proposed design increases the saturation current by 46% while inducing only 5% more losses, leading to significant savings in magnetics cost and size.

30 DIRECT ENERGY CONVERSION↗

Wet chemistry-synthesized Fe/mixed ferrite soft magnetic composites for high-frequency power conversion

State-of-the-art soft magnetic (SM) alloy systems such as electrical steels and permalloys exhibit large eddy current losses at high-frequency (kHz range and above), limiting their application in fast switching devices. Eddy current losses can be reduced for metallic alloys through a decrease in characteristic length scale or embedding them in an insulation layer. This work proposes the development of fine-scale core materials consisting of metallic SM nano/microparticles with magnetic, inorganic insulation layers, and their synthesis using a wet chemistry-based, scalable method for high frequency and high-power applications. More specifically, a magnetic ferrite coating (Ni 0.5-x Mn x Zn 0.5 Fe 2 O 4 , x = 0.0–0.5) was applied via deposition of ferrite powder produced using a “wet chemistry-based” co-precipitation method; the ferrite was distributed through the Fe micropowder via either ball milling or ultrasonic mixing. Powder cores were prepared by compaction of the synthesized composites. Relative magnetic permeability and core loss were measured at excitation frequencies to 200 kHz. A core loss of 127 kW/m 3 was measured at excitation frequency of 100 kHz and magnetization of 0.02 T. This value improves on the 199.3 kW/m 3 reported in literature at identical excitation conditions for a compact formed from a composite comprising Fe microparticles coated with low-permeability Ni 0.5 Zn 0.5 Fe 2 O 4 . Ultrasonic mixing resulted in slightly lower core loss than ball milling, possibly because ball milling causes loss-increasing deformation of the Fe micropowder. XRD and SEM were used to observe composite composition and core cross-section microstructure.