Search NASA⌕ Search

SEARCH · Search NASA

Results for “edge sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber↗

Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Cutting Edge Technologies Presentation: An Overview of Developing Sensor Technology Directions and Possible Barriers to New Technology Implementation

The aerospace industry requires the development of a range of chemical sensor technologies for such applications as leak detection, emission monitoring, fuel leak detection, environmental monitoring, and fire detection. A range of chemical sensors are being developed based on micromachining and microfabrication technology to fabricate microsensors with minimal size, weight, and power consumption; and the use of nanomaterials and structures to develop sensors with improved stability combined with higher sensitivity, However, individual sensors are limited in the amount of information that they can provide in environments that contain multiple chemical species. Thus, sensor arrays are being developed to address detection needs in such multi-species environments. These technologies and technical approaches have direct relevance to breath monitoring for clinical applications. This presentation gives an overview of developing cutting-edge sensor technology and possible barriers to new technology implementation. This includes lessons learned from previous microsensor development, recent work in development of a breath monitoring system, and future directions in the implementation of cutting edge sensor technology.

Hunter, Gary W.↗

Edge‐Driven Fringe‐Field Effects, Reduced Screening, and Bandgap Widening in Graphene Nanoribbons Enable Single‑Molecule Sensitivity

Graphene nanoribbons (GNRs) offer promising platforms for single‐molecule sensing due to their quasi‐1D channels and discrete electronic states, providing superior sensitivity toward molecular perturbations. While prior studies emphasize smoother edges as essential for optimal performance, the potential benefits of controlled edge roughness remain largely unexplored. Additionally, most investigations focus on GNR arrays, leaving critical edge‐ and width‐dependent factors, including fringe fields, bandgap widening, interactions between adsorbing molecules and GNR atoms, density of states (DOS) suppression, and electrostatic screening lengths, and their collective impact on sensitivity, poorly understood. Here, in this work, we fabricated field‐effect transistors using individual GNRs (widths: 200–20 nm) and characterized their response to molecular adsorption with perfluorooctanoic acid as the model analyte. Narrower ribbons displayed significantly enhanced sensitivity, yielding a coverage‐normalized response of 116 ± 10 mV per molecule in 20 nm‐wide GNRs (from calibrated ensemble Dirac‐point shifts). Experimental and theoretical analyses reveal that this heightened sensitivity arises from stronger fringe fields, width‐dependent quantum confinement effects, reduced DOS, and increased edge roughness that facilitates molecular anchoring, enhanced orbital overlap, and improved charge transfer efficiency. Our findings challenge the conventional assumption that smoother edges inherently enhance sensor performance, demonstrating that controlled edge disorder substantially boosts molecular sensitivity in GNR sensors.

36 MATERIALS SCIENCE↗

Real-time edge tracking using a tactile sensor

Object recognition through the use of input from multiple sensors is an important aspect of an autonomous manipulation system. In tactile object recognition, it is necessary to determine the location and orientation of object edges and surfaces. A controller is proposed that utilizes a tactile sensor in the feedback loop of a manipulator to track along edges. In the control system, the data from the tactile sensor is first processed to find edges. The parameters of these edges are then used to generate a control signal to a hybrid controller. Theory is presented for tactile edge detection and an edge tracking controller. In addition, experimental verification of the edge tracking controller is presented.

Berger, Alan D.↗

Development and Feasibility Testing of Image-Guided Minimally Invasive Tissue for Diagnosis Treatment of Benign and Malignant Breast Disease

Dr. Robert Mah and Dr. Stefanie Jeffrey worked on the development of the NASA Smart Probe in its application as a device to measure and interpret physiologic and image-based parameters of breast tissue. To date the following has been achieved: 1 . Choice of candidate sensors to be tested in breast tissue. 2. Preliminary designs for probe tip, specifically use of different tip shapes, cutting edges, and sensor configuration. 3. Design of sonographic guidance system. 4. Design of data extraction and analysis tool using scanned information of images of the breast tissue to provide a higher dimension of information for breast tissue characterization and interpretation. 5. Initial ex-vivo (fruit and tofu) and in-vivo (rodent) testing to confirm unique substance and tissue characterization by the Smart Probe software.

Jeffrey, Stefanie S.↗

Miniaturized Airborne Imaging Central Server System

In recent years, some remote-sensing applications require advanced airborne multi-sensor systems to provide high performance reflective and emissive spectral imaging measurement rapidly over large areas. The key or unique problem of characteristics is associated with a black box back-end system that operates a suite of cutting-edge imaging sensors to collect simultaneously the high throughput reflective and emissive spectral imaging data with precision georeference. This back-end system needs to be portable, easy-to-use, and reliable with advanced onboard processing. The innovation of the black box backend is a miniaturized airborne imaging central server system (MAICSS). MAICSS integrates a complex embedded system of systems with dedicated power and signal electronic circuits inside to serve a suite of configurable cutting-edge electro- optical (EO), long-wave infrared (LWIR), and medium-wave infrared (MWIR) cameras, a hyperspectral imaging scanner, and a GPS and inertial measurement unit (IMU) for atmospheric and surface remote sensing. Its compatible sensor packages include NASA s 1,024 1,024 pixel LWIR quantum well infrared photodetector (QWIP) imager; a 60.5 megapixel BuckEye EO camera; and a fast (e.g. 200+ scanlines/s) and wide swath-width (e.g., 1,920+ pixels) CCD/InGaAs imager-based visible/near infrared reflectance (VNIR) and shortwave infrared (SWIR) imaging spectrometer. MAICSS records continuous precision georeferenced and time-tagged multisensor throughputs to mass storage devices at a high aggregate rate, typically 60 MB/s for its LWIR/EO payload. MAICSS is a complete stand-alone imaging server instrument with an easy-to-use software package for either autonomous data collection or interactive airborne operation. Advanced multisensor data acquisition and onboard processing software features have been implemented for MAICSS. With the onboard processing for real time image development, correction, histogram-equalization, compression, georeference, and data organization, fast aerial imaging applications, including the real time LWIR image mosaic for Google Earth, have been realized for NASA fs LWIR QWIP instrument. MAICSS is a significant improvement and miniaturization of current multisensor technologies. Structurally, it has a complete modular and solid-state design. Without rotating hard drives and other moving parts, it is operational at high altitudes and survivable in high-vibration environments. It is assembled from a suite of miniaturized, precision-machined, standardized, and stackable interchangeable embedded instrument modules. These stackable modules can be bolted together with the interconnection wires inside for the maximal simplicity and portability. Multiple modules are electronically interconnected as stacked. Alternatively, these dedicated modules can be flexibly distributed to fit the space constraints of a flying vehicle. As a flexibly configurable system, MAICSS can be tailored to interface a variety of multisensor packages. For example, with a 1,024x1,024 pixel LWIR and a 8,984x6,732 pixel EO payload, the complete MAICSS volume is approximately 7x9x11 in. (=18x23x28 cm), with a weight of 25 lb (=11.4 kg).

Sun, Xiuhong↗

Wavefront Controls for a Large Submillimeter-Wave Observatory

The 25-m aperture Cornell Caltech Atacama Telescope (CCAT) will have a primary mirror that is divided into 162 individual segments, each of which is equipped with 3 positioning actuators. This paper presents a mathematical description of the telescope, its actuators and sensors, and uses it to derive control laws for figure maintenance. A Kalman Filter-based Optical State Estimator is used to continuously estimate the aberrations of the telescope; these are used in a state-feedback controller to maintain image quality. This approach provides the means to correct for the optical effects of errors that occur in unactuated degrees of freedom, such as lateral translations of the segments. The control laws are exercised in Monte Carlo and covariance analysis, to bound the closed-loop performance of the telescope and to conduct control design trades.

edge sensors↗

Two-Stage Wildlife Event Classification for Edge Deployment

Camera-based wildlife monitoring is often overwhelmed by non-target triggers and slowed by manual review or cloud-dependent inference, which can prevent timely intervention for high stakes human–wildlife conflicts. Our key contribution is a deployable, fully offline edge vision sensor that achieves near-real-time, highly accurate wildlife event classification by combining detector-based empty-image suppression with a lightweight classifier trained with a staged transfer-learning curriculum. Specifically, Stage 1 uses a pretrained You Only Look Once (YOLO)-family detector for permissive animal localization and empty-trigger suppression, and Stage 2 uses a lightweight EfficientNet-based binary classifier to confirm puma on detector crops and gate downstream actions. Our design is robust to low-quality nighttime monochrome imagery (motion blur, low contrast, illumination artifacts, and partial-body captures) and operates using commercially available components in connectivity-limited settings. In field deployments running since May 2025, end-to-end latency from camera trigger to action command is approximately 4 s. Ablation studies using a dataset of labeled wildlife images (pumas, not pumas) show that the two-stage approach substantially reduces false alarms in identifying pumas relative to a full-image classifier while maintaining high recall. On the held-out test set (N = 1434 events), the proposed two-stage cascade achieves precision 0.983, recall 0.975, F1 0.979, accuracy 0.986, and balanced accuracy 0.983, with only 8 false positives and 12 false negatives. The system can be easily adapted for other species, as demonstrated by rapid retraining of the second stage to classify ringtails. Downstream responses (e.g., notifications and optional audio/light outputs) provide flexible actuation capabilities that can be configured to support intervention.

58 GEOSCIENCES↗

Absorber Clamp for Microcalorimeter Decay Energy Spectrometry

Microcalorimeter Decay Energy Spectrometry (DES) is of interest to nuclear safeguards due to its ability to provide high precision isotopic compositions of nanogram-to microgram-scale samples of Pu and U and related daughter products. The DES method is able to record decay energy of each alpha-decay event in a sample that is embedded in a metal matrix (absorber) and thermally linked to a microcalorimeter detector. This work optimizes the DES technique used to thermally link the absorber and microcalorimeter detector element to allow for more rapid assembly and to increase detector performance and operating life. Optimized attachment methods are crucial for enhancing the viability of DES in high-sample-throughput facilities, such as those that support international nuclear safeguards measurements. Here, in this study, we designed and implemented a pressure-based absorber clamp and evaluated the performance of this new attachment method relative to pressed indium bond attachment. Results using the absorber clamp demonstrate a streamlined detector assembly procedure that minimizes accidental damage to detectors, as well as increasing detector pulse speeds by 57%. Spectral comparison shows the clamp preserves detector performance relative to indium attachment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Resolution Fission Fragment Spectroscopy with Superconducting Microcalorimeters

Sub-1 AMU mass determination is important for determining fission yields and neutron multiplicity, which are necessary inputs for fission models. Fission models can improve spent nuclear waste stream analysis and nuclear fuel burnup determination. Here, to achieve this goal, we have used superconducting microcalorimeter detectors to directly measure the energy of fission fragments from the spontaneous fission of 252 Cf. With a fiber coupled LED pulser setup we demonstrate that we can reach a relative energy resolution of 0.1% and better for photon pulses with energies above 60 MeV. This instrument, in conjunction with time-of-flight (TOF) measurement, would allow for sub-1 atomic mass unit (AMU) mass determination of fission fragments in a future beamline application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and validation of a cold load for characterization of cosmic microwave background stage 4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by cosmic microwave background stage 4 (CMB-S4), the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three innovative design features: (1) the ability to operate from the 1-K stage of a dilution refrigerator (DR), (2) a He3 gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150-GHz detector array previously deployed by the Spider experiment. Thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1-K stage. In addition, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and validation of a cold load for characterization of CMB-S4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by CMB-S4, the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three novel design features: (1) the ability to operate from the 1 K stage of a dilution refrigerator (DR), (2) a 3He gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150 GHz detector array previously deployed by the Spider experiment. Here, thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1 K stage. Additionally, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

47 OTHER INSTRUMENTATION↗

Advanced Facility Design and AI/ML Enabled Safeguards to Establish Secure, Economical Recycling of Fast Reactor Fuels (Final Scientific/Technical Report)

The project, "Advanced Facility Design and AI/ML Enabled Safeguards to Establish Secure, Economical Recycling of Fast Reactor Fuels," represents a significant advancement in nuclear fuel recycling technology. It integrates cutting-edge multimodal sensor fusion, machine learning (ML), and digital twin (DT) technologies to address challenges in material safeguarding, process optimization, and regulatory compliance for pyroprocessing facilities. This research has significantly enhanced the understanding of pyrochemical fuel recycling processes by developing innovative tools and methodologies. The Multimodal Safeguards Monitoring Unit (MSMU) combines electroanalytical techniques, Raman spectroscopy, and differential thermal analysis (DTA) to enable high-fidelity, near-real-time material accountancy measurements. Machine learning techniques, such as Long Short-Term Memory (LSTM) autoencoders, are utilized to detect anomalies in material balances and sensor data, improving the reliability of safeguards monitoring. Additionally, digital twin technology has been established to provide real-time system-level monitoring and diagnostics, integrating physics-based models with sensor data to optimize process safety and efficiency.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Concept and analytical basis for revistas - A fast, flexible computer/graphic system for generating periodic satellite coverage patterns

The generation of satellite coverage patterns is facilitated by three basic strategies: use of a simplified physical model, permitting rapid closed-form calculation; separation of earth rotation and nodal precession from initial geometric analyses; and use of symmetries to construct traces of indefinite length by repetitive transposition of basic one-quadrant elements. The complete coverage patterns generated consist of a basic nadir trace plus a number of associated off-nadir traces, one for each sensor swath edge to be delineated. Each trace is generated by transposing one or two of the basic quadrant elements into a circle on a nonrotating earth model sphere, after which the circle is expanded into the actual 'helical' pattern by adding rotational displacements to the longitude coordinates. The procedure adapts to the important periodic coverage cases by direct insertion of the characteristic integers N and R (days and orbital revolutions, respectively, per coverage period).

King, J. C.↗

Simulation of landsat thematic mapper imagery using AVIRIS hyperspectral imagery

In this paper we present a methodology for simulating multispectral imagery (MSI) using hyperspectral imagery (HSI), and present a validation of the technique using one nearly coincident Landsat TM and AVIRIS data set. Generation of MSI from HSI supports several investigations including selection of multispectral sensor band edges, and engineering trade studies related to on-board or ground-based aggregation of HSI to simulate MSI. In addition, the utility of this technique as a potential procedure for monitoring calibration changes in spaceborne instrument is also addressed.

Kalman, Linda S.↗

Return to Flight Resource Reel 1 of 2

A video presentation detailing the tests performed on the Space Shuttle Discovery in preparation for its return to flight is shown. The tests include: 1) Reinforced Carbon-Carbon (RCC) Impact Test Article; 2) RCC Foam Impact Testing; 3) Thermal Protection System (TPS) Ice Impact Testing featuring Justin Kerr, Project Engineer; 4) Wing Leading Edge Wireless Sensors featuring Karl Kiefer, President and CEO of Invocon, and Kevin Champaigne of Invocon; 5) TPS Repair Testing KC-135 Zero-G Environment featuring Soichi Noguchi, Mission Specialist; 6) TPS Extravehicular Activity Tool Demonstration; 7) TPS Repair Testing Vacuum Glove box; 8) TPS Repair Testing Human Thermal Vacuum Chamber; 9) TPS Reentry Testing Atmospheric Reentry Materials and Structures Evaluation Facility; 10) TPS Alternative Repair Concept; 11) Lora Bailey Lead Engineer for EVA Tools; 12) Reinforced Carbon-Carbon ATK Thiokol Plug Repair Animation; 13) 3-Percent Model Build-Up; and 14) Wind Tunnel Testing RCC Aging Research Ballistic Testing.

Source record↗