Safeguards Envelope Progress FY09

The Safeguards Envelope is a strategy to determine a set of specific operating parameters which nuclear facilities may operate within to maximize safeguards effectiveness without sacrificing safety or plant efficiency. This paper details advanced statistical techniques will be applied to real plant process monitoring (PM) data from the Idaho Chemical Processing Plant (ICPP). As a result of the U.S. having no operating nuclear chemical reprocessing plants, there has been a strong interest in obtaining process monitoring data from the ICPP. The ICPP was shut down in 1996 and a recent effort has been made to retrieve the PM data from storage in a data mining effort. In a simulation based on this data, multi-tank and multi-attribute correlations were tested against synthetic diversion scenarios. Kernel regression smoothing was used to fit a curve to the historical data, and multivariable, residual analysis and cumulative sum techniques set parameters for operating conditions. Diversion scenarios were created and tested, showing improved results when compared with a previous study utilizing only one-variable Z- testing7.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of the concentration ratio on energetic and exergetic performance of concentrating solar collectors with integrated transparent insulation materials

The effect of the concentration ratio on the performance of parabolic trough and central receiver collectors with integrated Transparent Insulation Materials (TIMs) is analyzed in this work. A model based on optical, energy, and exergy analyses is developed to determine thermal and second law efficiencies of concentrated solar collectors as a function of the absorber temperature and concentration ratio. The results are compared with the respective traditional collector configurations without TIM. In general, high concentration ratios are fundamental to maintain high efficiencies. The incorporation of a TIM into concentrated solar collectors leads to higher thermal efficiencies at high operating temperatures even at low concentration ratios. An equivalent second law efficiency to that of the reference collector configuration can be achieved at lower concentration ratios by incorporating a TIM in parabolic trough or a TIM and a glass envelope in central receiver collectors. As a result, the idea of using a TIM deserves further exploration as it seems to be a promising alternative that contributes to a more efficient and cost-effective technology.

14 SOLAR ENERGY↗

Lactoferricins impair the cytosolic membrane of Escherichia coli within a few seconds and accumulate inside the cell

We report the real-time response of Escherichia coli to lactoferricin-derived antimicrobial peptides (AMPs) on length scales bridging microscopic cell sizes to nanoscopic lipid packing using millisecond time-resolved synchrotron small-angle X-ray scattering. Coupling a multiscale scattering data analysis to biophysical assays for peptide partitioning revealed that the AMPs rapidly permeabilize the cytosolic membrane within less than 3 s—much faster than previously considered. Final intracellular AMP concentrations of ~80–100 mM suggest an efficient obstruction of physiologically important processes as the primary cause of bacterial killing. On the other hand, damage of the cell envelope and leakage occurred also at sublethal peptide concentrations, thus emerging as a collateral effect of AMP activity that does not kill the bacteria. This implies that the impairment of the membrane barrier is a necessary but not sufficient condition for microbial killing by lactoferricins. The most efficient AMP studied exceeds others in both speed of permeabilizing membranes and lowest intracellular peptide concentration needed to inhibit bacterial growth.

59 BASIC BIOLOGICAL SCIENCES↗

High energy conversion efficiency in laser-proton acceleration by controlling laser-energy deposition onto thin foil targets

An all-optical approach to laser-proton acceleration enhancement is investigated using the simplest of target designs to demonstrate application-relevant levels of energy conversion efficiency between laser and protons. Controlled deposition of laser energy, in the form of a double-pulse temporal envelope, is investigated in combination with thin foil targets in which recirculation of laser-accelerated electrons can lead to optimal conditions for coupling laser drive energy into the proton beam. This approach is shown to deliver a substantial enhancement in the coupling of laser energy to 5–30 MeV protons, compared to single pulse irradiation, reaching a record high 15% conversion efficiency with a temporal separation of 1 ps between the two pulses and a 5 μm-thick Au foil. A 1D simulation code is used to support and explain the origin of the observation of an optimum pulse separation of ∼1 ps.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

RLUOB Celebration

Los Alamos National Laboratory's newest facility, the Radiological Laboratory Utility Office Building (RLUOB), is also its first to achieve both the Leadership in Energy and Environmental Design (LEED) status and LEED Gold certification from the U.S. Green Building Council (USGBC). From its robust design to its advanced scientific equipment, RLUOB is essential to the Laboratory's national security mission in support of the National Nuclear Security Administration's (NNSA) nuclear weapons program. At more than 200,000 square feet, this building is the only radiological facility within the Department of Energy to have attained LEED Gold, which contributes to NNSA's achievement towards the high performance sustainable building goals outlined in Executive Order 13514, Federal Leadership in Environmental, Energy, and Economic Performance. 'As we celebrate RLUOB being completed almost one year ahead of schedule and having achieved LEED certification at the Gold level, we approach our plutonium mission at Los Alamos and NNSA with a great sense of achievement,' said Don Cook, NNSA's deputy administrator for defense programs. 'RLUOB adds a major component to NNSA's plutonium support capability and RLUOB demonstrates our commitment in helping to deliver President Obama's nuclear security agenda which includes ensuring the safety, security and effectiveness of the nuclear deterrent without testing.' The facility contains laboratories for analytical chemistry and materials characterization of special nuclear material, along with space for offices, training and emergency operations. Its multi-functional purpose makes RLUOB a unique project for which LEED certification was sought. 'LEED certification was a huge goal and one we sought from the very beginning of this project,' said Laboratory Director Charlie McMillan. 'It's an important step forward, allowing us to advance national security science in modern, safer, more efficient infrastructure.' The Laboratory's project team and its contractor partners, especially in coordination with Jacobs Engineering, focused on green design and construction in LEED categories, such as sustainable sites, water efficiency, energy and atmosphere, materials and resources, indoor environmental quality and innovation in design. RLUOB's features include: (1) Building envelope design (orientation, materials and insulation) yielded a 20 percent improvement in energy performance; (2) Incorporation of building materials with 24 percent recycled content; (3) Diversion of 72 percent of construction-generated materials through reuse, recycle and salvage; (4) Roofing comprised of 93 percent highly-reflective materials to reduce heat island effects; (5) High efficiency, gas-fired hot water boilers, air-cooled chillers, thermal storage systems and variable frequency drives for compressors, fans and pumps; (6) Energy efficient lighting for interiors, exteriors, process glove boxes and fume hoods; (7) Water efficient fixtures resulting in 30 percent reduction in usage; (8) Low emission paints and carpeting for improved indoor air quality; (9) Landscaping that doesn't require permanent irrigation; (10) Enhanced building system commissioning; and (11) Comprehensive transportation alternatives, including public transportation, bicycle storage and changing rooms, and a refueling station for government vehicles using alternative fuels. 'RLUOB's LEED certification demonstrates tremendous leadership in green building,' says Rick Fedrizzi, president and CEO of USGBC. 'The urgency of our mission has challenged the industry to move faster and reach further than ever before, and RLUOB serves as a prime example of just how much we can accomplish.'

25 ENERGY STORAGE↗

CAN HELIUM ENVELOPES CHANGE THE OUTCOME OF DIRECT WHITE DWARF COLLISIONS?

A pivotal feature for the viability of white dwarf (WD) collisions as SN Ia progenitors is that a significant fraction of the mass is highly compressed to the densities required for efficient {sup 56}Ni production before the ignition of the detonation wave. Previous studies have employed model WDs composed of carbon–oxygen (CO), whereas WDs typically have a non-negligible helium envelope. Given that helium is more susceptible to explosive burning than CO under the conditions of WD collision, a legitimate concern is whether or not early time He detonation ignition can lead to early time CO detonation, drastically reducing {sup 56}Ni synthesis. We investigate the role of He in determining the fate of WD collisions by performing a series of two-dimensional hydrodynamics calculations. We find that a necessary condition for non-trivial reduction of the CO ignition time is that the He detonation birthed in the contact region successfully propagates into the unshocked shell. We determine the minimal He shell mass as a function of the total WD mass that upholds this condition. Although we utilize a simplified reaction network similar to those used in previous studies, our findings are in good agreement with detailed investigations concerning the impact of network size on He shell detonations. This allows us to extend our results to the case with more realistic burning physics. Based on the comparison of these findings against evolutionary calculations of WD compositions, we conclude that most, if not all, WD collisions will not be drastically impacted by their intrinsic He components.

79 ASTRONOMY AND ASTROPHYSICS↗

Building Science Education for Solar Decathlon: Emissions and the Built Environment [Slides]

The Solar Decathlon Building Science Education series is designed to educate students and working professionals on building science principles that are paramount to the successful design of high-performance, energy-efficient buildings. Instructional content is presented in modules, covering specific topics. Altogether, this series aims to educate viewers on: 1) where/how energy is used in buildings; 2) how to define zero energy buildings; 3) how to apply the fundamentals of thermodynamics to building envelope design; 4) how to explain the science of how/why buildings use energy; 5) how to apply this knowledge to design comfortable energy efficient buildings. Students and working professionals can use this educational information at no cost to complement academic curriculum and continuing education activities. This is Module 7 which focuses on embodied environmental carbon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of radiant cooling system integrated with cooling tower for composite climatic conditions

Increased demand for cooling leads to consumption of a significant amount of energy by heating, ventilation, and air conditioning (HVAC) systems in buildings. Building envelope acts as a thermal barrier and plays a significant role in improving building energy efficiency. Radiant cooling systems often utilize building structure in the form of thermal storage and provide thermal comfort. The radiant cooling system has the potential of saving peak power in the buildings. In present study experimental and a simulation study is performed for chiller and cooling tower integrated chilled ceiling radiant cooling system for chilled water source and a parallel dedicated outdoor air system (DOAS) is used for providing latent load and fresh air requirements of the zone. Cooling tower based radiant cooling system is compared with a chiller-based radiant cooling system for achieving annual energy saving. Experiments are conducted for the chiller and cooling tower operated radiant cooling system. Based on experimental data, whole building simulation models of both cooling tower and chiller-based systems were calibrated. For both the simulation model of chiller and cooling tower operated radiant cooling system simulation were carried out for round the year. The annual simulation results show that the cooling tower operated radiant cooling system saves 14% energy as compared to the chilled water operated radiating cooling system.

Srivastava, Prateek↗

Installer Badges Toolkit and Visualization Resources

NREL staff (Jal Desai and Cory Chovanec) will introduce the U.S. Department of Energy Weatherization Assistance Program (DOE WAP) Installer Badges Toolkit. The presentation will cover topics such as how this toolkit can be customized and implemented in a program, the potential benefits of using the Badges, and lessons learned from other implementers. This session will also engage participants to share their experiences regarding their existing training and how they are bringing their workforce up to speed in their building envelope-related programs. The Installer Badges Toolkit consists of 25 Badges, each representing different energy efficiency tasks that an installer could perform on a home. Each Badge defines the desired outcome, criteria to verify the work, applicable material requirements, and references to DOE's Standard Work Specifications (SWS) or other relevant standards. Workers earn Badges by completing each task and receiving approval from a qualified supervisor. The Badges provide a consistent approach to training by ensuring that installers are learning the same skills nationwide. Organizations can also customize the Toolkit by choosing only those Badges that are relevant to their program. NREL staff will also showcase new visualization resources like the Single-family and manufactured home job aids and the Single-family 3D house tool.

ENERGY PLANNING, POLICY, AND ECONOMY↗

A review of prefabricated overclad panels for building energy retrofits

Over 50% of existing buildings in the US were constructed before 1980 and lack modern, energy-efficient technologies. Despite the large number of old buildings, less than 2% of buildings are retrofitted each year with many of those retrofits consisting of small incremental improvements that often ignore the building envelope. The opaque building envelope affects 25% of building energy use equating to 10% of total US primary energy use. To meet decarbonization goals by 2035, the US must increase the rate of retrofit of existing building envelopes. The process of prefabrication is one potential opportunity to increase the rate of envelope retrofits and reduce costs. Prefabrication is the process of manufacturing construction components in a controlled environment before shipping them on-site to perform assembly of the construction. The process of prefabrication has been demonstrated to increase production efficiency, quality control, and rate of production. Prefabricated overclad panels, consisting of a cladding material and insulation designed to be installed over the existing envelope, have been successfully used to retrofit existing buildings in countries other than the US; however, the technology still has some barriers to major market adoption within the US. This paper will present a review of current implementations and demonstrations of prefabricated overclad panels. The review will include identification of panel types, materials, and applications and aims to identify barriers to retrofit market entry and widespread adoption.

Hayes, Nolan [ORNL] (ORCID:0000000332245718)↗

Sensitivity of occupant comfort models to humidity and their effect on cooling energy use

Residential building energy consumption in the United States has decreased steadily during the last several decades largely because of advances in building codes as well as voluntary efficiency and labeling programs, which have resulted in the reduction in building sensible loads. Building latent loads have not decreased by the same amount, and field and analytical research studies have concluded that high-efficiency, low-load homes often have elevated indoor humidity levels, possibly leading to occupant discomfort. There are discrepancies in the literature on occupant comfort as it relates to indoor humidity and recommended upper humidity limits. The choice of humidity limit could potentially change results and conclusions on the energy impacts of a new air conditioner or dehumidifier technology, changing ventilation rates, or an improved building envelope. In this study, we use building simulations to explore the impact of humidity control on cooling energy use in efficient residential buildings for different humidity limits. We look at limits based on humidity ratio (or dew point temperature), wet-bulb temperature, relative humidity, and constant slope lines based on the popular comfort models of both Fanger and Gagge. We quantify the additional energy use required to control humidity below these limits. We look at the sensitivity of the results to different temperature and humidity set points, occupant internal gains, moisture buffering levels, evaporator airflow rates, and dehumidifier energy factors. High-efficiency home predicted energy savings are more sensitive to the assumed humidity limit and cooling and dehumidification set points than the other parameters investigated in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning surrogate for charged particle beam dynamics with space charge based on a recurrent neural network with aleatoric uncertainty

In this work, we develop a machine learning (ML) model with aleatoric uncertainty for the low energy beam transport (LEBT) region of the LANSCE linear accelerator in which we model the transport of a space-charge-dominated 750 keV proton beam through a lattice of 22 quadrupole magnets. Our ML model is developed based on data generated by a Kapchinsky–Vladimirsky (KV) envelope model of beam transport. We show that a recurrent neural network can be used as a dynamical surrogate model for fast prediction of the LEBT beam envelope. Furthermore, we endow the model with the prediction of aleatoric uncertainty and compare three different approaches. We demonstrate that the ML-based uncertainty quantification models are well calibrated and produce good estimates of the regions where the model is less certain about its predictions. This ML framework is a necessary step in the development of a real-time virtual diagnostic tool with uncertainty quantification that can be integrated into more complex downstream tasks (e.g., adaptive control or learning flexible control policies via reinforcement learning) for improved efficiency in beam operations. In future work, we plan to expand on this preliminary study by considering more realistic envelope models that include longitudinal momentum spread and dispersive effects in bending magnets, as well as particle tracking codes with 3D space charge (such as and ). Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE↗

Timed to save: the added value of accounting for hourly incidence of electricity savings from residential space-conditioning measures

Abstract Previous research has recognized that the value of measures that reduce electricity usage depends upon the timing of the savings generated, but the lack of hourly savings shapes has limited the demonstration of this concept. We develop empirical hourly savings shapes for residential space-conditioning measures from nearly 18,000 efficiency projects in California and show how they combine with the diurnal and seasonal variation in electricity system costs. We find that these measures (cooling replacements; windows, doors, and skylights; and other envelope measures) tend to save electricity when system costs are highest and that the hourly savings account for 1.4–1.5 times as much value as non-time-sensitive estimates of efficiency would predict. We present these impact multipliers for each measure to quantify the additional value revealed by the time-sensitive approach. We show that this additional value is similar in an evolving electricity grid with storage, rather than natural gas generation, as the marginal resource.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MAR flow mapping of Analytical Chemistry Operations (Preliminary Report)

The recently released Supplemental Directive, NA-1 SD 1027, updates the radionuclide threshold values in DOE-STD-1027-92 CN1 to reflect the use of modern parameters for dose conversion factors and breathing rates. The directive also corrects several arithmetic errors within the original standard. The result is a roughly four-fold increase in the amount of weapons-grade nuclear material allowed within a designated radiological facility. Radiological laboratory space within the recently constructed Radiological Laboratory Office and Utility Building (RLUOB) is slated to house selected analytical chemistry support activities in addition to small-scale actinide R&D activities. RLUOB is within the same facility operations envelope as TA-55. Consolidation of analytical chemistry activities to RLUOB and PF-4 offers operational efficiency improvements relative to the current pre-CMRR plans of dividing these activities between RLUOB, PF-4, and CMR. RLUOB is considered a Radiological Facility under STD-1027 - 'Facilities that do not meet or exceed Category 3 threshold criteria but still possess some amount of radioactive material may be considered Radiological Facilities.' The supplemental directive essentially increases the allowable material-at-risk (MAR) within radiological facilities from 8.4 g to 38.6 g for 239 Pu. This increase in allowable MAR provides a unique opportunity to establish additional analytical chemistry support functions in RLUOB without negatively impacting either R&D activities or facility operations. Individual radiological facilities are tasked to determine MAR limits (up to the Category 3 thresholds) appropriate to their operational conditions. This study presents parameters that impact establishing MAR limits for RLUOB and an assessment of how various analytical chemistry support functions could operate within the established MAR limits.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessing the hygrothermal performance of bio-based materials in building wall systems

Building envelope systems are crucial in regulating thermal and moisture exchange between interior and exterior environments, accounting for approximately 28 % of building energy consumption in the United States with walls being the primary contributors. Improper selection of building envelope materials can lead to moisture-related issues, reduced resilience, and compromised durability. Hygrothermal performance assessment is a key factor in efficient building design. As such, improving the energy and hygrothermal performance of opaque wall materials, through careful assessment of material choices, is essential to enhancing building resilience, lowering energy costs, and improving occupant comfort. As the building industry seeks new strategies to reduce material energy intensity, bio-based materials emerge as a promising solution. However, their long-term hygrothermal performance in building envelope systems remains underexplored. To fill this gap, this study evaluates the hygrothermal behavior of 13 bio-based materials in residential wall systems across three U.S. climate zones. Laboratory experiments were performed to measure material properties such as density, thermal conductivity, moisture transmission, and sorption isotherms. These data were integrated into the WUFI® simulation tool to assess wall hygrothermal performance in Houston, Baltimore, and Chicago. A three-phase modeling approach was used: (1) baseline residential walls with oriented strand board (OSB) and gypsum board; (2) replacing OSB with bio-based materials; and (3) replacing drywall with bio-based materials. Results showed that the evaluated bio-based materials maintained acceptable moisture thresholds of ≤ 16 % across all climates, confirming their viability as an alternative for current sheathing materials. Furthermore, this study provides a foundation for future research and innovation in material science on the use of certain bio-based materials in high-performance, low energy use residential construction. Ultimately, providing critical data, offering a database of bio-based material properties, and supplying a simulation-based approach will help designers make informed decisions for future efficient building practices.

Bio-based materials↗

Impact of Protostellar Outflows on Turbulence and Star Formation Efficiency in Magnetized Dense Cores

The star-forming efficiency of dense gas is thought to be set within cores by outflow and radiative feedback. We use magnetohydrodynamic simulations to investigate the relation between protostellar outflow evolution, turbulence, and star formation efficiency. We model the collapse and evolution of isolated dense cores for ≳0.5 Myr including the effects of turbulence, radiation transfer, and both radiation and outflow feedback from forming protostars. We show that outflows drive and maintain turbulence in the core environment even with strong initial fields. The star formation efficiency decreases with increasing field strength, and the final efficiencies are 15%–40%. The Stage 0 lifetime, during which the protostellar mass is lower than that of the dense envelope, increases proportionally with the initial magnetic field strength and ranges from ∼0.1 to 0.4 Myr. The average accretion rate is well represented by a tapered turbulent core model, which is a function of the final protostellar mass and is independent of the magnetic field strength. By tagging material launched in the outflow, we demonstrate that the outflow entrains about three times the actual launched gas mass, a ratio that remains roughly constant in time regardless of the initial magnetic field strength. However, turbulent driving increases for stronger fields since momentum is more efficiently imparted to non-outflow material. The protostellar outflow momentum is highest during the first 0.1 Myr and declines thereafter by a factor of ≳10 as the accretion rate diminishes.

79 ASTRONOMY AND ASTROPHYSICS↗

Model-based, in-situ, non-destructive qualification and certification of parts made by autonomous additive manufacturing

To address the significant productivity challenges associated with the qualification and certification (Q&C) tasks of additively manufactured (AM) parts, which have traditionally relied on rigorous post‐build inspection and testing, we propose an integrated framework that combines model‐based qualification and certification (MBQ&C) with autonomous additive manufacturing (AAM). MBQ&C employs high‐fidelity predictive models, developed within the Integrated Computational Materials Engineering (ICME) paradigm, to simulate process–structure–property–performance relationships for assessing a part’s fitness for use. Since predictive models are commonly machine learning (ML)-based or reduced-order surrogates of validated physics models, they run efficiently, enabling timely inference. In parallel, the self-driving AAM utilises ML-based adaptive, closed‐loop control strategies to avoid, mitigate, or repair defects and anomalies during fabrication, thereby increasing the likelihood of producing acceptable parts. A key feature of the combined AAM-MBQ&C framework is that predictive models explicitly incorporate defects or anomalies that persist after the build, using instance-specific data captured via in-situ sensing. This customisation enables a build‐specific assessment of fitness for use, rather than relying on nominal or generic parameters. Such individualised evaluation provides a robust basis for Q&C-related acceptance decisions relating to each build. Additionally, the rapid solution capabilities of ML or reduced-order models enable the determination of a part’s suitability for service shortly after build completion. As the framework matures, it has the potential to substantially reduce reliance on conventional point‐design approaches—such as time‐consuming post‐build computed tomography scanning and costly destructive testing. Thus, the AAM-MBQ&C framework represents a transformative, scalable strategy for quality assurance of AM components, as parts produced within a stable, validated, and certified envelope can be certified with reduced testing. Key benefits include: (1) significant gains in Q&C productivity through efficient, model-centric assessment; (2) performance-based classification of defects into critical and non-critical categories; (3) the ability to predict potential deviations in the performance of parts affected by real-time, adaptive process control interventions relative to those produced under a certified process, and (4) the enabling of virtual Q&C for service environments that are difficult, hazardous, or impractical to access or reproduce experimentally. Collectively, these capabilities strengthen the business case for AM, particularly for high‐consequence and mission‐critical applications. Finally, although this work focuses on powder-based AM, the proposed techniques could be extended to AM processes employing alternative feedstock forms.

Gunasegaram, Dayalan↗