Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron linac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Ultrafast Relaxation of MLCT Excited States in Manganese Tricarbonyl Complexes: Insights from Polarization-Resolved Femtosecond X-ray Absorption Spectroscopy at the Mn and Br K-Edges

Optical absorption features that are often described as metal-to-ligand charge transfer (MLCT) bands underlie the utility of many metal coordination complexes by harnessing the energy of light to drive otherwise inaccessible chemical reactions. Excitation of these bands triggers rapid electronic dynamics that can be challenging to understand, due to complicated potential energy landscapes and highly correlated electronic and nuclear degrees of freedom in metal-containing compounds. The lowest-energy absorption bands in Mn complexes containing alpha-diimine, carbonyl, and halide ligands are particularly interesting, due to the delocalized nature of charge transfer upon excitation. Here, in this study, we report experimental ultrafast dynamics measurements for the series of compounds Mn­(CO) 3 ( R bpy)Br ( R bpy = 4,4′-disubstituted-2,2′-bipyridine; R = H, CF 3 , or NO 2 ) using polarization-resolved, femtosecond X-ray absorption spectroscopy (XAS) at both the Mn and Br K edges. The appearance of a new absorption feature in the Br pre-edge spectrum upon optical excitation reveals the instantaneous formation of an electronic hole that is partially localized on the Br atom and has a lifetime that depends on the electron withdrawing character of the R bpy ligand. For two of the complexes (R = H or CF 3 ), a large expansion of the Mn–Br distance results in a rapid redistribution of the hole and a corresponding decrease in anisotropy of the absorption feature within 50 fs, after which the absorption into the hole disappears on a time scale shorter than 300 fs. We observe a different result for the NO 2 substituted compound, for which the Mn–Br bond contracts and the absorption into the Br-centered hole persists beyond the 2 ps time scale of our measurement. The Mn pre-edge spectrum also reveals structural changes for these three complexes, but the new Mn absorption features become evident only after the nuclei respond to the initial excitation, which allows mixing of Mn 3d and 4p orbitals. The combined use of ultrafast Mn and Br K-edge spectroscopy provides unique insight into the ways in which bipyridine substitution alters the excited-state dynamics, including a very different structural response for the most strongly electron withdrawing substituent.

Otolski, Christopher J. [Univ. of Kansas, Lawrence↗

Manufacturing Full-Scale High Gradient Copper Accelerators: Electron Beam Welding and Allied Processes

This DOE ARDAP-funded study examines the technical and business feasibility of manufacturing high-gradient normal conducting RF (NCRF) copper accelerating structures using electron beam welding (EBW) instead of conventional high-temperature brazing. The core motivation is material performance: brazing softens copper significantly, while hard copper alloys have demonstrated ~75% higher operational gradients in SLAC tests, making cold-joining techniques highly attractive. EBW, applied to split-cell (half or quadrant) structure designs, preserves copper hardness away from the weld joint and simplifies machining — but industrial process optimization remains immature and a substantial learning curve is expected. The business case was modeled for two scenarios: a greenfield EBW linac company (> $10M upfront costs, viable above ~30 units/year) and an EBW division added to an existing accelerator firm to reduce risk and upfront costs, at the expense of being less optimal structure for the higher volume production. The study concludes that without a significant increase in demand, private investment alone cannot sustain this capability, and recommends federal support through R&D grants, procurement incentives, and CAPEX cost-sharing to incubate domestic EBW-NCRF manufacturing — with the existing-company model.

43 PARTICLE ACCELERATORS↗

Nonadiabatic dynamics of photoexcited thiopyridone isomers: An interplay between El-Sayed’s conditions and energy gap law

We investigated the non-adiabatic dynamics of photoexcited thiopyridone systems across their ortho-, meta-, and para-isomeric forms. The relaxation pathways of the three isomers in both gas phase and solvent environments are mapped using surface hopping dynamics based on time-dependent density functional theory. Our analysis highlights the influence of isomeric structures on photophysical behavior, offering insights into design principles to control photochemical phenomena. The simulations suggest a systematic reduction in the rate of intersystem crossing (ISC) from ortho- to meta- to para-isomer. Comparisons with multiconfigurational wave function methods in the gas phase further demonstrate how electronic structure influences the predicted dynamical pathways. The simulated dynamics demonstrates that the spin–orbit coupling strength alone does not determine the rate of ISC, as both state energetics and underlying electronic and structural features play decisive roles. These aspects explain the much slower ISC in the para-isomer, as well as the non-negligible role of the El-Sayed forbidden pathway in the computed ISC dynamics.

Complete-active space self-consistent field↗

Attosecond inner-shell lasing at ångström wavelengths

Since the invention of the laser, nonlinear effects such as filamentation, Rabi cycling and collective emission have been explored in the optical regime, leading to a wide range of scientific and industrial applications. X-ray free-electron lasers (XFELs) have extended many optical techniques to X-rays for their advantages of ångström-scale spatial resolution and elemental specificity. An example is XFEL-driven inner-shell Kα 1 (2p 3/2 → 1s 1/2 ) X-ray lasing in elements ranging from neon to copper, which has been used for nonlinear spectroscopy and development of new X-ray laser sources. Here, in this study, we show that strong lasing effects similar to those in the optical regime can occur at 1.5–2.1 Å wavelengths during high-intensity (>10 19 W cm −2 ) XFEL-driven Kα 1 lasing of copper and manganese. Depending on the temporal XFEL pump pulse substructure, the resulting X-ray pulses (about 10 6 −10 8 photons) can exhibit strong spatial inhomogeneities and spectral splitting, inhomogeneities and broadening. Three-dimensional Maxwell–Bloch calculations show that the observed spatial inhomogeneities result from X-ray filamentation and that the broad spectral features are driven by sub-femtosecond Rabi cycling. Our simulations indicate that these X-ray pulses can have pulse lengths of less than 100 attoseconds and coherence properties that provide opportunities for quantum X-ray optics applications.

47 OTHER INSTRUMENTATION↗

Revealing Parallel Inter‐ and Intra‐Ligand Charge Transfer Dynamics in [Ru(L) 2 (dppz)] 2+ Molecular Lightswitch with N K‐Edge X‐Ray Absorption Spectroscopy

In photoactive metal complexes the localization of photoexcited charges dictates the site of chemical reactivity, but few studies measure the charge redistribution in these systems with spatial precision. Herein, we track the inter- and intra-ligand charge transfer processes that underpin light-driven charge separation in the well-studied “molecular lightswitch” [Ru(bpy) 2 dppz] 2+ (aqueous [Ruthenium II (2,2′-bipyridine)2(dipyrido[3,2-a:2′,3′-c]phenazine)] 2+ [Cl − ] 2 ) by probing the electronic structure of ligand nitrogen atoms in real-time using ultrafast X-ray absorption spectroscopy and first principles calculations. We confirm the localization of excited electron density on the phenazine N atoms of dppz and we newly identify two parallel electron transfer pathways to populate this state. Sub-70 fs electron transfer to the phenazine portion of dppz is observed and attributed to intra-ligand electron transfer following Ru-to-dppz metal-to-ligand charge transfer (MLCT) excitation. This fast charge transfer was not reported in prior ultrafast studies. The slower (ca. 2 ps) charge transfer reported extensively in time-resolved optical absorption and emission studies is reassigned here to inter-ligand electron “hopping” between nearly isoenergetic ligand moieties following Ru-to-bpy MLCT excitation. In conclusion, the results demonstrate much faster charge separation than previously identified in this well-studied system, highlighting how extended azaacene ligand motifs promote the competitive charge transfer processes needed to drive light-driven electron transfer chemistry.

Donor-acceptor systems↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Optimization of an electron injector for operating high-intensity polarized electron beam

In this work, the simulation and optimization of an electron injector that operates a high-intensity polarized electron beam are presented. The electron injector would provide a single-bunch electron beam at a repetition rate of 1 Hz with a bunch charge of 10 nC, kinetic energy of 400 MeV and an electron spin polarization of 85%. A direct current (DC) high-voltage photogun was employed to produce the 10 nC polarized electron beam with a kinetic energy of 350 keV, beam diameter of 1.44 cm (Gaussian distribution with σ of 0.36 cm) and full bunch length of 1.3 ns (Gaussian distribution with σ of 0.325 ns). The beam was compressed to 6 ps of RMS bunch length using one 114.24 MHz standing-wave sub-harmonic buncher, two 571.2 MHz standing-wave sub-harmonic bunchers and one 2.856 GHz traveling-wave buncher. The beam was accelerated finally to 400 MeV via eight 2.856 GHz traveling-wave Linacs. We performed the beam simulation, and the simulated results showed that the optimized RMS bunch length was 4.65 ps, RMS relative energy spread was 0.48% and normalized RMS transverse emittance was 30.13 mm · mrad at a beam energy of 400 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a Platform at the Matter in Extreme Conditions End Station for Characterization of Matter Heated by Intense Laser-Accelerated Protons

High intensity short-pulse lasers have made possible the generation of energetic proton beams, unlocking numerous applications in high energy density science. One such application is uniform and isochoric heating of materials to the warm dense matter (WDM) state. We have developed a new experimental platform to simultaneously create and probe warm dense matter at the Matter in Extreme Conditions (MEC) end station at the Linac Coherent Light Source (LCLS). The short pulse optical laser (delivering up to 1 J in 45 fs) and the ultra-bright LCLS x-ray laser with tunable frequency respectively deliver high power required to heat materials to WDM and precision-timed high-resolution x-rays to probe them. The laser-accelerated proton beam driven from a flat 1.5 μm Cu foil was first measured then directed to a secondary sample of Al or polypropylene, typically 300-400 μm away. The time evolution of the sample electron temperature was measured using streaked optical pyrometry, where we observed a peak temperature of 0.9 0.15 eV on the rear surface of an Al sample heated by the proton beam. Here, the simulations using the hybrid-PIC code LSP and the rad-hydro code HELIOS show that a measured proton beam can heat Al to approximately 4 eV and polypropylene to 1 eV if instead focused by a hemispherical Cu target. Through additional LSP simulations, we anticipate creating hotter warm dense matter states (20 eV) by increasing the laser energy to 10 J and keeping the other laser parameters fixed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerators for Electroweak Physics and Higgs Boson Studies

We discuss the goals, the designs, the state of technical readiness, and the critical R&D needs of the accelerators that are currently under discussion as Higgs and electroweak factories. We also address the respective staging options enabling future energy-frontier colliders. The accelerators covered are based on many different techniques and approaches. They include several circular colliders, various linear colliders, colliders based on energy recovery linacs (ERLs), ERL-ring combinations, as well as γγ colliders. The linear colliders proposed consist of options for the International Linear Collider (ILC), for the Compact Linear Collider (CLIC), for the Cold Copper Collider (C 3 ), and for the more recent Higgs-Energy Lepton Collider (HELEN). ERLs are key components of the Recycling Linear e + e - Collider (ReLiC),of the Energy Recovery Linear Collider (ERLC), and of the Circular Energy Recovery Collider (CERC). Among the more conventional ring colliders the following proposals are featured: the Future Circular Collider (FCC-ee), the Circular Electron Positron Collider (CEPC), the Electron Positron Circular Collider at Fermilab (EPCCF), and the Large Electron Positron collider #3 (LEP-3). In addition, we consider the X-ray FEL based gamma- gamma Collider Higgs Factory (XCC) and the High-Energy High-Luminosity γ-γ collider (HE&HL γγ). Finally, a Higgs factory based on a circular muon collider is mentioned for completeness.

43 PARTICLE ACCELERATORS↗

Demonstration of an intense lithium beam for forward-directed pulsed neutron generation

Abstract As an alternative to research nuclear reactors, a compact accelerator-driven neutron generator that uses a lithium beam driver could be a promising candidate since it produces almost no undesired radiation. However, providing an intense lithium-ion beam has been difficult, and it has been thought that the practical application of such a device would be impossible. The most critical problem of insufficient ion fluxes has been solved by applying a direct plasma injection scheme. In this scheme, a pulsed high-density plasma from a metallic lithium foil generated by laser ablation is efficiently injected and accelerated by a radio-frequency quadrupole linear accelerator (RFQ linac). We have obtained a peak beam current of 35 mA accelerated to 1.43 MeV, which is two orders of magnitude higher than a conventional injector and accelerator system can deliver.

43 PARTICLE ACCELERATORS↗

Towards performing high-resolution inelastic X-ray scattering measurements at hard X-ray free-electron lasers coupled with energetic laser drivers

High-resolution inelastic X-ray scattering is an established technique in the synchrotron community, used to investigate collective low-frequency responses of materials. When fielded at hard X-ray free-electron lasers (XFELs) and combined with high-intensity laser drivers, it becomes a promising technique for investigating matter at high temperatures and high pressures. This technique gives access to important thermodynamic properties of matter at extreme conditions, such as temperature, material sound speed, and viscosity. The successful realization of this method requires the acquisition of many identical laser-pump/X-ray-probe shots, allowing the collection of a sufficient number of photons necessary to perform quantitative analyses. Here, a 2.5-fold improvement in the energy resolution of the instrument relative to previous works at the Matter in Extreme Conditions (MEC) endstation, Linac Coherent Light Source (LCLS), and the High Energy Density (HED) instrument, European XFEL, is presented. Some aspects of the experimental design that are essential for improving the number of photons detected in each X-ray shot, making such measurements feasible, are discussed. A careful choice of the energy resolution, the X-ray beam mode provided by the XFEL, and the position of the analysers used in such experiments can provide a more than ten-fold improvement in the photometrics. The discussion is supported by experimental data on 10 µm-thick iron and 50 nm-thick gold samples collected at the MEC endstation at the LCLS, and by complementary ray-tracing simulations coupled with thermal diffuse scattering calculations.

36 MATERIALS SCIENCE↗

DAMSA Experiment Conceptual Design White Paper

DAMSA (DArk Messenger Searches at an Accelerator) is a novel short-baseline accelerator experiment aimed at probing short-lived physics processes, including searches for evidence of a dark sector of particle physics and well-motivated Standard Model signals. Motivated by open questions in neutrino physics and the absence of conclusive evidence for conventional weakly interacting massive particles, DAMSA targets MeV-to-sub-GeV dark-sector messengers with feeble couplings that can be produced in abundance at the PIP-II LINAC. By employing an ultra-short baseline of order one meter, DAMSA is uniquely positioned to overcome the beam-dump "ceiling" that limits sensitivity to promptly decaying particles in longer-baseline experiments. The conceptual design emphasizes a beam-dump production scheme combined with a compact detector optimized for rare decays while mitigating intense neutron-induced backgrounds inherent to high-power proton beams. To validate the experimental strategy and detector technologies, the Little DAMSA Path-Finder (LDPF) proof-of-concept experiment is proposed, focusing on axion-like particles decaying to two photons and operating with 300 MeV electron beams at FAST. Successful realization of LDPF will establish the feasibility of the DAMSA approach, enabling a broad and powerful program to explore short-lived new physics and precision Standard Model processes in a previously inaccessible regime. This conceptual design document outlines the technical details of DAMSA's physics goals, the beam facility proposals, key experimental challenges and how to overcome them, and the proposed experimental staging campaigns.

Bhattarai, Prithak [Texas U., Arlington]↗

RF Technologies for Future Colliders

Particle colliders remain indispensable scientific instruments to discover and study new elementary particles and fundamental forces of nature. Whether the collider is a factory (used to improve precision of measuring properties of already discovered particles or to enable studies of rare decay channels), an energy frontier machine (aimed at discovering new particles and forces), a heavy ion collider (allowing studies of what the universe looked like in the early moments after its creation), or an electron-hadron collider (where electrons are used for probing heavy ions or protons to study the fundamental force binding all visible matter), the radio frequency technologies play a key role in enabling the machine to reach its goals. This article considers challenges presented to the radio frequency technologies by the next generation of particle colliders and reviews R&D approaches and directions to address these challenges.

43 PARTICLE ACCELERATORS↗

Tunable x-ray free electron laser multi-pulses with nanosecond separation

X-ray Free Electron Lasers provide femtosecond x-ray pulses with narrow bandwidth and unprecedented peak brightness. Special modes of operation have been developed to deliver double pulses for x-ray pump, x-ray probe experiments. However, the longest delay between the two pulses achieved with existing single bucket methods is less than 1 picosecond, thus preventing the exploration of longer time-scale dynamics. We present a novel two-bucket scheme covering delays from 350 picoseconds to hundreds of nanoseconds in discrete steps of 350 picoseconds. Performance for each pulse can be similar to the one in a single pulse operation. The method has been experimentally tested with the Linac Coherent Light Source (LCLS-I) and the copper linac with LCLS-II hard x-ray undulators.

47 OTHER INSTRUMENTATION↗

Recent H - ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced from spallation of liquid Hg by bombardment of short (~1 μs), intense (~35 A) pulses of protons delivered at 60 Hz by a storage ring which is fed by a high-intensity, ~1 GeV H - LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50–60 mA of H - ions with a duty-factor of 6% for maintenance-free runs of several months with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting this success: this report provides an update on some of the ongoing ion source research and development efforts which have been undertaken since the previous Negative Ion Beams and Sources (NIBS) conference in 2020. These include significant improvements to H - beam current by extraction from a larger source outlet aperture and improvements to the electron dumping system which should eliminate the gradual loss of electrode voltage over the course of a run which has occasionally impacted SNS operations. Improvement and simplification of the plasma ignition system for the external antenna ion source, a long-standing problem, was also realized. Lastly, RF coupling efficiency was measured for both the SNS internal and external antenna ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R&D toward design for a pion-production target for Mu2e-II

The Mu2e experiment at Fermilab will search for evidence of charged lepton flavor violation by observing the conversion of a negative muon into an electron in the Coulomb field of a nucleus without emission of neutrinos and will probe effective new-physics mass scales in the 103-104 TeV range. One of the main parts of the Mu2e experimental setup is its target station in which negative pions are generated in interactions of the 8 GeV primary proton beam with a tungsten target, which will be capable of producing $2\times10^{17}$ negative muons per year. Mu2e can be extended by a next generation experiment, Mu2e-II, with a sensitivity improved by another factor of 10 or more as enabled by the PIP-II accelerator upgrade project. PIP-II is a 250-meter-long linac capable of accelerating a 2 mA proton beam to a kinetic energy of 800 MeV corresponding to 1.6 MW of power. To achieve another factor of ten improvement in sensitivity, Mu2e-II will require about 100 kW of proton beam on target, and the added power requires a new target design. We will present our progress in RD of a target station conceptual design for Mu2e-II, using the MARS15 and G4beamline Monte-Carlo codes toward a selection between granular, conveyor, and rotating cylindrical target options.

Lynch, Kevin Richard↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

Beam Profile Measurements Utilizing an Amplitude Modulated Pulsed Fiber Laser at PIP2IT

Fermilab is undertaking the development of a new 800 MeV superconducting RF linac to replace its present normal conducting 400 MeV linac. The PIP-II linac consists of a warm front-end generating 2 mA of 2.1 MeV H⁻ followed immediately by a series of superconducting RF cryomodules to 800 MeV. To limit the potential damage to the superconducting RF cavities, PIP-II will utilize laser-based monitors to obtain beam profiles via photoionization. This paper will present the results of transverse and longitudinal beam profile measurements using a prototype profile monitor that was tested with 2.1 MeV H⁻ beam at the PIP-II Injector Test (PIP2IT) accelerator. This prototype profile monitor utilizes a high repetition rate fiber laser and fiber optic transport into the PIP2IT enclosure. In addition, results will be shown of narrow-band electron detection from amplitude modulated laser pulses.

43 PARTICLE ACCELERATORS↗