Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

SU-F-BRA-09: New Efficient Method for Xoft Axxent Electronic Brachytherapy Source Calibration by Pre-Characterizing Surface Applicators

Purpose: The objective is to improve the efficiency and efficacy of Xoft™ Axxent™ electronic brachytherapy (EBT) calibration of the source & surface applicator using AAPM TG-61 formalism. Methods: Current method of Xoft EBT source calibration involves determination of absolute dose rate of the source in each of the four conical surface applicators using in-air chamber measurements & TG61 formalism. We propose a simplified TG-61 calibration methodology involving initial characterization of surface cone applicators. This is accomplished by calibrating dose rates for all 4 surface applicator sets (for 10 sources) which establishes the “applicator output ratios” with respect to the selected reference applicator (20 mm applicator). After the initial time, Xoft™ Axxent™ source TG61 Calibration is carried out only in the reference applicator. Using the established applicator output ratios, dose rates for other applicators will be calculated. Results: 200 sources & 8 surface applicator sets were calibrated cumulatively using a Standard Imaging A20 ion-chamber in accordance with manufacturer-recommended protocols. Dose rates of 10, 20, 35 & 50mm applicators were normalized to the reference (20mm) applicator. The data in Figure 1 indicates that the normalized dose rate variation for each applicator for all 200 sources is better than ±3%. The average output ratios are 1.11, 1.02 and 0.49 for the 10 mm,35 mm and 50 mm applicators, respectively, which are in good agreement with the manufacturer’s published output ratios of 1.13, 1.02 and 0.49. Conclusion: Our measurements successfully demonstrate the accuracy of a new calibration method using a single surface applicator for Xoft EBT sources and deriving the dose rates of other applicators. The accuracy of the calibration is improved as this method minimizes the source position variation inside the applicator during individual source calibrations. The new method significantly reduces the calibration time to less than one third of the current calibration time while improving efficacy.

60 APPLIED LIFE SCIENCES↗

The Jefferson lab FEL driver ERLs

Jefferson Lab has - for over a decade - been operating high power IR and UV FELs using CW energy recovering linacs based on DC photocathode electron sources and CEBAF SRF technology. These machines have unique combinations of beam quality, power, and operational flexibility, and thus offer significant opportunity for experiments that use low and medium energy (several tens - few hundreds of MeV) electron beams. We will describe the systems and detail their present and near-term (potential) performance. Recent internal-target analysis and validation testing will be discussed, and schemes for single- and two-pass fixed target operation described. An introduction to subsequent discussions of beam quality and upgrade paths to polarized operation/higher energy will be given.

43 PARTICLE ACCELERATORS↗

Influence of Carbon Sources and Electron Shuttles on Ferric Iron Reduction by Cellulomonas sp. Strain ES6

The reduction of hexavalent chromium, Cr(VI), to trivalent chromium, Cr(III), can be an important aspect of remediation processes at Department of Energy (DOE) and other contaminated sites. Cellulomonas species are found at several Cr(VI) contaminated and uncontaminated locations at the DOE site in Hanford, Washington. Members of this genus have demonstrated the ability to effectively reduce Cr(VI) to Cr(III) fermentatively and therefore play a potential role in hexavalent chromium remediation at this site. Batch studies were conducted with Cellulomonas sp. strain ES6 to assess the influence of various carbon sources, iron minerals, and electron shuttling compounds on Cr(VI) reduction. These chemical species are likely to be present in these terrestrial environments during in situ bioremediation. Results indicated that there were a number of interactions between these compounds that influenced Cr(VI) reduction rates. The type of carbon source as well as the type of electron shuttle present influenced Cr(VI) reduction rates. When an electron shuttle, such as anthraquinone-2,6-disulfonate (AQDS), was present in the system, reduction rates increased significantly. Biologically reduced AQDS (AHDS) reduced Cr(VI) almost instantaneously. The presence of iron minerals and their concentrations did not significantly influence Cr(VI) reduction rates. However, strain ES6 or AQDS could directly reduce surface-associated Fe(III) to Fe(II) which was capable of reducing Cr(VI) at a near instantaneous rate. These results suggest the rate limiting step in these systems is the transfer of electrons from strain ES6 to the intermediate or terminal electron acceptor whether that is Cr(VI), Fe(III), or AQDS.

60 APPLIED LIFE SCIENCES↗

Nanoscale electromechanical parametric amplifier

This disclosure provides systems, methods, and apparatus related to a parametric amplifier. In one aspect, a device includes an electron source electrode, a counter electrode, and a pumping electrode. The electron source electrode may include a conductive base and a flexible conductor. The flexible conductor may have a first end and a second end, with the second end of the flexible conductor being coupled to the conductive base. A cross-sectional dimension of the flexible conductor may be less than about 100 nanometers. The counter electrode may be disposed proximate the first end of the flexible conductor and spaced a first distance from the first end of the flexible conductor. The pumping electrode may be disposed proximate a length of the flexible conductor and spaced a second distance from the flexible conductor.

42 ENGINEERING↗

MeRHIC - staging approach to eRHIC

Design of a medium energy electron-ion collider (MeRHIC) is under development at the Collider-Accelerator Department at BNL. The design envisions construction of a 4 GeV electron accelerator in a local area inside and near the RHIC tunnel. Electrons will be produced by a polarized electron source and accelerated in energy recovery linacs. Collisions of the electron beam with 100 GeV/u heavy ions or with 250 GeV polarized protons will be arranged in the existing IP2 interaction region of RHIC. The luminosity of electron-proton collisions at the 10{sup 32} cm{sup -2}s{sup -1} level will be achieved with 50 mA CW electron current and presently available proton beam parameters. Efficient proton beam cooling at collision energy may bring the luminosity to 10{sup 33} cm{sup -2}s{sup -1}. An important feature of MeRHIC is that it serves as a first stage of eRHIC, a future electron-ion collider at BNL with both higher luminosity and energy reach. The majority of MeRHIC accelerator components will be used in eRHIC.

43 PARTICLE ACCELERATORS↗

Commissioning of the Low Energy Electron Gun Test Stand at the University of Chicago

We built a test stand for evaluating the performance of the thermionic electron sources for the electron lens project at the Integrable Optics Test Accelerator (IOTA) in Fermilab. The lens will be used to study nonlinear dynamics and electron cooling of 2.5 MeV protons with strong space charge. The test stand will validate the characteristics of the thermionic sources and the main parameters of the generated beams. In this paper we present the results of the commissioning of the UChicago test stand and validation of the hollow beam source.

43 PARTICLE ACCELERATORS↗

A model for quantitative correction of coronary calcium scores on multidetector, dual source, and electron beam computed tomography for influences of linear motion, calcification density, and temporal resolution: A cardiac phantom study

Purpose: The objective of this study is to quantify the influence of linear motion, calcification density, and temporal resolution on coronary calcium determination using multidetector computed tomography (MDCT), dual source CT (DSCT), and electron beam tomography (EBT) and to find a quantitative method which corrects for the influences of these parameters using a linear moving cardiac phantom. Methods: On a robotic arm with artificial arteries with four calcifications of increasing density, a linear movement was applied between 0 and 120 mm/s (step of 10 mm/s). The phantom was scanned five times on 64-slice MDCT, DSCT, and EBT using a standard acquisition protocol. The average Agatston, volume, and mass scores were determined for each velocity, calcification, and scanner. Susceptibility to motion was quantified using a cardiac motion susceptibility (CMS) index. Resemblance to EBT and physical volume and mass was quantified using a {Delta} index. Results: Increasing motion artifacts were observed at increasing velocities on all scanners, with increasing severity from EBT to DSCT to 64-slice MDCT. The calcium score showed a linear dependency on motion from which a correction factor could be derived. This correction factor showed a linear dependency on the mean calcification density with a good fit for all three scoring methods and all three scanners (0.73{<=}R{sup 2}{<=}0.95). The slope and offset of this correction factor showed a linear dependency on temporal resolution with a good fit for all three scoring methods and all three scanners (0.83{<=}R{sup 2}{<=}0.98). CMS was minimal for EBT and increasing values were observed for DSCT and highest values for 64-slice MDCT. CMS was minimal for mass score and increasing values were observed for volume score and highest values for Agatston score. For all densities and scoring methods DSCT showed on average the closest resemblance to EBT calcium scores. When using the correction factor, CMS index decreased on average by 15% and {Delta} index decreased by 35%. Conclusions: Calcium scores determined on DSCT and 64-slice MDCT are highly susceptible to motion as compared to EBT. The mass score is less susceptible to motion compared to volume and Agatston score. Calcium scores determined on DSCT bear a closer resemblance to EBT obtained calcium scores than 64-slice MDCT. In addition, the calcium score is highly dependent on the average density of individual calcifications and the dependency of the calcium score on motion showed a linear behavior on calcification density. From these relations, a quantitative method could be derived which corrects the measured calcium score for the influence of linear motion, mean calcification density, and temporal resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The FERMI@Elettra free-electron-laser source for coherent X-ray physics: photon properties, beam transport system, and applications

FERMI@Elettra is comprised of two free electron lasers (FELs) that will generate short pulses (tau ~;; 25 to 200 fs) of highly coherent radiation in the XUV and soft X-ray region. The use of external laser seeding together with a harmonic upshift scheme to obtain short wavelengths will give FERMI@Elettra the capability to produce high quality, longitudinal coherent photon pulses. This capability together with the possibilities of temporal synchronization to external lasers and control of the output photon polarization will open new experimental opportunities not possible with currently available FELs. Here we report on the predicted radiation coherence properties and important configuration details of the photon beam transport system. We discuss the several experimental stations that will be available during initial operations in 2011, and we give a scientific perspective on possible experiments that can exploit the critical parameters of this new light source.

36 MATERIALS SCIENCE↗

Design of the injection beamline for the Californium Rare Isotope Breeder Upgrade electron beam ion source charge breeder

The design of the ion injection line connecting the electron beam ion source (EBIS) charge breeder and the Californium Rare Isotope Breeder Upgrade radio frequency quadrupole cooler-buncher at the Argonne Tandem Linear Accelerator System was investigated with particle tracking simulations. The injection line was configured to accommodate several differential pumping sections, individual optical components were optimized to minimize emittance growth, and the ion beam parameters were matched with the EBIS electron beam acceptance to minimize losses upon injection.

43 PARTICLE ACCELERATORS↗

Neutralization of ion beam by electron injection: Accumulation of cold electrons

Ion beam charge neutralization by electron injection is a complex kinetic process. Recent experiments show that the resulting self-potential of the ion beam after neutralization by plasma is much lower than the temperature of plasma electrons [Stepanov et al., Phys. Plasmas 23, 043113 (2016)], indicating that kinetic effects are important and may affect the neutralization of the ion beam. We performed a numerical study of the charge neutralization process of an ion beam making use of a two-dimensional electrostatic particle-in-cell code. The results show that the process of charge neutralization by electron injection is composed of two stages. During the first stage, the self-potential of the beam is higher than the temperature of injected electrons (T e /e) and all injected electrons are captured by the ion beam. During the second stage, hot electrons escape from the ion beam and the beam self-potential (φ) decreases because cold electrons slowly accumulate resulting in the beam self-potential φ to become much lower than Te/e in agreement with previous experimental observations at Princeton Advanced Teststand. We also determined that the resulting φ scales as φ~√T e , in agreement with previous experimental observations from Gabovich's group. In addition, the results show that the transverse position of the electron source has a great impact on ion beam neutralization. A slight shift of the electron source as relevant to the ion thrusters leads to a large increase in the beam self-potential because of an increase in potential energy of injected electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation of longitudinal nonlinear structures in the electron cloud of an electron-string ion source

Accumulation of oscillating electrons in an electron-string ion source is simulated by the particle-in-cell method. The electrons are accumulated in a long trap into which an electron beam is injected. It is shown that a chain of alternating phase holes and squeezed states forms in the trap. The dynamical features of such a longitudinal structure, such as the double-pulse waveform and strong high-frequency oscillations of the accumulation current and the broadening of the electron distribution function, are qualitatively similar to those previously observed in experiments with the Krion-2 ion source operating in the electron-string mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Miniature electrostatic electron energy analyzers and S-shaped deflector

An instrument has been developed to avoid the rotation of large electron sources and detectors in quantum single particle scattering experiments. The rotation of an electron beam has been achieved by combining three small cylindrical electrostatic electron energy analyzers in series such that the first analyzer is fixed and the other two rotate together around the exit axis of the first; it is a development from an S-shaped deflector used by Hegemann et al. [J. Phys. B 26, 4607 (1993)]. Novel design and construction, using copper, aluminum, and stainless steel parts mounted on polyvinyl printed circuit board, enabled an efficient, small-sized high vacuum compatible instrument. The characteristics and versatility of the instrument have been shown by measurements of angular and spin asymmetries of electron scattering phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarized electron beams at milliampere average current

This contribution describes some of the challenges associated with developing a polarized electron source capable of uninterrupted days-long operation at milliAmpere average beam current with polarization greater than 80%. Challenges will be presented in the context of assessing the required level of extrapolation beyond the performance of today’s CEBAF polarized source operating at ∼ 200 uA average current. Estimates of performance at higher current will be based on hours-long demonstrations at 1 and 4 mA. Particular attention will be paid to beam-related lifetime-limiting mechanisms, and strategies to construct a photogun that operate reliably at bias voltage > 350kV.

43 PARTICLE ACCELERATORS↗

Some plasma aspects and plasma diagnostics of ion sources (invited)

We consider plasma properties in the most advanced type of plasma ion sources, electron cyclotron resonance ion sources for highly charged ions. Depending on the operation conditions the plasma in these sources may be highly ionized, which completely changes its transport properties. The most striking difference to weakly ionized plasma is that diffusion will become intrinsically ambipolar. We further discuss means of plasma diagnostics. As noninvasive diagnostic methods we will discuss analysis of the ion beam, optical spectroscopy, and measurement of the x-ray bremsstrahlung continuum. From beam analysis and optical spectroscopy one may deduce ion densities, and electron densities and distribution functions as a mean over the line of sight along the axis (optical spectroscopy) or at the plasma edge (ion beam). From x-ray spectra one obtains information about the population of highly energetic electrons and the energy transfer from the driving electromagnetic waves to the plasma--basic data for plasma modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Project: Modeling Relativistic Electrons from Nuclear Explosions in the Magnetosphere [Slides]

We present a summary of the FY12 activities for DTRA-funded project 'Modeling Relativistic Electrons from Nuclear Explosions in the Magnetosphere'. We briefly review the outstanding scientific questions and discuss the work done in the last year to try to answer these questions. We then discuss the agenda for this Technical Meeting with the DTRA sponsors. In the last year, we have continued our efforts to understand artificial radiation belts from several different perspectives: (1) Continued development of Electron Source Model (ESM) and comparison to HANE test data; (2) Continued studies of relativistic electron scattering by waves in the natural radiation belts; (3) Began study of self-generated waves from the HANE electrons; and (4) Began modeling for the UCLA laser experiment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Method to measure spatial coherence of subangstrom electron beams

A method is described for measuring the intensity distribution of the electron source in a scanning transmission electron microscope (STEM) fitted with an objective lens aberration corrector. The method is applied to a C{sub s}-corrected 300 kV field emission gun TEM/STEM, which is found to have an effective source size of 0.56 A full width at half maximum (FWHM) under optical conditions suitable for high resolution STEM imaging. This corresponds to a probe intensity distribution at the specimen plane of 0.72 A FWHM using a probe-forming aperture of 25 mrad and including the measured residual lens aberrations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗