Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy conservation code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The Effects of Roof Membrane Color on Moisture Accumulation in Low-slope Commercial Roof Systems

The use of highly reflective roof membrane systems is being promoted and in some cases required in energy codes and green building codes and standards. Highly reflective membranes, which typically are light in color, have demonstrated reduced overall energy consumption in cooling dominated climate. These membranes also are theorized to reduce the heat island effect. Concern has been expressed about using highly reflective roof membrane systems in cool to cold climate zones because they potentially increase moisture accumulation in roof systems. Roof membranes are vapor retarders. The theory is that highly reflective membranes reflect the heat that could enter the roof assembly, potentially providing a condensing surface on the cold side of the roof assembly during winter months. The other concern is that roof systems using highly reflective membranes will not get hot enough during the summer months to dry out moisture that may have condensed or otherwise entered the roof assembly. This study focuses on mechanically attached, highly reflective, single-ply roof systems installed on low-slope (less than 2:12) structures in cool to cold climate zones. Three sources of data are considered when determining the moisture accumulation potential of these systems. 1.Test roof cuts taken during the winter months 2.Modeling data from a building envelope model specifically designed to evaluate moisture accumulation 3.Data from previous studies to determine the effects of roof membrane color on the drying rate of low-slope roof assemblies

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-species collisions for delta-f gyrokinetic simulations: Implementation and verification with GENE

we report a multi-species linearized collision operator based on the model developed by Sugama et al. has been implemented in the nonlinear gyrokinetic code, GENE. Such a model conserves particles, momentum, and energy to machine precision, and is shown to have negative definite free energy dissipation characteristics, satisfying Boltzmann’s H-theorem, including for realistic mass ratio. Finite Larmor Radius (FLR) effects have also been implemented into the local version of the code. For the global version of the code, the collision operator has been developed to allow for block-structured velocity space grids, allowing for computationally tractable collisional global simulations. The validity of the collision operator has been demonstrated by relaxation and conservation tests, as well as appropriate benchmarks. The newly implemented operator shall be used in future simulations to study magnetically confined fusion plasma turbulence and transport in more extreme regions with higher collisionality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-species collisions for delta-f gyrokinetic simulations: Implementation and verification with GENE

A multi-species linearized collision operator based on the model developed by Sugama et al. has been implemented in the nonlinear gyrokinetic code, GENE. Such a model conserves particles, momentum, and energy to machine precision, and is shown to have negative definite free energy dissipation characteristics, satisfying Boltzmann’s H-theorem, including for realistic mass ratio. Finite Larmor Radius (FLR) effects have also been implemented into the local version of the code. For the global version of the code, the collision operator has been developed to allow for block-structured velocity space grids, allowing for computationally tractable collisional global simulations. The validity of the collision operator has been demonstrated by relaxation and conservation tests, as well as appropriate benchmarks. The newly implemented operator shall be used in future simulations to study magnetically confined fusion plasma turbulence and transport in more extreme regions with higher collisionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrating Renewable Energy Requirements Into Building Energy Codes

This report evaluates how and when to best integrate renewable energy requirements into building energy codes. The basic goals were to: (1) provide a rough guide of where we’re going and how to get there; (2) identify key issues that need to be considered, including a discussion of various options with pros and cons, to help inform code deliberations; and (3) to help foster alignment among energy code-development organizations. The authors researched current approaches nationally and internationally, conducted a survey of key stakeholders to solicit input on various approaches, and evaluated the key issues related to integration of renewable energy requirements and various options to address those issues. The report concludes with recommendations and a plan to engage stakeholders. This report does not evaluate whether the use of renewable energy should be required on buildings; that question involves a political decision that is beyond the scope of this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodology for Developing the REScheckTM Software through Version 4.4.2

The Energy Policy Act of 1992 (EPAct, Public Law 102-486) establishes the 1992 Model Energy Code (MEC), published by the Council of American Building Officials (CABO), as the target for several energy-related requirements for residential buildings (CABO 1992). The U.S. Department of Housing and Urban Development (HUD) and the U.S. Department of Agriculture (via Rural Economic and Community Development [RECD] [formerly Farmers Home Administration]) are required to establish standards for government-assisted housing that 'meet or exceed the requirements of the Council of American Building Officials Model Energy Code, 1992.' CABO issued 1992, 1993, and 1995 editions of the MEC (CABO 1992, 1993, and 1995).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Guide to Building Commissioning

Commissioning is the process of verifying that a building's heating, ventilation, and air conditioning (HVAC) and lighting systems perform correctly and efficiently. Without commissioning, system and equipment problems can result in higher than necessary utility bills and unexpected and costly equipment repairs. This report reviews the benefits of commissioning, why it is a requirement for Leadership in Energy and Environmental Design (LEED) certification, and why building codes are gradually adopting commissioning activities into code.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enforcing Building Energy Codes in China: Progress and Comparative Lessons

From 1995 to 2005, building energy use in China increased more rapidly than the world average. China has been adding 0.4 to 1.6 billion square meters of floor space annually , making it the world’s largest market for new construction. In fact, by 2020, China is expected to comprise half of all new construction. In response to this, China has begun to make important steps towards achieving building energy efficiency, including the implementation of building energy standards that requires new buildings to be 65% more efficient than buildings from the early 1980s. Making progress on reducing building energy use requires both a comprehensive code and a robust enforcement system. The latter – the enforcement system – is a particularly critical component for assuring that a building code has an effect. China has dramatically enhanced its enforcement system in the past two years, with more detailed requirements for ensuring enforcement and new penalties for non-compliance. We believe that the U.S. and other developed countries could benefit from learning about the multiple checks and the documentation required in China. Similarly, some of the more user-friendly enforcement approaches developed in the U.S. and elsewhere may be useful for China as it strives to improve enforcement in rural and smaller communities. In this article, we provide context to China’s building codes enforcement system by comparing it to the U.S. Among some of the enforcement mechanisms we look at are testing and rating procedures, compliance software, and training and public information.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Commercial Construction Characteristics and Compliance With Building Energy Codes: 1999-2007

As States adopt the latest energy standards which continue to be developed with more stringent requirements, a better understanding of actual compliance with standards and construction practice can be important. Claims are made that energy-related standards impose excessive burdens on building owners and the construction industry. Other claims indicate that many energy-codes requirements are common practice and will have little impact on the building community. Analysis of code effects as well as energy efficiency projects and programs are also more important than ever. These energy realities create a need for better information on the current state of new commercial construction. Regional and national studies exist that provide primarily survey data for only selections of buildings in specific locations. This paper presents an assessment of how current new commercial construction complies with applicable energy codes on a national basis for a range of code levels represented by buildings designed in the 1999 – 2007 timeframe. This analysis makes use of a recently updated commercial buildings database with more than 130 energy-related building characteristics from over 340 new commercial buildings across the United States. Energy code compliance of the buildings in this sample is assessed using the COMcheck™ energy standard compliance software tool to determine how closely new construction across the nation is to meeting current and recently adopted energy codes such as ASHRAE/IESNA 90.1. The results present an interesting look at where code requirements stand with respect to current construction and provide insights into the challenges faced by the building community to meet these standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of ray-based cross-beam energy transfer models

Ray-based cross-beam energy transfer (CBET) models have become a common feature of the radiation-hydrodynamic codes used to simulate inertial confinement fusion experiments. Here, these models are necessary for achieving better agreement with experimental measurements, but their detailed implementation can vary widely between the codes and often rely on artificial multipliers. To address this, a series of 2D and 3D test cases has been developed with validated solutions from wave-based calculations. Comparisons of various ray-based CBET models to the wave-based calculations highlight the essential physics that is required for accurate ray-based CBET modeling. Quantitative comparison metrics and/or field data from the wave-based calculations have been made available for use in the validation of other ray-based CBET codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Living off-grid in an arid environment without a well : can residential and commercial/industrial water harvesting help solve water supply problems?

Our family of three lives comfortably off-grid without a well in an arid region ({approx}9 in/yr, average). This year we expect to achieve water sustainability with harvested or grey water supporting all of our needs (including a garden and trees), except drinking water (about 7 gallons/week). We discuss our implementation and the implication that for an investment of a few thousand dollars, many single family homes could supply a large portion of their own water needs, significantly reducing municipal water demand. Generally, harvested water is very low in minerals and pollutants, but may need treatment for microbes in order to be potable. This may be addressed via filters, UV light irradiation or through chemical treatment (bleach). Looking further into the possibility of commercial water harvesting from malls, big box stores and factories, we ask whether water harvesting could supply a significant portion of potable water by looking at two cities with water supply problems. We look at the implications of separate municipal water lines for potable and clean non-potable uses. Implications on changes to future building codes are explored.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A NUMERICAL TREATMENT OF ANISOTROPIC RADIATION FIELDS COUPLED WITH RELATIVISTIC RESISTIVE MAGNETOFLUIDS

We develop a numerical scheme for solving fully special relativistic, resistive radiation magnetohydrodynamics. Our code guarantees conservation of total mass, momentum, and energy. The radiation energy density and the radiation flux are consistently updated using the M-1 closure method, which can resolve an anisotropic radiation field, in contrast to the Eddington approximation, as well as the flux-limited diffusion approximation. For the resistive part, we adopt a simple form of Ohm's law. The advection terms are explicitly solved with an approximate Riemann solver, mainly the Harten-Lax-van Leer scheme; the HLLC and HLLD schemes are also solved for some tests. The source terms, which describe the gas-radiation interaction and the magnetic energy dissipation, are implicitly integrated, relaxing the Courant-Friedrichs-Lewy condition even in an optically thick regime or a large magnetic Reynolds number regime. Although we need to invert 4 Multiplication-Sign 4 matrices (for the gas-radiation interaction) and 3 Multiplication-Sign 3 matrices (for the magnetic energy dissipation) at each grid point for implicit integration, they are obtained analytically without preventing massive parallel computing. We show that our code gives reasonable outcomes in numerical tests for ideal magnetohydrodynamics, propagating radiation, and radiation hydrodynamics. We also applied our resistive code to the relativistic Petschek-type magnetic reconnection, revealing the reduction of the reconnection rate via radiation drag.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy dynamics and current sheet structure in fluid and kinetic simulations of decaying magnetohydrodynamic turbulence

Simulations of decaying magnetohydrodynamic (MHD) turbulence are performed with a fluid and a kinetic code. The initial condition is an ensemble of long-wavelength, counter-propagating, shear-Alfvén waves, which interact and rapidly generate strong MHD turbulence. The total energy is conserved and the rate of turbulent energy decay is very similar in both codes, although the fluid code has numerical dissipation, whereas the kinetic code has kinetic dissipation. The inertial range power spectrum index is similar in both the codes. The fluid code shows a perpendicular wavenumber spectral slope of k{sub ⊥}{sup −1.3}. The kinetic code shows a spectral slope of k{sub ⊥}{sup −1.5} for smaller simulation domain, and k{sub ⊥}{sup −1.3} for larger domain. We estimate that collisionless damping mechanisms in the kinetic code can account for the dissipation of the observed nonlinear energy cascade. Current sheets are geometrically characterized. Their lengths and widths are in good agreement between the two codes. The length scales linearly with the driving scale of the turbulence. In the fluid code, their thickness is determined by the grid resolution as there is no explicit diffusivity. In the kinetic code, their thickness is very close to the skin-depth, irrespective of the grid resolution. This work shows that kinetic codes can reproduce the MHD inertial range dynamics at large scales, while at the same time capturing important kinetic physics at small scales.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗