Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy systems optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Development of Supervisory Control System for Thermal Energy Distribution System

The integrated energy system (IES) refers to the combination of nuclear energy generation with other energy sources to enable the efficiency and reliability of power generations. To create technologically viable and economically competitive systems, supervisory control strategies are critical for optimizing performance and ensuring stability across different energy generation, transportation, and utilization. This work focuses on the control strategies for the thermal energy distribution system (TEDS), which is a cornerstone of the Dynamic Energy Transport and Integration Laboratory at Idaho National Laboratory. TEDS currently relies on operators to coordinate across different components to manage energy storage and ensure efficiency. This work demonstrates the use of model predictive control (MPC) with surrogate models in determining optimal setpoints for major TEDS components. The capability of MPC-based supervisory control system is evaluated by autonomously matching the power outputs from a Dymola-based TEDS with target heat demands.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Control and Management of Multiple Converters in a Residential Smart Grid

Power electronic systems are becoming a staple building block for electric grid networks. However, these systems have been largely designed to grid integrate in ad hoc configurations with little or no coordination of control. This work proposes a central controller and power electronic system hardware and software design for a residential system (photovoltaic, energy storage and residential building). This system supports auto-integration, plug and play capabilities, and optimal energy management to meet different use cases. Modelling and multi-day testing of the system have been conducted in a controller hardware-in-the-loop (C-HIL) testbed. Multiple use cases and pricing options have been considered as part of the simulation and testing. Results are presented of these systems as a proof of principle.

Starke, Michael↗

Multiscale simulation of integrated energy system and electricity market interactions

Accelerating the deep decarbonization of the world's electric grids requires the coordination of complex energy systems and infrastructures across timescales from seconds to decades. Here, we present a new multiscale simulation framework that integrates process- and grid-centric modeling paradigms to better design, operate, and control integrated energy systems (IESs), which combine multiple technologies, in wholesale energy markets. Traditionally, IESs are analyzed with a process-centric paradigm such as levelized cost of electricity (LCOE) or annualized net revenue, ignoring important interactions with electricity markets. This framework explicitly models the complex interactions between an IES's bidding, scheduling, and control decisions and the energy market's clearing and settlement processes, while incorporating operational uncertainties. Through two case studies, we show the importance of understanding and quantifying complex resource-grid interactions. In case study 1, we demonstrate that optimized bidding from one resource shifts the profit distribution for all energy systems in the market. This result suggests new and more flexible IES technologies can disrupt the economics of all market participants, possibly leading to accelerated retirements of less flexible resources. Interestingly, the optimized bidding has little impact on grid-level aggregate statistics, such as total generation costs and renewable penetration rate. While aggregate modeling strategies may remain valid under some IES adoption scenarios for analysis focused on regional outcomes, direct comparisons of IES technologies at specific locations without considering these interactions may lead to misleading or incorrect conclusions. In case study 2, we consider the design and flexible operation of IESs that hybridize conventional generators with energy storage. Through a sensitivity analysis, we find that as the size of the storage system increases, the total number of start-ups for coal- and natural gas-based IESs reduced by 25% and 33.6%, and the total thermal generator ramping (i.e., mileage) reduced by 86.5% and 62.5%, respectively. This shows the primary benefit of storage may not be reduced operational costs (which do not change significantly) but fewer start-ups and less ramping, which may greatly simplify the design, operation, and control of carbon capture systems. The new modeling and optimization capabilities from this work enable the coupling of rigorous, dynamic process models with grid-level production cost models to quantitatively identify the nuanced interdependencies across these vast timescales that must be addressed to realize clean, safe, and secure energy production. Moreover, the proposed general multiscale simulation framework is applicable to all IES technologies and can be easily extended to consider other energy carriers (e.g., hydrogen, ammonia) and energy infrastructures (e.g., natural gas pipelines).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Consensus-Based Control and Optimization of Power System Inertia

The integration of distributed energy resources (DERs), such as solar, wind, and energy storage systems, into power grids through inverter-based resources reduces power system inertia, leading to faster frequency dynamics and potential grid instability. To address this challenge, this paper proposes a distributed, consensus-based approach for the real-time control and optimization of inertia sources (synchronous generators and/or DERs) during system disturbances, enhancing both system stability and economic performance. The distributed control and optimization approach assumes each inertia source exchanges information solely with its neighbor ones, making it easily scalable to large power grid networks. The impacts of the communication connectivity among the inertia sources as well as their generation capacity limits on the distributed approach are investigated. We also demonstrate the approach’s robustness in scenarios involving communication time delays and packet losses, validating its effectiveness through numerical simulations on a 4-bus test system and a two-area 8-bus test system.

Power system inertia↗

Energy Management Information Systems Technical Resources Report

Guide supports federal facility staff in understanding, designing, procuring, and implementing Energy Management Information Systems (EMIS) as a valuable component of their portfolio-level energy and water planning and management strategies. As a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance, EMIS tools present significant opportunities for federal sector energy savings and improved operational performance. EMIS are at the forefront of transforming energy management best practices by providing building owners and operators with well-organized building performance and energy consumption data, enabling a host of analytic capabilities. These capabilities include portfolio-wide energy benchmarking, data visualization, and key performance indicator tracking; automated fault detection and diagnostics (AFDD); artificial intelligence for predictive analytics and control; automated measurement and verification of energy conservation measures; and supervisory control enabling automated system optimization and demand management.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Study of Storage Requirements and Costs for Shaping Renewables and Nuclear Energy (FY23 Summary Report)

To decarbonize electricity generation primarily by using wind and solar resources, it is likely that additional low (or zero) carbon dioxide (CO 2 ) alternatives will be required for ensuring a reliable electricity supply. This study extends the work and modeling framework that we consolidated in FY 2022, by assessing the zero-CO 2 pathways of a Texas power system in which the availability of variable renewable energy (VRE), nuclear energy, and energy storage types (i.e., battery and thermal energy storage [TES]) are considered the sole resources available for expansion. Using the Risk Analysis Virtual Environment (RAVEN) and Holistic Energy Resource Optimization Network (HERON) frameworks, this study investigates the market of two nuclear energy technologies (i.e., large light-water reactors [LWRs] and LWR-type small modular reactors [SMRs]) under two plausible storage coupling scenarios (i.e., electric coupling and direct thermal coupling). We also explore optimal environments for nuclear energy deployment, and identify key performance characteristics that make nuclear energy economically viable in areas with significant intermittent energy sources. Our analysis encompasses 24 cases. We model the least-cost grid systems, highlight the potential for a coupled LWR-TES approach, and utilize SMRs to achieve deep decarbonization in an affordable, technically feasible manner. We also examine seasonal variations in balancing electricity supply and demand, and account for varying performance, costs, and grid constraints. Overall, the findings of our modeling afford valuable insights for supporting future technology investment decisions in the energy sector.

25 ENERGY STORAGE↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predictive modeling of a subcritical pulverized-coal power plant for optimization: Parameter estimation, validation, and application

As renewable power generation deployment increases, fossil fuel plants are increasingly required to operate more flexibly. Many coal-fired power plants were originally designed to operate at base load and do not operate optimally at partial load. Predictive first-principles plant-wide models can be employed to identify opportunities for flexibility improvements and diagnose low-load operating issues. This paper describes the application of the Institute for the Design of Advanced Energy Systems Integrated Platform (IDAES) to model and optimize flexible power plant operations. The key benefits of using IDAES are that it provides an open-source, fully equation-oriented modeling framework for efficient modular model construction, reuse, and customization, together with a mathematical optimization framework leveraging powerful, state-of-the-art solvers. The process systems engineering workflow from predictive process simulation to parameter estimation, model validation, and plant optimization is applicable to a variety of existing and next-generation energy systems as well as other chemical and environmental processes. Here, to demonstrate this capability, a physics-based, steady-state model was developed to improve full- and part-load performance of the Escalante Generating Station, a 245 MWe (net) subcritical pulverized coal-fired power plant owned and operated by Tri-State Generation and Transmission Association. Specifically, sixty-nine model parameters were simultaneously estimated from several months of operating data enabling prediction of flow rates, temperatures, pressures, and steam quality throughout the plant. The validated model was leveraged by Escalante to reduce the minimum operating load from 90 MW to 50 MW by diagnosing a low-load water-hammer issue, enabling coal usage and emissions reductions during periods of low power demand. Additionally, opportunities for heat rate reduction (i.e., efficiency improvement) through a steeper sliding-pressure approach to load-following and optimization of other boiler operating variables were also identified and quantified. For example, a potential efficiency improvement of 0.7 percentage points was observed at half-load operation.

01 COAL, LIGNITE, AND PEAT↗

Synergistic Integration of Multiple Wave Energy Converters with Adaptive Resonance and Offshore Floating Wind Turbines through Bayesian Optimization

We developed a synergistic ocean renewable system where an array of Wave Energy Converters (WEC) with adaptive resonance was collocated with a Floating Offshore Wind Turbine (FOWT) such that the WECs, capturing wave energy through the resonance adapting to varying irregular waves, consequently reduced FOWFT loads and turbine motions. Combining Surface-Riding WECs (SR-WEC) individually designed to feasibly relocate their natural frequency at the peak of the wave excitation spectrum for each sea state, and to obtain the highest capture width ratio at one of the frequent sea states for annual average power in a tens of kilowatts scale with a 15 MW FOWT based on a semi-submersible, Bayesian Optimization is implemented to determine the arrangement of WECs that minimize the annual representation of FOWT’s wave excitation spectra. The time-domain simulation of the system in the optimized arrangement is performed, including two sets of interactions: one set is the wind turbine dynamics, mooring lines, and floating body dynamics for FOWT, and the other set is the nonlinear power-take-off dynamics, linear mooring, and individual WECs’ floating body dynamics. Those two sets of interactions are further coupled through the hydrodynamics of diffraction and radiation. For sea states comprising Annual Energy Production, we investigate the capture width ratio of WECs, wave excitation on FOWT, and nacelle acceleration of the turbine compared to their single unit operations. We find that the optimally arranged SR-WECs reduce the wave excitation spectral area of FOWT by up to 60% and lower the turbine’s peak nacelle acceleration by nearly 44% in highly occurring sea states, while multiple WECs often produce more than the single operation, achieving adaptive resonance with a larger wave excitation spectra for those sea states. The synergistic system improves the total Annual Energy Production (AEP) by 1440 MWh, and we address which costs of Levelized Cost Of Energy (LCOE) can be reduced by the collocation.

Engineering↗

Phase I Final Technical Report on Energy-Efficient Reconfigurable Universal Accelerator Interconnect

It is well known that application specific computing systems, optimally designed and configured for a given workload, offer much higher energy-efficiency and throughput than general purpose systems. In modern computing systems, heterogeneous computing systems have emerged that exploit the energy and performance benefits of combining various different domain-specific processor architectures. Application domains such as high-performance computing and machine learning now process terabyte-sized data sets, requiring enormous processing and memory resources. These applications have very high-power consumption due to bottlenecks in the electrical interconnection between processing units. This project aims to reduce both communication energy and latency by integrating universally available accelerators with silicon photonics. It also aims to increase system throughput by exploiting emerging technologies in silicon photonic reconfigurable interconnects; this will allow the system to balance itself in real time to accommodate changes in workloads and data flows.

2.5D/3D integration↗

Potential Adoption and Benefits of Co-Optimized Multimode Engines and Fuels for U.S. Light-Duty Vehicles

Exploring a diverse portfolio of technologies for decarbonization is crucial to understanding the potential impacts of different technological solutions and their associated environmental implications. Using high-octane, high-sensitivity biofuel blends in co-optimized multimode engines can increase engine efficiency and reduce vehicle emissions. Here, the multimode engine research focuses on the benefits of light-duty vehicle engines, which can operate in multiple modes depending on the vehicle's load. Low-temperature combustion can improve efficiency and reduce emissions (such as those from oxides of nitrogen and particulate matter) during low-load operation, while spark ignition performance is maintained in high-load operation. These advanced engines can be optimized to run on blends of biobased fuels. This analysis models scenarios for potential market adoption of co-optimized multimode vehicles fueled by three different bioblendstocks: ethanol, isopropanol, and isobutanol. An integrated modeling approach is used to forecast the energy and environmental impacts of the deployment of co-optimized multimode vehicles and fuels in the light-duty sector over the 2020-to-2050 time horizon. The multidisciplinary approach combines vehicle sales modeling, system dynamics modeling of the biorefining industry, and life cycle assessment to estimate the emissions and energy benefits. The models consider market forces such as consumer preferences for vehicle attributes, biofuel supply and demand dynamics subject to biorefinery capacity build-out and bioresource constraints, and forecasted changes to the U.S. bulk energy system over time. Market adoption of co-optimized vehicles is evaluated across a wide parameter space for incremental vehicle cost and engine efficiency improvement. This analysis reveals that the deployment of co-optimized multimode fuels and vehicles results in up to a 5% reduction in annual sector-wide life cycle greenhouse gas (GHG) emissions by 2050, relative to a business-as-usual scenario, but is also indicates environmental trade-offs, such as higher life cycle water-use. Emission benefits could potentially increase beyond 2050, as the new technologies penetrate the market and gain a foothold. Results also show that, under certain circumstances, vehicles with engines co-optimized for use with high-octane, high-sensitivity biofuel blends can be cost-competitive with conventional gasoline, while reducing GHG emissions. Our modeling results indicate that co-optimized multimode fuels and engines can be strategically leveraged in tandem with electrification to decarbonize the light-duty sector. Co-optimized vehicles could play a role in the early years of the time horizon, while electric vehicles (EVs) could become more competitive in the later years, highlighting the complementary benefits of these technologies for GHG reductions.

Oke, Doris↗

High energy yield bifacial spectrum-splitting photovoltaic system

In this paper a photovoltaic system is proposed that achieves high energy yield by integrating bifacial silicon cells into a spectrum-splitting module. Spectrum splitting is accomplished using volume holographic optical elements to spectrally divide sunlight onto an array of photovoltaic cells with different bandgap energies. Light that is reflected from the ground surface onto the rear side of the module is converted by the bifacial silicon cells. The energy yield of the system is optimized by tuning the volume holographic element parameters, such as film thickness, index modulation, and construction point source positions. An example is presented for utility-scale illumination parameters in Tucson, Arizona, that attains an energy yield of 1010 k w ⋅ <#comment/> h r y r ⋅ <#comment/> m 2 , which is 32.8% of the incident solar insolation.

Chrysler, Benjamin D. (ORCID:0000000186250147)↗

Applied genomics for industrially relevant microalgal strain development & optimization: characterizing genotype-phenotype relationships towards scalable environment-enhancing energy systems

Multiple planetary boundaries considered a safe operating space for humanity have been exceeded in recent years, with twice as many boundaries transgressed in 2023 as in 2009. Bioenergy systems are unique in that they can interact with and improve many of the transgressed boundaries directly, including multiple geochemical cycles, water and land use, and climate change. Among bioenergy systems, microalgae-based environment enhancing energy (E 2 -energy) are promising bioenergy systems for drop-in biofuels, valuable materials, chemicals and therapeutics, while making deep emission cuts and remediating wastewater, all without competing for agricultural resources.

09 BIOMASS FUELS↗

Energy Optimization of Light and Heavy-Duty Vehicle Cohorts of Mixed Connectivity, Automation and Propulsion System Capabilities via Meshed V2V-V2I and Expanded Data Sharing (Final Scientific and Technical Report)

Vehicle connectivity and automated driving technologies individually have the potential to decrease energy consumption and/or increase safety on light, medium or heavy duty vehicles to varying degrees depending on the traffic infrastructure and specific driving scenarios. Due to advances in sensing, perception and computing power, research and development emphasis in the mobility sector has shifted away from connectivity. Prior research has shown that driving automation with the absence of connectivity can in certain circumstances increase energy consumption. The effectiveness of synergizing connectivity and driving automation technologies is the focus of this work, specifically applied to vehicle cohorts of mixed composition, light and heavy duty, and powertrains ranging from all electric to conventional internal combustion engine. The project team is led by Michigan Technological University (MTU) and partnered with AVL Mobility Technologies Inc. (AVL), Borg Warner (BW), Traffic Technology Services (TTS), American Center for Mobility (ACM) and Navistar (NAV). The main thrusts for the team are to develop a micro-traffic simulation environment with specific VD&PT system attributes and CAV capabilities, 2) field a vehicle test fleet of mixed classification, propulsion and CAV capacity, 3) develop artificial intelligence (AI) and machine learning (ML) based multi-agent optimization methods for various traffic infrastructures, 4) integrate the virtual environment and the optimization methods then deploy the system as a CAV hardware in the loop (HiL) for the vehicle test fleet and 5) conduct closed track and public road testing to validate simulation and demonstrated energy and mobility improvements at multiple scales. For a cohort of mixed vehicles, the team will demonstrate a reduction of energy consumption of 10-50% at intersection, arterial roadway and limited access highway scenarios through connectivity and automation in simulation and at a closed test track. The energy reduction objectives of the project are summarized in Table 1, indicating the infrastructure and over what distances are relevant considered. Single scenario energy reductions are not relevant and thus, the research team took the approach to vary parameters associated with the infrastructure, vehicle cohort composition and dynamic behavior to generate energy consumption distributions for both unconnected and connected scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economic Analysis of Integrated Solar Power, Hydrogen Production, and Electricity Markets

Hydrogen is a versatile energy carrier that is used in a wide variety of chemical and industrial processes. Producing hydrogen using electrolysis can enable integration of multiple sectors including electricity, heating, and industrial sectors; however, the cost of producing hydrogen from electrolysis remains a challenge for encouraging greater adoption. To help improve the economics for both solar PV and hydrogen production using electrolyzers, we explore the benefit of combining PV and electrolysis systems. Using the Revenue Operation and Device Optimization Model (RODeO) model, the optimal breakeven hydrogen production cost for six unique market participation configurations is calculated at six candidate locations in California where PV is already installed. Costs include production, storage, and compression in preparation for gaseous delivery trucks. Revenue streams included in the optimization are the sale of hydrogen, Low Carbon Fuel Standard (LCFS) credits, renewable electricity sold to the grid, and Renewable Energy Credits (REC). The costs included are the electricity costs, capital and fixed operation and maintenance cost (FOM) for the electrolyzer, PV, and storage and compression systems as well as taxes and financing costs. In addition, cost reductions are achieved through retail and wholesale electricity use optimization, by which electricity is purchased at the lowest price and sold, if possible, at the highest price. For all locations analyzed, the breakeven hydrogen production cost results show that, in order of decreasing cost, the system configurations are islanded (highest), separated, NEM, retail, hybrid retail/wholesale, and wholesale (lowest). This report also explores other aspects of hydrogen systems including optimal renewable sizing and resulting energy mixture to the electrolyzer, value of renewable premiums, competition with incumbent technologies, cost sensitivity to a variety of parameters.

decarbonized economy↗