Search NASA⌕ Search

SEARCH · Search NASA

Results for “error fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Machine learning from RANS and LES to inform coarse grid simulations

Nuclear system thermal hydraulic analysis has historically relied on computationally inexpensive 1D codes. However, such tools are unable to capture multiscale multidimensional effects in large nuclear reactor enclosures. On the other hand, simulations with higher fidelity can be too expensive for such purposes. One of the ways to reduce computational cost is to perform simulations on a coarse grid, which, unfortunately, introduces large discretization errors. In this paper, two high-to-low data-driven approaches are investigated: (1) a coarse grid turbulence model to predict eddy viscosity and (2) correction of errors in coarse grid velocity fields. The approaches aim to reduce grid- and turbulence model-induced errors in coarse grid Reynolds-averaged Navier–Stokes (RANS) simulations. Two sources of high-fidelity data, RANS and large eddy simulations (LES), are explored. To extract the eddy viscosity from the LES data, an inverse optimization problem is solved. However, the LES eddy viscosity is shown to be comparable to the RANS eddy viscosity in terms of error reduction. Therefore, the directly available RANS eddy viscosity was used to develop a coarse grid data-driven turbulence model. Additionally, error correction in velocity is used to reduce the remaining uncertainties and bring the results closer to reality. In conclusion, the performance of the frameworks is demonstrated for a scaled upper plenum of a gas-cooled reactor facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Beam characteristics of energy-matched flattening filter free beams

Purpose: Flattening filter free (FFF) linear accelerators can increase treatment efficiency and plan quality. There are multiple methods of defining a FFF beam. The Elekta control system supports tuning of the delivered FFF beam energy to enable matching of the percentage depth-dose (PDD) of the flattened beam at 10 cm depth. This is compared to FFF beams where the linac control parameters are identical to those for the flattened beam. All beams were delivered on an Elekta Synergy accelerator with an Agility multi-leaf collimator installed and compared to the standard, flattened beam. The aim of this study is to compare “matched” FFF beams to both “unmatched” FFF beams and flattened beams to determine the benefits of matching beams. Methods: For the three modes of operation 6 MV flattened, 6 MV matched FFF, 6 MV unmatched FFF, 10 MV flattened, 10 MV matched FFF, and 10 MV unmatched FFF beam profiles were obtained using a plotting tank and were measured in steps of 0.1 mm in the penumbral region. Beam penumbra was defined as the distance between the 80% and 20% of the normalized dose when the inflection points of the unflattened and flattened profiles were normalized with the central axis dose of the flattened field set as 100%. PDD data was obtained at field sizes ranging from 3 cm × 3 cm to 40 cm × 40 cm. Radiation protection measurements were additionally performed to determine the head leakage and environmental monitoring through the maze and primary barriers. Results: No significant change is made to the beam penumbra for FFF beams with and without PDD matching, the maximum change in penumbra for a 10 cm × 10 cm field was within the experimental error of the study. The changes in the profile shape with increasing field size are most significant for the matched FFF beam, and both FFF beams showed less profile shape variation with increasing depth when compared to flattened beams, due to consistency in beam energy spectra across the radiation field. The PDDs of the FFF beams showed less variation with field size, the d{sub max} value was deeper for the matched FFF beam than the FFF beam and deeper than the flattened beam for field sizes greater than 5 cm × 5 cm. The head leakage when using the machine in FFF mode is less than half that for a flattened beam, but comparable for both FFF modes. The radiation protection dose-rate measurements show an increase of instantaneous dose-rates when operating the machines in FFF mode but that increase is less than the ratio of MU/min produced by the machine. Conclusions: The matching of a FFF beam to a flattened beam at a depth of 10 cm in water by increasing the FFF beam energy does not reduce any of the reported benefits of FFF beams. Conversely, there are a number of potential benefits resulting from matching the FFF beam; the depth of maximum dose is deeper, the out of field dose is potentially reduced, and the beam quality and penetration more closely resembles the flattened beams currently used in clinical practice, making dose distributions in water more alike. Highlighted in this work is the fact that some conventional specifications and methods for measurement of beam parameters such as penumbra are not relevant and further work is required to address this situation with respect to “matched” FFF beams and to determine methods of measurement that are not reliant on an associated flattened beam.

43 PARTICLE ACCELERATORS↗

SU-E-T-377: Inaccurate Positioning Might Introduce Significant MapCheck Calibration Error in Flatten Filter Free Beams

Purpose: This study investigates the calibration error of detector sensitivity for MapCheck due to inaccurate positioning of the device, which is not taken into account by the current commercial iterative calibration algorithm. We hypothesize the calibration is more vulnerable to the positioning error for the flatten filter free (FFF) beams than the conventional flatten filter flattened beams. Methods: MapCheck2 was calibrated with 10MV conventional and FFF beams, with careful alignment and with 1cm positioning error during calibration, respectively. Open fields of 37cmx37cm were delivered to gauge the impact of resultant calibration errors. The local calibration error was modeled as a detector independent multiplication factor, with which propagation error was estimated with positioning error from 1mm to 1cm. The calibrated sensitivities, without positioning error, were compared between the conventional and FFF beams to evaluate the dependence on the beam type. Results: The 1cm positioning error leads to 0.39% and 5.24% local calibration error in the conventional and FFF beams respectively. After propagating to the edges of MapCheck, the calibration errors become 6.5% and 57.7%, respectively. The propagation error increases almost linearly with respect to the positioning error. The difference of sensitivities between the conventional and FFF beams was small (0.11 ± 0.49%). Conclusion: The results demonstrate that the positioning error is not handled by the current commercial calibration algorithm of MapCheck. Particularly, the calibration errors for the FFF beams are ~9 times greater than those for the conventional beams with identical positioning error, and a small 1mm positioning error might lead to up to 8% calibration error. Since the sensitivities are only slightly dependent of the beam type and the conventional beam is less affected by the positioning error, it is advisable to cross-check the sensitivities between the conventional and FFF beams to detect potential calibration errors due to inaccurate positioning. This work was partially supported by a DOD Grant No.; DOD W81XWH1010862.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining circuit model parameters from operation data for PV system degradation analysis: $\mathrm{PVPRO}$

Physics-based circuit parameters like series and shunt resistance are essential to provide insights into the degradation status of photovoltaic (PV) arrays. However, calculating these parameters typically requires a full current-voltage characteristic (I-V curve), the acquisition of which involves specific measurement devices and costly methods. Thus, I-V curves of the PV system level are often not available. Here this paper proposes a methodology (PVPRO) to estimate these I-V curve parameters using only operation (string-level DC voltage and current) and weather data (irradiance and temperature). PVPRO first performs multi-stage data pre-processing to remove noisy data. Next, the time-series DC data are used to fit an equivalent circuit single-diode model (SDM) to estimate the circuit parameters by minimizing the differences between the measured and estimated values. In this way, the time evolutions of the SDM parameters are obtained. We evaluate PVPRO on synthetic datasets and find an excellent estimation of both SDM and the key I-V parameters (e.g., open-circuit voltage, short-circuit current, maximum power, etc.) with an average relative error of 0.55%. The performance, especially the extracted degradation rate of parameters, is robust to various measurement noises and the presence of faults. In addition, PVPRO is applied to a 271 kW PV field system. The relative error between the real and estimated operation voltage and current is less than 1%, suggesting that degradation trends are well captured. PVPRO represents a promising open-source tool to extract the time-series degradation trends of key PV parameters from routine operation data.

14 SOLAR ENERGY↗

Indirect determination of the electric field in plasma discharges using laser-induced fluorescence spectroscopy

The evaluation of electric fields is of prime interest for the description of plasma characteristics. In this work, different methods for determining the electric field profile in low-pressure discharges using one- and two-dimensional Laser-Induced Fluorescence (LIF) measurements are presented and discussed. The energy conservation, fluid, and kinetic approaches appear to be well-suited for the electric field evaluation in this region of the plasma flow. However, the numerical complexity of a two-dimensional kinetic model is penalizing due to the limited signal-to-noise ratio that can be achieved, making the computation of the electric field subject to large error bars. The ionization contribution which appears in the fluid model makes it unattractive on an experimental viewpoint. The energy conservation and 1D1V kinetic approaches should therefore be preferred for the determination of the electric field when LIF data are used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of sky radiance measurement errors on inversion-retrieved aerosol properties

Remote sensing of the atmospheric aerosol is a well-established technique that is currently used for routine monitoring of this atmospheric component, both from ground-based and satellite. The AERONET program, initiated in the 90's, is the most extended network and the data provided are currently used by a wide community of users for aerosol characterization, satellite and model validation and synergetic use with other instrumentation (lidar, in-situ, etc.). Aerosol properties are derived within the network from measurements made by ground-based Sun-sky scanning radiometers. Sky radiances are acquired in two geometries: almucantar and principal plane. Discrepancies in the products obtained following both geometries have been observed and the main aim of this work is to determine if they could be justified by measurement errors. Three systematic errors have been analyzed in order to quantify the effects on the inversion-derived aerosol properties: calibration, pointing accuracy and finite field of view. Simulations have shown that typical uncertainty in the analyzed quantities (5% in calibration, 0.2 Degree-Sign in pointing and 1.2 Degree-Sign field of view) yields to errors in the retrieved parameters that vary depending on the aerosol type and geometry. While calibration and pointing errors have relevant impact on the products, the finite field of view does not produce notable differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

He I VECTOR MAGNETOMETRY OF FIELD-ALIGNED SUPERPENUMBRAL FIBRILS

Atomic-level polarization and Zeeman effect diagnostics in the neutral helium triplet at 10830 A in principle allow full vector magnetometry of fine-scaled chromospheric fibrils. We present high-resolution spectropolarimetric observations of superpenumbral fibrils in the He I triplet with sufficient polarimetric sensitivity to infer their full magnetic field geometry. He I observations from the Facility Infrared Spectropolarimeter are paired with high-resolution observations of the H{alpha} 6563 A and Ca II 8542 A spectral lines from the Interferometric Bidimensional Spectrometer from the Dunn Solar Telescope in New Mexico. Linear and circular polarization signatures in the He I triplet are measured and described, as well as analyzed with the advanced inversion capability of the ''Hanle and Zeeman Light'' modeling code. Our analysis provides direct evidence for the often assumed field alignment of fibril structures. The projected angle of the fibrils and the inferred magnetic field geometry align within an error of {+-}10 Degree-Sign . We describe changes in the inclination angle of these features that reflect their connectivity with the photospheric magnetic field. Evidence for an accelerated flow ({approx}40 m s{sup -2}) along an individual fibril anchored at its endpoints in the strong sunspot and weaker plage in part supports the magnetic siphon flow mechanism's role in the inverse Evershed effect. However, the connectivity of the outer endpoint of many of the fibrils cannot be established.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-417: Experimental Verification of Robustness Optimized Intensity Modulated Proton Therapy Plans for Craniospinal Irradiation

Purpose: The robustness-optimized intensity modulated proton therapy (RO-IMPT) plans takes into account the setup errors to eliminate the hot/cold spots caused by setup errors at the junction for craniospinal (CSI) irradiation fields. The RO-IMPT requires a large area for the junction of two fields. This work is to verify the treatment planning system calculated dose with introduction of setup errors by two-dimensional (2D) dose measurement. Two fields of total lengths of 45 cm with junctions of 21 cm were measured. Methods: 2D dose distributions in the coronal plane were measured by a commercial 2D ion-chamber-array detector in a cubic solid water phantom. A total spine field consisting of an upper and a lower spine field was measured at the depths of 5.4 and 6.9 cm. The active area for the measurement was 24×24 cm{sup 2}2. The junction and the area outside the junction of the spine fields were measured separately to complete the verification for the total field. Six different amounts of set-up errors along the superior-inferior direction up to 1.4 cm were intentionally applied. The measured dose with and without set-up errors were compared with the calculated dose with and without set-up errors using Gamma-index analysis. 3%/3mm and 2%/2mm dose/distance agreement criteria were used. The point dose at the center of the junction was also compared. Results: For all fields with various introduced setup errors, 100 % of pixels passed the 3%/3mm criteria and on average 96% of pixels passed 2%/2mm criteria. Differences in the measured and calculated doses were within 1.1%. Conclusion: The efficacy of the robustness for the CSI RO-IMPT plans were verified by measurement. The measurement method can be used for patient treatment field specific QA for CSI RO-IMPT plans in our institution in the near future.

60 APPLIED LIFE SCIENCES↗

Fundamental limits in heat-assisted magnetic recording and methods to overcome it with exchange spring structures

The switching probability of magnetic elements for heat-assisted recording with pulsed laser heating was investigated. It was found that FePt elements with a diameter of 5 nm and a height of 10 nm show, at a field of 0.5 T, thermally written-in errors of 12%, which is significantly too large for bit-patterned magnetic recording. Thermally written-in errors can be decreased if larger-head fields are applied. However, larger fields lead to an increase in the fundamental thermal jitter. This leads to a dilemma between thermally written-in errors and fundamental thermal jitter. This dilemma can be partly relaxed by increasing the thickness of the FePt film up to 30 nm. For realistic head fields, it is found that the fundamental thermal jitter is in the same order of magnitude of the fundamental thermal jitter in conventional recording, which is about 0.5–0.8 nm. Composite structures consisting of high Curie top layer and FePt as a hard magnetic storage layer can reduce the thermally written-in errors to be smaller than 10{sup −4} if the damping constant is increased in the soft layer. Large damping may be realized by doping with rare earth elements. Similar to single FePt grains in composite structure, an increase of switching probability is sacrificed by an increase of thermal jitter. Structures utilizing first-order phase transitions breaking the thermal jitter and writability dilemma are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shallow Embedded Strain Measurements and Analysis for a NbTi Superconducting Sextupole Coil During Cooling, Excitation, and Quench

The present study deals with strain measurements and their numerical analysis for a niobium titanium wire wounded superconducting sextupole coil in a multi-field operation environment, including cooling down, excitation, and quench. Four low-temperature resistance strain gauges with designed compensation circuits were affixed directly on the surface of the superconducting wires but within glass fiber cloth. Before the sextuple coil’s test was carried out, for the purpose of reliability, based on the designed compensation circuit, some basic experiments were carried out during cooling down, excitation, and quench. The experimental results showed that the shallow embedded low-temperature resistance strain gauges were still highly reproducible with an error of 1% for a variable magnetic field and an error of 5% for a variable thermal field by executing various modes. It shows multi-stage strain monitoring is feasible for the superconducting sextupole. In addition, a numerical multiphysics model for the sextuple coil is also built from Maxwell’s equations and the equilibrium equations for mechanical and thermal deformation. A self-tested elastic modulus of NbTi/Cu stack with epoxy, which is cut from a NbTi/Cu sextupole prototype, at low temperature is used in this simulation. The numerical results have reasonable agreement with the experimental observations and show the multiphysics model with self-tested elastic modulus can be applied to analysis strain behaviors under complicated fields before superconducting magnet assembly. The present results will also provide some strain-measuring technology and multiphysics numerical analysis on an LTS/HTS superconducting magnet developed at the Institute of Modern Physics, Chinese Academy of Sciences (IMP, CAS).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Surface mass balance contributions to acceleration of Antarctic ice mass loss during 2003-2013: ANTARCTIC ICE MASS LOSS ACCELERATION

Recent observations from satellite gravimetry (the Gravity Recovery and Climate Experiment (GRACE) mission) suggest an acceleration of ice mass loss from the Antarctic Ice Sheet (AIS). The contribution of surface mass balance changes (due to variable precipitation) is compared with GRACE-derived mass loss acceleration by assessing the estimated contribution of snow mass from meteorological reanalysis data. We find that over much of the continent, the acceleration can be explained by precipitation anomalies. However, on the Antarctic Peninsula and other parts of West Antarctica, mass changes are not explained by precipitation and are likely associated with ice discharge rate increases. The total apparent GRACE acceleration over all of the AIS between 2003 and 2013 is -13.6 ± 7.2 Gt/yr2 . Of this total, we find that the surface mass balance component is -8.2 ± 2.0 Gt/yr2 . However, the GRACE estimate appears to contain errors arising from the atmospheric pressure fields used to remove air mass effects. The estimated acceleration error from this effect is about 9.8 ± 5.8 Gt/yr2 . Correcting for this yields an ice discharge acceleration of -15.1 ± 6.5 Gt/yr2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determining the rotation direction in pulsars

Abstract Pulsars are rotating neutron stars emitting lighthouse-like beams. Owing to their unique properties, pulsars are a unique astrophysical tool to test general relativity, inform on matter in extreme conditions, and probe galactic magnetic fields. Understanding pulsar physics and emission mechanisms is critical to these applications. Here we show that mechanical-optical rotation in the pulsar magnetosphere affects polarisation in a way which is indiscernible from Faraday rotation in the interstellar medium for typical GHz observations frequency, but which can be distinguished in the sub-GHz band. Besides being essential to correct for possible systematic errors in interstellar magnetic field estimates, this result offers a unique means to determine the rotation direction of pulsars, providing additional constraints on magnetospheric physics. With the ongoing development of sub-GHz observation capabilities, our finding promises discoveries, such as the spatial distribution of pulsars rotation directions, which could exhibit potentially interesting, but presently invisible, correlations or features.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Trigonometric Parallaxes of Two T Dwarfs With Keck and ShaneAO Astrometry

We present trigonometric parallax and proper motion measurements for two T-type brown dwarfs. We derive our measurements from infrared laser guide star adaptive optics observations spanning five years from the ShaneAO/SHARCS and NIRC2/medium-cam instruments on the Shane and Keck telescopes, respectively. To improve our astrometric precision, we measure and apply a distortion correction to our fields for both instruments. We also transform the Keck and ShaneAO astrometric reference frames onto the ICRS using five-parameter parallax and proper motion solutions for background reference stars from Gaia DR2. Fitting for parallax and proper motion, we measure parallaxes of 73.5 ± 9.2 mas and 70.1 ± 6.7 mas for WISEJ19010703+47181688 (WISE1901) and WISEJ21543294+59421370 (WISE2154), respectively. We utilize Monte Carlo methods to estimate the error in our sparse field methods, taking into account overfitting and differential atmospheric refraction. Comparing to previous measurements in the literature, all of our parallax and proper motion values fall within 2σ of the published measurements, and 4 of 6 measurements are within 1σ. These data are among the first parallax measurements of these T dwarfs and serve as precise measurements for calibrating stellar formation models. These two objects are the first results of an ongoing survey of T dwarfs with Keck/NIRC2 and the Shane Adaptive Optics system at Lick Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Hybrid iterative approach for simulation of radio-frequency fields in plasma

In this work, a novel iterative approach for solving discretized linear wave equations in a frequency domain, which combines time evolution with iterative relaxation schemes, is presented. In this hybrid approach, each iteration cycle consists of evolution of electromagnetic (EM) fields in time over a specified number of field periods followed by several iterative relaxations. Provided that there is sufficient dissipation, both the time evolution and the iterative relaxations contribute to the convergence of the EM fields to the solution of the formulated full wave boundary value problem. Time evolution rapidly distributes EM fields, propagating with group velocity, over the simulation domain, while the iterative relaxations smooth the fields, reducing the numerical errors such that iteration cycles converge to a steady state solution, approximating the solution of the formulated problem. This approach is intended for large scale simulations which are beyond the capabilities of direct solvers presently used for solving wave equations in the frequency domain. Lastly, the technique is demonstrated for solving wave equations on a regular grid using a cold plasma dielectric model with collisions for 2D modeling of EM fields in tokamak in an electron cyclotron frequency range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field Quality from Tolerance Stack-up In R&D Quadrupoles for the Advanced Photon Source Upgrade

The Advanced Photon Source (APS) at Argonne National Laboratory (ANL) is considering upgrading the current double-bend, 7-GeV, 3rd generation storage ring to a 6-GeV, 4th generation storage ring with a Multibend Achromat (MBA) lattice. In this study, a novel method is proposed to determine fabrication and assembly tolerances through a combination of magnetic and mechanical tolerance analyses. Mechanical tolerance stackup analyses using Teamcenter Variation Analysis are carried out to determine the part and assembly level fabrication tolerances. Finite element analyses using OPERA are conducted to estimate the effect of fabrication and assembly errors on the magnetic field of a quadrupole magnet and to determine the allowable tolerances to achieve the desired magnetic performance. Finally, results of measurements in R&D quadrupole prototypes are compared with the analysis results.

Quadrupole, Field quality, tolerance, Finite Eleme↗

QCD Analysis of the semi-inclusive HERMES and COMPASS data

The first moments of polarized valence PDFs, responsible for the respective contributions to the nucleon spin, are extracted in NLO QCD from the data of COMPASS and HERMES collaborations on the semi-inclusive difference asymmetries. To this end the new method of QCD analysis (alternative to the usual global fit analysis) is applied. Using the obtained results on valence PDFs the first moments of polarized sea PDFs are reconstructed. They turn out surprisingly small: compatible with zeros within the errors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of the effects of mismatched errors on coherent beam combining based on a self-imaging waveguide

A theoretical model of coherent beam combining (CBC) based on a self-imaging waveguide (SIW) is built and the effects of mismatched errors on SIW-based CBC are simulated and analysed numerically. With the combination of the theoretical model and the finite difference beam propagation method, two main categories of errors, assembly and nonassembly errors, are numerically studied to investigate their effect on the beam quality by using the M{sup 2} factor. The optimisation of the SIW and error control principle of the system is briefly discussed. The generalised methodology offers a good reference for investigating waveguide-based high-power coherent combining of fibre lasers in a comprehensive way. (lasers and laser beams)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent). Because manufacturers’ accuracy estimates for their equipment do not include many of the sources of error found in actual field measurements (and replicated in the laboratory testing in this study) it is essential for a test method that could be used to determine the actual uncertainty in this specific application. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗