Search NASA⌕ Search

SEARCH · Search NASA

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A convergence analysis of stochastic collocation method for Navier-Stokes equations with random input data

Stochastic collocation method has proved to be an efficient method and been widely applied to solve various partial differential equations with random input data, including Navier- Stokes equations. However, up to now, rigorous convergence analyses are limited to linear elliptic and parabolic equations; its performance for Navier-Stokes equations was demonstrated mostly by numerical experiments. In this paper, we provide an error analysis of stochastic collocation method for a semi-implicit Backward Euler discretization for NSE and prove the exponential decay of the interpolation error in the probability space. Our analysis indicates that due to the nonlinearity, as final time T increases and NSE solvers pile up, the accuracy may be reduced significantly. Subsequently, the theoretical results are illustrated by the numerical test of time dependent fluid flow around a bluff body.

97 MATHEMATICS AND COMPUTING↗

Building America Case Study: Predicting Envelope Leakage in Attached Dwellings (Fact Sheet)

'The cost for blower testing is high, because it is labor intensive, and it may disrupt occupants in multiple units. This high cost and disruption deters program participants, and dissuades them from pursuing energy improvements that would trigger air leakage testing, such as improvements to the building envelope.' This statement found in a 2012 report by Heschong Mahone Group emphasizes the importance of reducing the cost and complexity of blower testing in multifamily buildings. Energy efficiency opportunities are being bypassed. The cost of single blower testing is on the order of $300. The cost for guarded blower door testing, the more appropriate test for assessing energy savings opportunities, could easily be six times that and that's only if you have the equipment and simultaneous access to multiple apartments. Thus, the proper test is simply not performed. The objective of the 2013 research project was to develop the model for predicting fully guarded test results (FGT), using unguarded test data and specific building features of apartment units. The model developed has a coefficient of determination R2 value of 0.53 with a root mean square error (RMSE) of 0.13. Both statistical metrics indicate that the model is relatively strong. When tested against data that was not included in the development of the model, prediction accuracy was within 19%, which is reasonable given that seasonal differences in blower door measurements can vary by as much as 25%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Autoencoder-Based Optical Wireless Communications Systems

In this study, we propose deep neural network autoencoders for capturing the end-to-end performance of the single- and multi-user optical wireless communications (OWC) systems. We compare the end-toend performance of the proposed autoencoders (learningbased OWC systems) with the state-of-the art model-based OWC systems in terms of the block error rate (BLER) metric. Our numerical results indicate that the proposed learning-based OWC system outperforms the model-based counterparts in both single- and multi-user settings.

99 GENERAL AND MISCELLANEOUS↗

Selection of Training Sets for 235U Source Detection Classifiers Using Gamma Signatures

The machine learning methods for classifiers to detect low level radiation sources are of interest when suitable training data sets are available. Their application and performance assessment, however, involves the aspects of over-fitting and training data selection that are somewhat uncommon in other existing methods for this task.We study U-235 gamma signatures using data sets collected by 21 NaI detectors under controlled conditions. The gamma spectra are collected by the detectors located at different distances from the source, and we study their choice as training sets for classifiers to detect a source. The detectors form the near, middle and outer groups based on the distance to source. The classifiers based on the outer group are susceptible to over-fitting, that is, they achieve low training error but incur much higher testing error in independent tests. The other two groups achieve lower training error and comparable testing error, and the near group achieves the overall lowest error. In detecting a source at an unknown distance, the farther detectors in the middle group achieve the overall lowest testing error with limited over-fitting, thereby indicating the complex dependencies between the training and classifier performance.

Rao, Nageswara↗

Mismatched DNTP Incorporation By DNA Polymerase Beta Does Not Proceed Via Globally Different Conformational Pathways

Understanding how DNA polymerases control fidelity requires elucidation of the mechanisms of matched and mismatched dNTP incorporations. Little is known about the latter because mismatched complexes do not crystallize readily. In this report, we employed small-angle X-ray scattering (SAXS) and structural modeling to probe the conformations of different intermediate states of mammalian DNA polymerase {beta} (Pol {beta}) in its wild-type and an error-prone variant, I260Q. Our structural results indicate that the mismatched ternary complex lies in-between the open and the closed forms, but more closely resembles the open form for WT and the closed form for I260Q. On the basis of molecular modeling, this over-stabilization of mismatched ternary complex of I260Q is likely caused by formation of a hydrogen bonding network between the side chains of Gln{sup 260}, Tyr{sup 296}, Glu{sup 295} and Arg{sup 258}, freeing up Asp{sup 192} to coordinate MgdNTP. These results argue against recent reports suggesting that mismatched dNTP incorporations follow a conformational path distinctly different from that of matched dNTP incorporation, or that its conformational closing is a major contributor to fidelity.

08 HYDROGEN↗

Development of the Delphi display concept for alternative explanations decision making support - 120

Human operators of advanced technology systems, such as nuclear power, command and control, and deepwater oil drilling, must be able to evaluate and respond to a wide array of operational anomalies. Unfortunately, these circumstances are often complex and ambiguous, complicating decision making tasks. One common decision making error, called confirmation bias, occurs when decision makers prematurely focus on one explanation instead of systematically considering all plausible alternative explanations that could equally well account for an operational anomaly (Nickerson, 1998). The Delphi display is designed to counteract decision makers' tendencies towards confirmation bias and to encourage them to consider all plausible explanations, including high risk explanations, they might otherwise overlook. An initial Delphi display prototype was designed to help identify the underlying cause of operational anomalies in the complex, high-consequence technology of deepwater drilling. This prototype decision aid incorporates major indicators related to operational anomalies and presents corresponding plausible explanations for each indicator, ranging from high-risk system-critical explanations to lower-risk but still significant events. The Delphi display incorporates several innovative features to help decision makers detect and monitor operational anomalies and view the relationships among indicators and their associated plausible explanations. Preliminary evaluations of an early prototype Delphi display for detecting kicks in deepwater oil drilling operations have been promising. Moreover, the methodology used to design and develop the Delphi display can be readily generalized to numerous other operational contexts that require humans to make system-critical decisions. To illustrate, an initial Delphi display design for nuclear power plant control is described. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A distributed temperature profiling system for vertically and laterally dense acquisition of soil and snow temperature

Abstract. Measuring soil and snow temperature with high vertical and lateral resolution is critical for advancing the predictive understanding of thermal and hydro-biogeochemical processes that govern the behavior of environmental systems. Vertically resolved soil temperature measurements enable the estimation of soil thermal regimes, frozen-/thawed-layer thickness, thermal parameters, and heat and/or water fluxes. Similarly, they can be used to capture the snow depth and the snowpack thermal parameters and fluxes. However, these measurements are challenging to acquire using conventional approaches due to their total cost, their limited vertical resolution, and their large installation footprint. This study presents the development and validation of a novel distributed temperature profiling (DTP) system that addresses these challenges. The system leverages digital temperature sensors to provide unprecedented, finely resolved depth profiles of temperature measurements with flexibility in system geometry and vertical resolution. The integrated miniaturized logger enables automated data acquisition, management, and wireless transfer. A novel calibration approach adapted to the DTP system confirms the factory-assured sensor accuracy of ±0.1 ∘C and enables improving it to ±0.015 ∘C. Numerical experiments indicate that, under normal environmental conditions, an additional error of 0.01 % in amplitude and 70 s time delay in amplitude for a diurnal period can be expected, owing to the DTP housing. We demonstrate the DTP systems capability at two field sites, one focused on understanding how snow dynamics influence mountainous water resources and the other focused on understanding how soil properties influence carbon cycling. Results indicate that the DTP system reliably captures the dynamics in snow depth and soil freezing and thawing depth, enabling advances in understanding the intensity and timing in surface processes and their impact on subsurface thermohydrological regimes. Overall, the DTP system fulfills the needs for data accuracy, minimal power consumption, and low total cost, enabling advances in the multiscale understanding of various cryospheric and hydro-biogeochemical processes.

54 ENVIRONMENTAL SCIENCES↗

SU-E-P-13: Quantifying the Geometric Error Due to Irregular Motion in Four-Dimensional Computed Tomography (4DCT)

Purpose: Respiratory correlated 4DCT images are generated under the assumption of a regular breathing cycle. This study evaluates the error in 4DCT-based target position estimation in the presence of irregular respiratory motion. Methods: A custom-made programmable externally-and internally-deformable lung motion phantom was placed inside the CT bore. An abdominal pressure belt was placed around the phantom to mimic clinical 4DCT acquisitio and the motion platform was programmed with a sinusoidal (±10mm, 10 cycles per minute) motion trace and 7 motion traces recorded from lung cancer patients. The same setup and motion trajectories were repeated in the linac room and kV fluoroscopic images were acquired using the on-board imager. Positions of 4 internal markers segmented from the 4DCT volumes were overlaid upon the motion trajectories derived from the fluoroscopic time series to calculate the difference between estimated (4DCT) and “actual” (kV fluoro) positions. Results: With a sinusoidal trace, absolute errors of the 4DCT estimated markers positions vary between 0.78mm and 5.4mm and RMS errors are between 0.38mm to 1.7mm. With irregular patient traces, absolute errors of the 4DCT estimated markers positions increased significantly by 100 to 200 percent, while the corresponding RMS error values have much smaller changes. Significant mismatches were frequently found at peak-inhale or peak-exhale phase. Conclusion: As expected, under conditions of well-behaved, periodic sinusoidal motion, the 4DCT yielded much better estimation of marker positions. When an actual patient trace is used 4DCT-derived positions showed significant mismatches with the fluoroscopic trajectories, indicating the potential for geometric and therefore dosimetric errors in the presence of cycle-to-cycle respiratory variations.

60 APPLIED LIFE SCIENCES↗

Development of Constitutive Relationship for Thermomechanical Processing of Al-SiC Composite Eliminating Deformation Heating

Constitutive equations are useful for computational or numerical tools in describing the thermomechanical behavior of Al/SiC composites to develop the lightweight component using bulk metal forming. In this study, the uniaxial compression test of powder metallurgy-based Al/7 vol.% SiCp composite samples in the temperature range of 250-500 °C and at the strain rates of 0.001, 0.007, 0.05, 0.3, 2.2 and 15 s{sup −1} was performed on a Gleeble-3800 thermomechanical simulator. An equation correlating actual (measured) temperature with the true stress in real time has been established for each of the strain rates. Further, the true stress was corrected by eliminating the effect of deformation heating using this equation based on the experimental observations. The temperature-corrected true stress data were then used for development of constitutive equations using the Arrhenius model, strain-compensated Arrhenius model and modified Johnson–Cook (m-JC) model. The material parameters in the m-JC model were calculated at different combinations of temperatures and strain rates. The established constitutive equations are validated with temperature-corrected true stress from the experiment. Further, these equations are verified with the experimental true stress that was obtained using different inputs of temperatures and strain rates in a compression test. The correlation coefficient (R) and absolute average relative error reflect the accuracy of constitutive models. The result indicates that the calculated true stress by the established strain-compensated Arrhenius model is in good agreement with that of experimentally measured true stress with a correlation coefficient of 0.996 and relative error of 3.83%.

36 MATERIALS SCIENCE↗

Estimation of stochastic volatility with long memory for index prices of FTSE Bursa Malaysia KLCI

In recent years, modeling in long memory properties or fractionally integrated processes in stochastic volatility has been applied in the financial time series. A time series with structural breaks can generate a strong persistence in the autocorrelation function, which is an observed behaviour of a long memory process. This paper considers the structural break of data in order to determine true long memory time series data. Unlike usual short memory models for log volatility, the fractional Ornstein-Uhlenbeck process is neither a Markovian process nor can it be easily transformed into a Markovian process. This makes the likelihood evaluation and parameter estimation for the long memory stochastic volatility (LMSV) model challenging tasks. The drift and volatility parameters of the fractional Ornstein-Unlenbeck model are estimated separately using the least square estimator (lse) and quadratic generalized variations (qgv) method respectively. Finally, the empirical distribution of unobserved volatility is estimated using the particle filtering with sequential important sampling-resampling (SIR) method. The mean square error (MSE) between the estimated and empirical volatility indicates that the performance of the model towards the index prices of FTSE Bursa Malaysia KLCI is fairly well.

97 MATHEMATICS AND COMPUTING↗

Sequence polymorphism in an insect RNA virus field population: A snapshot from a single point in space and time reveals stochastic differences among and within individual hosts

Population structure of Homalodisca coagulata Virus-1 (HoCV-1) among and within field-collected insects sampled from a single point in space and time was examined. Polymorphism in complete consensus sequences among single-insect isolates was dominated by synonymous substitutions. The mutant spectrum of the C2 helicase region within each single-insect isolate was unique and dominated by nonsynonymous singletons. Bootstrapping was used to correct the within-isolate nonsynonymous:synonymous arithmetic ratio (N:S) for RT-PCR error, yielding an N:S value ~one log-unit greater than that of consensus sequences. Probability of all possible single-base substitutions for the C2 region predicted N:S values within 95% confidence limits of the corrected within-isolate N:S when the only constraint imposed was viral polymerase error bias for transitions over transversions. These results indicate that bottlenecks coupled with strong negative/purifying selection drive consensus sequences toward neutral sequence space, and that most polymorphism within single-insect isolates is composed of newly-minted mutations sampled prior to selection. -- Highlights: •Sampling protocol minimized differential selection/history among isolates. •Polymorphism among consensus sequences dominated by negative/purifying selection. •Within-isolate N:S ratio corrected for RT-PCR error by bootstrapping. •Within-isolate mutant spectrum dominated by new mutations yet to undergo selection.

60 APPLIED LIFE SCIENCES↗

SU-E-T-602: Patient-Specific Online Dose Verification Based On Transmission Detector Measurements

Purpose: Intensity modulated radiotherapy requires a comprehensive quality assurance program in general and ideally independent verification of dose delivery. Since conventional 2D detector arrays allow only pre-treatment verification, there is a debate concerning the need of online dose verification. This study presents the clinical performance, including dosimetric plan verification in 2D as well as in 3D and the error detection abilities of a new transmission detector (TD) for online dose verification of 6MV photon beam. Methods: To validate the dosimetric performance of the new device, dose reconstruction based on TD measurements were compared to a conventional pre-treatment verification method (reference) and treatment planning system (TPS) for 18 IMRT and VMAT treatment plans. Furthermore, dose reconstruction inside the patient based on TD read-out was evaluated by comparing various dose volume indices and 3D gamma evaluations against independent dose computation and TPS. To investigate the sensitivity of the new device, different types of systematic and random errors for leaf positions and linac output were introduced in IMRT treatment sequences. Results: The 2D gamma index evaluation of transmission detector based dose reconstruction showed an excellent agreement for all IMRT and VMAT plans compared to reference measurements (99.3±1.2)% and TPS (99.1±0.7)%. Good agreement was also obtained for 3D dose reconstruction based on TD read-out compared to dose computation (mean gamma value of PTV = 0.27±0.04). Only a minimal dose underestimation within the target volume was observed when analyzing DVH indices (<1%). Positional errors in leaf banks larger than 1mm and errors in linac output larger than 2% could clearly identified with the TD. Conclusion: Since 2D and 3D evaluations for all IMRT and VMAT treatment plans were in excellent agreement with reference measurements and dose computation, the new TD is suitable to qualify for routine treatment plan verification. Funding Support, Disclosures, and Conflict of Interest: COIs: Frank Lohr: Elekta: research grant, travel grants, teaching honoraria IBA: research grant, travel grants, teaching honoraria, advisory board C-Rad: board honoraria, travel grants Frederik Wenz: Elekta: research grant, teaching honoraria, consultant, advisory board Zeiss: research grant, teaching honoraria, patent Hansjoerg Wertz: Elekta: research grant, teaching honoraria IBA: research grant.

61 RADIATION PROTECTION AND DOSIMETRY↗

A real time dose monitoring and dose reconstruction tool for patient specific VMAT QA and delivery

Purpose: To develop a real time dose monitoring and dose reconstruction tool to identify and quantify sources of errors during patient specific volumetric modulated arc therapy (VMAT) delivery and quality assurance. Methods: The authors develop a VMAT delivery monitor tool called linac data monitor that connects to the linac in clinical mode and records, displays, and compares real time machine parameters with the planned parameters. A new measure, called integral error, keeps a running total of leaf overshoot and undershoot errors in each leaf pair, multiplied by leaf width, and the amount of time during which the error exists in monitor unit delivery. Another tool reconstructs Pinnacle{sup 3} Trade-Mark-Sign format delivered plan based on the saved machine logfile and recalculates actual delivered dose in patient anatomy. Delivery characteristics of various standard fractionation and stereotactic body radiation therapy (SBRT) VMAT plans delivered on Elekta Axesse and Synergy linacs were quantified. Results: The MLC and gantry errors for all the treatment sites were 0.00 {+-} 0.59 mm and 0.05 {+-} 0.31 Degree-Sign , indicating a good MLC gain calibration. Standard fractionation plans had a larger gantry error than SBRT plans due to frequent dose rate changes. On average, the MLC errors were negligible but larger errors of up to 6 mm and 2.5 Degree-Sign were seen when dose rate varied frequently. Large gantry errors occurred during the acceleration and deceleration process, and correlated well with MLC errors (r= 0.858, p= 0.0004). PTV mean, minimum, and maximum dose discrepancies were 0.87 {+-} 0.21%, 0.99 {+-} 0.59%, and 1.18 {+-} 0.52%, respectively. The organs at risk (OAR) doses were within 2.5%, except some OARs that showed up to 5.6% discrepancy in maximum dose. Real time displayed normalized total positive integral error (normalized to the total monitor units) correlated linearly with MLC (r= 0.9279, p < 0.001) and gantry errors (r= 0.742, p= 0.005). There is a strong correlation between total integral error and PTV mean (r= 0.683, p= 0.015), minimum (r= 0.6147, p= 0.033), and maximum dose (r= 0.6038, p= 0.0376). Conclusions: Errors may exist during complex VMAT planning and delivery. Linac data monitor is capable of detecting and quantifying mechanical and dosimetric errors at various stages of planning and delivery.

60 APPLIED LIFE SCIENCES↗

Method of Determining the Reliability of Real-Time In-reactor Monitoring of VVER

A methodological approach and the basic tenets for evaluating the reliability of in-reactor monitoring of VVER are presented. The method is based on the statistical analysis of indications in real time and includes methods for evaluating the admissible maximum error of the measurement channels used for monitoring as well as the average value and admissible deviation of indications in groups of parallel monitoring channels, as well as a method of evaluating reliability by comparing the values of a parameter with the regime values. In comparing the indications of a monitoring channel with the indications of other parallel channels, the median value is proposed as the baseline value. The developed method is implemented in the Diagnostika SVRK special software, which has been successfully tested during the commissioning of the No. 1 unit at the Novovoronezh NPP-2.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Gompertzian stochastic model with delay effect to cervical cancer growth

In this paper, a Gompertzian stochastic model with time delay is introduced to describe the cervical cancer growth. The parameters values of the mathematical model are estimated via Levenberg-Marquardt optimization method of non-linear least squares. We apply Milstein scheme for solving the stochastic model numerically. The efficiency of mathematical model is measured by comparing the simulated result and the clinical data of cervical cancer growth. Low values of Mean-Square Error (MSE) of Gompertzian stochastic model with delay effect indicate good fits.

60 APPLIED LIFE SCIENCES↗

Diagnosing nuclear power plant pipe wall thinning due to flow accelerated corrosion using a passive, thermal non-destructive evaluation method: Feasibility assessment via numerical experiments

Flow accelerated corrosion (FAC) in nuclear power plant pipes is one of the leading causes of accidents, fatalities, damage and outages. Current FAC identification methods employ expensive sensing technology and are “active” methods, where the response of the piping system to an externally-generated thermal, mechanical or optical excitation must be measured. As a result, these techniques require a disruptive and time-consuming setup. Here we propose a method that utilizes pipe surface temperature measurements to passively monitor for FAC-induced pipe wall thinning without the need for expensive equipment or post-installation setup time. This diagnostic method utilizes a simulation data-driven diagnostic model to estimate the amount of thickness reduction in a pipe based on changes in measured steady-state pipe temperatures. In order to reduce the computational burden of generating large, simulation-based datasets, the behavior of the insulation of the pipe was modeled using a suitably calibrated heat transfer boundary parameter. Additionally, global sensitivity analysis was performed to determine system parameter(s), such as the temperature of water flowing inside the pipe, which significantly affect the steady state pipe wall temperature and could cause errors in diagnosis. Two diagnostic models, one using only the change in steady-state temperature as an indicator for FAC-induced pipe wall thinning and the other using water temperature as an additional diagnostic model input were evaluated for their ability to estimate thickness reductions in a pipe using simulated pipe wall temperature data. For the numerical experiments conducted in this work, both models estimated wall thickness with errors within 0.5 mm, indicating that the proposed technique can potentially be used as a low-cost, first-pass method for FAC monitoring.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of Land Surface Model Performance in WRF for Simulating Wind at Heights Relevant to the Wind Energy Community

The Weather Research and Forecasting (WRF) model was used to investigate the impact of land surface model (LSM) physics on the simulated surface energy balance and the near surface wind profile, including heights reached by a modern wind turbine. Simulations were made for a domain centered over the Department of Energy (DOE) Southern Great Plains (SGP) Atmospheric Radiation Measurement Program (ARM) Central Facility in northern Oklahoma. High-resolution measurements of surface fluxes and profiles of wind speed, direction and turbulence were available for model validation. We tested 10 common LSM configurations in WRF including Noah, Noah-MP, SSiB, Pleim-Xiu, RUC, and others to evaluate (1) the accuracy of simulated surface energy fluxes, (2) the accuracy of forecasted rotor-disk height wind speeds, and (3) the sensitivity of rotor disk wind speed to the choice of LSM. WRF was run for four, two-week periods covering different canopy, surface meteorology and soil moisture conditions. LSM performances varied by simulation period and errors were greatest during periods with high soil moisture and live crop cover, indicating highest LSM sensitivity when PBL behavior is most coupled to land-atmosphere exchange. Higher wind speed errors also occurred at night during the spring, possibly from the difficulty with simulating nocturnal low-level jets. We found that choice of land surface model led to a ~10% improvement in simulating hub-height wind speed. Errors in wind shear were also sensitive to the choice of LSM. Overall the best performing models were Noah and Noah-MP. The variability of LSM performance across different soil moisture and vegetation canopy conditions suggests LSM representation of surface energy exchange processes in WRF remains a large source of model uncertainty. Furthermore, our results indicate the choice of LSM impacts simulated wind fields in WRF at heights relevant to the wind industry, at least for the Southern Great Plains region.

17 WIND ENERGY↗

Correction of confidence intervals in excess relative risk models using Monte Carlo dosimetry systems with shared errors

Introduction: Measurement errors are ubiquitous in epidemiological studies, especially for doses arising from environmental and occupational exposures, which are difficult to assess. Correction methods for independent measurement errors, have been comprehensively described elsewhere, including regression calibration, simulation extrapolation (SIMEX), etc. However, when exposure estimates are constructed using complicated physical and biological models, uncertainties in the dosimetry system can become very complex. In such systems, uncertainties in some parameters may affect a large group of study participants simultaneously, and hence are “shared” as opposed to independent dosimetric uncertainties. Representing the structure of the uncertainty in the dosimetry by providing multiple realizations of possible dose has been described for several studies. The goal of this paper is to implement, and explore the properties of, a generalized estimating equation-based approach to shared uncertainties based on principles described in an earlier paper. Methods: The effects of shared and unshared dosimetry error on parameter estimates and confidence intervals in a generalized excess relative risk model are examined. A post-hoc correction method is implemented that constructs corrected confidence intervals based on an underlying variance structure described in an earlier paper. In this correction method it is assumed that the estimated slope parameter in a linear excess relative risk model is distributed as a mixture of normal and lognormal components. A simulation study of the behavior of this correction was developed based on multiple realizations provided by the Monte Carlo dosimetry system used for the plutonium exposures in the Mayak Worker Cohort and a risk model with close similarity to that used in analyses of lung cancer data in that cohort. Results: In the simulation study we found that shared dose errors severely degraded the coverage probabilities of confidence limits for the slope parameter in the linear excess relative risk model relating uncertain exposure to lung cancer risk. Using our correction method to adjust the confidence intervals provided much improved coverage probabilities for this parameter. A smaller amount of degradation in confidence interval coverage for other parameters (e.g. those in the baseline and dose modification terms) was noted, and the proposed correction method also improved coverage for these parameters as well. Discussion: Compared to other recently described methods our proposed correction method relies on relatively familiar software to fit dose response models. The basic modeling philosophy described here first uses existing Poisson regression methods to estimate parameters in the excess relative risk model; in this first stage mean dose (computed from the multiple realizations) is used as the independent variable in the regression. Once the model is fit we then correct (widen) the standard errors for all parameters using the proposed correction method. The simulation studies indicate that the methods described here are an important contribution to the available tools for dealing with shared measurement errors in complex risk analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗