Search NASA⌕ Search

SEARCH · Search NASA

Results for “error quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Subsampling of Parametric Models with Bifidelity Boosting

Least squares regression is a ubiquitous tool for building emulators (a.k.a. surrogate models) of problems across science and engineering for purposes such as design space exploration and uncertainty quantification. When the regression data are generated using an experimental design process (e.g., a quadrature grid) involving computationally expensive models, or when the data size is large, sketching techniques have shown promise at reducing the cost of the construction of the regression model while ensuring accuracy comparable to that of the full data. However, random sketching strategies, such as those based on leverage scores, lead to regression errors that are random and may exhibit large variability. To mitigate this issue, we present a novel boosting approach that leverages cheaper, lower-fidelity data of the problem at hand to identify the best sketch among a set of candidate sketches. This in turn specifies the sketch of the intended high-fidelity model and the associated data. We provide theoretical analyses of this bifidelity boosting (BFB) approach and discuss the conditions the low- and high-fidelity data must satisfy for a successful boosting. In doing so, we derive a bound on the residual norm of the BFB sketched solution relating it to its ideal, but computationally expensive, high-fidelity boosted counterpart. Finally, empirical results on both manufactured and PDE data corroborate the theoretical analyses and illustrate the efficacy of the BFB solution in reducing the regression error, as compared to the nonboosted solution.

97 MATHEMATICS AND COMPUTING↗

Uncertainty Quantification in the Fusion Simulation Project Verification and Validation Activity

Uncertainty quantification (UQ) is an important component of any investigation of the behavior of a complex, multi-physics system. UQ is the complete study of the accuracy, reliability, and errors in deriving scientific inferences. UQ impacts both the experimental and modeling (analytical theory and numerical simulation) approaches to studying the behavior of complex systems. UQ is essential in quantifying the nature of model and code verification and validation. Although UQ is an evolving and expanding research area, there is much experience and many mature tools already in existence. Thus, a new undertaking like the Fusion Simulation Project, with goals to develop a suite of predictive computer models for complex magnetic fusion plasma behavior and to validate this suite against experimental observations, will need to make thorough use of existing UQ methodologies and motivate the development of new techniques. This document presents an overview of UQ including some examples of successful practices and some recommendations for defining UQ practices in the Fusion Simulation Project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-temperature-superposition analysis of diverse datasets by the minimum-arclength method: long-term prediction with uncertainty margins

In a recent publication, we carried out an extensive analysis of an unsupervised method of determining optimum shift factors in time-temperature-superposition of accelerated-aging data that involves minimizing the vertical arclength to obtain the master curve. For synthetic Arrhenius data with a variety of noise distributions, the work showed that, in conjunction with bootstrap-resampling, the method can produce reliable estimates of the mean activation energy along with uncertainty quantification. Here, we apply the above method to six different datasets taken from the published literature and demonstrate accurate prediction of mean activation energy from the data as-is without the need for any pre-processing or fitting. We also compare uncertainty margins computed by second-order bootstrap with that by linear regression theory and show that the former appears to provide consistent margins in the presence of common noise types in real data, including intra-isotherm measurement-errors, sample-to-sample variations, and intrinsic deviation from perfect Arrhenius behavior.

36 MATERIALS SCIENCE↗

Determination of a Generic Human Error Probability Distribution, Part 1: A Dynamic Formulation of SPAR-H

In almost all major nuclear power plants (NPP) events include a significant human error component. As an example, in Fukushima Daiichi (2011) nuclear meltdown, the human actions related to the high-pressure injection cooling strongly affected accident evolution. Furthermore, in the Three Mile Island accident (1979) (which was initiated by a stuck open valve and thus was triggered a loss of coolant accident) the unit operators made decisions based upon false assumptions that contributed negatively to the accident. Given these premises, the ability to accurately model human interactions with plant evolution and, in particular, dynamically calculate human error probability (HEP) plays a major role in a probabilistic risk analysis (PRA). Human reliability analysis (HRA) identifies and models the causes of human errors, and quantifies HEP by applying different methodologies. HRA methods identify errors and reflect on the understanding of error-prone people and systems. There are a number of HRA methods available that assist in identifying the vulnerabilities in the system and provide guidance in determining the HEP. HEP is the probability of a human failure event (HFE), and quantification of HEPs under various situations is utilized in PRA of large complex systems. One of the more prominent HRA methods is the Standardized Plant Analysis Risk-Human Reliability Analysis (SPAR-H) method that was developed to estimate HEPs for the use in the Standardized Plant Analysis Risk (SPAR) PRA models employed in U.S. NPPs. SPAR-H is implemented in U.S. NPPs by regulators at the U.S. Nuclear Regulatory Commission (NRC) to determine the HEP based on expert estimation through the use of calculation worksheets. In SPAR-H, the nominal HEPs (NHEPs) are multiplied by performance shaping factors (PSF) multiplier values to obtain the overall error probability. PSFs encompass the human components, individual characteristics, their environment, and aspects of the task. With PSFs, the goal is to capture all factors that can affect human performance. In SPAR-H there are eight PSFs used, each having respective levels corresponding to multipliers: Available Time, Stress/Stressors, Complexity, Experience/Training, Procedures, Ergonomics/Human Machine Interface, Fitness for Duty, and Work Processes. The PSF multipliers indicate enhanced, nominal, or degraded human performance. The SPAR-H method estimates the HEP through multiplying a NHEP with PSFs. Hence, SPAR-H is a traditional HRA method that assesses human performance at a fixed, or static, point in time. In a dynamic HRA framework, human performance is assessed on a continuous time basis. SPAR-H can be used within a dynamic PRA framework through the use of simulation and stochastic models. The goal of dynamic HRA is to build a more realistic model of the human-system interaction to enhance calculation of reliability, risk and safety analysis. The progression of events in dynamic SPAR-H considers that some PSFs may experience gradual change, while other change can be sudden due to individualistic differences or rapid plant status changes. The PSF changes are caused by contextual changes in the scenario. For example, as more time passes, the realization that a task should be completed sooner may cause the operator more stress. In another example, a sudden relay of information about sickness of a family member may alter the operator's general stress level and fitness for duty. Each PSF has a different dynamic nature; PSFs like stress and complexity change more quickly over the course of a task than experience and training. While the experience of an operator changes over the course of attaining the objective, the amount that this added experience changes the HEP is very minimal. In contrast, the stress, complexity, and procedures PSFs may change quite a bit over the course of task completion.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nuclear Criticality Safety Integral Experiment Covariance Determination

Integral benchmarks for criticality safety and nuclear data validation require expensive uncertainty quantification studies. Commonly, the uncertainty quantification ignores correlations between experiments that share components. Experiments such as the TEX (Thermal/Epithermal eXperiments) campaigns consist of many shared parts between experiments, such as fuel, which creates a strong correlation in their errors. While these correlations are known to exist, they are often not estimated due to the complexity of such calculations. This paper describes a software package that uses an intuitive method of determining the covariance for each of the experimental components, providing a correlation matrix for each family of parts across the multiple cases examined within a benchmark. The code uses the TEX-HEU campaign as a proof of concept, and we show that the correlations can be calculated with information commonly found in ICSBEP (International Criticality Safety Benchmark Evaluation Project) benchmarks. The estimated covariances are used in χ 2 trending studies to evaluate their impact on nuclear data validation. The covariance determination code can be easily integrated into current benchmark evaluations as well as reevaluating legacy benchmark uncertainties. Uncertainty correlation calculations should become the baseline for criticality safety integral experiment benchmarks and can now be easily calculated with the described software package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Approach to Dynamic Human Reliability Analysis and Its Data Collection Framework

Human reliability analysis (HRA) is a method for evaluating human errors in a variety of complex systems such as nuclear power plants, military systems, aircraft, and chemical plants. Most HRA methods currently used by regulatory institutes or utilities are called static HRA and are carried out by simple worksheets or simple calculators. To date, there are many unsolved or intrinsic challenges in static HRA. For example, existing static HRA does not realistically model and evaluate human actions as they would be performed at actual systems. There is no method with HRA to objectively estimate the time required for human actions despite being essential to HRA processes. In addition, many HRA methods still rely on a dataset generated prior to the 1980s, from unrelated industry experience or simply from expert judgment. Accordingly, this study attempted to research how to overcome the challenges of existing HRA via dynamic risk assessment (a.k.a., simulation-based or computation-based risk assessment) techniques. First, this study developed a dynamic HRA method, named as PRocedure-based Investigation Method of EMRALD Risk Assessment – HRA (PRIMERA-HRA). The PRIMERA-HRA mainly concentrates on providing HRA analysts with specific guidelines on how to reasonably model human actions, assign human reliability data and evaluate output of simulation within a dynamic probabilistic risk assessment tool, called as Event Modeling Risk Assessment using Linked Diagrams (EMRALD). Second, this study also developed a module for performance shaping factors (i.e., the key concept in HRA quantification) applicable to dynamic HRA, then implemented it based on PRIMERA-HRA within the EMRALD tool. Third, this study developed an HRA data collection framework to support dynamic HRA, called as Simplified Human Error Experimental Program (SHEEP). Originally, the SHEEP study aimed to support static HRA and its data collection, but recently extended the scope to the new technologies such as dynamic HRA or HRA for advanced reactors. SHEEP focuses on the use of data collected from simplified simulators to complement—but not replace—data collection studies using full-scope simulators and actual operators. To date, many experiments were conducted under the SHEEP framework. Multiple analyses, such as human performance analysis, human error analysis, task complexity analysis, learning effect analysis and time distribution analysis, were also carried out using the collected data. Then, based on the major insights, an approach to inferring full-scope data based on simplified simulator data was proposed. The PRIMERA-HRA and SHEEP research are expected to evaluate human actions more realistically than existing static HRA, provide an opportunity to collect more HRA data with reasonable cost and labor, then contribute to enhance the quality of HRA.

99 - GENERAL AND MISCELLANEOUS↗

An Approach to Dynamic Human Reliability Analysis and Its Data Collection Framework

Human reliability analysis (HRA) is a method for evaluating human errors in a variety of complex systems such as nuclear power plants, military systems, aircraft, and chemical plants. Most HRA methods currently used by regulatory institutes or utilities are called static HRA and are carried out by simple worksheets or simple calculators. To date, there are many unsolved or intrinsic challenges in static HRA. For example, existing static HRA does not realistically model and evaluate human actions as they would be performed at actual systems. There is no method with HRA to objectively estimate the time required for human actions despite being essential to HRA processes. In addition, many HRA methods still rely on a dataset generated prior to the 1980s, from unrelated industry experience or simply from expert judgment. Accordingly, this study attempted to research how to overcome the challenges of existing HRA via dynamic risk assessment (a.k.a., simulation-based or computation-based risk assessment) techniques. First, this study developed a dynamic HRA method, named as PRocedure-based Investigation Method of EMRALD Risk Assessment – HRA (PRIMERA-HRA). The PRIMERA-HRA mainly concentrates on providing HRA analysts with specific guidelines on how to reasonably model human actions, assign human reliability data and evaluate output of simulation within a dynamic probabilistic risk assessment tool, called as Event Modeling Risk Assessment using Linked Diagrams (EMRALD). Second, this study also developed a module for performance shaping factors (i.e., the key concept in HRA quantification) applicable to dynamic HRA, then implemented it based on PRIMERA-HRA within the EMRALD tool. Third, this study developed an HRA data collection framework to support dynamic HRA, called as Simplified Human Error Experimental Program (SHEEP). Originally, the SHEEP study aimed to support static HRA and its data collection, but recently extended the scope to the new technologies such as dynamic HRA or HRA for advanced reactors. SHEEP focuses on the use of data collected from simplified simulators to complement—but not replace—data collection studies using full-scope simulators and actual operators. To date, many experiments were conducted under the SHEEP framework. Multiple analyses, such as human performance analysis, human error analysis, task complexity analysis, learning effect analysis and time distribution analysis, were also carried out using the collected data. Then, based on the major insights, an approach to inferring full-scope data based on simplified simulator data was proposed. The PRIMERA-HRA and SHEEP research are expected to evaluate human actions more realistically than existing static HRA, provide an opportunity to collect more HRA data with reasonable cost and labor, then contribute to enhance the quality of HRA.

99 - GENERAL AND MISCELLANEOUS↗

Implications of CT noise and artifacts for quantitative {sup 99m}Tc SPECT/CT imaging

Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI{sub vol} = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in {sup 99m}Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI{sub vol} = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ{sub 140} {sub keV} on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed {sup 99m}Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect SPECT quantification is low (CTDI{sub vol} ∼ 4 μGy), the low dose limit for the CT exam as part of SPECT/CT will be guided by CT image quality requirements for anatomical localization and artifact reduction. A CT technique with higher kVp in combination with lower mAs is recommended when low-dose CT images are used for AC to minimize beam-hardening artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An improved multilevel Monte Carlo method for estimating probability distribution functions in stochastic oil reservoir simulations

In this paper, we develop an improved multilevel Monte Carlo (MLMC) method for estimating cumulative distribution functions (CDFs) of a quantity of interest, coming from numerical approximation of large-scale stochastic subsurface simulations. Compared with Monte Carlo (MC) methods, that require a significantly large number of high-fidelity model executions to achieve a prescribed accuracy when computing statistical expectations, MLMC methods were originally proposed to significantly reduce the computational cost with the use of multifidelity approximations. The improved performance of the MLMC methods depends strongly on the decay of the variance of the integrand as the level increases. However, the main challenge in estimating CDFs is that the integrand is a discontinuous indicator function whose variance decays slowly. To address this difficult task, we approximate the integrand using a smoothing function that accelerates the decay of the variance. In addition, we design a novel a posteriori optimization strategy to calibrate the smoothing function, so as to balance the computational gain and the approximation error. The combined proposed techniques are integrated into a very general and practical algorithm that can be applied to a wide range of subsurface problems for high-dimensional uncertainty quantification, such as a fine-grid oil reservoir model considered in this effort. The numerical results reveal that with the use of the calibrated smoothing function, the improved MLMC technique significantly reduces the computational complexity compared to the standard MC approach. Finally, we discuss several factors that affect the performance of the MLMC method and provide guidance for effective and efficient usage in practice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescent amplification for next generation sequencing (FA-NGS) library preparation

BACKGROUND: Next generation sequencing (NGS) has become a universal practice in modern molecular biology. As the throughput of sequencing experiments increases, the preparation of conventional multiplexed libraries becomes more labor intensive. Conventional library preparation typically requires quality control (QC) testing for individual libraries such as amplification success evaluation and quantification, none of which occur until the end of the library preparation process. RESULTS: In this study, we address the need for a more streamlined high-throughput NGS workflow by tethering real-time quantitative PCR (qPCR) to conventional workflows to save time and implement single tube and single reagent QC. We modified two distinct library preparation workflows by replacing PCR and quantification with qPCR using SYBR Green I. qPCR enabled individual library quantification for pooling in a single tube without the need for additional reagents. Additionally, a melting curve analysis was implemented as an intermediate QC test to confirm successful amplification. Sequencing analysis showed comparable percent reads for each indexed library, demonstrating that pooling calculations based on qPCR allow for an even representation of sequencing reads. To aid the modified workflow, a software toolkit was developed and used to generate pooling instructions and analyze qPCR and melting curve data. CONCLUSIONS: We successfully applied fluorescent amplification for next generation sequencing (FA-NGS) library preparation to both plasmids and bacterial genomes. As a result of using qPCR for quantification and proceeding directly to library pooling, the modified library preparation workflow has fewer overall steps. Therefore, we speculate that the FA-NGS workflow has less risk of user error. The melting curve analysis provides the necessary QC test to identify and troubleshoot library failures prior to sequencing. While this study demonstrates the value of FA-NGS for plasmid or gDNA libraries, we speculate that its versatility could lead to successful application across other library types.

59 BASIC BIOLOGICAL SCIENCES↗

(Doublon) Benchmarking of Different Inverse Point Kinetics Implementations for an Autocorrected Reactimeter Algorithm

In November 2017, the Transient Reactor Test Facility returned to operation. Since that time, many transient test series have been completed, such as the Transient Heatsink Overpower Response capsule (THOR), the Transient Water Irradiation System for TREAT (TWIST), and Sirius. Each has provided valuable data for materials performance and reactor safety that can be applied in future designs. During each experimental series, detector count rates provided important information on the core behavior during transients. However, a limitation of these data is that variations in the neutron distribution during experiments can cause errors when attempting to infer reactivity evolution from detector signals. Neutron physics codes can be used to compute the flux shape variations. However, this is a poor solution when the experimental data is used for code verification, validation and uncertainty quantification. Indeed, if the output of the code is used both as a reference and to correct what the reference is compared to, the circular dependency limits the quality of the verification, validation and uncertainty quantification approach. To overcome this problem, the autocorrected reactimeter algorithm (ACRA) has been developed. This approach infers a time-dependent reactivity evolution by testing different spatial corrections and selecting the one that minimizes reactivity variations when the core is in a frozen configuration (i.e., when there is no variation in parameters affecting reactivity). However, the scope of this method was limited to transients where there were negligible thermal feedback. Indeed, the core is never in a frozen configuration when the fuel temperature varies during the whole transient. This is our motivation for developing an improved version of the ACRA that does not require frozen configurations. To develop this new algorithm, we need a precise and unbiased implementation of the inverse point kinetic equations (IPKEs) as any error in the reactivity evaluation will be propagated into the choice of the optimal spatial correction. Indeed, the previous reactimeter algorithm would use approximations, such as a negligible flux amplitude derivative, to focus on rapidity. For the numerical validation of ACRA, we aim at absolute error under for reactivity derived from signals similar to the one of this study. In this summary, we test eight different IPKE implementations. Each will process a mockup signal built for this study, similar to those that the future ACRA will process. Each reactivity output will be compared to the reference reactivity that has been used to generate the mockup signal. The implementation minimizing the difference with the reference reactivity will be used in the development of a new ACRA formulation.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analytic insights on the information content of new observables

Uncertainty quantification has emerged as a rapidly growing field in nuclear science. Theoretical predictions of physical observables often involve extrapolations to regions that are poorly constrained by laboratory experi- ments and astrophysical observations. Without properly quantified theoretical errors, such model predictions are of limited value. Also, one often deals with theoretical constructs that involve fundamental quantities that are not accessible to experiment or observation. Particularly relevant in this context is the pressure of pure neutron matter. Furthermore, in this Rapid Communication, we develop an analytic framework to answer the question of “How can new data reduce uncertainties of current theoretical models?” Simple and insightful expressions are obtained to quantify the impact of one or two new observables on theoretical uncertainties in two critical quantities: The slope of the symmetry energy at saturation density and the pressure of pure neutron matter at twice nuclear matter saturation density.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large-Scale Uncertainty and Error Analysis for Time-dependent Fluid/Structure Interactions in Wind Turbine Applications

The following is the final report covering the entire period of this aforementioned grant, June 1, 2011 - May 31, 2013 for the portion of the effort corresponding to Stanford University (SU). SU has partnered with Sandia National Laboratories (PI: Mike S. Eldred) and Purdue University (PI: Dongbin Xiu) to complete this research project and this final report includes those contributions made by the members of the team at Stanford. Dr. Eldred is continuing his contributions to this project under a no-cost extension and his contributions to the overall effort will be detailed at a later time (once his effort has concluded) on a separate project submitted by Sandia National Laboratories. At Stanford, the team is made up of Profs. Alonso, Iaccarino, and Duraisamy, post-doctoral researcher Vinod Lakshminarayan, and graduate student Santiago Padron. At Sandia National Laboratories, the team includes Michael Eldred, Matt Barone, John Jakeman, and Stefan Domino, and at Purdue University, we have Prof. Dongbin Xiu as our main collaborator. The overall objective of this project was to develop a novel, comprehensive methodology for uncertainty quantification by combining stochastic expansions (nonintrusive polynomial chaos and stochastic collocation), the adjoint approach, and fusion with experimental data to account for aleatory and epistemic uncertainties from random variable, random field, and model form sources. The expected outcomes of this activity were detailed in the proposal and are repeated here to set the stage for the results that we have generated during the time period of execution of this project: 1. The rigorous determination of an error budget comprising numerical errors in physical space and statistical errors in stochastic space and its use for optimal allocation of resources; 2. A considerable increase in efficiency when performing uncertainty quantification with a large number of uncertain variables in complex non-linear multi-physics problems; 3. A solution to the long-time integration problem of spectral chaos approaches; 4. A rigorous methodology to account for aleatory and epistemic uncertainties, to emphasize the most important variables via dimension reduction and dimension-adaptive refinement, and to support fusion with experimental data using Bayesian inference; 5. The application of novel methodologies to time-dependent reliability studies in wind turbine applications including a number of efforts relating to the uncertainty quantification in vertical-axis wind turbine applications. In this report, we summarize all accomplishments in the project (during the time period specified) focusing on advances in UQ algorithms and deployment efforts to the wind turbine application area. Detailed publications in each of these areas have also been completed and are available from the respective conference proceedings and journals as detailed in a later section.

97 MATHEMATICS AND COMPUTING↗

Thinking Bayesian for plasma physicists

Bayesian statistics offers a powerful technique for plasma physicists to infer knowledge from the heterogeneous data types encountered. To explain this power, a simple example, Gaussian Process Regression, and the application of Bayesian statistics to inverse problems are explained. The likelihood is the key distribution because it contains the data model, or theoretic predictions, of the desired quantities. By using prior knowledge, the distribution of the inferred quantities of interest based on the data given can be inferred. Because it is a distribution of inferred quantities given the data and not a single prediction, uncertainty quantification is a natural consequence of Bayesian statistics. The benefits of machine learning in developing surrogate models for solving inverse problems are discussed, as well as progress in quantitatively understanding the errors that such a model introduces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rossi-alpha Uncertainty Quantification by Analytic, Bootstrap, and Sample Methods to Inform Fitting Best Practices

The prompt neutron period (the negative reciprocal of the prompt neutron decay constant) can be estimated using the Rossi-alpha technique that is predicated on fitting Rossi alpha histograms and of interest in nuclear criticality safety and nonproliferation. The histograms are traditionally fit with a one-exponential model; however, recent work has proposed a two-exponential model to account for reflector induced phenomenon. Until recently, the uncertainty quantification for either model was inadequate (inaccurate and demanded large measurement times). Measurement uncertainty quantification by sample and analytic methods was developed and validated in Ref. The purpose of this transaction is to (i) validate a new bootstrap method by comparing bin-by-bin error bar estimates and (ii) demonstrate how to choose bin widths and reset times to optimize precision and accuracy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enrichment Meter Dataset from High-Resolution Gamma Spectroscopy Measurements of U3O8 Enrichment Standards and UF6 Cylinder Wall Equivalents

The Enrichment Meter Principle (EMP) is the basis for a commonly used standard test method for the non-destructive assay of 235 U enrichment in bulk compounds [1]. The technique involves determining the net count rate in the direct 186 keV peak using medium or high energy gamma-ray spectrometry in a fixed geometry. With suitable correction for wall attenuation, compound type, rate loss (live time), and peaked background (if significant), the atom fraction of 235 U may be obtained from the counting rate from a linear relationship through the origin. The widespread use of this method for field verification of enrichment [2,3] together with the fact that the response function rests on fundamental physics considerations (i.e., is not represented by a convenient but arbitrary form) makes it an interesting example of uncertainty quantification, one in which one can expect a valid measurement model can be applied. When applied using NaI(Tl) and region of interest analysis, the technique is susceptible to both interference error and bias [2-4]. When implemented using high-resolution gamma-ray spectroscopy, the spectrum interpretation is considerable simplified and more robust [5]. However, a practical challenge to studying the uncertainty budget of the EMP method (for example, to test linearity, extract wall corrections and so forth using modern methods) is the availability of quality experimental data that can be referenced and shared. To fill this gap, the research team undertook an experimental campaign [6]. A measurement campaign was conducted to produce high-resolution gamma spectroscopy enrichment meter data comparable to UF 6 cylinder measurements. The purpose of this report is to provide both an introduction to and quality assurance (QA) of the raw data produced. This report is intended for the analyst or researcher who uses the raw data. Unfortunately, the raw data (i.e., the spectra files) are too voluminous to include in this report but can be requested from Steven Croft of the Safeguards & Security Technology Group (scroft@ornl.gov 865-241-2834). The complete processed data are tabulated in Appendix A. The analysis techniques used to produce the QA data presented in this report [e.g., three regions-ofinterest (ROI) peak extraction and batch analysis processes] are not the most sophisticated techniques available; analysts are encouraged to reanalyze the raw data using more sensitive techniques and to improve upon the results presented here. With that being said, the analysis techniques used here are more than adequate to present and inspect the quality of the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resting myocardial blood flow quantification using contrast-enhanced magnetic resonance imaging in the presence of stenosis: A computational fluid dynamics study

Purpose: The extent to which atherosclerotic plaques affect contrast agent (CA) transport in the coronary arteries and, hence, quantification of myocardial blood flow (MBF) using magnetic resonance imaging (MRI) is unclear. The purpose of this work was to evaluate the influence of plaque induced stenosis both on CA transport and on the accuracy of MBF quantification. Methods: Computational fluid dynamics simulations in a high-detailed realistic vascular model were employed to investigate CA bolus transport in the coronary arteries. The impact of atherosclerosis was analyzed by inserting various medium- to high-grade stenoses in the vascular model. The influence of stenosis morphology was examined by varying the stenosis shapes but keeping the area reduction constant. Errors due to CA bolus transport were analyzed using the tracer-kinetic model MMID4. Results: Dispersion of the CA bolus was found in all models and for all outlets, but with a varying magnitude. The impact of stenosis was complex: while high-grade stenoses amplified dispersion, mild stenoses reduced the effect. Morphology was found to have a marked influence on dispersion for a small number of outlets in the post-stenotic region. Despite this marked influence on the concentration–time curves, MBF errors were less affected by stenosis. In total, MBF was underestimated by −7.9% to −44.9%. Conclusions: The presented results reveal that local hemodynamics in the coronary vasculature appears to have a direct impact on CA bolus dispersion. Inclusion of atherosclerotic plaques resulted in a complex alteration of this effect, with both degree of area reduction and stenosis morphology affecting the amount of dispersion. This strong influence of vascular transport effects impairs the accuracy of MRI-based MBF quantification techniques and, potentially, other bolus-based perfusion measurement techniques like computed tomography perfusion imaging.

60 APPLIED LIFE SCIENCES↗

Quantification of organ motion based on an adaptive image-based scale invariant feature method

Purpose: The availability of corresponding landmarks in IGRT image series allows quantifying the inter and intrafractional motion of internal organs. In this study, an approach for the automatic localization of anatomical landmarks is presented, with the aim of describing the nonrigid motion of anatomo-pathological structures in radiotherapy treatments according to local image contrast.Methods: An adaptive scale invariant feature transform (SIFT) was developed from the integration of a standard 3D SIFT approach with a local image-based contrast definition. The robustness and invariance of the proposed method to shape-preserving and deformable transforms were analyzed in a CT phantom study. The application of contrast transforms to the phantom images was also tested, in order to verify the variation of the local adaptive measure in relation to the modification of image contrast. The method was also applied to a lung 4D CT dataset, relying on manual feature identification by an expert user as ground truth. The 3D residual distance between matches obtained in adaptive-SIFT was then computed to verify the internal motion quantification with respect to the expert user. Extracted corresponding features in the lungs were used as regularization landmarks in a multistage deformable image registration (DIR) mapping the inhale vs exhale phase. The residual distances between the warped manual landmarks and their reference position in the inhale phase were evaluated, in order to provide a quantitative indication of the registration performed with the three different point sets.Results: The phantom study confirmed the method invariance and robustness properties to shape-preserving and deformable transforms, showing residual matching errors below the voxel dimension. The adapted SIFT algorithm on the 4D CT dataset provided automated and accurate motion detection of peak to peak breathing motion. The proposed method resulted in reduced residual errors with respect to standard SIFT, providing a motion description comparable to expert manual identification, as confirmed by DIR.Conclusions: The application of the method to a 4D lung CT patient dataset demonstrated adaptive-SIFT potential as an automatic tool to detect landmarks for DIR regularization and internal motion quantification. Future works should include the optimization of the computational cost and the application of the method to other anatomical sites and image modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗