Standardizing Naming Conventions in Radiation Oncology

Purpose: The aim of this study was to report on the development of a standardized target and organ-at-risk naming convention for use in radiation therapy and to present the nomenclature for structure naming for interinstitutional data sharing, clinical trial repositories, integrated multi-institutional collaborative databases, and quality control centers. This taxonomy should also enable improved plan benchmarking between clinical institutions and vendors and facilitation of automated treatment plan quality control. Materials and Methods: The Advanced Technology Consortium, Washington University in St. Louis, Radiation Therapy Oncology Group, Dutch Radiation Oncology Society, and the Clinical Trials RT QA Harmonization Group collaborated in creating this new naming convention. The International Commission on Radiation Units and Measurements guidelines have been used to create standardized nomenclature for target volumes (clinical target volume, internal target volume, planning target volume, etc.), organs at risk, and planning organ-at-risk volumes in radiation therapy. The nomenclature also includes rules for specifying laterality and margins for various structures. The naming rules distinguish tumor and nodal planning target volumes, with correspondence to their respective tumor/nodal clinical target volumes. It also provides rules for basic structure naming, as well as an option for more detailed names. Names of nonstandard structures used mainly for plan optimization or evaluation (rings, islands of dose avoidance, islands where additional dose is needed [dose painting]) are identified separately. Results: In addition to its use in 16 ongoing Radiation Therapy Oncology Group advanced technology clinical trial protocols and several new European Organization for Research and Treatment of Cancer protocols, a pilot version of this naming convention has been evaluated using patient data sets with varying treatment sites. All structures in these data sets were satisfactorily identified using this nomenclature. Conclusions: Use of standardized naming conventions is important to facilitate comparison of dosimetry across patient datasets. The guidelines presented here will facilitate international acceptance across a wide range of efforts, including groups organizing clinical trials, Radiation Oncology Institute, Dutch Radiation Oncology Society, Integrating the Healthcare Enterprise, Radiation Oncology domain (IHE-RO), and Digital Imaging and Communication in Medicine (DICOM).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Overview of Genomic Biomarker Use in Cardiovascular Disease Clinical Trials

Clinical trial designs targeting patient subgroups with certain genetic characteristics may enhance the efficiency of developing drugs for cardiovascular disease ( CVD ). To evaluate the extent to which genetic knowledge translates to the CVD pipeline, we analyzed how genomic biomarkers are utilized in trials. Phase II and III trial protocols for investigational new drugs for CVD and risk factors were evaluated for prospective and exploratory genomic biomarker use; drug targets were evaluated for the presence of evidence that genetic variations can impact CVD risk or drug response. We identified 134 programs (73 unique drug targets) and 147 clinical trials. Less than 1% ( n = 1/147) trials used a genomic biomarker prospectively for in‐trial enrichment despite 32% ( n = 23/73) of the drug targets having evidence of genetic variations. Additionally, 46% ( n = 68/147) of the trials specified exploratory biomarker use. The results highlight an opportunity for more targeted CVD drug development by leveraging genomic biomarker knowledge.

Adeniyi, Oluseyi↗

Effect of low tube voltage and low iodine concentration abdominal CT on image quality and radiation dose in children: preliminary study

Purpose: To evaluate the image quality of a double-low protocol (low tube voltage and low iodine concentration) for abdominal CT in children. Materials and methods: The double-low protocol was compared to the conventional protocol in pediatric patients weighing less than 40 kg from May 2016 to December 2016. Double-low protocol (Group A, n = 18): tube voltage, 70 kVp; and iodine concentration,: 250 mgI/mL versus Conventional protocol (Group B, n = 13): tube voltage, 80–100 kVp; and iodine concentration, 350 mgI/mL. Mean attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared between the two groups. Image contrast, noise, beam-hardening artifacts, and overall image quality were subjectively scored. Reader performance for correctly differentiating two groups by visual assessment was evaluated. Radiation dose and total iodine load were recorded. Results: The mean attenuations of the portal vein and liver and the mean image noise in Group A were higher than in Group B (p = 0.04, 0.03, 0.004, respectively). The mean SNR and CNR of the main portal vein and liver were lower in Group A without any statistically significant difference. There were no statistically significant differences between the two groups in qualitative analysis (image contrast, image noise, and overall image quality) with substantial agreement between the reviewers (weighted kappa values; 0.59–0.76). Significantly diminished radiation dose and iodine load were observed in Group A compared with Group B (25.0%, 36.8% reduction; p = 0.007, 0.006, respectively). Conclusion: The double-low protocol was feasible for pediatric abdominal CT and reduced both radiation dose and iodine load, while maintaining image quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cognitive behavioural therapy targeting cardiac anxiety post-myocardial infarction: results from two sequential pilot studies

Abstract Aims Cardiac anxiety, which is cardiac-related fear and avoidance behaviours, is common following myocardial infarction (MI) and has been associated with increased risk for cardiovascular events. However, there are currently no treatments specifically designed to target cardiac anxiety. The aim of the two pilot studies was to evaluate an exposure-based cognitive behavioural therapy protocol (MI-CBT) targeting cardiac anxiety following MI, assessing feasibility, acceptability, and the intervention's potential for reducing cardiac anxiety and improving health-related quality of life (QoL). Methods and results A series of two sequential, uncontrolled pilot studies were conducted. In Pilot Study 1 (n = 15), MI-CBT was delivered via face-to-face videoconference, while Pilot Study 2 (n = 23) was delivered online. Patients with a history of MI (≥6 months before assessment, type 1 ST- or non-ST-segment elevation MI, and elevated cardiac anxiety as per clinical interview) were included. The interventions lasted 8 weeks and were therapist-led, with key components including exposure to cardiac-related symptoms and reduction of avoidance behaviours. Participants completed self-rated assessments, including the Cardiac Anxiety Questionnaire (CAQ) and the 12-Item Short Form Health Survey (SF-12), at baseline, post-treatment, and 6-month follow-up. Treatment adherence and satisfaction were high. Cognitive behavioural therapy led to a large reduction in cardiac anxiety, as measured by the CAQ (P < 0.001), and significant improvements in health-related QoL, as measured by the SF-12 (P < 0.001), in both pilot studies. Conclusion These studies suggest that exposure-based CBT is a feasible, acceptable, and promising approach to reduce cardiac anxiety and improve QoL following MI. A randomized controlled trial should be conducted to evaluate the efficacy of the intervention.

Johnsson, Amanda (ORCID:0009000862983934)↗

MO-E-17A-10: Evaluation of Body and Head Dimensions of Pediatric Patients as a Function of Age

Purpose: Phantom development in medical physics plays an important role in radiation dose assessment and image quality evaluation, and this is especially true in the pediatric patient population. The purpose of this investigation was to establish the relationship between patient age and patient size, focusing on the abdomen-pelvis and head effective diameters, for patients ranging in age from newborn to 18 years. Methods: A dose reporting tool for computed tomography systems was installed at our institution to achieve compliance with state law commencing on July 1, 2012. The software records a number of patient-specific data, and also reports CT dose metrics (CTDIvol and DLP) into the patients interpretive report. The database generated by the software was mined to determine patient effective diameter as a function of age for pediatric patients aged 0–18 years. CT protocols including abdomen-pelvis and routine head were evaluated, and specific to this study the patients age, gender and equivalent diameter were recorded. Results: Six age ranges were evaluated: A(0–3), B(4–6), C(7–9), D(10–12),E(13–15),F(16–18). For the torso in these groups based upon 694 patients, median effective diameters were 147, 167, 184, 214, 231, 246 mm, respectively. For the head (N=1833), median diameters were 143, 157, 162, 168, 174, and 174, respectively. Conclusion: A solid understanding of the approximate dimensions of pediatric patients as a function of age is useful in the development of age-based imaging protocols and dose assessments. CT dose-reporting tools generate a great deal of data with respect to body dimensions automatically. In this study, median equivalent diameters for the abdomen-pelvis and head of pediatric patients were evaluated. These data may prove useful in the development of both mathematical and physical phantoms for dosimetry and image quality assessment.

60 APPLIED LIFE SCIENCES↗

Poly (lactide-co-glycolide) acid nanoencapsulation of a synthetic coumarin: Cytotoxicity and bio-distribution in mice, in cancer cell line and interaction with calf thymus DNA as target

Several naturally occurring coumarin compounds, including scopoletin (7 hydroxy-6 methoxycoumarin), of plant origin have been reported to have anti-cancer potentials. A related but chemically synthesized coumarin, 4-methyl-7-hydroxy coumarin (SC), was also shown to have similar anti-cancer potentials. In the present study, to test if nano-encapsulated SC could be a more potent anti-cancer agent, we encapsulated SC with poly lactide-co-glycolide acid (PLGA) nanoparticles (Nano Coumarin; NC) and tested its potentials with a variety of protocols. NC demonstrated greater efficiency of drug uptake and showed anti-cancer potentials in melanoma cell line A375, as revealed from scanning electronic and atomic force microscopies. To test its possible interaction with target DNA, the combined data of circular dichroism spectra (CD) and melting temperature profile (T{sub m}) of calf thymus DNA treated with NC were analyzed. Results indicated a concentration dependent interaction of NC with calf thymus DNA, bringing in effective change in structure and conformation, and forming a new complex that increased its stability. Particle size and morphology of NC determined through polydispersity index and zeta potential using dynamic light scattering qualified NC to be a more potent anti-cancer agent than SC. Further, SC and NC showed negligible cytotoxic effects on normal skin cells and peripheral blood mononuclear cells of mice. Distribution assay of PLGA nanoparticles in different tissues like brain, heart, kidneys, liver, lungs, and spleen in mice revealed the presence of nanoparticles in different tissues including brain, indicating that the particles could cross the blood brain barrier, significant information for drug design. - Graphical abstract: Nanoencapsulated coumarin (NC) were characterized for their size and morphology by scanning electron (SEM) and atomic force microscopies (AFM).The physical interaction of the NC with calf thymus DNA was studied through circular dichroism (CD) spectroscopies, using UV-visible titration and thermal denaturation studies. NC had a concentration dependent interaction with calf thymus DNA, could form a new complex with double helical DNA, increased the T{sub m} value and altered CD spectra of DNA and showed stronger anti-cancer effect than synthetic coumarin. Display Omitted Research Highlights: > Strategy for PLGA nano-encapsulation of a bioactive synthetic coumarin, 4 methyl 7 hydroxy coumarin (SC) is formulated. > Anti-cancer potentials of nano-encapsulated SC (NC) are evaluated in skin papilloma cells A375 through standard protocols. > Data of CD and Tm indicate concentration dependent interactions of NC bringing conformational changes in target DNA. > Particle size of NC and physico-chemical interactions with target DNA show NC as a more potent anti-cancer drug than SC. > NC has less cytotoxic effects, and can cross the blood brain barrier - important features for strategic drug design.

60 APPLIED LIFE SCIENCES↗

Reduced-order microstructure-sensitive protocols to rank-order the transition fatigue resistance of polycrystalline microstructures

We present that the transition fatigue regime between low cycle fatigue (LCF) and high cycle fatigue (HCF) is often addressed in the design and performance evaluation of load-bearing components used in many structural applications. Transition fatigue is characterized by elevated levels of local inelastic deformation in significant regions of the microstructure as compared to HCF. Typically, crystal plasticity finite element method (CPFEM) simulations are performed to model this phenomenon and to rank-order microstructures by their resistance to crack formation and early growth in the regime of transition fatigue. Unfortunately, these approaches require significant computational resources, inhibiting their use to explore novel materials for transition fatigue resistance. Reduced-order, microstructure-sensitive models are needed to accelerate the search for next-generation, fatigue-resistant materials. In a recent study, Paulson et al. (2018) extended the materials knowledge system (MKS) framework for rank-ordering the HCF resistance of polycrystalline microstructures. The efficacy of this approach lies in the reduced-dimensional representation of microstructures through 2-point spatial correlations and principal component analysis (PCA), in addition to the characterization of the HCF response with a small set of performance measures. In this work, these same protocols are critically evaluated for their applicability to rank-order the transition fatigue resistance of the same class of polycrystalline microstructures subjected to increased strain amplitudes. Success in this endeavor requires the formation of homogenization linkages that account for the significantly higher levels of local inelastic deformation and stress redistribution in transition fatigue as compared to HCF. Finally, a set of 12 α-titanium microstructures generated using the open access DREAM.3D software (Groeber and Jackson, 2014) are employed for this evaluation.

2-point correlations↗

A harmonized protocol to assess the single-cell performance of proton exchange membrane water electrolyzers

The harmonization of testing protocols for proton exchange membrane (PEM) electrolyzers is essential for ensuring accurate and reliable performance assessments and accelerating the development of hydrogen production technologies. This protocol provides a structured approach to PEM electrolyzer setup and testing, incorporating key considerations for test station design and single-cell characterization techniques. Polarization curves and electrochemical impedance spectroscopy (EIS) are detailed, along with best practices from academic and industry research groups to enhance data accuracy and comparability. By addressing material variability and harmonizing testing methodologies, this framework enables more precise evaluations of membrane electrode assemblies and electrolyzer components. Harmonized protocols not only streamline development efforts but also foster collaboration across institutions, ultimately supporting the commercialization of hydrogen solutions through improved stack efficiency and durability.

08 HYDROGEN↗

A parameterization method and application in breast tomosynthesis dosimetry

Purpose: To present a parameterization method based on singular value decomposition (SVD), and to provide analytical parameterization of the mean glandular dose (MGD) conversion factors from eight references for evaluating breast tomosynthesis dose in the Mammography Quality Standards Act (MQSA) protocol and in the UK, European, and IAEA dosimetry protocols.Methods: MGD conversion factor is usually listed in lookup tables for the factors such as beam quality, breast thickness, breast glandularity, and projection angle. The authors analyzed multiple sets of MGD conversion factors from the Hologic Selenia Dimensions quality control manual and seven previous papers. Each data set was parameterized using a one- to three-dimensional polynomial function of 2–16 terms. Variable substitution was used to improve accuracy. A least-squares fit was conducted using the SVD.Results: The differences between the originally tabulated MGD conversion factors and the results computed using the parameterization algorithms were (a) 0.08%–0.18% on average and 1.31% maximum for the Selenia Dimensions quality control manual, (b) 0.09%–0.66% on average and 2.97% maximum for the published data by Dance et al. [Phys. Med. Biol. 35, 1211–1219 (1990); ibid. 45, 3225–3240 (2000); ibid. 54, 4361–4372 (2009); ibid. 56, 453–471 (2011)], (c) 0.74%–0.99% on average and 3.94% maximum for the published data by Sechopoulos et al. [Med. Phys. 34, 221–232 (2007); J. Appl. Clin. Med. Phys. 9, 161–171 (2008)], and (d) 0.66%–1.33% on average and 2.72% maximum for the published data by Feng and Sechopoulos [Radiology 263, 35–42 (2012)], excluding one sample in (d) that does not follow the trends in the published data table.Conclusions: A flexible parameterization method is presented in this paper, and was applied to breast tomosynthesis dosimetry. The resultant data offer easy and accurate computations of MGD conversion factors for evaluating mean glandular breast dose in the MQSA protocol and in the UK, European, and IAEA dosimetry protocols. Microsoft Excel™ spreadsheets are provided for the convenience of readers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Three-dimensional magnetohydrodynamic modeling of auto-magnetizing liner implosions on the Z accelerator

Auto-magnetizing (AutoMag) liners are cylindrical tubes that employ helical current flow to produce strong internal axial magnetic fields prior to radial implosion on ~100 ns timescales. AutoMag liners have demonstrated strong uncompressed axial magnetic field production (>100 T) and remarkable implosion uniformity during experiments on the 20 MA Z accelerator. However, both axial field production and implosion morphology require further optimization to support the use of AutoMag targets in magnetized liner inertial fusion (MagLIF) experiments. Data from experiments studying the initiation and evolution of dielectric flashover in AutoMag targets on the Mykonos accelerator have enabled the advancement of magnetohydrodynamic (MHD) modeling protocols used to simulate AutoMag liner implosions. Implementing these protocols using ALEGRA has improved the comparison of simulations to radiographic data. Specifically, both the liner in-flight aspect ratio and the observed width of the encapsulant-filled helical gaps during implosion in ALEGRA simulations agree more closely with radiography data compared to previous GORGON simulations. Although simulations fail to precisely reproduce the measured internal axial magnetic field production, improved agreement with radiography data inspired the evaluation of potential design improvements with newly developed modeling protocols. Three-dimensional MHD simulation studies focused on improving AutoMag target designs, specifically seeking to optimize the axial magnetic field production and enhance the cylindrical implosion uniformity for MagLIF. Importantly, by eliminating the driver current prepulse and reducing the initial inter-helix gap widths in AutoMag liners, simulations indicate that the optimal 30–50 T range of precompressed axial magnetic field for MagLIF on Z can be accomplished concurrently with improved cylindrical implosion uniformity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characteristics of an Introduced Walleye Population with Implications for Suppression

Abstract The management of introduced fishes, including Walleye Sander vitreus, whether for control or enhancement, requires understanding of population dynamics at the invasion front. Walleye recently established in the Pend Oreille basin, Idaho, threaten the existing salmonid-based fish community and associated recreational fishery. Therefore, the objectives of this study were to describe population growth and associated life history characteristics. Walleye were sampled in October of 2011, 2014, and 2017 using a standardized gill netting survey protocol to describe trends in relative abundance and evaluate population dynamics. Relative abundance increased exponentially from 1.4 to 4.3 fish/net over the 6-year monitoring period. This population was characterized by fast somatic growth, robust body condition, and early age at maturity at or near the biological maxima for Walleye. Among the survey years, mean length at age 2 varied for female (359–441 mm) and male (358–426 mm) Walleye and relative weight varied from 91 to 98. The sampled Walleye matured at 1 to 4 years of age, and recruitment became more consistent as abundance increased. These density-dependent metrics suggest that the Walleye population is still at low density relative to carrying capacity. The information that was gained from this study was used to better understand potential risks and guide management decisions related to experimental population suppression that is now underway. Suppression under these conditions must overcome the recruitment capabilities of the population. We conclude that natural mortality is likely regulated by density-dependent processes. Therefore, at current (low) density, fishing mortality may be entirely additive and compensation is unlikely to further complicate management.

Ryan, Robert G.↗

The effect of tumor size and location on efficacy and safety of US- and CT- guided percutaneous microwave ablation in renal cell carcinomas

Purpose: To evaluate the effect of size and central location of the tumor on safety and efficacy of percutaneous CEUS- and CT-guided MWA in biopsy-proven renal cell carcinomas (RCCs). Materials and methods: In this IRB-approved retrospective study, 69 biopsy-proven renal tumors in 56 patients, who underwent MWA in our institution from January 2013 to March 2017, were evaluated. Data collection included demographics, tumor characteristics, procedural protocols, and follow-up visits within 6 months post procedure. Primary outcomes were assessed by technical success (TS), local tumor progression (LTP), and complications. The Kaplan–Meier analysis was used for survival rate. Results: Overall technical success was achieved for all 69 lesions (92.8% primary TS, 100% overall). Median nephrometry score was 8 (4–11) and median tumor size was 2.5 cm (0.8–7). Five lesions which required second ablation had significantly higher median tumor size 4 cm (P = 0.039) with the same nephrometry score. Renal function remained stable with no significant change in eGFR before or after ablation. The LTP rate was 5.8%. The most recurrent tumors were clear cell (50%) followed by papillary tumors (25%). The complication rate was 5.8% with minor complications (hematoma and pain) and no major issues. There was no significant association between nephrometry score and technical success, recurrence, or complication rates. Overall and tumor-specific survival rates were 96.7% and 100% at 11.9 months. Conclusions: Image-guided MWA appears to be a safe and effective treatment regardless of nephrometry score and tumor location with high technical success, low recurrence, and complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Involved-Field Radiation Therapy Protocol Deviations in Pediatric Versus Adolescent and Young Adults With Hodgkin Lymphoma: A Report From the Children's Oncology Group AHOD0031

The presented protocol for pediatric intermediate-risk Hodgkin lymphoma evaluated the use of a dose-intensive chemotherapy regimen (ABVE-PC [doxorubicin, bleomycin, vincristine, etoposide, cyclophosphamide, prednisone]) with response-based therapy augmentation (addition of DECA [dexamethasone, etoposide, cisplatin, cytarabine]) or therapy reduction (elimination of radiation).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In situ X-ray spatial profiling reveals uneven compression of electrode assemblies and steep lateral gradients in lithium-ion coin cells

Coin cells are used extensively as test devices in battery research for evaluation of new materials and optimization of cycling protocols. Here, in situ X-ray diffraction profilometry is used to characterize spatial distribution of the active materials, lithiation, and phase distribution in electrodes of NCM523/graphite coin cells. The X-ray data indicate uneven areal compression of the electrode assembly in such cells, which we trace to a specific design feature that leads to elastic deformation of a metal spacer. Steep lithiation gradients observed in the electrodes imply radially-dependent resistivity, for which uneven compression of the separator is a likely cause. Electrochemical model calculations suggest that variable porosity of the polymer separator would account for the salient features of spatial profiles observed in these coin cells.

25 ENERGY STORAGE↗

GenomeTrakr proficiency testing for foodborne pathogen surveillance: an exercise from 2015

Pathogen monitoring is becoming more precise as sequencing technologies become more affordable and accessible worldwide. This transition is especially apparent in the field of food safety, which has demonstrated how whole-genome sequencing (WGS) can be used on a global scale to protect public health. GenomeTrakr coordinates the WGS performed by public-health agencies and other partners by providing a public database with real-time cluster analysis for foodborne pathogen surveillance. Because WGS is being used to support enforcement decisions, it is essential to have confidence in the quality of the data being used and the downstream data analyses that guide these decisions. Routine proficiency tests, such as the one described here, have an important role in ensuring the validity of both data and procedures. In 2015, the GenomeTrakr proficiency test distributed eight isolates of common foodborne pathogens to participating laboratories, who were required to follow a specific protocol for performing WGS. Resulting sequence data were evaluated for several metrics, including proper labelling, sequence quality and new single nucleotide polymorphisms (SNPs). Illumina MiSeq sequence data collected for the same set of strains across 21 different laboratories exhibited high reproducibility, while revealing a narrow range of technical and biological variance. The numbers of SNPs reported for sequencing runs of the same isolates across multiple laboratories support the robustness of our cluster analysis pipeline in that each individual isolate cultured and resequenced multiple times in multiple places are all easily identifiable as originating from the same source.

59 BASIC BIOLOGICAL SCIENCES↗

UCX: An Open Source Framework for HPC Network APIs and Beyond, In: 2015 IEEE 23rd Annual Symposium on High-Performance Interconnects

This paper presents Unified Communication X (UCX), a set of network APIs and their implementations for high throughput computing. UCX comes from the combined effort of national laboratories, industry, and academia to design and implement a high-performing and highly-scalable network stack for next generation applications and systems. UCX design provides the ability to tailor its APIs and network functionality to suit a wide variety of application domains and hardware. We envision these APIs to satisfy the networking needs of many programming models such as Message Passing Interface (MPI), OpenSHMEM, Partitioned Global Address Space (PGAS) languages, task-based paradigms and I/O bound applications. To evaluate the design we implement the APIs and protocols, and measure the performance of overhead-critical network primitives fundamental for implementing many parallel programming models and system libraries. Our results show that the latency, bandwidth, and message rate achieved by the portable UCX prototype is very close to that of the underlying driver. With UCX, we achieved a message exchange latency of 0.89 us, a bandwidth of 6138.5 MB/s, and a message rate of 14 million messages per second. As far as we know, this is the highest bandwidth and message rate achieved by any network stack (publicly known) on this hardware.

Computer Science↗

The Lifetime Estimate for ACSR Single-Stage Splice Connector Operating at Higher Temperatures

This paper is the continuation of Part I effort to develop a protocol of integrating analytical and experimental approaches to evaluate the integrity of a full tension single-stage splice connector (SSC) assembly during service at high operating temperature.1The Part II efforts are mainly focused on the thermal mechanical testing, thermal-cycling simulation and its impact on the effective lifetime of the SSC system. The investigation indicates that thermal cycling temperature and frequency, conductor cable tension loading, and the compressive residual stress field within a SSC system have significant impact on the SSC integrity and the associated effective lifetime.

43 PARTICLE ACCELERATORS↗

SU-E-I-19: Optimization of Low Contrast Detectability Across Two CT Manufacturers

Purpose: Our goal was to evaluate low contrast detectability (LCD) for abdominal CT protocols across two CT scanner manufacturers, while producing a similar noise texture and CTDIvol for acquired images. Methods: A CIRS tissue equivalent LCD phantom containing three columns of 7 spherical targets, ranging from 10 mm to 2.4 mm, that are 5, 10, and 20 HU below the background matrix (HUBB) was scanned using two a GE HD750 64 slice scanner and a Siemens Somatom Definition AS 64 slice scanner. Protocols were designed to deliver a CTDIvol of 12.26 mGy and images were reconstructed with FBP, ASIR and Sapphire. Comparisons were made with those algorithms that had matching noise power spectrum peaks (NPS). NPS information was extracted from a previously published article that matched NPS peak frequencies across manufacturers by calculating the NPS from uniform phantom images reconstructed with several IR algorithms. Results: The minimum detectable lesion size in the 20 HUBB and 10 HUBB column was 6.3 mm, and 10 mm in the 5 HUBB column for the GE HD 750 scanner. The minimum detectable lesion size in the 20 HUBB column was 4.8 mm, in the 10 HUBB column, 9.5 mm, and the 5 HUBB column, 10 mm for the Siemens Somatom Definition AS. Conclusion: Reducing radiation dose while improving or maintaining LCD is possible with application of IR. However, there are several different IR algorithms, with each generating a different resolution and noise texture. In multi-manufacturer settings, matching only the CTDIvol between manufacturers may Result in a loss of clinically relevant information.

60 APPLIED LIFE SCIENCES↗