Search NASA⌕ Search

SEARCH · Search NASA

Results for “factory methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system

Purpose: In highly-conformal radiotherapy, due to the complexity of both beam configurations and dose distributions, traditional in vivo dosimetry is unpractical or even impossible. The ideal dosimeter would be implanted inside the planning treatment volume so that it can directly measure the total delivered dose during each fraction with no additional uncertainty due to calculation models. The aim of this work is to verify if implantable metal oxide semiconductors field effect transistors (MOSFETs) can achieve a sufficient degree of dosimetric accuracy when used inside extracranial targets undergoing radiotherapy treatments using the Cyberknife system. Methods: Based on the preliminary findings of this study, new prototypes for high dose fractionations were developed to reduce the time dependence for long treatment delivery times. These dosimeters were recently cleared and are marketed as DVS-HFT. Multiple measurements were performed using both Virtual Water and water phantoms to characterize implantable MOSFETs under the Cyberknife beams, and included the reference-dosimetry consistency, the dependence of the response on the collimator size, on the daily delivered dose, and the time irradiation modality. Finally a Cyberknife prostate treatment simulation using a body phantom was conducted, and both MOSFET and ionization readings were compared to Monte Carlo calculations. The feasibility analysis was conducted based on the ratios of the absorbed dose divided by the dose reading, named as ''further calibration factor'' (FCF). Results: The average FCFs resulted to be 0.98 for the collimator dependence test, and about 1.00 for the reference-dosimetry test, the dose-dependence test, and the time-dependence test. The average FCF of the prostate treatment simulation test was 0.99. Conclusions: The obtained results are well within DVS specifications, that is, the factory calibration is still valid for such kind of treatments using the Cyberknife system, with no need of further calibration factors to be applied. The final accuracy of implantable MOSFETs when used for such kind of treatments was estimated to be within {+-}4%. Additional investigations using dose/fraction higher than 12 Gy, different beam configurations, and tracking systems could extend the present findings to other kind of treatments. MOSFET technology was proven to have high versatility in fast adaptation of existing detectors to new applications. It is plausible to expect a general feasibility of implantable MOSFET technology for in vivo dosimetry of the extracranial-targets treatments using the Cyberknife, provided each particular application will be validated by suitable both physical and clinical studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

A gas circulation and purification system for gas-cell-based low-energy RI-beam production

A gas circulation and purification system was developed at the RIKEN Radioactive Isotope Beam Factory that can be used for gas-cell-based low-energy RI-beam production. A high-flow-rate gas cell filled with one atmosphere of buffer gas (argon or helium) is used for the deceleration and thermalization of high-energy RI-beams. The exhausted buffer gas is efficiently collected using a compact dry pump and returned to the gas cell with a recovery efficiency of >97%. The buffer gas is efficiently purified using two gas purifiers as well as collision cleaning, which eliminates impurities in the gas. An impurity level of one part per billion is achieved with this method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Electron Cyclotron Heating system status and upgrades on DIII-D

The Electron Cyclotron Heating (ECH) system on the DIII-D tokamak consists of six 110 GHz gyrotrons with corrugated coaxial 31.75 mm waveguide transmission lines and steerable launching mirrors. The system has been gradually updated, leading to increased experimental flexibility and a high system reliability of 91% in the past year. Operationally, the gyrotrons can generate up to a total of 4.8 MW of rf power for pulses up to 5 seconds in length. The maximum ECH energy injected into the DIII-D has been 16.6 MJ. The HE11 mode content is over 85% for all the lines, and the transmission coefficient is better than -1.1 dB for all the transmission lines, close to the theoretical value. A new depressed collector gyrotron was recently installed and was injecting up to 640 kW of power into the plasma during 2014-2015 tokamak operations. Three dual waveguide launchers, which can steer the RF beams ±20 degrees poloidally and toroidally, were used for real-time neoclassical tearing mode control and suppression. The launchers now have increased poloidal scanning speed and beam positioning accuracy of ~±2 mm at the plasma center. A new method of in-situ calibration of the mirror angle was used in conjunction with the upgrading of the encoders and motors for the launchers. Two more gyrotrons are expected to be installed and operational in 2015-2016. The first is a repaired 110 GHz, 1 MW gyrotron that had a gun failure after more than 11 years of operation at DIII-D. The second is a newly designed depressed collector tube in the 1.5 MW class, operating at 117.5 GHz, manufactured by Communications and Power Industries (CPI). It operates in the TE20,9 mode and has achieved 1.8 MW for short pulses during factory testing. Furthermore, this gyrotron is undergoing rework to address a high voltage standoff problem.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Agile manufacturing: The factory of the future

The factory of the future will require an operating methodology which effectively utilizes all of the elements of product design, manufacturing and delivery. The process must respond rapidly to changes in product demand, product mix, design changes or changes in the raw materials. To achieve agility in a manufacturing operation, the design and development of the manufacturing processes must focus on customer satisfaction. Achieving greatest results requires that the manufacturing process be considered from product concept through sales. This provides the best opportunity to build a quality product for the customer at a reasonable rate. The primary elements of a manufacturing system include people, equipment, materials, methods and the environment. The most significant and most agile element in any process is the human resource. Only with a highly trained, knowledgeable work force can the proper methods be applied to efficiently process materials with machinery which is predictable, reliable and flexible. This paper discusses the affect of each element on the development of agile manufacturing systems.

Loibl, Joseph M.↗

Mars Surveyor Program '01 Mars Environmental Compatibility Assessment wet chemistry lab: a sensor array for chemical analysis of the Martian soil

The Mars Environmental Compatibility Assessment (MECA) instrument was designed, built, and flight qualified for the now canceled MSP (Mars Surveyor Program) '01 Lander. The MECA package consisted of a microscope, electrometer, material patch plates, and a wet chemistry laboratory (WCL). The primary goal of MECA was to analyze the Martian soil (regolith) for possible hazards to future astronauts and to provide a better understanding of Martian regolith geochemistry. The purpose of the WCL was to analyze for a range of soluble ionic chemical species and electrochemical parameters. The heart of the WCL was a sensor array of electrochemically based ion-selective electrodes (ISE). After 20 months storage at -23 degrees C and subsequent extended freeze/thawing cycles, WCL sensors were evaluated to determine both their physical durability and analytical responses. A fractional factorial calibration of the sensors was used to obtain slope, intercept, and all necessary selectivity coefficients simultaneously for selected ISEs. This calibration was used to model five cation and three anion sensors. These data were subsequently used to determine concentrations of several ions in two soil leachate simulants (based on terrestrial seawater and hypothesized Mars brine) and four actual soil samples. The WCL results were compared to simulant and soil samples using ion chromatography and inductively coupled plasma optical emission spectroscopy. The results showed that flight qualification and prolonged low-temperature storage conditions had minimal effects on the sensors. In addition, the analytical optimization method provided quantitative and qualitative data that could be used to accurately identify the chemical composition of the simulants and soils. The WCL has the ability to provide data that can be used to "read" the chemical, geological, and climatic history of Mars, as well as the potential habitability of its regolith.

Non-NASA Center↗

Intermediate Palomar Transient Factory: Realtime Image Subtraction Pipeline

A fast-turnaround pipeline for realtime data reduction plays an essential role in discovering and permitting followup observations to young supernovae and fast-evolving transients in modern time-domain surveys. In this paper, we present the realtime image subtraction pipeline in the intermediate Palomar Transient Factory. By using highperformance computing, efficient databases, and machine-learning algorithms, this pipeline manages to reliably deliver transient candidates within 10 minutes of images being taken. Our experience in using high-performance computing resources to process big data in astronomy serves as a trailblazer to dealing with data from large-scale time-domain facilities in the near future.

79 ASTRONOMY AND ASTROPHYSICS↗

A Comprehensive Open-Source R Software For Statistical Metrology Calculations: From Uncertainty Evaluation To Risk Analysis

Whether calibrating equipment or inspecting products on the factory floor, metrology requires many complicated statistical calculations to achieve a full understanding and evaluation of measurement uncertainty and quality. In order to assist its workforce in performing these calculations in a consistent and rigorous way, the Primary Standards Lab at Sandia National Laboratories (SNL) has developed a free and open-source software package for computing various metrology calculations from uncertainty propagation to risk analysis. In addition to propagating uncertainty through a measurement model using the well-known Guide to Expression of Uncertainty in Measurement or Monte Carlo approaches, evaluating the individual Type A and Type B uncertainty components that go into the measurement model often requires other statistical methods such as analysis of variance or determining uncertainty in a fitted curve. Once the uncertainty in a measurement has been calculated, it is usually evaluated from a risk perspective to ensure the measurement is suitable for making a particular conformance decision. Finally, SNL’s software can perform all these calculations in a single application via an easy-to-use graphical interface, where the different functions are integrated so the results of one calculation can be used as inputs to another calculation.

97 MATHEMATICS AND COMPUTING↗

CRISPR-mediated multigene integration enables Shikimate pathway refactoring for enhanced 2-phenylethanol biosynthesis in Kluyveromyces marxianus

Background: 2-phenylethanol (2-PE) is a rose-scented flavor and fragrance compound that is used in food, beverages, and personal care products. Compatibility with gasoline also makes it a potential biofuel or fuel additive. A biochemical process converting glucose or other fermentable sugars to 2-PE can potentially provide a more sustainable and economical production route than current methods that use chemical synthesis and/or isolation from plant material. Results: We work toward this goal by engineering the Shikimate and Ehrlich pathways in the stress-tolerant yeast Kluyveromyces marxianus. First, we develop a multigene integration tool that uses CRISPR-Cas9 induced breaks on the genome as a selection for the one-step integration of an insert that encodes one, two, or three gene expression cassettes. Integration of a 5-kbp insert containing three overexpression cassettes successfully occurs with an efficiency of 51 ± 9% at the ABZ1 locus and was used to create a library of K. marxianus CBS 6556 strains with refactored Shikimate pathway genes. The 3 3 -factorial library includes all combinations of KmARO4, KmARO7, and KmPHA2, each driven by three different promoters that span a wide expression range. Analysis of the refactored pathway library reveals that high expression of the tyrosine-deregulated KmARO4 K221L and native KmPHA2, with the medium expression of feedback insensitive KmARO7 G141S , results in the highest increase in 2-PE biosynthesis, producing 684 ± 73 mg/L. Ehrlich pathway engineering by overexpression of KmARO10 and disruption of KmEAT1 further increases 2-PE production to 766 ± 6 mg/L. The best strain achieves 1943 ± 63 mg/L 2-PE after 120 h fed-batch operation in shake flask cultures. Conclusions: The CRISPR-mediated multigene integration system expands the genome-editing toolset for K. marxianus, a promising multi-stress tolerant host for the biosynthesis of 2-PE and other aromatic compounds derived from the Shikimate pathway.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Startup of the Kling Center for Proton Therapy

In November of 2011 Mevion Medical Systems (formerly Still River Systems) delivered the Mevion S250 proton therapy system accelerator to the Kling Center for Proton Therapy at the Siteman Cancer Center in Saint Louis. The Mevion system is unique, with an in-room gantry-mounted superconducting synchrocyclotron. This is the first true single-room proton therapy system and it has a greatly reduced size as well as cost. A month after its arrival, the installation was complete and the superconducting magnet was ramped up to full current ({approx}2000 amperes). In March of 2012, full energy beam (250 MeV) was extracted and radiation surveys were performed to verify the shielding. Once that was shown to be sufficient, Mevion began fine-tuning the system to provide a highly isocentric beam from the 50 ton system. In June of 2012 the field-shaping system (energy degraders, contoured scatterers and range modulators) were installed and measurements of the clinical beam properties commenced. Monte Carlo simulations (MCNPX) have been performed for the system and validated with beam measurements done at the factory. These simulations have been used for a preliminary commissioning of our treatment planning system. Additionally, predictions of the neutron background have been made and validated with factory measurements. Final commissioning of the treatment planning system and verification of the neutron background will be accomplished with measurements made later in 2012. Based on current progress, patient treatments are scheduled to begin in late 2012. Beam and radiation background data will be presented.

43 PARTICLE ACCELERATORS↗

Feasibility Study: Ductless Hydronic Distribution Systems with Fan Coil Delivery

Hydronic distribution systems have a long history, and are widely used in commercial buildings. As with mini-split heat pumps, hydronic systems using small terminal fan coils have the potential to provide high-quality comfort to homes that have small heating and cooling loads, but at a lower cost and with greater flexibility. These “ductless hydronic” distribution systems eliminate space requirements needed for ducting, eliminate duct thermal losses, and are easy to zone. Since heat pump chiller-heaters can be charged with refrigerant at the factory, hydronic systems also avoid refrigerant system faults such as incorrect charge and inadequate evacuation of lines that can lead to sub-standard performance. Other advantages include: reduction in the amount of energy required to deliver heating and cooling, reduced equipment cycling, and the potential for incorporating energy storage for peak load avoidance and demand response. Ductless hydronic systems are best suited for new homes, but with the relative ease of installing piping in attic spaces (for example under attic insulation), they are also suitable for existing homes that have old, leaky, and poorly insulated ducts. With a broader and more affordable product offering from manufacturers, installation guidelines, and contractor training, this method of distribution has significant potential to meet the space conditioning needs of high performance homes. The primary objectives of this study are to estimate potential energy savings relative to conventional ducted air distribution, and to identify equipment requirements, costs, and barriers. The analysis focuses on ductless hydronic delivery systems that use water-to-air terminal units in each zone. This system type is applicable in all climate regions and can provide sensible and latent cooling and/or heating using a single hot and chilled water source such as a heat pump, or a separate water heater and chiller. Results of TRNSYS modeling indicate that annual heating and cooling energy use (site and source) can be reduced by up to 22% when substituting pipes, pump, small distributed fan coils, and a water-to-air heat pump for the ducts, air handler, indoor coil, and conventional air-to-air heat pump unit of similar rating as the air-to-water unit. Of the 22% savings, on average 36% is attributable to the lower energy required by pumps and small fans vs. air handler blowers, and 64% to the reduced losses from pipes as compared to ducts. Using the modeled energy savings and estimated costs, hydronic distribution appears to be economically viable in three of the four climates evaluated. Other current field studies of air-to-water heat pumps coupled to radiant floor systems are demonstrating heat pump performance that exceeds seasonal performance calculated using a standard heat pump performance map (German, 2011a, German, 2011b). Hydronic distribution systems can meet sensible and latent cooling needs in all climates. Major barriers to widespread application include the lack of low-cost, small, ceiling-mounted fan coils, and the limited availability and higher cost of air-to-water heat pumps. The latter could be overcome by the production of an add-on refrigerant-to-water conversion kit that could be used to adapt any heat pump to serve as a water chiller-heater. Development of accurate performance maps and additional data on field performance are areas that should be targeted by future research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HARP and NA61 (SHINE) hadron production experiments

The hadroproduction experiments HARP and NA61 (SHINE) as well as their implications for neutrino physics are discussed. Recent HARP measurements have already been used for precise predictions of neutrino beams in K2K and MiniBooNE/SciBooNE experiments and are also being used to improve the atmospheric neutrino flux predictions and to help in the optimization of neutrino factory and super-beam designs. First preliminary data from NA61 are of significant importance for a precise prediction of a new neutrino beam at J-PARC to be used for the first stage of the T2K experiment. Both HARP and NA61 provide a large amount of input for validation and tuning of hadroproduction models in Monte-Carlo generators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implanted Cardiac Defibrillator Care in Radiation Oncology Patient Population

Purpose: To review the experience of a large cancer center with radiotherapy (RT) patients bearing implantable cardiac defibrillators (ICDs) to propose some preliminary care guidelines as we learn more about the devices and their interaction with the therapeutic radiation environment. Methods and Materials: We collected data on patients with implanted ICDs treated with RT during a 2.5-year period at any of the five Memorial Sloan-Kettering clinical campuses. Information regarding the model, location, and dose detected from the device, as well as the treatment fields, fraction size, and treatment energy was collected. During this time, a new management policy for these patients had been implemented requiring treatment with low-energy beams (6 MV) and close surveillance of the patients in partnership with their electrophysiologist, as they received RT. Results: During the study period, 33 patients were treated with an ICD in place. One patient experienced a default of the device to its initial factory setting that was detected by the patient hearing an auditory signal from the device. This patient had initially been treated with a 15-MV beam. After this episode, his treatment was replanned to be completed with 6-MV photons, and he experienced no further events. Conclusion: Patients with ICDs and other implanted computer-controlled devices will be encountered more frequently in the RT department, and proper management is important. We present a policy for the safe treatment of these patients in the radiation oncology environment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Leveraging Calibration Transfer Techniques for Remote Monitoring of Samarium and Europium in LiCl Using Laser-Induced Florescence Spectroscopy for Radioisotope Production Applications

Radioisotope production relies on complex chemical processes that must be performed in radiological hot cells or glove boxes because of the radioactive and otherwise hazardous materials being used. In these situations, optical sensors can provide real-time monitoring to users, which is unobtainable by more traditional methods. This study explores the use of calibration transfer methods to train a model on one instrument and date and then transfer it to another instrument of the same or different configuration on a different date. By performing laser-induced fluorescence measurements of Eu(III) and Sm(III) in 10 M LiCl over the course of 6 months using two disparate spectrometers and two different training sets, a strategy for calibrating and deploying models for online monitoring was established. Three transfer techniques were compared: direct standardization (DS), piecewise direct standardization (PDS), and external parameter orthogonalization (EPO). DS and PDS outperformed EPO for day-to-day transfers, and EPO was not effective for instrument-to-instrument transfers. Transferring the initial date’s full factorial model provided better prediction performance compared with retraining models the day of measurements using a D-optimal designed calibration set. For both day-to-day and instrument-to-instrument transfers, five Kennard–Stone selected samples were sufficient. Based on this choice, the initial-date, high-resolution spectrometer model was transferred to a lower-resolution, compact spectrometer 6 months later to monitor a simulated, real-time demonstration. Here, the combined predictions of the DS and PDS transferred models were able to accurately track the anticipated concentration profiles, maintaining root-mean-square error of prediction values below 10 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiparticle integral and differential correlation functions

This paper formalizes the use of integral and differential cumulants for measurements of multiparticle event-by-event transverse momentum fluctuations, rapidity fluctuations, as well as net-charge fluctuations. This enables the introduction of multiparticle balance functions, defined based on differential correlation functions (factorial cumulants), that suppress two- and three-prong resonance decays effects and enable measurements of underlying long-range correlations obeying quantum number conservation constraints. These multiparticle balance functions satisfy simple sum rules determined by quantum number conservation. It is additionally shown that these multiparticle balance functions arise as an intrinsic component of high-order net-charge cumulants. This implies that the magnitude of these cumulants, measured in a specific experimental acceptance, is strictly constrained by charge conservation and primarily determined by the rapidity and momentum width of these balance functions. The paper also presents techniques to reduce the computation time of differential correlation functions up to order n = 10 based on the methods of moments. Published by the American Physical Society 2024

Physics↗

Repository of HydroSMADE: Hydropower Site-level Monthly Availability Data Ensemble for 1950-2100 at Existing and Potential Global Sites

This repository presents HydroSMADE—Hydropower Site-level Monthly Availability Data Ensemble, a new open dataset that provides monthly hydropower availability for 1,593 existing and 124,333 potential sites worldwide over the period 1950–2100. The dataset is generated by using a global hydrologic model (Xanthos) with explicit representation of hydropower operation. Specifically, HydroSMADE distinguishes between storage and diversion sites, applies optimized operating rules, and incorporates site-specific characteristics such as generation capacity, maximum turbine flow, and reservoir storage. Driven by bias-corrected meteorological inputs, the data is provided for 30 alternative future scenarios. The scenarios consist of the full factorial combination of three standard CMIP6 atmospheric forcing pathways (SSP1-2.6, SSP3-7.0, and SSP5-8.5) and ten CMIP6 General Circulation Models (GCMs): GFDL-ESM4, IPSL-CM6A-LR, MPI-ESM1-2-HR, MRI-ESM2-0, EC-Earth3, CanESM5, MIROC6, CNRM-ESM2-1, UKESM1-0-LL, and CNRM-CM6-1. The repository contains a total of 122 files: a text file (readme.txt) containing a brief description of the included data, a CSV file containing site attributes, and the remaining 120 files (in CSV) containing site-level monthly hydropower availability. Example Jupyter Notebooks to explore the HydroSMADE dataset are available on GitHub at https://github.com/kamal0013/HydroSMADE More details on the methods and technical validation of HydroSMADE are available in the following paper by the same authors: Chowdhury, A. K., Abeshu, G. W., Zhao, M., Wild, T. B., Hassan, N., Ying, Z., Kim, G. J., Matthew, B., Jonathan, L., & Li, H.-Y. (Submitted). Hydropower Site-level Monthly Availability Data Ensemble for 1950-2100 at Existing and Potential Global Sites.

Existing and Potential Sites↗

Effects of Self-Instructional Methods and Above Real Time Training (ARTT) for Maneuvering Tasks on a Flight Simulator

Personal computer based flight simulators are expanding opportunities for providing low-cost pilot training. One advantage of these devices is the opportunity to incorporate instructional features into training scenarios that might not be cost effective with earlier systems. Research was conducted to evaluate the utility of different instructional features using a coordinated level turn as an aircraft maneuvering task. In study I, a comparison was made between automated computer grades of performance with certified flight instructors grades. Every one of the six student volunteers conducted a flight with level turns at two different bank angles. The automated computer grades were based on prescribed tolerances on bank angle, airspeed and altitude. Two certified flight instructors independently examined the video tapes of heads up and instrument displays of the flights and graded them. The comparison of automated grades with the instructors grades ms based on correlations between them. In study II, a 2x2 between subjects factorial design was used to devise and conduct an experiment. Comparison was made between real time training and above real time training and between feedback and no feedback in training. The performance measure to monitor progress in training was based on deviations in bank angle and altitude. The performance measure was developed after completion of the experiment including the training and test flights. It was not envisaged before the experiment. The experiment did not include self-instructions as it was originally planned, although feedback by experimenter to the trainee was included in the study.

Norlin, Ken↗

Effects of Self-Instructional Methods and Above Real Time Training (ARTT) for Maneuvering Tasks on a Flight Simulator

Personal computer based flight simulators are expanding opportunities for providing low-cost pilot training. One advantage of these devices is the opportunity to incorporate instructional features into training scenarios that might not be cost effective with earlier systems. Research was conducted to evaluate the utility of different instructional features using a coordinated level turn as an aircraft maneuvering task. In study I, a comparison was made between automated computer grades of performance with certified flight instructors grades. Every one of the six student volunteers conducted a flight with level turns at two different bank angles. The automated computer grades were based on prescribed tolerances on bank angle, airspeed and altitude. Two certified flight instructors independently examined the video tapes of heads up and instrument displays of the flights and graded them. The comparison of automated grades with the instructors grades was based on correlations between them. In study II, a 2x2 between subjects factorial design was used to devise and conduct an experiment. Comparison was made between real time training and above real time training and between feedback and no feedback in training. The performance measure to monitor progress in training was based on deviations in bank angle and altitude. The performance measure was developed after completion of the experiment including the training and test flights. It was not envisaged before the experiment. The experiment did not include self- instructions as it was originally planned, although feedback by experimenter to the trainee was included in the study.

Ali, Syed Firasat↗

Cross-Sector Impact Analysis of Industrial Efficiency Measures

The industrial or manufacturing sector is a foundational component to all economic activity. In addition to being a large direct consumer of energy, the manufacturing sector also produces materials, products, and technologies that influence the energy use of other economic sectors. For example, the manufacturing of a lighter-weight vehicle component affects the energy required to ship that component as well as the fuel efficiency of the assembled vehicle. Many energy efficiency opportunities exist to improve manufacturing energy consumption, however comparisons of manufacturing sector energy efficiency investment opportunities tend to exclude any impacts that occur once the product leaves the factory. Expanding the scope of analysis to include energy impacts across different stages of product life-cycle can highlight less obvious opportunities and inform actions that create the greatest economy-wide benefits. We present a methodology and associated analysis tool (LIGHTEnUP Lifecycle Industry GHgas, Technology and Energy through the Use Phase) that aims to capture both the manufacturing sector energy consumption and product life-cycle energy consumption implications of manufacturing innovation measures. The tool architecture incorporates U.S. national energy use data associated with manufacturing, building operations, and transportation. Inputs for technology assessment, both direct energy saving to the manufacturing sector, and indirect energy impacts to additional sectors are estimated through extensive literature review and engineering methods. The result is a transparent and uniform system of comparing manufacturing and use-phase impacts of technologies.

ACEEE↗