Search NASA⌕ Search

SEARCH · Search NASA

Results for “fault current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Model of Inverter-Based Resources

Blackbox modelling for SC analysis is a possible solution. Accuracy can be acceptable even without having vendor control diagrams. Is an NDA required to share a vendor Blackbox model for SC analysis? Differences in VRT detection and injection logics. Angle rotation is not addressed in control logics of most vendors. Current limitation logic during unbalanced faults is not clear. Model IBR as a current source with shunt to improve convergence

IBRs, Model of IBRs, Short Circuit Analysis, Class↗

Flight Simulator Demonstration and Certification Implications of Powertrain Failure Mitigation in a Partial Turboelectric Aircraft

The Single-aisle Turboelectric AiRCraft with Aft Boundary Layer propulsor (STARC ABL) is a concept aircraft with a partial turboelectric powertrain. The complexity and integrated nature of the partial turboelectric powertrain architecture presents failure modes and hazards not found in conventional aircraft propulsion designs. Previously, various electrical and mechanical faults and associated recovery modes were demonstrated in a dynamic model of the powertrain. It was shown that certain faults were catastrophic without recovery logic, due specifically to the interaction of the subsystems. However, in each case, the logic, known as a reversionary control mode, enabled continued operation with assumed sufficient thrust to maintain safe flight. The current work evaluates the powertrain faults and recovery strategies using a full aircraft model in a piloted flight simulator, and places it in the context of current regulatory practice. Faults initiated in flight were successfully mitigated, with the accommodated aircraft subsequently evaluated against certification requirements for three-engine aircraft, which were shown to be appropriate for the STARC-ABL configuration.

STARC-ABL↗

Flight Simulator Demonstration and Certification Implications of Powertrain Failure Mitigation in a Partial Turboelectric Aircraft

The Single-aisle Turboelectric AiRCraft with Aft Boundary Layer propulsor (STARC ABL) is a concept aircraft with a partial turboelectric powertrain. The complexity and integrated nature of the partial turboelectric powertrain architecture presents failure modes and hazards not found in conventional aircraft propulsion designs. Previously, various electrical and mechanical faults and associated recovery modes were demonstrated in a dynamic model of the powertrain. It was shown that certain faults were catastrophic without recovery logic, due specifically to the interaction of the subsystems. However, in each case, the logic, known as a reversionary control mode, enabled continued operation with assumed sufficient thrust to maintain safe flight. The current work evaluates the powertrain faults and recovery strategies using a full aircraft model in a piloted flight simulator, and places it in the context of current regulatory practice. Faults initiated in flight were successfully mitigated, with the accommodated aircraft subsequently evaluated against certification requirements for three-engine aircraft, which were shown to be appropriate for the STARC-ABL configuration.

STARC-ABL↗

Flight Simulator Demonstration and Certification Implications of Powertrain Failure Mitigation in a Partial Turboelectric Aircraft

The Single-aisle Turboelectric AiRCraft with Aft Boundary Layer propulsor (STARC ABL) is a concept aircraft with a partial turboelectric powertrain. The complexity and integrated nature of the partial turboelectric powertrain architecture presents failure modes and hazards not found in conventional aircraft propulsion designs. Previously, various electrical and mechanical faults and associated recovery modes were demonstrated in a dynamic model of the powertrain. It was shown that certain faults were catastrophic without recovery logic, due specifically to the interaction of the subsystems. However, in each case, the logic, known as a reversionary control mode, enabled continued operation with assumed sufficient thrust to maintain safe flight. The current work evaluates the powertrain faults and recovery strategies using a full aircraft model in a piloted flight simulator, and places it in the context of current regulatory practice. Faults initiated in flight were successfully mitigated, with the accommodated aircraft subsequently evaluated against certification requirements for three-engine aircraft, which were shown to be appropriate for the STARC-ABL configuration.

certification↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

Transform fault earthquakes in the North Atlantic: Source mechanisms and depth of faulting

The centroid depths and source mechanisms of 12 large earthquakes on transform faults of the northern Mid-Atlantic Ridge were determined from an inversion of long-period body waveforms. The earthquakes occurred on the Gibbs, Oceanographer, Hayes, Kane, 15 deg 20 min, and Vema transforms. The depth extent of faulting during each earthquake was estimated from the centroid depth and the fault width. The source mechanisms for all events in this study display the strike slip motion expected for transform fault earthquakes; slip vector azimuths agree to 2 to 3 deg of the local strike of the zone of active faulting. The only anomalies in mechanism were for two earthquakes near the western end of the Vema transform which occurred on significantly nonvertical fault planes. Secondary faulting, occurring either precursory to or near the end of the main episode of strike-slip rupture, was observed for 5 of the 12 earthquakes. For three events the secondary faulting was characterized by reverse motion on fault planes striking oblique to the trend of the transform. In all three cases, the site of secondary reverse faulting is near a compression jog in the current trace of the active transform fault zone. No evidence was found to support the conclusions of Engeln, Wiens, and Stein that oceanic transform faults in general are either hotter than expected from current thermal models or weaker than normal oceanic lithosphere.

Bergman, Eric A.↗

Transform fault earthquakes in the North Atlantic - Source mechanisms and depth of faulting

The centroid depths and source mechanisms of 12 large earthquakes on transform faults of the northern Mid-Atlantic Ridge were determined from an inversion of long-period body waveforms. The earthquakes occurred on the Gibbs, Oceanographer, Hayes, Kane, 15 deg 20 min, and Vema transforms. The depth extent of faulting during each earthquake was estimated from the centroid depth and the fault width. The source mechanisms for all events in this study display the strike slip motion expected for transform fault earthquakes; slip vector azimuths agree to 2 to 3 deg of the local strike of the zone of active faulting. The only anomalies in mechanism were for two earthquakes near the western end of the Vema transform which occurred on significantly nonvertical fault planes. Secondary faulting, occurring either precursory to or near the end of the main episode of strike-slip rupture, was observed for 5 of the 12 earthquakes. For three events the secondary faulting was characterized by reverse motion on fault planes striking oblique to the trend of the transform. In all three cases, the site of secondary reverse faulting is near a compression jog in the current trace of the active transform fault zone. No evidence was found to support the conclusions of Engeln, Wiens, and Stein that oceanic transform faults in general are either hotter than expected from current thermal models or weaker than normal oceanic lithosphere.

Bergman, Eric A.↗

Fault-tolerant software

Limitations in the current capabilities for verifying programs by formal proof or by exhaustive testing have led to the investigation of fault-tolerance techniques for applications where the consequence of failure is particularly severe. Two current approaches, N-version programming and the recovery block, are described. A critical feature in the latter is the acceptance test, and a number of useful techniques for constructing these are presented. A system reliability model for the recovery block is introduced, and conclusions derived from this model that affect the design of fault-tolerant software are discussed.

Hecht, H.↗

NSTX Protection And Interlock Systems For Coil And Powers Supply Systems

NSTX at Princeton Plasma Physics Laboratory (PPPL) requires sophisticated plasma positioning control system for stable plasma operation. TF magnetic coils and PF magnetic coils provide electromagnetic fields to position and shape the plasma vertically and horizontally respectively. NSTX utilizes twenty six coil power supplies to establish and initiate electromagnetic fields through the coil system for plasma control. A power protection and interlock system is utilized to detect power system faults and protect the TF coils and PF coils against excessive electromechanical forces, overheating, and over current. Upon detecting any fault condition the power system is restricted, and it is either prevented from initializing or suppressed to de-energize coil power during pulsing. Power fault status is immediately reported to the computer system. This paper describes the design and operation of NSTX's protection and interlocking system and possible future expansion.

Power↗

Adaptive Threshold-Based Zonal Isolation of Faults in a Multiterminal DC Using Local Measurements

Fast and accurate methods of fault detection and isolation are a pre-emptive measure in multiterminal dc (MTdc) systems. Zonal isolation of faults is necessary to prevent any misopertation of the dc breakers that can lead to a shutdown of the network. Existing techniques require fast-communication or data synchronization methods have their own disadvantages. This article proposes a method for efficient fault zone isolation without the need of a communication link that prevents any misoperation of the dc breakers in a radial MTdc. This method provides individual local measurement-based control to the hybrid dc circuit breakers (dcCB). Faults created outside the zone of protection for a breaker create a change in the rate of change of current or voltage leading to misoperation. To avoid detection using a fixed threshold, an adaptive threshold based approach is suggested that updates the threshold based on the present operating status. Sensitivity analysis by varying the current limiting inductance and fault location is performed. In conclusion, a three terminal radial model of an MTdc is used for zonal isolation using power system computer aided design/electromagnetic transients including dc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

rMPI : increasing fault resiliency in a message-passing environment.

As High-End Computing machines continue to grow in size, issues such as fault tolerance and reliability limit application scalability. Current techniques to ensure progress across faults, like checkpoint-restart, are unsuitable at these scale due to excessive overheads predicted to more than double an applications time to solution. Redundant computation, long used in distributed and mission critical systems, has been suggested as an alternative to checkpoint-restart on its own. In this paper we describe the rMPI library which enables portable and transparent redundant computation for MPI applications. We detail the design of the library as well as two replica consistency protocols, outline the overheads of this library at scale on a number of real-world applications, and finally outline the significant increase in an applications time to solution at extreme scale as well as show the scenarios in which redundant computation makes sense.

99 GENERAL AND MISCELLANEOUS↗

The Curiosity Mars Rover's Fault Protection Engine

The Curiosity Rover, currently operating on Mars, contains flight software onboard to autonomously handle aspects of system fault protection. Over 1000 monitors and 39 responses are present in the flight software. Orchestrating these behaviors is the flight software's fault protection engine. In this paper, we discuss the engine's design, responsibilities, and present some lessons learned for future missions.

flight software↗

rMPI

As high-performance computing (HPC) machines continue to grow in size, issues such as fault tolerance and reliability limit application scalability. Current techniques to ensure progress across faults, like checkpoint-restart, are unsuitable on their own for exascale machines due to the excessive overheads predicted to more than double an applications time to solution. An alternative mechanism to increase application reliability than just checkpoint-restart alone is redundant computation. The rMPl library enables portable and transparent redundant computation) that, at extreme scale, has significantly lower verhead then just checkpoint-restart on its own.

Source record↗

Dynamic, resilient sensing system for automatic cyber-attack neutralization

An industrial asset may have monitoring nodes that generate current monitoring node values. An abnormality detection computer may determine that an abnormal monitoring node is currently being attacked or experiencing fault. A dynamic, resilient estimator constructs, using normal monitoring node values, a latent feature space (of lower dimensionality as compared to a temporal space) associated with latent features. The system also constructs, using normal monitoring node values, functions to project values into the latent feature space. Responsive to an indication that a node is currently being attacked or experiencing fault, the system may compute optimal values of the latent features to minimize a reconstruction error of the nodes not currently being attacked or experiencing a fault. The optimal values may then be projected back into the temporal space to provide estimated values and the current monitoring node values from the abnormal monitoring node are replaced with the estimated values.

97 MATHEMATICS AND COMPUTING↗

Analysis and Experiment of Management Sciences Inc.'s Arc Fault Protection Connectors

The photovoltaics industry is in dire need of a cheap, robust, reliable arc fault detector that is sensitive enough to detect arc faults before they can develop into a fire while robust enough to noise to limit unwanted tripping. Management Sciences has developed an arc fault detector that is housed in a standard PV connector, which will disconnect the PV array when it detects the surge current from an arc fault. Sandia National Labs, an industry leader in the detection, characterization, and mitigation of arc faults in PV arrays, will work with Management Sciences to characterize, demonstrate, and develop their arc fault detection/connector technology.

14 SOLAR ENERGY↗

A Robust Communication-Free Protection Scheme for Islanded Microgrids with Relay Logic and Hardware-in-the-Loop Validation

This paper presents the Imbalance Square Factor (ISF) detection algorithm, an effective, computationally lightweight method for detecting faults in inverter-based microgrids. ISF provides a high magnitude at the time of the fault, which allows for fast detection and coordination between primary and backup relays. The imbalance squared factor, calculated using local voltage and currents, is used for fault detection and coordination among three relays. ISF is validated in hardware-in-the-loop (HIL) implementation inside commercial-grade relay logic (SEL-751). The HIL validation shows that ISF can coordinate primary, secondary, and tertiary relays in the 13-bus system in islanded operation.

Ferrari Maglia, Max [ORNL]↗

Probabilistic Approach to Enable Extreme-Scale Simulations under Uncertainty and System Faults. Final Technical Report

The current project develops a novel approach that uses a probabilistic description to capture the current state of knowledge about the computational solution. To effectively spread the computational effort over multiple nodes, the global computational domain is split into many subdomains. Computational uncertainty in the solution translates into uncertain boundary conditions for the equation system to be solved on those subdomains, and many independent, concurrent subdomain simulations are used to account for this bound- ary condition uncertainty. By relying on the fact that solutions on neighboring subdomains must agree with each other, a more accurate estimate for the global solution can be achieved. Statistical approaches in this update process make it possible to account for the effect of system faults in the probabilistic description of the computational solution, and the associated uncertainty is reduced through successive iterations. By combining all of these elements, the probabilistic reformulation allows splitting the computational work over very many independent tasks for good scalability, while being robust to system faults.

97 MATHEMATICS AND COMPUTING↗

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗