Search NASA⌕ Search

SEARCH · Search NASA

Results for “filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Adjunctive Inferior Vena Cava Filter Placement for Acute Pulmonary Embolism

Inferior vena cava (IVC) filters are sometimes placed as an adjunct to full anticoagulation in patients with significant pulmonary embolism (PE). We aimed to determine the prevalence of adjunctive IVC filter placement in individuals diagnosed with PE, as well as the effect of adjunctive filter placement on mortality in patients with right heart strain associated with PE. This was a retrospective study of patients with acute PE treated with full anticoagulation admitted to a single academic medical center. Information abstracted from patient charts included presence or absence of right heart strain and of deep-vein thrombosis, and whether or not an IVC filter was placed. The endpoint was in-hospital mortality. Over 2.75 years, we found that 248 patients were diagnosed with acute PE, with an in-hospital mortality rate of 4.4%. The prevalence of adjunctive IVC filter placement was 13.3% (33 of 248), and the prevalence of documented right heart strain was 27.0% (67 of 248). In-hospital mortality was 10.2% in the non-filter-treated group (5 of 49), whereas there were no deaths in the filter-treated group (0 of 18); however, the difference was not statistically significant (P = 0.37). Both the presence of deep-vein thrombosis and of right heart strain increased the likelihood that an adjunctive IVC filter was placed (P < 0.0001 and P < 0.001, respectively). At our institution, patients were treated with IVC filters in addition to anticoagulation in 13.3% of cases of acute PE. Prospective studies or large clinical registries should be conducted to clarify whether this practice improves outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Demonstration of a Single-Crystal Reflector-Filter for Enhancing Slow Neutron Beams

The cold polycrystalline beryllium reflector-filter concept has been used to enhance the cold neutron emission of cryogenic hydrogen moderators, while suppressing the intermediate wavelength and fast neutron emission at the same time. While suppressing the fast neutron emission is often desired, the suppression of intermediate wavelength neutrons is often unwelcome. It has been hypothesized that replacing the polycrystalline reflector-filter concept with a single-crystal reflector-filter concept would overcome the suppression of intermediate wavelength neutrons and thereby extend the usability of the reflector-filter concept to shorter but still important wavelengths. In this paper we present the first experimental data on a single-crystal reflector-filter and compare experimental results with hypothesized performance. We find that a single-crystal reflector-filter retains the long-wavelength benefit of the polycrystalline reflector-filter, without suffering the same loss of important intermediate wavelength neutrons. Ultimately, this finding extends the applicability of the reflector-filter concept to intermediate wavelengths, and furthermore indicates that the reflector-filter benefits arise from its interaction with fast (background) neutrons, not with intermediate wavelength neutrons of potential interest in many types of neutron scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial filtering with photonic crystals

Photonic crystals are well known for their celebrated photonic band-gaps—the forbidden frequency ranges, for which the light waves cannot propagate through the structure. The frequency (or chromatic) band-gaps of photonic crystals can be utilized for frequency filtering. In analogy to the chromatic band-gaps and the frequency filtering, the angular band-gaps and the angular (spatial) filtering are also possible in photonic crystals. In this article, we review the recent advances of the spatial filtering using the photonic crystals in different propagation regimes and for different geometries. We review the most evident configuration of filtering in Bragg regime (with the back-reflection—i.e., in the configuration with band-gaps) as well as in Laue regime (with forward deflection—i.e., in the configuration without band-gaps). We explore the spatial filtering in crystals with different symmetries, including axisymmetric crystals; we discuss the role of chirping, i.e., the dependence of the longitudinal period along the structure. We also review the experimental techniques to fabricate the photonic crystals and numerical techniques to explore the spatial filtering. Finally, we discuss several implementations of such filters for intracavity spatial filtering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of plasma parameters with magnetic filter field and pressure to maximize H{sup −} ion density in a negative hydrogen ion source

Transverse magnetic filter field as well as operating pressure is considered to be an important control knob to enhance negative hydrogen ion production via plasma parameter optimization in volume-produced negative hydrogen ion sources. Stronger filter field to reduce electron temperature sufficiently in the extraction region is favorable, but generally known to be limited by electron density drop near the extraction region. In this study, unexpected electron density increase instead of density drop is observed in front of the extraction region when the applied transverse filter field increases monotonically toward the extraction aperture. Measurements of plasma parameters with a movable Langmuir probe indicate that the increased electron density may be caused by low energy electron accumulation in the filter region decreasing perpendicular diffusion coefficients across the increasing filter field. Negative hydrogen ion populations are estimated from the measured profiles of electron temperatures and densities and confirmed to be consistent with laser photo-detachment measurements of the H{sup −} populations for various filter field strengths and pressures. Enhanced H{sup −} population near the extraction region due to the increased low energy electrons in the filter region may be utilized to increase negative hydrogen beam currents by moving the extraction position accordingly. This new finding can be used to design efficient H{sup −} sources with an optimal filtering system by maximizing high energy electron filtering while keeping low energy electrons available in the extraction region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiological HEPA Filter 10-year Lifetime Evaluation in Research Facilities

High-efficiency particulate air (HEPA) filters are widely employed by nuclear facilities to remove radiological particulate matter from their effluent exhaust streams. The purpose of this study is to evaluate the relationships between the 10-year HEPA filter lifetime deployment and its other performance indicators. This 10-year-long endeavor to collect and analyze data regarding the service life of HEPA filters at the Pacific Northwest National Laboratory began in 2010. A set of HEPA filters were selected and have been surveyed and analyzed at least annually to verify compliance with permit conditions. The study suggests the frequency of filter replacement should be based on the actual operational requirements, such as fume hood face velocity and/or efficiency test results, instead of on the prescribed filter “age limit” of 10 years from the date of manufacture (e.g., birth date) when operating under dry conditions. The study has now been completed, and over the past decade all the HEPA filters have been replaced, due to either technical issues as listed in this report or the previously recommended filter “age limit” of 10 years as prescribed by the oversight bodies. Experimentally determined failure rates are also determined from the data set and can be used to estimate the chances of HEPA filters surviving 15, 20, or even 30 years.

61 RADIATION PROTECTION AND DOSIMETRY↗

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve↗

Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT

Purpose: The combination of quickly rotating C-arm gantry with digital flat panel has enabled the acquisition of three-dimensional data (3D) in the interventional suite. However, image quality is still somewhat limited since the hardware has not been optimized for CT imaging. Adaptive anisotropic filtering has the ability to improve image quality by reducing the noise level and therewith the radiation dose without introducing noticeable blurring. By applying the filtering prior to 3D reconstruction, noise-induced streak artifacts are reduced as compared to processing in the image domain. Methods: 3D anisotropic adaptive filtering was used to process an ensemble of 2D x-ray views acquired along a circular trajectory around an object. After arranging the input data into a 3D space (2D projections + angle), the orientation of structures was estimated using a set of differently oriented filters. The resulting tensor representation of local orientation was utilized to control the anisotropic filtering. Low-pass filtering is applied only along structures to maintain high spatial frequency components perpendicular to these. The evaluation of the proposed algorithm includes numerical simulations, phantom experiments, and in-vivo data which were acquired using an AXIOM Artis dTA C-arm system (Siemens AG, Healthcare Sector, Forchheim, Germany). Spatial resolution and noise levels were compared with and without adaptive filtering. A human observer study was carried out to evaluate low-contrast detectability. Results: The adaptive anisotropic filtering algorithm was found to significantly improve low-contrast detectability by reducing the noise level by half (reduction of the standard deviation in certain areas from 74 to 30 HU). Virtually no degradation of high contrast spatial resolution was observed in the modulation transfer function (MTF) analysis. Although the algorithm is computationally intensive, hardware acceleration using Nvidia's CUDA Interface provided an 8.9-fold speed-up of the processing (from 1336 to 150 s). Conclusions: Adaptive anisotropic filtering has the potential to substantially improve image quality and/or reduce the radiation dose required for obtaining 3D image data using cone beam CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-F-16A-02: Design, Fabrication, and Validation of a 3D-Printed Proton Filter for Range Spreading

Purpose: To design, fabricate and test a 3D-printed filter for proton range spreading in scanned proton beams. The narrow Bragg peak in lower-energy synchrotron-based scanned proton beams can result in longer treatment times for shallow targets due to energy switching time and plan quality degradation due to minimum monitor unit limitations. A filter with variable thicknesses patterned on the same scale as the beam's lateral spot size will widen the Bragg peak. Methods: The filter consists of pyramids dimensioned to have a Gaussian distribution in thickness. The pyramids are 2.5mm wide at the base, 0.6 mm wide at the peak, 5mm tall, and are repeated in a 2.5mm pseudo-hexagonal lattice. Monte Carlo simulations of the filter in a proton beam were run using TOPAS to assess the change in depth profiles and lateral beam profiles. The prototypes were constrained to a 2.5cm diameter disk to allow for micro-CT imaging of promising prototypes. Three different 3D printers were tested. Depth-doses with and without the prototype filter were then measured in a ~70MeV proton beam using a multilayer ion chamber. Results: The simulation results were consistent with design expectations. Prototypes printed on one printer were clearly unacceptable on visual inspection. Prototypes on a second printer looked acceptable, but the micro-CT image showed unacceptable voids within the pyramids. Prototypes from the third printer appeared acceptable visually and on micro-CT imaging. Depth dose scans using the prototype from the third printer were consistent with simulation results. Bragg peak width increased by about 3x. Conclusions: A prototype 3D printer pyramid filter for range spreading was successfully designed, fabricated and tested. The filter has greater design flexibility and lower prototyping and production costs compared to traditional ridge filters. Printer and material selection played a large role in the successful development of the filter.

07 ISOTOPE AND RADIATION SOURCES↗

Impact of bowtie filter and object position on the two-dimensional noise power spectrum of a clinical MDCT system

Purpose: Noise characteristics of clinical multidetector CT (MDCT) systems can be quantified by the noise power spectrum (NPS). Although the NPS of CT has been extensively studied in the past few decades, the joint impact of the bowtie filter and object position on the NPS has not been systematically investigated. This work studies the interplay of these two factors on the two dimensional (2D) local NPS of a clinical CT system that uses the filtered backprojection algorithm for image reconstruction. Methods: A generalized NPS model was developed to account for the impact of the bowtie filter and image object location in the scan field-of-view (SFOV). For a given bowtie filter, image object, and its location in the SFOV, the shape and rotational symmetries of the 2D local NPS were directly computed from the NPS model without going through the image reconstruction process. The obtained NPS was then compared with the measured NPSs from the reconstructed noise-only CT images in both numerical phantom simulation studies and experimental phantom studies using a clinical MDCT scanner. The shape and the associated symmetry of the 2D NPS were classified by borrowing the well-known atomic spectral symbols s, p, and d, which correspond to circular, dumbbell, and cloverleaf symmetries, respectively, of the wave function of electrons in an atom. Finally, simulated bar patterns were embedded into experimentally acquired noise backgrounds to demonstrate the impact of different NPS symmetries on the visual perception of the object. Results: (1) For a central region in a centered cylindrical object, an s-wave symmetry was always present in the NPS, no matter whether the bowtie filter was present or not. In contrast, for a peripheral region in a centered object, the symmetry of its NPS was highly dependent on the bowtie filter, and both p-wave symmetry and d-wave symmetry were observed in the NPS. (2) For a centered region-ofinterest (ROI) in an off-centered object, the symmetry of its NPS was found to be different from that of a peripheral ROI in the centered object, even when the physical positions of the two ROIs relative to the isocenter were the same. (3) The potential clinical impact of the highly anisotropic NPS, caused by the interplay of the bowtie filter and position of the image object, was highlighted in images of specific bar patterns oriented at different angles. The visual perception of the bar patterns was found to be strongly dependent on their orientation. Conclusions: The NPS of CT depends strongly on the bowtie filter and object position. Even if the location of the ROI with respect to the isocenter is fixed, there can be different symmetries in the NPS, which depend on the object position and the size of the bowtie filter. For an isolated off-centered object, the NPS of its CT images cannot be represented by the NPS measured from a centered object.

60 APPLIED LIFE SCIENCES↗

Extended Kalman Filter Performance on the Artemis-1 Mission

The Artemis Program is NASA’s campaign to explore the Moon and beyond. Artemis-1, the uncrewed exoLEO test flight of the Orion spacecraft, was completed in 2022. There were four navigation Extended Kalman Filters (EKFs) that are part of the Orion navigation system. The Atmospheric Extended Kalman Filter (ATMEKF) estimates the vehicle position, velocity, and attitude (referred to as the vehicle state) during the ascent and entry phases of flight. Once Orion is outside of Earths atmosphere, the Earth Orbit Extended Kalman Filter (EOEKF) and CisLunar Extended Kalman Filter (CLEKF) estimate the translational states, depending on the phase of flight, while the Attitude Extended Kalman Filter (ATTEKF) estimates the rotational state of the vehicle. The Kalman filters propagate the vehicle state forward in time using a combination of dynamics models and the output data from the Inertial Measurement Unit (IMU). The filters update the vehicle states and associated uncertainties, in the form of the covariance matrix, using pseudorange measurements from GPS (in ATMEKF/EOEKF), optical navigation measurements of the Earth or Moon (in CLEKF), and star tracker measurements (in ATTEKF). Simultaneously, the Kalman filters estimate error sources in the sensors, which are included in the state vectors as Exponentially Correlated Random Variables (ECRVs). This paper will summarize the performance of these filters during the Artemis-1 mission.

Artemis-1↗

Evaluation of Alternative Filter Media for the Rotary Microfilter

The Savannah River Site is currently developing and testing several processes to treat high level radioactive liquid waste. Each of these processes has a solid-liquid separation process that limits its throughput. Savannah River National Laboratory researchers identified and tested the rotary microfilter as a technology to increase solid-liquid separation throughput. The authors believe the rotary microfilter throughput can be improved by using a better filter membrane. Previous testing showed that asymmetric filters composed of a ceramic membrane on top of a stainless steel support produced higher filter flux than 100% stainless steel symmetric filters in crossflow filter tests. Savannah River National Laboratory and Oak Ridge National Laboratory are working together to develop asymmetric ceramic ? stainless steel composite filters and asymmetric 100% stainless steel filters to improve the throughput of the rotary microfilter. The Oak Ridge National Laboratory Inorganic Membrane Group fabricated samples of alternative filter membranes. In addition, Savannah River National Laboratory obtained samples of filter membranes from Pall, Porvair, and SpinTek. They tested these samples in a static test cell with feed slurries containing monosodium titanate and simulated sludge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation of Axial Flow AG-1 FC and Prototype FM (High Strength) HEPA Filters - 13123

High efficiency particulate air (HEPA) filters are routinely used in DOE nuclear containment activities. The Nuclear Air Cleaning Handbook (NACH) stipulates that air cleaning devices and equipment used in DOE nuclear applications must meet the American Society of Mechanical Engineers (ASME) Code on Nuclear Air and Gas Treatment (AG-1) standard. This testing activity evaluates two different axial flow HEPA filters, those from AG-1 Sections FC and FM. Section FM is under development and has not yet been added to AG-1 due to a lack of qualification data available for these filters. Section FC filters are axial flow units that utilize a fibrous glass filtering medium. The section FM filters utilize a similar fibrous glass medium, but also have scrim backing. The scrim-backed filters have demonstrated the ability to endure pressure impulses capable of completely destroying FC filters. The testing activities presented herein will examine the total lifetime loading for both FC and FM filters under ambient conditions and at elevated conditions of temperature and relative humidity. Results will include loading curves, penetration curves, and testing condition parameters. These testing activities have been developed through collaborations with representatives from the National Nuclear Security Administration (NNSA), DOE Office of Environmental Management (DOE-EM), New Mexico State University, and Mississippi State University. (authors)

42 ENGINEERING↗

DEVELOPMENT OF AG-1 SECTION FI ON METAL MEDIA FILTERS - 9061

Development of a metal media standard (FI) for ASME AG-1 (Code on Nuclear Air and Gas Treatment) has been under way for almost ten years. This paper will provide a brief history of the development process of this section and a detailed overview of its current content/status. There have been at least two points when dramatic changes have been made in the scope of the document due to feedback from the full Committee on Nuclear Air and Gas Treatment (CONAGT). Development of the proposed section has required resolving several difficult issues associated with scope; namely, filtering efficiency, operating conditions (media velocity, pressure drop, etc.), qualification testing, and quality control/acceptance testing. A proposed version of Section FI is currently undergoing final revisions prior to being submitted for balloting. The section covers metal media filters of filtering efficiencies ranging from medium (less than 99.97%) to high (99.97% and greater). Two different types of high efficiency filters are addressed; those units intended to be a direct replacement of Section FC fibrous glass HEPA filters and those that will be placed into newly designed systems capable of supporting greater static pressures and differential pressures across the filter elements. Direct replacements of FC HEPA filters in existing systems will be required to meet equivalent qualification and testing requirements to those contained in Section FC. A series of qualification and quality assurance test methods have been identified for the range of filtering efficiencies covered by this proposed standard. Performance characteristics of sintered metal powder vs. sintered metal fiber media are dramatically different with respect to parameters like differential pressures and rigidity of the media. Wide latitude will be allowed for owner specification of performance criteria for filtration units that will be placed into newly designed systems. Such allowances will permit use of the most appropriate metal media for a system as specified by the owner with respect to material of manufacture, media velocity, system maximum static pressure, maximum differential pressure across the filter, and similar parameters.

54 ENVIRONMENTAL SCIENCES↗

A priori filtered chemical source term modeling for LES of high Karlovitz number premixed flames

Assumptions behind closure models for the filtered source term are studied a priori using results from DNS of turbulent n-heptane/air premixed flames at varying Karlovitz numbers. Simulations with both detailed chemistry and tabulated chemistry, as well as unity and non-unity Lewis numbers, are used to determine if finite-rate chemistry and differential diffusion effects affect the filtered chemical source terms. While the unfiltered source term shows large fluctuations, the filtered source terms from detailed chemistry and tabulated chemistry are in good agreement at sufficiently large filter widths (Δ ≳ l F ). Using the concept of optimal estimators, it is shown that a tabulation approach using the filtered progress variable and its variance can predict accurately the filtered chemical source terms. Finally, the filtered source terms from the DNS are compared to predictions from two commonly assumed sub-filter probability density function models. Both models show deviations from the filtered DNS source terms but predict accurately the mean turbulent flame speed. In conclusion, the results illustrate the potential of using simple tabulated chemistry approaches based on presumed PDFs for LES of premixed flames in the thin and distributed reaction zones regimes.

33 ADVANCED PROPULSION SYSTEMS↗

Filtration of bioaerosols using a granular metallic filter with micrometer-sized collectors

Several experimental studies with granular bed filters composed of micrometer-sized spherical or sintered metallic granules have demonstrated their use in aerosol filtration. However, the effectiveness of these metallic membrane filters against bioaerosols has not been established. In this work, the filtration efficiency and filter quality of these filters against airborne B. subtilis endospore and MS2 virus were determined as a function of face velocity and loading time. In experiments, a physical removal efficiency greater than 99.9% and a viable removal efficiency of greater than 5-log were observed for both bacterial spore and viral aerosols. A lower face velocity produced both higher collection efficiency and filter quality for virus but was not statistically significant for spore filtration. Although the filter had high filtration efficiency of the test bioaerosols, the filter's high pressure drop resulted in a low filter quality (0.25-0.75 kPa- 1). Overall, filters with micrometer-sized collectors capture bioaerosols effectively but their applications in aerosol filtration may be limited by their high pressure drop.

aerosol↗

Energy spectra, sources, and shielding considerations for neutrons generated by a flattening filter-free Clinac

Neutron production is an unwanted result of high-energy radiation therapy and results in secondary exposure of patients and radiation therapists to radiation. Recent studies have shown that delivering therapy using a standard medical accelerator with the flattening filter removed may reduce neutron fluence by nearly 70% over the course of prostate intensity-modulated radiation therapy (IMRT). In the current study, the {sup 197}Au Bonner sphere technique was used to compare the neutron spectrum produced when the filter is present and when it is absent. In addition, the following was calculated: (1) the neutron-shielding parameters of source strength and ambient dose equivalent (H{sub 0}) and (2) using the Monte Carlo technique, the sources of neutron production in the accelerator head. It was found that the neutron spectrum was nearly constant, regardless of the presence of the flattening filter; however, the total fluence and ambient dose equivalent over the course of prostate IMRT were more than 70% lower when the filter was removed. Similarly, shielding parameters were lower when the filter was removed. Finally, the primary collimator and jaws accounted for the majority of neutron production, both with and without the flattening filter; however, with the flattening filter removed, the upper jaw accounted for much more neutron production relative to when the filter was present. Ultimately, removal of the flattening filter may offer several clinical advantages, including a reduction in the dose from neutrons to the patient and to radiation personnel.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-G-18A-08: Axial Cone Beam DBPF Reconstruction with Three-Dimensional Weighting and Butterfly Filtering

Purpose: With the major benefit in dealing with data truncation for ROI reconstruction, the algorithm of differentiated backprojection followed by Hilbert filtering (DBPF) is originally derived for image reconstruction from parallel- or fan-beam data. To extend its application for axial CB scan, we proposed the integration of the DBPF algorithm with 3-D weighting. In this work, we further propose the incorporation of Butterfly filtering into the 3-D weighted axial CB-DBPF algorithm and conduct an evaluation to verify its performance. Methods: Given an axial scan, tomographic images are reconstructed by the DBPF algorithm with 3-D weighting, in which streak artifacts exist along the direction of Hilbert filtering. Recognizing this orientation-specific behavior, a pair of orthogonal Butterfly filtering is applied on the reconstructed images with the horizontal and vertical Hilbert filtering correspondingly. In addition, the Butterfly filtering can also be utilized for streak artifact suppression in the scenarios wherein only partial scan data with an angular range as small as 270° are available. Results: Preliminary data show that, with the correspondingly applied Butterfly filtering, the streak artifacts existing in the images reconstructed by the 3-D weighted DBPF algorithm can be suppressed to an unnoticeable level. Moreover, the Butterfly filtering also works at the scenarios of partial scan, though the 3-D weighting scheme may have to be dropped because of no sufficient projection data are available. Conclusion: As an algorithmic step, the incorporation of Butterfly filtering enables the DBPF algorithm for CB image reconstruction from data acquired along either a full or partial axial scan.

60 APPLIED LIFE SCIENCES↗

SU-C-207-06: In Vivo Quantification of Gold Nanoparticles Using K-Edge Imaging Via Spectrum Shaping by Gold Filter

Purpose: Gold nanoparticles (AuNP) are multifunctional platforms ideal for drug delivery, targeted imaging and radiosensitization. We have investigated quantitative imaging of AuNPs using on board imager (OBI) cone beam computed tomography (CBCT). To this end, we also present, for the first time, a novel method for k-edge imaging of AuNP by filter-based spectral shaping. Methods: We used a digital 25 cm diameter water phantom, embedded with 3 cm spheres filled with AuNPs of different concentrations (0 mg/ml – 16 mg/ml). A poly-energetic X-ray spectrum of 140 kVp from a conventional X-ray tube is shaped by balanced K-edge filters to create an excess of photons right above the K-edge of gold at 80.7 keV. The filters consist of gold, tin, copper and aluminum foils. The phantom with appropriately assigned attenuation coefficients is forward projected onto a detector for each energy bin and then integrated. FKD reconstruction is performed on the integrated projections. Scatter, detector efficiency and noise are included. Results: We found that subtracting the results of two filter sets (Filter A:127 µm gold foil with 254 µm tin, 330 µm copper and 1 mm aluminum, and Filter B: 635 µm tin with 264 µm copper and 1 mm aluminum), provides substantial image contrast. The resulting filtered spectra match well below 80.7 keV, while maintaining sufficient X-ray quanta just above that. Voxel intensities of AuNP containing spheres increase linearly with AuNP concentration. K-edge imaging provides 18% more sensitivity than the tin filter alone, and 38% more sensitivity than the gold filter alone. Conclusion: We have shown that it is feasible to quantitatively detect AuNP distributions in a patient-sized phantom using clinical CBCT and K-edge spectral shaping.

60 APPLIED LIFE SCIENCES↗