Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A general form for the dissipation length scale in turbulent shear flows

It has been found that, for a wide range of turbulent wall-bounded shear flows with mean velocity profile U(y), the scale length L-epsilon determining the dissipation is approximately described in terms of distance from the wall (y), the mean shear (dU/dy), and the variance of the normal component of turbulence (bar u-squared), by the formula: L-epsilon to the -1 power is approximately equal to (A sub B / y) + A sub S (dU/dy / square root of bar u-squared) where L-epsilon = epsilon/(bar u-squared) to the 3/2 power. To match with shear-free boundary layers, A sub B is approximately 0.27, and to match with the log layer, A sub S is approximately 0.46. The shear flows tested here were: boundary layers over a flat plate, sink flow, oscillatory flow, and channel flow. The use of the square root of bar u-squared as a velocity scale minimizes the effects of Reynolds number. However, the formula fails within a distance of order L-epsilon for the regions where dU/dy = 0.

Hunt, J. C. R.↗

Effect of Taper Ratio on the Low-speed Rolling Stability Derivatives of Swept and Unswept Wings of Aspect Ratio 2.61

Results of tests conducted in the 6-foot-diameter rolling-flow test section of the Langley stability tunnel to determine the effects of varying taper ratio on the rolling and static stability characteristics of a swept wing are presented; results are also given for the effects of varying taper ratio on an unswept wing and for the effects of sweep on a tapered wing. All the models were of aspect ratio 2.61 and had NACA 0012 sections normal to the quarter-chord line. Taper ratios of 1.00, 0.50, and 0.25 and sweep angles of 0 degrees and 45 degrees were investigated.

WINGS, COMPLETE - SWEEP↗

Software interface verifier

A Telos study of 40 recent subsystem deliveries into the DSN at JPL found software interface testing to be the single most expensive and error-prone activity, and the study team suggested creating an automated software interface test tool. The resulting Software Interface Verifier (SIV), which was funded by NASA/JPL and created by Telos, employed 92 percent software reuse to quickly create an initial version which incorporated early user feedback. SIV is now successfully used by developers for interface prototyping and unit testing, by test engineers for formal testing, and by end users for non-intrusive data flow tests in the operational environment. Metrics, including cost, are included. Lessons learned include the need for early user training. SIV is ported to many platforms and can be successfully used or tailored by other NASA groups.

Soderstrom, Tomas J.↗

A concept for transition mapping on a 10 deg-cone in the National Transonic Facility using flow-pressure variation

A conceptual study was performed to define a technique for mapping the boundary-layer transition on a 10 deg-Cone in the National Transonic Facility (NTF) as a means of determining this cryogenic-tunnel suitability for laminar flow testing. A major challenge was to devise a test matrix using a fixed surface pitot probe, varying the flow pressure to pr oduce the actual Reynolds numbers for boundary-layer transition. This constraint resulted from a lack of a suitable and reliable electrical motor to drive the probe along the cone's surface under cryogenic flow conditions. The initial phase of this research was performed by the author in collaboration with the late Dr. William B. Igoe from the Aerodynamics Division at NASA Langley Research Center. His comments made during the drafting of this document were invaluable and a source of inspiration.

Gartenberg, Ehud↗

Heating rate distributions at Mach 10 on a circular body earth-to-orbit transport vehicle

A 0.0055-scale model of a single-stage-to-orbit transport vehicle with a circular body configuration was tested at Mach 10 to obtain heat transfer measurements and surface flow patterns. Phase-change paint and oil-flow tests were performed in the Langley 31-Inch Mach-10 Tunnel at angles of attack from 20 through 40 deg in 5-deg increments. Heat-transfer coefficient data are given for all angles of attack, and detailed oil-flow photographs are presented for windward and leeward surfaces at 25 and 40 deg angle of attack. Heating was found to similar to that previously determined for the Space Shuttle Orbiter, so that existing thermal protection systems would appear to be adequate for the proposed circular-body configurations.

Wells, W. L.↗

Static and Wind Tunnel Aero-Performance Tests of NASA AST Separate Flow Nozzle Noise Reduction Configurations

This report presents the results of cold flow model tests to determine the static and wind tunnel performance of several NASA AST separate flow nozzle noise reduction configurations. The tests were conducted by Aero Systems Engineering, Inc., for NASA Glenn Research Center. The tests were performed in the Channels 14 and 6 static thrust stands and the Channel 10 transonic wind tunnel at the FluiDyne Aerodynamics Laboratory in Plymouth, Minnesota. Facility checkout tests were made using standard ASME long-radius metering nozzles. These tests demonstrated facility data accuracy at flow conditions similar to the model tests. Channel 14 static tests reported here consisted of 21 ASME nozzle facility checkout tests and 57 static model performance tests (including 22 at no charge). Fan nozzle pressure ratio varied from 1.4 to 2.0, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Channel 10 wind tunnel tests consisted of 15 tests at Mach number 0.28 and 31 tests at Mach 0.8. The sting was checked out statically in Channel 6 before the wind tunnel tests. In the Channel 6 facility, 12 ASME nozzle data points were taken and 7 model data points were taken. In the wind tunnel, fan nozzle pressure ratio varied from 1.73 to 2.8, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Test results include thrust coefficients, thrust vector angle, core and fan nozzle discharge coefficients, total pressure and temperature charging station profiles, and boat-tail static pressure distributions in the wind tunnel.

Mikkelsen, Kevin L.↗

Development of an in-vitro circulatory system with known resistance and capacitance

An in-vitro (hydrodynamic) model of the circulatory system was developed. The model consisted of a pump, compliant tubing, and valves for resistance. The model is used to simulate aortic pressure and flow. These parameters were measured using a Konigsburg Pressure transducer and a Triton ART2 flow probe. In addition, venous pressure and flow were measured on the downstream side of the resistance. The system has a known compliance and resistance. Steady and pulsatile flow tests were conducted to determine the resistance of the model. A static compliance test was used to determine the compliance of the system. The aortic pressure and flow obtained from the hydrodynamic model will be used to test the accuracy of parameter estimation models such as the 2-element and 4-element Windkessel models and the 3-element Westkessel model. Verifying analytical models used in determining total peripheral resistance (TPR) and systemic arterial compliance (SAC) is important because it provides insight into hemodynamic parameters that indicate baroreceptor responsiveness to situations such as changes in gravitational acceleration.

NASA Discipline Cardiopulmonary↗

Investigation of Two-Phase Flows in Piping Bends and Elbows

An experimental investigation of the hydrodynamic characteristics of two-phase R-113 flow has been carried out. Straight tube pressure drop data, as a function of mass flow rate (mass flux) and flow quality has been obtained using the Two-Phase Flow Test Facility located in the Advanced Thermal Laboratories of the Crew and Thermal Systems Division at the Lyndon B. Johnson Space Center. Additionally, after successfully obtaining the straight tube pressure drop data, the test facility was modified in order to obtain pressure drop data for the flow of two-phase R-113 through 180 deg piping bends. Inherent instabilities of the test facility prevented the successful acquisition of pressure drop data through the piping bends. The experimental straight tube data will be presented and compared with existing predictive correlations in an attempt to gain insight into the utility of such correlations as the basis for developing design criteria. A discussion of the instabilities which rendered successful acquisition of the piping bend data will be presented and suggestions will be made for eliminating these system tendencies. Finally, recommendations for future investigations, based on successful reconfiguration of the test facility, will be made.

Duncan, Allen B.↗

Experimental performance of a 13.65-centimeter-tip-diameter tandem-bladed sweptback centrifugal compressor designed for a pressure ratio of 6

A 13.65 cm tip diameter backswept centrifugal impeller having a tandem inducer and a design mass flow rate of 0.907 kg/sec was experimentally investigated to establish stage and impeller characteristics. Tests were conducted with both a cascade diffuser and a vaneless diffuser. A pressure ratio of 5.9 was obtained near surge for the smallest clearance tested. Flow range at design speed was 6.3 percent for the smallest clearance test. Impeller exit to shroud axial clearance at design speed was varied to determine the effect on stage and impeller performance.

Klassen, H. A.↗

Autoignition characteristics of aircraft-type fuels

The ignition delay characteristics of Jet A, JP 4, no. 2 diesel, cetane and an experimental referee broad specification (ERBS) fuel in air at inlet temperatures up to 1000 K, pressures of 10, 15, 20, 25 and 30 atm, and fuel air equivalence ratios of 0.3, 0.5, 0.7 and 1.0 were mapped. Ignition delay times in the range of 1 to 50 msec at freestream flow velocities ranging from 20 to 100 m/sec were obtained using a continuous flow test apparatus which permitted independent variation and evaluation of the effect of temperature, pressure, flow rate, and fuel/air ratio. The ignition delay times for all fuels tested appeared to correlate with the inverse of pressure and the inverse exponent of temperature. With the exception of pure cetane, which had the shortest ignition delay times, the differences between the fuels tested did not appear to be significant. The apparent global activation energies for the typical gas turbine fuels ranged from 38 to 40 kcal/mole, while the activation energy determined for cetane was 50 kcal/mole. In addition, the data indicate that for lean mixtures, ignition delay times decrease with increasing equivalence ratio. It was also noted that physical (apparatus dependent) phenomena, such as mixing (i.e., length and number of injection sites) and airstream cooling (due to fuel heating, vaporization and convective heat loss) can have an important effect on the ignition delay.

Spadaccini, L. J.↗

Development of an impact- and solvent-resistant thermoplastic composite matrix, phase 4

Polyimides from BTDA with m-phenylenediamine and three aliphatic diamines were prepared in cresol and characterized. Characterization tests included compression strength and modulus, stressed solvent resistance, and melt-flow tests. Efforts to reduce the molecular weights of these polymers by either stoichiometric imbalance or phthalic anhydride end capping produced opacity in the polymer moldings when the stoichiometry was less than 99 percent. Use of 2,4-diaminotoluene in place of the m-phenylenediamine allowed clear polymer moldings to be obtained at all stoichiometries by end capping or stoichiometric imbalance. After melt-flow/molecular-weight studies, carbon fabric composites were prepared from three polyimide compositions containing BTDA, 2,4-diaminotoluene and two aliphatic diamines. Flexural strengths of two of the resins were in excess of 689 MPa (100 ksi) at both room temperature and 93 C. The polyimide from BTDA was selected for scale-up and neat resin characterization tests. The Tg of this polymer was 233 C.

Delano, C. B.↗

Radiative, actively cooled panel tests results

The radiative, actively cooled panel designed to withstand a uniform incident heat flux of 136 kW/sq m to a 444 K surface temperature was evaluated. The test program consisted of preliminary static thermal mechanical loading and aerothermal flow tests. Test results are briefly discussed.

Shore, C. P.↗

A Semi-Empirical Correlation for the Onset of Density Wave Oscillations in a Helical Coil Steam Generator

NuScale Power has completed full length helical coil steam generator (HCSG) tests at SIET Laboratories in Piacenza, Italy. The test program included an investigation of the onset and evolution of density wave oscillations (DWO). This paper describes the mechanisms leading to the onset of DWO as inferred from tests performed in the full-height TF-2 counter-flow test facility. This research supports the concept that the onset of DWO is caused by liquid bridging inside the boiling length of the tubes. Using a separate cylinders approximation, a DWO onset correlation is obtained by performing a steady-state momentum balance on the density front created by liquid bridging. This yields a momentum balance equation in terms of a set of dimensionless superficial velocities, a corresponding dimensionless pressure drop term and an average void fraction. Envelope theory is then used to obtain a critical void fraction which is substituted into the dimensionless momentum balance to obtain a DWO onset correlation similar to the Wallis counter-current flooding correlation. A comparison of the DWO onset correlation to the TF-2 DWO experimental data is presented and shows excellent agreement when the average equilibrium vapor quality is greater than 0.2.

Density Wave Oscillations, Helical Coil Steam Gene↗

Visco-inertial gas flow through wellbore cement fractures

Understanding the nature of fluid flow through fractured wellbore cement is fundamental for evaluating the leakage potential and risk assessments of leaky wellbores. In this study, the conditions that require considering visco-inertial flow for describing the gas flow through wellbore cement fractures were investigated. Nitrogen gas flow tests were conducted on fractured cement samples under varying pressure conditions and flow rates, covering both viscous and visco-inertial flow regimes. The data substantially deviated from Darcy's law at higher flowrates and were well-fit to Forchheimer's equation for visco-inertial flow. The inertial coefficient and critical Reynolds number were expressed as a function of the hydraulic aperture. Finally, the empirical function obtained from the experiments was used as an input to numerical simulations which showed the significant role of visco-inertial flow in wellhead pressure build-up and leakage rates, and demonstrated the importance of visco-inertial flow when modeling gas flow through wellbore cement fractures.

03 NATURAL GAS↗

Nuclear thermal propulsion test facility requirements and development strategy

The Nuclear Thermal Propulsion (NTP) subpanel of the Space Nuclear Propulsion Test Facilities Panel evaluated facility requirements and strategies for nuclear thermal propulsion systems development. High pressure, solid core concepts were considered as the baseline for the evaluation, with low pressure concepts an alternative. The work of the NTP subpanel revealed that a wealth of facilities already exists to support NTP development, and that only a few new facilities must be constructed. Some modifications to existing facilities will be required. Present funding emphasis should be on long-lead-time items for the major new ground test facility complex and on facilities supporting nuclear fuel development, hot hydrogen flow test facilities, and low power critical facilities.

Allen, George C.↗

Hypersonic Boundary-Layer Stability Experiments on a Flared-Cone Model at Angle of Attack in a Quiet Wind Tunnel

An experimental investigation of the effects of angle of attack on hypersonic boundary-layer stability on a flared-cone model was conducted in the low-disturbance Mach-6 Nozzle-Test Chamber Facility at NASA Langley Research Center. This unique facility provided a 'quiet' flow test environment which is well suited for stability experiments because the low levels of freestream 'noise' minimize artificial stimulation of flow-disturbance growth. Surface pressure and temperature measurements documented the adverse-pressure gradient and transition-onset location. Hot-wire anemometry diagnostics were applied to identify the instability mechanisms which lead to transition. In addition, the mean flow over the flared-cone geometry was modeled by laminar Navier-Stokes computations. Results show that the boundary layer becomes more stable on the windward ray and less stable on the leeward ray relative to the zero-degree angle-of-attack case. The second-mode instability dominates the transition process at a zero-degree angle of attack, however, on the windward ray at an angle of attack this mode was completely stabilized. The less-dominant first-mode instability was slightly destabilized on the windward ray. Non-linear mechanisms such as saturation and harmonic generation are identified from the flow-disturbance bispectra.

Doggett, Glen P.↗

Evaluation of Lost Circulation Material Sealing for Geothermal Drilling

Lost circulation is a pervasive problem in geothermal wells that can create prohibitive costs during drilling. The main issue with treatment is that the mechanism of plug formation is poorly understood. Here we applied two experimental approaches to characterize the clogging effectiveness of different materials. Fracture flow tests with different geometries were conducted with various individual materials and mixtures at relevant conditions. A high-temperature flow loop system was also developed to inject single- and mixed-material plugs into a gravel pack with a non-uniform geometry to compare with the fracture tests. The fracture tests revealed that single materials tended to form no plug or an unstable plug, while mixtures of materials were uniformly better at sealing fractures. Gravel pack tests at high temperatures show most of the materials are intact but degraded. The fibrous materials can create partial or unstable plugs in the gravel pack, but mixed-material plugs are far more effective at clogging. Both test types suggest that (1) mixed materials are more effective at blocking fluid flow and (2) fibrous materials seal fracture openings better, while granular materials seal inside fractures or pore throats better. Further research is needed to study the long-term stability of different plug configurations.

clogging tests↗