Comparison of Pre- and Post-Flight Estimations of Pitch Damping Coefficients for Unguided Entry Vehicles

Introduction: Pre-flight predictions of pitch damping coefficient (𝐶!!+𝐶!"̇)curves are used in entry simulations to determine flight readiness and if any dynamic remediation strategies are required. Accurate characterization of these pitch damping coefficient curves is crucial for mission success. Historically, pre-flight estimations of these curves are derived experimentally either via ballistic range testing or with 1-degree-of-freedom (DOF) free-or forced-oscillation wind tunnel testing. Methodology:With post-flight best-estimated trajectories, a fitting procedure as described in Karlgaard, et. al. [1] is used to compare pre-and post-flight pitch damping coefficients. This technique relies on an assumed analytical form of the trajectory, a limited 3-DOF representation described in Schoenenbergerand Queen [2], which results in anEuler-Cauchy solution form.This solution assumes constant density,thus limited amplitude multi-peak windows of the trajectory are considered to populate the pitch damping-amplitudes pace. Fig. 1 shows preliminary estimations of the pitch damping coefficients estimated using the post-flight best estimated trajectoryfor MER B, using a3-amplitude-peak window. Important to note is that the Euler-Cauchy solution also assumes planar motion, thus coning or 𝛽contribution is not included. Further,the estimated post-flight pitch damping approximations and the pre-flight predictions shown are effective representations of pitch damping, or the integrated effect of the pitch damping coefficient over one pitch cycle at the corresponding cycle’s peak amplitude. Effective pitch damping coefficient curves provide more intuitive insights about where the vehicle is stable and permits readily processed comparisons between data-sets. It is important to note that most pitch damping curves, such as those reported in aerodatabases and utilized in flight mechanics trajectory simulations, are represented in instantaneous angle-of-attack space distinct from what is presented in Fig 1. The extracted post-flight pitch damping coefficient points show a wide range of values across a narrow band of amplitudes (Fig.1a), albeit centered on the published pre-flight approximation. This also applies to the prediction as a function of Mach in Fig1b, where the post-flight scatter points are centered around the pre-flight predictions, but the pre-flight predictions notably lack data aboveMach 5.Further tuning of the technique, such as changing the number of peaks considered in each stencil, resolving density in higher resolution, and employing more accurate fitting procedures (beyond scipy.curve_fit()), will be performed. PosterFocus:This study will apply this reconstruction method to the as-flown trajectories for the following unguided entry vehicles: MER A, MER B, IRVE3, Phoenix, Insight, Pathfinder, and SIAD. The pitch damping coefficient will be derived from these trajectories and compared with the pre-flight predictions. Comparing across different missions, entry environments, and vehicle geometries can inform where our pre-flight testing methodologies accurately capture the flight dynamics. Results will provide valuable insight into the accuracy of pre-flight predicted pitch damping curves. Beyond that, this method can shed light on how accurate these curves need to be, which can inform uncertainty ranges applied to pre-flight curves for other missions.

pitch damping coefficient↗

Synthesis and transport properties of epitaxial Bi (111) films on GaAs (111) substrates

In recent decades, the growth of ultrathin epitaxial bismuth (Bi) films on various substrates has garnered interest due to their unique electronic properties. We report upon the growth and electrical transport properties of epitaxial Bi (111) films in the thickness range of 5–32 nm deposited directly on GaAs (111) substrates, without a buffer layer. The quality of Bi films is found to depend on conditions for substrate treatment using Ar + ion-milling and annealing. Substrates milled at low ion beam currents display poor surface reconstruction after annealing, which hinders the growth of high-quality films. In contrast, substrates milled under optimized conditions led to reconstructed surfaces upon annealing, resulting in epitaxial Bi films with predominantly single-domain orientation. Although epitaxial films formed in both cases, transport measurements indicated significantly higher conductivity for films grown on optimally treated substrates. Measurements at low temperatures suggest that the transport properties are dominated by a surface state with high mobility electrons. Magneto-transport measurements suggest that conductivity and mobility improve progressively with increasing film thickness. For the thinnest 5 nm film, a hole-like state emerges, presumably as the electron-like state is gapped out. These results provide a robust methodology for growing high-quality epitaxial Bi films on GaAs (111) and offer insights into their unique transport properties and our ability to tune them.

Atomic force microscopy↗

Experimental Investigation of Pool Boiling Heat Transfer Enhancement in Microgravity in the Presence of Electric Fields

In boiling high heat fluxes are possible driven by relatively small temperature differences, which make its use increasingly attractive in aerospace applications. The objective of the research is to develop ways to overcome specific problems associated with boiling in the low gravity environment by substituting the buoyancy force with the electric force to enhance bubble removal from the heated surface. Previous studies indicate that in terrestrial applications nucleate boiling heat transfer can be increased by a factor of 50, as compared to values obtained for the same system without electric fields. The goal of our research is to experimentally explore the mechanisms responsible for EHD heat transfer enhancement in boiling in low gravity conditions, by visualizing the temperature distributions in the vicinity of the heated surface and around the bubble during boiling using real-time holographic interferometry (HI) combined with high-speed cinematography. In the first phase of the project the influence of the electric field on a single bubble is investigated. Pool boiling is simulated by injecting a single bubble through a nozzle into the subcooled liquid or into the thermal boundary layer developed along the flat heater surface. Since the exact location of bubble formation is known, the optical equipment can be aligned and focused accurately, which is an essential requirement for precision measurements of bubble shape, size and deformation, as well as the visualization of temperature fields by HI. The size of the bubble and the frequency of bubble departure can be controlled by suitable selection of nozzle diameter and mass flow rate of vapor. In this approach effects due to the presence of the electric field can be separated from effects caused by the temperature gradients in the thermal boundary layer. The influence of the thermal boundary layer can be investigated after activating the heater at a later stage of the research. For the visualization experiments a test cell was developed. All four vertical walls of the test cell are transparent, and they allow transillumination with laser light for visualization experiments by HI. The bottom electrode is a copper cylinder, which is electrically grounded. The copper block is heated with a resistive heater and it is equipped with 6 thermocouples that provide reference temperatures for the measurements with HI. The top electrode is a mesh electrode. Bubbles are injected with a syringe into the test cell through the bottom electrode. The working fluids presently used in the interferometric visualization experiments, water and PF 5052, satisfy requirements regarding thermophysical, optical and electrical properties. A 30kV power supply equipped with a voltmeter allows to apply the electric field to the electrodes during the experiments. The magnitude of the applied voltage can be adjusted either manually or through the LabVIEW data acquisition and control system connected to a PC. Temperatures of the heated block are recorded using type-T thermocouples, whose output is read by a data acquisition system. Images of the bubbles are recorded with 35mm photographic and 16mm high-speed cameras, scanned and analyzed using various software packages. Visualized temperature fields HI allows the visualization of temperature fields in the vicinity of bubbles during boiling in the form of fringes. Typical visualized temperature distributions around the air bubbles injected into the thermal boundary layer in PF5052 are shown. The temperature of the heated surface is 35 C. The temperature difference for a pair of fringes is approximately 0.05 C. The heat flux applied to the bottom surface is moderate, and the fringe patterns are regular. In the image a bubble penetrating the thermal boundary layer is visible. Because of the axial symmetry of the problem, simplified reconstruction techniques can be applied to recover the temperature field. The thermal plume developing above the heated surface for more intensive heating is shown. The temperature distribution in the liquid is clearly 3D, and tomographic techniques have to be applied to recover the temperature distribution in such a physical situation. A sequence of interferometric images showing the temperature distribution around the rising bubble, recorded with a high-speed camera is shown. Again, the temperature distribution is 3D, and a more complex approach to the evaluation, the tomographic reconstruction has to be taken. Measurement of the temperature distribution from the fringe pattern temperature distributions that yield important information regarding heat transfer are determined. Two algorithms that allow the quantitative evaluation of interferometric fringe patterns and the reconstruction of temperature fields during boiling have been developed at the Heat Transfer Laboratory of the Johns Hopkins University. In the first algorithm the bubble is assumed to be axially symmetrical, which significantly reduces the computational effort for quantifying the temperature distribution around the bubble. For this purpose the thermal boundary layer around the bubble is divided into equidistant concentric shells, and the refractive index is assumed to be constant in each of the shells. Since large temperature gradients are expected in the vicinity of the bubble during boiling, the deflection of the light beam cannot be neglected in boiling experiments. Since the exit angle of the light beam is known, this allows to account for the deflections and phase shifts outside the boundary layer (in the bulk fluid and in the windows of the test cell). Three dimensional temperature distributions in the vicinity of the bubble are reconstructed using tomographic techniques. In tomography, the measurement volume is sliced into 2D planes. In the present study these planes are parallel to the heated surface. The objective is to determine the values of the field parameter of interest in form of the field function in these 2D planes. The field parameter is the change of the refractive index of the liquid in the measurement volume caused by temperature changes. By superimposing data for many 2D planes recorded at the same time instant, the 3D temperature distribution in the measurement volume is recovered.

Herman, Cila↗