Search NASA⌕ Search

SEARCH · Search NASA

Results for “forensics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Intrinsic dosimetry of glass containers: A potential interrogation tool for nuclear forensics and waste management

Intrinsic dosimetry is the method of measuring total absorbed dose received by the walls of a container holding radioactive material. By considering the total absorbed dose received by a container in tandem with the physical characteristics of the radioactive material housed within that container, this method has the potential to provide law enforcement officials or waste management personnel with enhanced pathway information regarding the history of the container and its radioactive contents. We report the latest in a series of experiments designed to validate and demonstrate this newly developed tool. Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass with time up to 60 days after gamma ray, x-ray, beta particle or ultraviolet irradiations at doses from 0.15 to 20 Gy. Two peaks were identified in the TL glow curve when irradiated with 60Co, a relatively unstable peak around 120°C and a more stable peak around 225°C. Signal strength of both peaks decayed with time. The minimum measurable dose using this technique was measured to be 0.15 Gy, which is roughly equivalent to a 24 hr irradiation at 1 cm from a 50 ng source of 60Co. After fading, this dose would still be observable approximately 1 year post-irradiation. Similar doses with beta particles and x-rays produced TL glow curves of lower intensity. The TL glow curves were separated into five peaks centered at approximately 120, 160, 225, 300, and 340°C. Differences in TL glow curve shape and intensity were observed for the glasses from different geographical origins. These differences can be explained by changes in the intensities of the five peaks. EPR results showed production of BOHC and E’ silica centers.

Clark, Richard A.↗

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory ↗

Metal alloy microparticle tagging of UO 2 fuel pellets for nuclear forensics

A tagging strategy for UO 2 fuel pellets will be discussed which involves the creation of alloyed metal microparticles that can be tuned to create a unique identification (“barcode”) indicating provenance of the pellets. These specialized markers would contain high temperature resistant materials, such as Ti, Mo, and Cr, in small quantities such that they do not interfere with the performance of the pellets but are recoverable by standard analytical techniques. The Amazemet rePowder ultrasonic atomization system was used to manufacture the microparticles, and sample pellets were fabricated and sintered containing these dopants. Various techniques, such as Scanning Electron Microscopy (SEM) and Electron Probe Microanalysis (EPMA), were used to evaluate these sample pellets to determine if particles (and their alloy compositions) were recoverable. Details on how the particles were manufactured and characterized will be detailed, as well as results from their incorporation into test pellets. Next steps will involve the scale of this technique using more conventional mass production methods, as well as the implementation of other alloys.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pond Crash Forensics: Presumptive identification of pond crash agents by next generation sequencing in replicate raceway mass cultures of Nannochloropsis salina

Productivity of algal mass culture can be severely reduced by contaminating organisms. It is, therefore, important to identify contaminants, determine their effect on productivity and, ultimately, develop countermeasures against such contamination. In this paper, we utilized microbiome analysis by second-generation sequencing of small subunit rRNA genes to characterize the predator and pathogen burden of open raceway cultures of Nannochloropsis salina. Samples were analyzed from replicate raceways before and after crashes. In one culture cycle, we identified two algivorous species, the rotifer Brachionus and gastrotrich Chaetonotus, the presence of which may have contributed to the loss of algal biomass. In the second culture cycle, the raceways were treated with hypochlorite in an unsuccessful attempt to interdict the crash. Finally, our analyses were shown to be an effective strategy for the identification of the biological contaminants and the characterization of intervention strategies.

59 BASIC BIOLOGICAL SCIENCES↗

Benchmarking the repeatability of a pneumatic cyclic neutron activation analysis facility using 16 O(n,p) 16 N for nuclear forensics

A target was prepared for cyclic neutron activation analysis by heat sealing lithium-carbonate in polyethylene. The target was cyclically irradiated 50 times using a Thermo-Scientific accelerator based deuterium–tritium fusion neutron generator. During counting periods, gamma-rays emitted by 16 N were detected using three high-purity germanium detectors acquiring data in list-mode. Total counts acquired in each spectrum were compared between the three detectors to examine variability in geometric positioning of the target and variability of the generator intensity throughout the experiment. These two effects were determined to be the primary sources of variation in the measured counts. Variation in target positioning and generator intensity were found to increase the standard deviation by 34% and 33%, respectively. Transit times to the detector were found to be slower and more variable than transit to the generator but were well below the half second threshold needed to measure short-lived radionuclides with half-lives on the order of seconds. The standard deviation in irradiation time was found to be less than 1 milliseconds. The impact on statistical variability in the measured counts was negligible relative to the two primary sources of variation. Spectra acquired from each cycle were summed together. The sum of the peak areas from the 6.1 MeV gamma-ray and its corresponding single and double escape peaks were used to measure the half-life of 16N. The result of 7.108(15) seconds derived from data suggests that the currently published value of 7.13(2) seconds has minimal systematic bias induced by background.

43 PARTICLE ACCELERATORS↗

Extraction of Chemical Impurities for Forensic Investigations: A Case Study for Indoor Releases of a Sarin Surrogate

A solvent extraction approach was developed and examined for extraction of targeted organophosphorus compounds as well as nerve agent simulants from painted wallboard (PWB). Painted wallboard was chosen as a substrate due to its presence as large surface area media in an indoor environment that is applicable to a chemical agent release scenario. Three different solvent systems were examined with a 1:1 methylene chloride : acetone mixture having the most robust and consistent extraction for four target organophosphorus compounds (dimethyl methyl phosphonate (DMMP), diethyl methyl phosphonate (DEMP), diethyl methyl phosphonothioate (DEMPT), and diisopropyl methyl phosphonate (DIMP)). An average extraction efficiency of approximately 60% was obtained for these four compounds. The extraction approach was further demonstrated by extracting and detecting the chemical impurities present in neat DMMP that was vapor deposited onto painted wallboard tickets as a simulant to an agent release. Five chemical impurities that were present in DMMP - dimethyl phosphate, trimethyl ester phosphoric acid, ethyl methyl methylphosphonate, O,O,S-trimethyl ester phosphorothioic acid, and biphenyl- were detected on the PWB and were utilized to determine the source/supplier of the DMMP.

volatile organic compounds, chemical extraction, s↗